VIAVI Trilithic DSP Series meters including the 360 DSP installation and service meter
360 DSP Pro

VIAVI Trilithic 360 DSP Pro DOCSIS 3.1 Installation and Service Meter

DOCSIS 3.1 installation and service meter with built-in cable modem, FDR, source generator and upstream ingress and distortion analysis.

Channel Bandwidth
6 MHz and 8 MHz
Amplitude Range
-40 dBmV to +50 dBmV
Modulation Types – Analog
NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K
Modulation Types – Digital
16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
Datasheet

Overview

The VIAVI Trilithic 360 DSP Pro is a member of the DSP Series of DOCSIS 3.1 installation and service meters for cable service providers and contractors. The 180 and 360 DSP meters are designed for fast installation RF signal testing and troubleshooting, with the analog and digital signal measurements needed to certify an installation.

The 360 DSP has a built-in DOCSIS 3.1 modem, Ethernet and WiFi communications, and test results can be uploaded to StrataSync for near real-time views of measurement data. The internal modem operates in DOCSIS 3.0 (32x8) and DOCSIS 3.1 modes and supports cable modem statistics, OFDM profile analysis and network connectivity tests such as Ping, Traceroute, Throughput, VoIP and modem speed test.

The Pro model adds Upstream Traffic Control Plus, upstream linear distortion measurements (equalizer taps, group delay and in-channel response) and QAM Error Vector Spectrum analysis for viewing ingress underneath downstream QAM channels. Like the Advanced model, it also includes a Frequency Domain Reflectometer and a source generator for CW, QAM and OFDM carriers in the return band.

The meter has a color touchscreen interface, pass/fail indicators and autotest apps, along with a quick charge time, a built-in LED flashlight and a glow in the dark keypad. StrataSync, the VIAVI cloud-based asset, configuration and test data management system, can be reached over Ethernet, DOCSIS or WiFi, and its workflow option can deliver work orders and test profiles to the meter.

Key Features

  • Built-in DOCSIS 3.1 cable modem, Ethernet and WiFi communications
  • Upstream Traffic Control Plus with heat map view of upstream ingress
  • Upstream linear distortion measurements: equalizer taps, group delay and in-channel response
  • QAM Error Vector Spectrum analysis for ingress under downstream QAM channels
  • Frequency Domain Reflectometer for distance to cable faults
  • Source generator for CW, QAM and OFDM carriers from 5 to 85 MHz
  • 1.25 GHz frequency range
  • DOCSIS 3.1 OFDM signal measurements including PLC constellation, MER and decoder stress
  • Channel plan auto-discovery and channel plan scan with tilt measurement
  • Return spectrum analysis from 4 to 205 MHz and forward spectrum analysis from 5 to 1250 MHz
  • Cable modem OFDM profile statistics, multiple profile selection and distributed MER
  • WiFi survey with built-in 802.11 b/g/n 2.4/5 GHz adapter
  • Network test suite: Ping, VoIP, Throughput, Traceroute and modem speed test
  • Color touchscreen, pass/fail indicators and autotest apps
  • Built-in LED flashlight and glow in the dark keypad
  • Remote access and control from a PC, smart phone or tablet
  • StrataSync connectivity for asset and test data management
  • Multiple user profiles and multi-language support

