VIAVI Trilithic DSP Series meters including the 1G DSP plant maintenance meter
VIAVI / DSP Series / Plant Maintenance Meters
1G DSP with OPM/VFL Pro

VIAVI Trilithic 1G DSP with OPM/VFL Pro Plant Maintenance Meter with Optical Power Meter and VFL

DOCSIS 3.1 plant maintenance meter combining CATV, cable modem and gigabit Ethernet testing with a built-in optical power meter and visual fault locator.

Channel Bandwidth
6 MHz and 8 MHz
Amplitude Range
-40 dBmV to +50 dBmV
Modulation Types (Analog)
NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K
Modulation Types (Digital)
16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
Datasheet

Overview

The VIAVI Trilithic 1G DSP with OPM/VFL Pro (part number TRI-DSP-1G-D31-VFL-PRO) is a plant maintenance meter in the DSP Series. It combines CATV, DOCSIS 3.1 cable modem, Gigabit Ethernet and optical testing in one instrument for systemwide testing, and adds a built-in optical power meter (OPM) and visual fault locator (VFL) to the 1G DSP Pro configuration.

The meter achieves throughput testing speeds of up to a gigabit per second using a dedicated Ethernet test port or the internal cable modem. It performs roundtrip or one-way Key Parameter Index (KPI) measurements with constant payload testing for Layer 2 through Layer 4, for verification of Ethernet Service Level Agreement (SLA) and Quality of Service (QoS) metrics.

Optical testing

The optical hardware package includes a built-in FTTx-ready optical power meter for testing passive optical networks, with absolute and relative measurements at the ITU-T G983.3 recommended wavelengths of 1310 nm, 1490 nm and 1550 nm and interchangeable FC, SC and ST style adapters. The VFL emits a Class III visible red laser for locating loss points in patch cords, patch panels and enclosures on damaged single-mode and multi-mode fiber.

Operation

The 1G DSP has a large, high-resolution color touchscreen, simple pass/fail indicators and autotest apps. It supports remote meter control via a web browser, up to five user profiles, long battery life with a quick charge time, and a glow-in-the-dark keypad. Test results and configurations can be synchronized with VIAVI StrataSync over Ethernet, DOCSIS or WiFi.

Key Features

  • Combines CATV, DOCSIS 3.1 cable modem, Gigabit Ethernet and optical testing in one meter
  • Built-in optical power meter for 1310 nm, 1490 nm and 1550 nm
  • Built-in visual fault locator for locating loss points in patch cords, patch panels and enclosures
  • Throughput testing up to 1 GbE using a dedicated test port or the internal cable modem
  • Roundtrip or one-way constant payload testing for Layer 2-4 Ethernet SLA and QoS verification
  • SFP optical power measurement with link speed, wavelength, Tx power and Rx power
  • Internal DOCSIS 3.1 modem operating in DOCSIS 3.0 (32x8) and DOCSIS 3.1 modes
  • DOCSIS 3.1 OFDM signal measurements including PLC constellation, MER and pre/post BER
  • Upstream Traffic Control Plus and Downstream QAM Error Vector Spectrum for ingress under carrier
  • Upstream linear distortion testing: equalizer taps, group delay and in-channel response
  • Frequency domain reflectometer and source generator with dual RF test ports
  • Return spectrum 4 to 205 MHz and forward spectrum 5 to 1250 MHz
  • Channel plan scan with tilt measurement and channel plan auto-discovery
  • Built-in 802.11 b/g/n 2.4/5 GHz WiFi with survey mode
  • Network test suite with Ping, VoIP, Throughput and Traceroute
  • Remote control via web browser from PC, smartphone or tablet
  • Multi-user support for up to 5 technicians
  • Large color touchscreen with glow in the dark keypad
  • StrataSync asset, configuration and test data management

