ShockLine MS46524B 4-Port Performance Vector Network Analyzer, 50 kHz to 43.5 GHz
4-port ShockLine performance vector network analyzer in a 3U chassis, available in frequency ranges from 50 kHz up to 43.5 GHz.
- Frequency range
- 50 kHz to 8.5 GHz
- Frequency range
- 50 kHz to 20 GHz
- Frequency range
- 50 kHz to 43.5 GHz
- Frequency resolution
- 1 Hz
Overview
The Anritsu ShockLine MS46524B is a 4-port performance vector network analyzer (VNA) in a 3U high chassis. It is offered in three frequency ranges from 50 kHz to 43.5 GHz and measures 16 single-ended and mixed-mode S-parameters of passive multiport and differential devices.
Typical applications include characterizing and manufacturing multiport mobile network devices and equipment for 28 GHz and 39 GHz 5G applications, differential cables, high-speed data interconnects and system integration components. The frequency range is set by Option 10, 20 or 43, which cover RF to microwave frequencies.
Option 2 adds differential and mixed-mode real-time bandpass and lowpass time domain functionality. Lowpass time domain provides a TDR-like display that can show real impedance over distance or time. On the 8.5 GHz model, Option 61 adds bias tees so DC power can be supplied to devices during testing.
Software and remote control
The MS46524B uses the same GUI, software, command syntax, drivers and programming environments as the rest of the ShockLine family. It supports SCPI command programming over a LAN interface, and IVI-C drivers support common programming environments. Manual testing through the full graphical user interface requires a user-supplied touchscreen monitor, keyboard and mouse.
Key Features
- Specified performance to 43.5 GHz with Extended K ports
- Signal integrity testing of passive multiport and differential devices
- Wide dynamic range for measuring very low reflection artifacts
- Corrected directivity that minimizes measurement uncertainty
- SmartCal auto calibration unit reduces calibration and setup time
- Time domain with time gating option for TDR-like measurements
- LAN interface for remote control
- Common GUI and SCPI interface within the ShockLine family
- Compact 3U high chassis for efficient use of rack space
- Bias tee option for DUTs that need DC biasing
- Universal Fixture Extraction (UFX) software option with de-embedding tools for test fixture extraction
Specifications
|
Frequency range
MS46524B-010
|
50 kHz to 8.5 GHz |
|---|---|
|
Frequency range
MS46524B-020
|
50 kHz to 20 GHz |
|
Frequency range
MS46524B-043
|
50 kHz to 43.5 GHz |
| Frequency resolution | 1 Hz |
| Frequency accuracy |
± 0.1 ppm
At time of calibration
|
| Frequency stability |
± 0.02 ppm/24 hours; ± 0.2 ppm/1 month; ± 1.0 ppm/1 year; ±2.0 ppm/3 years
Typical
|
| > 50 MHz to 1.8 GHz |
140 dB (144 dB typical)
Degraded by 3 dB between ports 1 or 2 and ports 3 or 4 (typical)
|
|---|---|
|
> 8 GHz to 8.5 GHz
MS46524B-010
|
120 dB (127 dB typical) |
|
> 12 GHz to 25 GHz
MS46524B-020, MS46524B-043
|
117 dB (122 dB typical) |
|
> 25 GHz to 40 GHz
MS46524B-043
|
119 dB (126 dB typical) |
|
> 40 GHz to 43.5 GHz
MS46524B-043
|
110 dB (120 dB typical) |
| Output power range, >300 kHz to 6 GHz | –30 to +15 dBm (–30 to +17 dBm typical) |
|---|---|
| Output power range, > 8.5 GHz to 40 GHz | –30 to +6 dBm (–30 to +9 dBm typical) |
|
Output power range, > 40 GHz to 43.5 GHz
MS46524B-043
|
–30 to +2 dBm (–30 to +4 dBm typical) |
| Default output power | 0 dBm |
| Power accuracy at 0 dBm, 50 kHz to 8.5 GHz |
± 1.5 dB (± 0.5 dB)
Source is open loop below 300 kHz, ± 2 dB typical
|
| Power setting resolution |
0.01 dB
50 kHz to 43.5 GHz
|
| 4-port measurements | 16 single-ended S-parameters; 16 mixed-mode S-parameters (DD, CC, DC, CD); uses the superposition technique |
|---|---|