Specifications

Level Measurement
Channel Bandwidth 6 MHz and 8 MHz
Amplitude Range -40 dBmV to +50 dBmV
Modulation Types – Analog NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K
Modulation Types – Digital 16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
OFDM: DOCSIS 3.1 option equipped meters only
Analog Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.0 dB from 0° to +50° C (32° to 122° F)
Digital Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.5 dB from 0° to +50° C (32° to 122° F)
Display Resolution 0.1 dB
Spectrum Measurement
Frequency Range – Return Path 4 to 205 MHz
Frequency Range – Forward Path 5 to 1250 MHz
Dual Return Path Diplexers 42 MHz: 4 to 42 MHz; 85 MHz: 4 to 85 MHz
Manually Adjustable Resolution Bandwidth Return Path: 300 kHz; Forward Path: 10, 30, 100, and 300 kHz; 1 and 3 MHz
Auto Ranging Resolution Bandwidth 10 kHz: Span ≤ 3.5 MHz; 30 kHz: Span ≤ 12.0 MHz; 100 kHz: Span ≤ 35.9 MHz; 300 kHz: Span ≤ 300 MHz; 1 MHz: Span ≤ 359.2 MHz; 3 MHz: Span ≥ 359.3 MHz
Display Spans Return Path: 4 to 42 MHz, 4 to 65 MHz, 4 to 85 MHz or 4 to 205 MHz; Forward Path: User-selectable in 1 kHz steps
Display Scale 1, 2, 5, 7.5 or 10 dB/division
Display Range 8 vertical divisions
when marker bar is hidden
Spurious Free Dynamic Range 60 dB
@ 25° C (77° F) (+50 dBmV)
Sensitivity (terminated) Return Path: -40 dBmV (4 to 205 MHz); Forward Path: -40 dBmV (5 to 1250 MHz)
Digital Channel Measurement
Deep Interleave Compatibility Yes
Downstream MER 40 ±2 dB @ +6 dBmV RF Input Level; 34 ±2 dB @ -6 dBmV RF Input Level
Downstream BER Method True BER, derived from code words not from MER
Downstream BER Standard ITU J.83 annex A, B, C
Downstream BER Range 1 E-7 to 1 E-9
@ -6 dBmV RF Input Level
Symbol Rates ≥ 2 MSPS; ≤ 6.952 MSPS
Cable Modem Measurement
Protocol Support DOCSIS 1.1 / 2.0 / 3.0 / 3.1; SNMP V1, V2c, V3
DOCSIS 3.1: DOCSIS 3.1 option equipped meters only
Compliance Certificates FCC
CM Diplexer 85 MHz: 5 to 85 MHz
Receiver Frequency (edge to edge) 108 to 1218 MHz
Receiver Channel Bandwidth 6 MHz
Receiver Signal Level -15 to 15 dBmV
DOCSIS 3.0 Demodulation 64 QAM, 256 QAM
DOCSIS 3.0 Downstream Data Rate Up to 1.2 Gbps with 32 downstream channel bonding (DOCSIS 32x8)
DOCSIS 3.1 Demodulation Multi-Carrier OFDM 16 to 4096 QAM
DOCSIS 3.1 option equipped meters only
DOCSIS 3.1 Downstream Data Rate Up to 2.5 Gbps with 2 OFDM 196 MHz Downstream Channels
DOCSIS 3.1 option equipped meters only
Transmitter Frequency (edge to edge) 5 to 85 MHz
Transmitter Signal Level Controlled by CMTS though power ranging function
DOCSIS 3.0 Modulation QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, and 128 QAM (SCDMA only)
DOCSIS 3.0 Upstream Data Rate Up to 320 Mbps with 8 upstream channels bonding
DOCSIS 3.1 Modulation Multi-Carrier OFDMA BPSK to 4096 QAM
DOCSIS 3.1 option equipped meters only
DOCSIS 3.1 Upstream Data Rate Up to 1 Gbps with 2 OFDMA 96 MHz Upstream Channels
DOCSIS 3.1 option equipped meters only
Upstream SC-QAM Channels Up to eight (8)
Downstream Channels Up to 32 SC-QAM channels in a DOCSIS 3.0 only environment; up to two (2) OFDM channels and 30 SC-QAM channels in a mixed DOCSIS 3.0 and DOCSIS 3.1 environment
OFDM: DOCSIS 3.1 option equipped meters only
OFDM Profile Decoding Up to four (4) Profiles 0-3 (A-D)
DOCSIS 3.1 option equipped meters only
Carrier-to-Noise Measurement
Minimum Input Level for Full Range +10 dBmV
In-service, non-scrambled standard channels only
Dynamic Range 50 dB
Resolution < 0.5 dB
Tilt Measurement
Max Number of Carriers 14
dependent on favorite channel setup
High/Low Delta Resolution 0.1 dB
Scan Video, audio, pilot, and digital carriers
Analog and Digital Hum
Minimum Input Level 0 dBmV
In-service, non-scrambled standard channels only
Range 0 to 5%
Resolution 0.10%
Accuracy ±0.5%
Frequency Domain Reflectometer
Velocity of Propagation Adjustable from 60.0 to 99.0% in 0.1% increments
Working Distance Minimum: 755 feet (230 meters) @ VoP of 60.0%; Maximum: 1247 feet (380 meters) @ VoP of 99.0%
Amplitude Range 0 to -80 dBRL
Distance Accuracy 5 feet
Source Generator
Modulation CW, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM, OFDM (4K/8K)
OFDM: DOCSIS 3.1 option equipped meters only
OFDM Subcarrier Modulation 16 to 4096 QAM, PLC Configurable
DOCSIS 3.1 option equipped meters only
Frequency Range 5 to 85 MHz
Source Width CW: 50 kHz; QAM: 6 MHz; OFDM: 6 to 24 MHz
OFDM: DOCSIS 3.1 option equipped meters only
Amplitude CW: Adjustable from 10 to 55 dBmV; QAM: Adjustable from 10 to 45 dBmV; OFDM: Adjustable from 10 to 40 dBmV
OFDM: DOCSIS 3.1 option equipped meters only
QAM Symbol Rates 0.64, 1.28, 2.56, 5.12 MSPS
QAM Error Rates BER: Adjustable from 0 to 1.00E-2; MER: > 38 dB
CW Source Accuracy ±2 dB
Physical
Construction Rubber overmolded plastic housing
Control Glow in the dark keypad and LCD touchscreen and/or via a wireless connection to a mobile device such as a laptop, tablet, iPad® or iPhone®, or Android® handset
Display Color LCD touchscreen, 480 x 272 pixels (approx 4” x 2.25”)
Annunciators Audible annunciator for key strokes
Antenna Internal WiFi antenna, 2 dB gain
Flashlight High-intensity LED (0.25W)
Dimensions w/o Case (H x W x D) 8.6 x 6.1 x 2.00 in (21.84 x 15.94 x 5.08 cm)
Dimensions w/ Case (H x W x D) 9.6 x 7.1 x 3.00 in (24.38 x 18.03 x 7.62 cm)
Weight w/o Case 2.9 lbs (1.32 Kg)
Weight w/ Case 3.9 lbs (1.79 Kg)
Interfaces
Tx Test Port 75 Ohm Replaceable F-Type Connector
Source Generator Output Transmission Only
Tx/Rx Test Port 75 Ohm Replaceable F-Type Connector
Upstream and Downstream RF Measurements, DOCSIS 3.1 Modem
Ethernet RJ45 Management Port (10/100 Mbps)
WiFi 802.11 b/g/n 2.4/5 GHz WiFi Adapter
USB USB 2.0 Type-A Standard Port
Battery and Power
Operating Time 8 to 10 hours, dependent on use
Charge Time 4 hours
Battery Two 2600 mAh @ 7.4V Li-Ion internal batteries, factory replaceable
Power Adapter Input: 100 to 240 VAC ~ 50 to 60 Hz, 1.2A Max; Output: 15 VDC, 3.34A
Environmental
Storage -18° to +50° C (0° to 122° F)
Operating Temperature 0° to +50° C (32° to 122° F)
Ordering
Part Number TRI-DSP-360-D31-PRO
Adds Upstream Traffic Control Plus, Upstream Linear Distortion Measurements, and QAM Error Vector Spectrum Analysis

