T-BERD/MTS 4100 Series CWDM OTDR Module E41CWDM10L, 10 Wavelengths 1271 to 1451 nm
CWDM OTDR module covering 10 CWDM wavelengths from 1271 nm to 1451 nm for T-BERD/MTS platforms, with integrated CW light source.
- Wavelength range
- 1271 to 1451 nm
- CWDM wavelengths
- 1271/1291/1311/1331/1351/1371/1391/1411/1431/1451nm +/-3nm
- Pulsewidth
- 10 ns to 20 μs
- Dynamic range
- 35dB
Overview
The VIAVI E41CWDM10L is the CWDM10L version of the 4100 Series CWDM OTDR modules. It covers 10 CWDM wavelengths from 1271 nm to 1451 nm and is used with the T-BERD/MTS-2000, -4000 V2 and -5800 platforms. Combined with the CWDM10U module (1431 to 1611 nm), 18 CWDM wavelengths are covered in two OTDR modules.
The module allows cable operators, dark fiber providers and telecommunication service providers to test through MUX/DEMUX and perform end-to-end link characterization or troubleshooting of active C-RAN, DAS and mobile fronthaul CWDM networks. In-service testing and automatic traffic detection make it possible to test new CWDM wavelength routes or locate faults without disrupting traffic on active channels.
Light source and analysis
An integrated continuous wave light source operates at the same wavelengths as the OTDR and supports modulation, which can be used to verify end-to-end continuity. The optional Smart Link Mapper (SLM) converts the OTDR trace into icons for splices, connectors and MUX/DEMUX elements. Platform testing features include automatic multitest configurations, a summary results table with pass/fail analysis and FastReport onboard report generation.
The module can be combined with the CWDM spectrum analyzer module COSA-4055 to measure the wavelengths and power levels of active CWDM channels.
Key Features
- 10 CWDM wavelengths from 1271 nm to 1451 nm in one module
- 18 CWDM wavelengths covered in 2 modules when combined with the CWDM10U version
- Optimized performance for access and metro applications
- Integrated CW light source with modulation capability (same OTDR wavelengths)
- Instantaneous traffic detection
- In-service testing capability
- Optional Smart Link Mapper (SLM) converts the OTDR trace into icons for splice, connector and MUX/DEMUX
- Automatic multitest configurations
- Summary results table with pass/fail analysis
- FastReport onboard report generation
- Compatible with T-BERD/MTS-2000, -4000 V2 and -5800 platforms
Specifications
|
Wavelength range
E41CWDM10L
|
1271 to 1451 nm
Part number E41CWDM10L
|
|---|---|
|
CWDM wavelengths
E41CWDM10L
|
1271/1291/1311/1331/1351/1371/1391/1411/1431/1451nm +/-3nm
Laser at 25°C and measured at 10 µs
|
| Pulsewidth | 10 ns to 20 μs |
| Dynamic range |
35dB
One-way difference between the extrapolated backscattering level at the start of the fiber and the RMS noise level, after 3 minutes averaging and using the largest pulsewidth
|
| Event dead zone |
1.5 m
Measured at ±1.5 dB down from the peak of an unsaturated reflective event using the shortest pulsewidth
|
| Attenuation dead zone |
5 m
Measured at ±0.5 dB from the linear regression using a FC/PC reflectance and using the shortest pulsewidth
|
| Automatic traffic detection | Yes |
| In-service testing | Yes |
| Wavelengths | same as OTDR |
|---|---|
| Output power |
-3.5 dBm
Subtract 3 dB when used in modulation mode (270/330/1/2 kHz)
|
| Operating modes | CW, 270 Hz, 330 Hz, 1 kHz, 2 kHz |
| Mode |
Automatic or dual cursor
Typical at 25°C
|
|---|---|
| Display range | From 0.5 up to 260 km |
| Display resolution | 1 cm |
| Cursor resolution | From 1 cm |
| Sampling resolution | From 4 cm |
| Accuracy |
±1 m ±sampling resolution ±1.10-5 x distance
Excluding group index uncertainties
|
| Distance units | Km/m/mile/ft |
| Group index range | 1.30000 to 1.70000 in 0.00001 steps |
| Number of data points | Up to 256,000 data points |
| Mode | Automatic, manual, 2-point, 5-point and LSA |
|---|---|
| Display range | From 1.25 dB to 55 dB |
| Display resolution | 0.001 dB |
| Cursor resolution | From 0.001 dB |
| Attenuation linearity | ±0.03 dB/dB |
| Threshold | 0.01 to 1.99 dB in 0.01 dB step |
| Mode | Automatic or manual |
|---|---|
| Reflectance accuracy | ±2 dB |
| Display resolution | 0.01 dB |
| Threshold | –11 to –98 dB in 1 dB steps |
| Laser safety | Class 1 (IEC), Class 1 (21CFR) |
|---|---|
| Storage | Bellcore/Telcordia compatible Version 1.1 and Version 2.0 |
| Compatible platforms |
T-BERD/MTS-2000, −4000 V2, −5800
Web page also lists T-BERD/MTS-4000
|
| Weight | 430g (0.95 lb) |
|---|---|
| Dimensions (w x h x d) | 128 x 134 x 40 mm (5 x 5.28 x 1.58 in) |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- End-to-end link characterization with exact CWDM wavelengths
- Qualification of C-RAN, DAS and mobile fronthaul networks
- Testing new CWDM wavelength routes without disrupting traffic on active channels
- Pinpointing faults and their exact locations while in service
- End-to-end continuity verification with the continuous wave source
- CWDM network deployment and construction
Options & Accessories
| Option | Description |
|---|---|
| EUSCADS | Screw type adapter for PC connectors (SC) |
| EUFCADS | Screw type adapter for PC connectors (FC) — Also listed by the datasheet under APC (8°) connectors |
| EULCADS | Screw type adapter for PC connectors (LC) |
| EUSCADS-APC | Screw type adapter for APC (8°) connectors (SC) |
| EULCADS-APC | Screw type adapter for APC (8°) connectors (LC) |
| SLM | Smart Link Mapper — Optional; converts the OTDR trace into icons (splice, connector, MUX/DEMUX) |