Specifications

Level Measurement
Channel Bandwidth 6 MHz and 8 MHz
Amplitude Range -40 dBmV to +50 dBmV
Modulation Types (Analog) NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K
Modulation Types (Digital) 16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
OFDM: DOCSIS 3.1 option equipped meters only
Analog Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.0 dB from 0° to +50° C (32° to 122° F)
Digital Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.5 dB from 0° to +50° C (32° to 122° F)
Display Resolution 0.1 dB
Spectrum Measurement
Frequency Range (Return Path) 4 to 205 MHz
Frequency Range (Forward Path) 5 to 1250 MHz
Dual Return Path Diplexers 42 MHz: 4 to 42 MHz; 85 MHz: 4 to 85 MHz
Manually Adjustable Resolution Bandwidth Return Path: 300 kHz; Forward Path: 10, 30, 100, and 300 kHz; 1 and 3 MHz
Auto Ranging Resolution Bandwidth 10 kHz: Span ≤ 3.5 MHz; 30 kHz: Span ≤ 12.0 MHz; 100 kHz: Span ≤ 35.9 MHz; 300 kHz: Span ≤ 300 MHz; 1 MHz: Span ≤ 359.2 MHz; 3 MHz: Span ≥ 359.3 MHz
Display Spans Return Path: 4 to 42 MHz, 4 to 65 MHz, 4 to 85 MHz or 4 to 205 MHz; Forward Path: User-selectable in 1 kHz steps
Display Scale 1, 2, 5, 7.5 or 10 dB/division
Display Range 8 vertical divisions
when marker bar is hidden
Spurious Free Dynamic Range 60 dB
@ 25° C (77° F) (+50 dBmV)
Sensitivity (terminated) Return Path: -40 dBmV (4 to 205 MHz); Forward Path: -40 dBmV (5 to 1250 MHz)
Digital Channel Measurement
Deep Interleave Compatibility Yes
Downstream MER 40 ±2 dB @ +6 dBmV RF Input Level; 34 ±2 dB @ -6 dBmV RF Input Level
Downstream BER Method True BER, derived from code words not from MER
Downstream BER Standard ITU J.83 annex A, B, C
Downstream BER Range 1 E-7 to 1 E-9
@ -6 dBmV RF Input Level
Symbol Rates ≥ 2 MSPS; ≤ 6.952 MSPS
Cable Modem Measurement
Protocol Support DOCSIS 1.1 / 2.0 / 3.0 / 3.1; SNMP V1, V2c, V3
Compliance Certificates FCC
CM Diplexer 85 MHz: 5 to 85 MHz
Receiver Frequency (edge to edge) 108 to 1218 MHz
Receiver Channel Bandwidth 6 MHz
Receiver Signal Level -15 to 15 dBmV
DOCSIS 3.0 Demodulation 64 QAM, 256 QAM
DOCSIS 3.0 Downstream Data Rate Up to 1.2 Gbps with 32 downstream channel bonding (DOCSIS 32x8)
DOCSIS 3.1 Demodulation Multi-Carrier OFDM 16 to 4096 QAM
DOCSIS 3.1 option equipped meters only
DOCSIS 3.1 Downstream Data Rate Up to 2.5 Gbps with 2 OFDM 196 MHz Downstream Channels
DOCSIS 3.1 option equipped meters only
Transmitter Frequency (edge to edge) 5 to 85 MHz
Transmitter Signal Level Controlled by CMTS though power ranging function
DOCSIS 3.0 Modulation QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, and 128 QAM (SCDMA only)
DOCSIS 3.0 Upstream Data Rate Up to 320 Mbps with 8 upstream channels bonding
DOCSIS 3.1 Modulation Multi-Carrier OFDMA BPSK to 4096 QAM
DOCSIS 3.1 option equipped meters only
DOCSIS 3.1 Upstream Data Rate Up to 1 Gbps with 2 OFDMA 96 MHz Upstream Channels
DOCSIS 3.1 option equipped meters only
Carrier-to-Noise Measurement
Minimum Input Level for Full Range +10 dBmV
In-service, non-scrambled standard channels only
Dynamic Range 50 dB
Resolution < 0.5 dB
Tilt Measurement
Max Number of Carriers 14
dependent on favorite channel setup
High/Low Delta Resolution 0.1 dB
Scan Video, audio, pilot, and digital carriers
Analog and Digital Hum
Minimum Input Level 0 dBmV
In-service, non-scrambled standard channels only
Range 0 to 5%
Resolution 0.10%
Accuracy ±0.5%
Frequency Domain Reflectometer
Velocity of Propagation Adjustable from 60.0 to 99.0% in 0.1% increments
Working Distance Minimum: 755 feet (230 meters) @ VoP of 60.0%; Maximum: 1247 feet (380 meters) @ VoP of 99.0%
Amplitude Range 0 to -80 dBRL
Distance Accuracy 5 feet
Source Generator
Modulation CW, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM, OFDM (4K/8K)
OFDM: DOCSIS 3.1 option equipped meters only
OFDM Subcarrier Modulation 16 to 4096 QAM, PLC Configurable
DOCSIS 3.1 option equipped meters only
Frequency Range 5 to 85 MHz
Source Width CW: 50 kHz; QAM: 6 MHz; OFDM: 6 to 24 MHz
OFDM: DOCSIS 3.1 option equipped meters only
Amplitude CW: Adjustable from 10 to 55 dBmV; QAM: Adjustable from 10 to 45 dBmV; OFDM: Adjustable from 10 to 40 dBmV
OFDM: DOCSIS 3.1 option equipped meters only
QAM Symbol Rates 0.64, 1.28, 2.56, 5.12 MSPS
QAM Error Rates BER: Adjustable from 0 to 1.00E-2; MER: > 38 dB
CW Source Accuracy ±2 dB
Optical Power Meter
Finish UPC and APC
Additional Connectors FC/SC/ST
Measurement Range -50 dBm to +26 dBm
Display Resolution 0.01 dB
Tone Detection Range -30 dBm to +6 dBm
Tone Detection 270 Hz, 330 Hz, 1 kHz, 2 kHz
Wavelengths 1310 nm, 1490 nm, 1550 nm
Accuracy +/-0.5dB > -40 dBm @ 25º C; +/- 1dB < -40 dBm @ 25º C
Visual Fault Locator (VFL)
Port Style FC Style Adapter
Fiber Size 9/125 μm
Wavelength 650 nm
Output Power 3.0 mW
Class III visible red light laser
Pulse Duration CW (always on) or 2 Hz (0.25 sec pulse)
Maximum Radiant Power < 5.0 mW
Turn-On Safety Delay 2 seconds
Physical
Construction Rubber overmolded plastic housing
Control Glow in the dark keypad and LCD touchscreen and/or via a wireless connection to a mobile device such as a laptop, tablet, iPad® or iPhone®, or Android® handset
Display Color LCD touchscreen, 800 x 480 pixels (approx 4.5" x 2.75")
1G DSP value
Annunciators Audible annunciator for key strokes
Antenna Internal WiFi antenna, 2 dB gain
Flashlight High-intensity LED (0.25W)
Dimensions w/o Case (H x W x D) 8.6 x 6.1 x 2.00 in (21.84 x 15.94 x 5.08 cm)
Dimensions w/ Case (H x W x D) 9.6 x 7.1 x 3.00 in (24.38 x 18.03 x 7.62 cm)
Weight w/o Case 3.75 lbs (1.70 Kg)
1G DSP value
Weight w/ Case 4.75 lbs (2.15 Kg)
1G DSP value
Interfaces
Tx Test Port 75 Ohm Replaceable F-Type Connector
Source Generator Output Transmission Only
Tx/Rx Test Port 75 Ohm Replaceable F-Type Connector
Upstream and Downstream RF Measurements; DOCSIS 3.1 Modem
Ethernet RJ45 Management Port (10/100 Mbps); RJ45 Electrical Test Port (10/100/1000 Base-T); SFP Optical Test Port (100/1000 Base-X)
Electrical and SFP test ports: 1G only
WiFi 802.11 b/g/n 2.4/5 GHz WiFi Adapter
360 & 1G only
USB USB 2.0 Type-A Standard Port
Battery and Power
Operating Time 12 hours plus, dependent on use
1G DSP value
Charge Time 4 hours
Battery Three 2600 mAh @ 7.4V Li-Ion internal batteries, factory replaceable
1G DSP value
Power Adapter Input: 100 to 240 VAC ~ 50 to 60 Hz, 1.2A Max; Output: 15 VDC, 3.34A
Environmental
Storage -18° to +50° C (0° to 122° F)
Operating Temperature 0° to +50° C (32° to 122° F)
Ordering
Part Number TRI-DSP-1G-D31-VFL-PRO
Plant Maintenance Meter with optical power meter and visual fault locator