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Cable subscriber installation and certification
  • DOCSIS 3.1 service troubleshooting
  • Return spectrum analysis
  • Level, C/N, QAM and OFDM measurement
  • Channel plan scan with tilt measurement
  • Upstream ingress troubleshooting
  • Home leakage testing
  • Contractor workflow and test result reporting

Options & Accessories

Option Description
TRI-LKG-HL-METER-KIT Seeker Home Leakage Companion Kit — Seeker HL Source Transmitter, Dual-Band Antenna, Near-Field Probe and Case
TRI-DSP-SW-HL-LKG-OPT DSP Meter Leakage Software Option
TRI-ACCY-RF-TEST-CBL I/O-15 Precision test cable
TRI-ISTOP-1000MHZ I-Stop 1 GHz Test Probe — Ingress troubleshooting probe
TRI-ISTOP-1250MHZ I-Stop Test Probe — Ingress troubleshooting probe
TRI-TLB-46-LPF TLB-46 Return measurement low-pass filter
MP-80A MP-80A USB Optical Power Meter
FBP-P5000i P5000i USB Fiber Scope
TRI-DSP-360-CASE-REPL Replacement fitted case
TRI-DSP-STRAP-REPL Replacement shoulder strap
TRI-DSP-PWR-ADPT-NEW Replacement charger (no power cord)