VIAVI Trilithic DSP Series meters including the 1G DSP plant maintenance meter
VIAVI / DSP Series / Plant Maintenance Meters
1G DSP SWEEP with TDR

VIAVI Trilithic 1G DSP SWEEP with TDR DOCSIS 3.1 Plant Maintenance Meter

DOCSIS 3.1 plant maintenance meter with step-type TDR, forward/return sweepless and active sweep, cable modem and Gigabit Ethernet testing.

Part Number
TRI-DSP-1G-D31-TDR-SWEEP
Datasheet

Overview

The VIAVI Trilithic 1G DSP SWEEP with TDR (part number TRI-DSP-1G-D31-TDR-SWEEP) is the plant maintenance model of the DSP Series Meters. It is described by the manufacturer as a plant maintenance meter with TDR and FWD/REV sweepless-active sweep. It combines CATV signal measurements, a DOCSIS 3.1 cable modem, Gigabit Ethernet testing and coaxial cable fault location in one handheld instrument.

Sweep

The meter supports both sweepless and active sweep methods. Cable modem sweep uses the internal modem to run in-band return sweeps within the modem carriers, and forward passive sweep uses the live carriers in the HFC distribution system to set amplifier tilt and gain without dedicated headend gear. With headend equipment, the meter can run RSA high-resolution return sweep with the 8310 RSA, forward active sweep with the 8300 FST, and SSR high-speed return sweep and SST Compare with the 9581 SST.

TDR

The built-in step-type TDR locates impairments in coaxial cable such as poor splices, water intrusion, pinched coax, impedance mismatches and bridged taps. It can also measure how much cable is left on a reel. Because it uses a step waveform, it has no dead zone, does not require a pulse width or gain setting, and matches cable impedance automatically.

Ethernet and Connectivity

The 1G DSP can run throughput tests at up to a gigabit per second through a dedicated Ethernet test port or the internal cable modem. It supports roundtrip or one-way Layer 2 through Layer 4 constant payload testing to verify Ethernet SLA and QoS metrics. It can connect over Ethernet, WiFi, GigE or cable modem, can be controlled remotely through a web browser, and syncs test results and configurations with StrataSync.

The instrument has an 800 x 480 color touchscreen, pass/fail indicators, autotest apps, a glow-in-the-dark keypad, and support for up to five user profiles.

Key Features

  • Step-type TDR with over 4000 meters measurement range, zero dead zone and better than one foot accuracy
  • Cable Modem Sweep using the internal DOCSIS 3.1 modem, with no headend sweep gear required
  • Forward Passive Sweep using live HFC carriers
  • Forward Active Sweep with the 8300 FST Forward SpeedSweep Transmitter
  • RSA High-Resolution Return Sweep with the 8310 RSA, tracking up to 643 sweep points
  • SSR High-Speed Return Sweep and SST Compare with the 9581 SST
  • Internal DOCSIS 3.1 cable modem operating in DOCSIS 3.0 (32x8) and DOCSIS 3.1 modes
  • Gigabit throughput testing through a dedicated Ethernet test port or the internal cable modem
  • Roundtrip or one-way Layer 2-4 constant payload testing for Ethernet SLA and QoS verification
  • SFP optical power measurement with link speed, wavelength, Tx and Rx power
  • Upstream Traffic Control Plus real-time ingress view with heat map
  • Downstream QAM Error Vector Spectrum for ingress under carrier
  • Upstream linear distortion testing: equalizer taps, group delay and in-channel response
  • Frequency Domain Reflectometer for distance to cable faults
  • Dual RF test ports and source generator for CW, QAM and OFDM carriers from 5 to 85 MHz
  • DOCSIS 3.1 OFDM measurements including PLC constellation, MER and decoder stress
  • Forward spectrum 5 to 1250 MHz and return spectrum 4 to 205 MHz
  • Built-in 802.11 b/g/n 2.4/5 GHz WiFi with survey mode
  • Channel plan auto discovery, channel plan scan and tilt measurement
  • Remote control of the meter via a web browser
  • Up to 5 user profiles on one meter
  • StrataSync asset, configuration and test data management
  • Large 800 x 480 pixel color touchscreen and glow in the dark keypad