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Cable plant maintenance
  • Return spectrum analysis
  • Level, C/N, QAM and OFDM measurement
  • Channel plan scan with tilt measurement
  • DOCSIS 3.0 and 3.1 cable modem service testing
  • Ethernet service SLA and QoS verification
  • FTTx and passive optical network power measurement
  • Fiber patch cord and patch panel fault location
  • Upstream ingress troubleshooting
  • Coaxial cable fault location

Options & Accessories

Option Description
TRI-LKG-HL-METER-KIT Home Leakage Test Kit — Seeker Home Leakage Companion Kit: Seeker HL Source Transmitter, Dual-Band Antenna, Near-Field Probe and Case
TRI-DSP-SW-HL-LKG-OPT DSP Meter Leakage Software Option
TRI-ACCY-RF-TEST-CBL I/O-15 Precision test cable
TRI-ISTOP-1000MHZ I-Stop 1 GHz Test Probe — Ingress troubleshooting probe
TRI-ISTOP-1250MHZ I-Stop Test Probe — Ingress troubleshooting probe
TRI-TLB-46-LPF TLB-46 Return measurement low-pass filter
MP-80A USB Optical Power Meter
FBP-P5000i P5000i USB Fiber Scope
TRI-DSP-1G-CASE-REPL Replacement fitted case
TRI-DSP-STRAP-REPL Replacement shoulder strap
TRI-DSP-PWR-ADPT-NEW Replacement charger (no power cord)

Documents & Resources