| Domains | Frequency Domain, Time (Distance) Domain (Option 2), Power Domain |
| Frequency sweep types | Linear, Log, CW, or Segmented |
| Maximum data points | 2 to 20,001 points |
| IF bandwidth | 10, 20, 30, 50, 70, 100, 200, 300, 500, 700 Hz; 1, 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 200, 300, 500 kHz |
| Channels and traces | 16 channels, each with up to 16 traces |
| Markers | 12 markers + 1 reference marker per trace |
| Averaging |
maximum number of averages = 4096
Point-by-point or sweep-by-sweep
|
| Directivity, 50 kHz to 4 GHz |
> 21 dB
Typical
|
|---|---|
| Port match, 50 kHz to 4 GHz |
> 17 dB
Typical; worst of source and load match
|
|
Test ports 1 through 4
MS46524B-010
|
N(f) |
|---|---|
|
Test ports 1 through 4
MS46524B-020
|
K(m) |
|
Test ports 1 through 4
MS46524B-043
|
Extended-K(m) |
| Damage input levels | +27 dBm maximum, 50 VDC maximum |
| USB ports | Six type A USB 2.0 Ports |
| LAN port |
Gigabit Ethernet
VXI-11 protocol, SCPI commands
|
|---|---|
| USB ports | Four type A USB 3.0 ports |
| Video output |
HDMI and Display Port
Touchscreen compatible
|
| 10 MHz In / Out | BNC(f) |
|
Bias inputs
MS46524B-061
|
BNC(f) (one input per port); 50 VDC maximum, 0.5 A maximum
Only available with Option 10
|
| AC power input |
350 VA maximum, 90 to 264 VAC, 47 to 63 Hz
Power factor controlled
|
| CPU | Intel Core i5/i7 |
| Dimensions (H x W x D) |
152 mm (5.98 in.) x 445 mm (17.52 in.) x 442 mm (17.4 in.)
Without rack mount option
|
|---|---|
|
Weight
MS46524B-010
|
< 13.6 kg (< 30 lb)
Typical weight for a fully-loaded unit
|
|
Weight
MS46524B-020, MS46524B-043
|
< 15.9 kg (< 35 lb)
Typical weight for a fully-loaded unit
|
| Environmental class | MIL-PRF-28800F Class 3 |
|---|---|
| Operating temperature range | 0 ºC to 50 ºC |
| Storage temperature range | –40 ºC to 71 ºC |
| Maximum relative humidity | 95 % RH at 30 ºC, non-condensing |
| Altitude | 4600 meters, operating and non-operating |
| Warranty |
1 year from the date of shipment
Instrument and built-in options
|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Differential cables, connectors and PCBs
- Automotive RF (FAKRA) connectors
- Driver assistance radar
- UE micro coaxial RF connectors
- UE antennas, switches and diplexers
- 5G network components
- Passive device testing
- Electromechanical components
- Switches, attenuators and couplers
- Filters, isolators and circulators
- Radar connectors
- Near-field and far-field antenna measurements
- System calibration
- Differential path-loss characterization
- Multi-port S-parameter and time domain measurements
- Amplifier characterization
- Wireless power transfer KQ product and maximum efficiency
- Photo receiver measurements
- Laser modulator measurements
- Optical transceiver measurements
Included
- Power cord
- Instructions on where to download software and related literature
Options & Accessories
| Option | Description |
|---|---|
| MS46524B-010 | 50 kHz to 8.5 GHz, type N(f) ports — Frequency option; one frequency option is required |
| MS46524B-020 | 50 kHz to 20 GHz, type K(m) Ruggedized ports — Compatible with 3.5 mm and SMA connectors |
| MS46524B-043 | 50 kHz to 43.5 GHz, type Extended-K(m) Ruggedized ports — Compatible with standard K (2.92 mm), 3.5 mm, and SMA connectors |
| MS46524B-001 | Rack Mount — Adds handles and removes feet for shelf-mounting into a 19 inch universal rack |
| MS46524B-002 | Time Domain with Time Gating |
| MS46524B-024 | Universal Fixture Extraction — Listed on the web page as MS46522B-024; the datasheet ordering information lists MS46524B-024 |
| MS46524B-061 | Bias Tees (Port 1, 2, 3, and 4) — Only available with Option 10 |
| MS46524B-097 | Accredited Calibration, with data |
| MS46524B-098 | Standard Calibration, ISO 17025 compliant, without data |