Specifications

Ordering
Part Number TRI-DSP-1G-D31-TDR-SWEEP
Plant Maintenance Meter with TDR and FWD/REV Sweepless-Active Sweep
TDR
Maximum Distance 15954 ft (4862m)
Distance accuracy <1 ft
Noise Filter / AVG 1 to 100 samples
Measurement time <2 Seconds
TDR type Step-type, zero dead zone
Measurement range of over 4000 meters; accuracy of less than one foot for cables at any length
Level Measurement
Channel Bandwidth 6 MHz and 8 MHz
Amplitude Range -40 dBmV to +50 dBmV
Modulation Types (Analog) NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K
Modulation Types (Digital) 16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
OFDM on DOCSIS 3.1 option equipped meters only
Analog Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.0 dB from 0° to +50° C (32° to 122° F)
Digital Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.5 dB from 0° to +50° C (32° to 122° F)
Display Resolution 0.1 dB
Spectrum Measurement
Frequency Range (Return Path) 4 to 205 MHz
Frequency Range (Forward Path) 5 to 1250 MHz
Dual Return Path Diplexers 42 MHz: 4 to 42 MHz; 85 MHz: 4 to 85 MHz
Manually Adjustable Resolution Bandwidth Return Path: 300 kHz; Forward Path: 10, 30, 100, and 300 kHz; 1 and 3 MHz
Auto Ranging Resolution Bandwidth 10 kHz: Span ≤ 3.5 MHz; 30 kHz: Span ≤ 12.0 MHz; 100 kHz: Span ≤ 35.9 MHz; 300 kHz: Span ≤ 300 MHz; 1 MHz: Span ≤ 359.2 MHz; 3 MHz: Span ≥ 359.3 MHz
Display Spans Return Path: 4 to 42 MHz, 4 to 65 MHz, 4 to 85 MHz or 4 to 205 MHz; Forward Path: User-selectable in 1 kHz steps
Display Scale 1, 2, 5, 7.5 or 10 dB/division
Display Range 8 vertical divisions
when marker bar is hidden
Spurious Free Dynamic Range 60 dB
@ 25° C (77° F) (+50 dBmV)
Sensitivity (terminated) Return Path: -40 dBmV (4 to 205 MHz); Forward Path: -40 dBmV (5 to 1250 MHz)
Digital Channel Measurement
Deep Interleave Compatibility Yes
Downstream MER 40 ±2 dB @ +6 dBmV RF Input Level; 34 ±2 dB @ -6 dBmV RF Input Level
Downstream BER Method True BER, derived from code words not from MER
Downstream BER Standard ITU J.83 annex A, B, C
Downstream BER Range 1 E-7 to 1 E-9
@ -6 dBmV RF Input Level
Symbol Rates ≥ 2 MSPS; ≤ 6.952 MSPS
Cable Modem Measurement
Protocol Support DOCSIS 1.1 / 2.0 / 3.0 / 3.1; SNMP V1, V2c, V3
Compliance Certificates FCC
CM Diplexer 85 MHz: 5 to 85 MHz
Receiver Frequency (edge to edge) 108 to 1218 MHz
Receiver Channel Bandwidth 6 MHz
Receiver Signal Level -15 to 15 dBmV
DOCSIS 3.0 Demodulation 64 QAM, 256 QAM
DOCSIS 3.0 Downstream Data Rate Up to 1.2 Gbps with 32 downstream channel bonding (DOCSIS 32x8)
DOCSIS 3.1 Demodulation Multi-Carrier OFDM 16 to 4096 QAM
DOCSIS 3.1 Downstream Data Rate Up to 2.5 Gbps with 2 OFDM 196 MHz Downstream Channels
Transmitter Frequency (edge to edge) 5 to 85 MHz
Transmitter Signal Level Controlled by CMTS though power ranging function
DOCSIS 3.0 Modulation QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, and 128 QAM (SCDMA only)
DOCSIS 3.0 Upstream Data Rate Up to 320 Mbps with 8 upstream channels bonding
DOCSIS 3.1 Modulation Multi-Carrier OFDMA BPSK to 4096 QAM
DOCSIS 3.1 Upstream Data Rate Up to 1 Gbps with 2 OFDMA 96 MHz Upstream Channels
Carrier-to-Noise, Tilt and Hum
C/N Minimum Input Level for Full Range +10 dBmV
In-service, non-scrambled standard channels only
C/N Dynamic Range 50 dB
C/N Resolution < 0.5 dB
Tilt Max Number of Carriers 14
dependent on favorite channel setup
Tilt High/Low Delta Resolution 0.1 dB
Tilt Scan Video, audio, pilot, and digital carriers
Hum Minimum Input Level 0 dBmV
In-service, non-scrambled standard channels only
Hum Range 0 to 5%
Hum Resolution 0.10%
Hum Accuracy ±0.5%
Frequency Domain Reflectometer
Velocity of Propagation Adjustable from 60.0 to 99.0% in 0.1% increments
Working Distance Minimum: 755 feet (230 meters) @ VoP of 60.0%; Maximum: 1247 feet (380 meters) @ VoP of 99.0%
Amplitude Range 0 to -80 dBRL
Distance Accuracy 5 feet
Source Generator
Modulation CW, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM, OFDM (4K/8K)
OFDM Subcarrier Modulation 16 to 4096 QAM, PLC Configurable
Frequency Range 5 to 85 MHz
Source Width CW: 50 kHz; QAM: 6 MHz; OFDM: 6 to 24 MHz
Amplitude CW: Adjustable from 10 to 55 dBmV; QAM: Adjustable from 10 to 45 dBmV; OFDM: Adjustable from 10 to 40 dBmV
QAM Symbol Rates 0.64, 1.28, 2.56, 5.12 MSPS
QAM Error Rates BER: Adjustable from 0 to 1.00E-2; MER: > 38 dB
CW Source Accuracy ±2 dB
Sweep
RSA Sweep sweep points up to 643 individual sweep points
Full sweep displayed every four seconds; requires 8310 RSA Return SpeedSweep Analyzer in the headend
Cable Modem Sweep injected carriers up to eight (8) upstream modem carriers
Works with any DOCSIS 3.0 or DOCSIS 3.1 compatible CMTS with pre-EQ enabled
SSR Sweep test carriers up to eight user-selectable test carriers
Measured by the 9581 SST in the headend
Physical
Construction Rubber overmolded plastic housing
Control Glow in the dark keypad and LCD touchscreen and/or via a wireless connection to a mobile device such as a laptop, tablet, iPad® or iPhone®, or Android® handset
Display
1G DSP
Color LCD touchscreen, 800 x 480 pixels (approx 4.5” x 2.75”)
Annunciators Audible annunciator for key strokes
Antenna Internal WiFi antenna, 2 dB gain
Flashlight High-intensity LED (0.25W)
Dimensions w/o Case (H x W x D) 8.6 x 6.1 x 2.00 in (21.84 x 15.94 x 5.08 cm)
Dimensions w/ Case (H x W x D) 9.6 x 7.1 x 3.00 in (24.38 x 18.03 x 7.62 cm)
Weight w/o Case
1G DSP
3.75 lbs (1.70 Kg)
Weight w/ Case
1G DSP
4.75 lbs (2.15 Kg)
Interfaces
Tx Test Port 75 Ohm Replaceable F-Type Connector
Source Generator Output Transmission Only
Tx/Rx Test Port 75 Ohm Replaceable F-Type Connector
Upstream and Downstream RF Measurements, DOCSIS 3.1 Modem
Ethernet RJ45 Management Port (10/100 Mbps); RJ45 Electrical Test Port (10/100/1000 Base-T); SFP Optical Test Port (100/1000 Base-X)
WiFi 802.11 b/g/n 2.4/5 GHz WiFi Adapter
USB USB 2.0 Type-A Standard Port
Battery and Power
Operating Time
1G DSP
12 hours plus, dependent on use
Charge Time 4 hours
Battery
1G DSP
Three 2600 mAh @ 7.4V Li-Ion internal batteries, factory replaceable
1G DSP
Power Adapter Input: 100 to 240 VAC ~ 50 to 60 Hz, 1.2A Max; Output: 15 VDC, 3.34A
Environmental
Storage -18° to +50° C (0° to 122° F)
Operating Temperature 0° to +50° C (32° to 122° F)

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Cable plant maintenance
  • Forward and return path sweep and balancing
  • Coaxial cable fault location
  • Return spectrum analysis
  • Level, C/N, QAM and OFDM measurement
  • Channel plan scan with tilt measurement
  • DOCSIS 3.1 cable modem service testing
  • Ethernet SLA and QoS verification
  • Upstream ingress troubleshooting
  • Home leakage testing

Options & Accessories

Option Description
TRI-LKG-HL-METER-KIT Seeker Home Leakage Companion Kit — Seeker HL Source Transmitter, Dual-Band Antenna, Near-Field Probe and Case
TRI-DSP-SW-HL-LKG-OPT DSP Meter Leakage Software Option
TRI-ACCY-RF-TEST-CBL I/O-15 Precision test cable
TRI-ISTOP-1000MHZ I-Stop 1 GHz Test Probe — Ingress troubleshooting probe
TRI-ISTOP-1250MHZ I-Stop Test Probe — Ingress troubleshooting probe
TRI-TLB-46-LPF TLB-46 Return measurement low-pass filter
MP-80A MP-80A USB Optical Power Meter
FBP-P5000i P5000i USB Fiber Scope
TRI-DSP-1G-CASE-REPL Replacement fitted case
TRI-DSP-STRAP-REPL Replacement shoulder strap
TRI-DSP-PWR-ADPT-NEW Replacement charger (no power cord)

Documents & Resources