Anritsu MA24330A microwave CW USB power sensor, front view with K(m) connector
Anritsu / Power Sensors / USB Power Sensors
MA24330A

MA24330A Microwave CW USB Power Sensor, 10 MHz to 33 GHz

Microwave CW USB power sensor measuring average power from 10 MHz to 33 GHz over a 90 dB dynamic range.

Frequency Range
10 MHz to 33 GHz
Video Bandwidth
50 kHz
Datasheet

Overview

The Anritsu MA24330A is a microwave CW USB power sensor that provides average power measurements from 10 MHz to 33 GHz over 90 dB of dynamic range. It is a member of the MA243x0A series, which uses a single-path diode architecture and connects to a host through a USB 2.0 high-speed interface, so no benchtop power meter is required.

Digital processing in the sensor supports measurement speeds above 2,100 continuous power readings per second and above 5,600 buffered readings per second. The low-noise design removes the need to zero the sensor before taking measurements for most applications, and the 1 mW reference calibration step is eliminated.

Triggering and measurement modes

The sensor has internal and external triggering for time-based measurements, with external trigger latching for pulses as narrow as 20 ns. Continuous average, scope and list modes are available; list mode allows a sequence of frequency, aperture time and averaging settings to speed up automated test.

Control and compatibility

The MA24330A is controlled from a PC through remote programming commands or with PowerXpert, a software application supplied free of charge. It is also compatible with most Anritsu RF and microwave handheld instruments, which may require the high accuracy power meter software option (for example Option 19).

Damage protection of +26 dBm CW and +32 dBm for pulses shorter than 10 µs, together with a removable silicone protective covering, is intended to improve ruggedness in field use. Calibration is NIST traceable.

Key Features

  • Frequency range: 10 MHz to 33 GHz
  • Power measurement range: +20 dBm to −70 dBm
  • CW average power measurements
  • Fast measurement speed: >2,100 readings/s continuous, >5,600 readings/s buffered
  • Damage protection: +26 dBm CW, +32 dBm peak for pulses shorter than 10 µs
  • No zero required for signals above −45 dBm
  • Elimination of 1 mW reference calibration
  • Internal and external triggering for time-dependent power measurements
  • External trigger latching for pulses as narrow as 20 ns
  • NIST traceable calibrations, traceable to SI units via National Metrology Institutes
  • Compatible with Anritsu handheld instruments
  • Controlled from a PC with PowerXpert software or remote commands
  • Removable silicone protective covering for additional field durability
  • Worldwide calibration and service centers

Specifications

Frequency
Frequency Range 10 MHz to 33 GHz
K(m) Connector
Video Bandwidth 50 kHz
Power Measurement
Dynamic Range –70 dBm to +20 dBm
Damage Levels at RF Port +26 dBm, ±20 V DC
+32 dBm peak <10 μs pulse and 10 % duty cycle, minimum
Zeroing No zeroing required for signals > –50 dBm
Web page states no zero required for signals > –45 dBm; datasheet value used
Response
Signal Channel Rise Time 8 μs
characteristic
Sampling Rate 140 kS/s
VSWR
<50 MHz 1.9:1
50 to 150 MHz 1.17:1
>0.15 to 2 GHz 1.08:1
>2 to 6 GHz 1.16:1
>6 to 18 GHz 1.21:1
>18 to 33 GHz 1.29:1
Measurement Uncertainty, Average Power (25 °C to 35 °C)
–70 to <+15 dBm, ≤18 GHz 0.11
k=2, CW measurement after zero operation; includes calibration factor and linearity over temperature, excludes mismatch, zero set and drift, and noise
–70 to <+15 dBm, >18 GHz to 40 GHz 0.13
k=2, CW measurement after zero operation; applies up to 33 GHz for the MA24330A
+15 to +20 dBm, ≤18 GHz 0.14
k=2, CW measurement after zero operation
+15 to +20 dBm, >18 GHz to 40 GHz 0.17
k=2, CW measurement after zero operation; applies up to 33 GHz for the MA24330A
Measurement Uncertainty, Average Power (0 °C to 50 °C)
–70 to <+15 dBm, ≤18 GHz 0.14
k=2, CW measurement after zero operation. Web page lists 0.15 dB for this range; datasheet value used
–70 to <+15 dBm, >18 GHz to 40 GHz 0.17
k=2, CW measurement after zero operation; applies up to 33 GHz for the MA24330A
+15 to +20 dBm, ≤18 GHz 0.18
k=2, CW measurement after zero operation
+15 to +20 dBm, >18 GHz to 40 GHz 0.21
k=2, CW measurement after zero operation; applies up to 33 GHz for the MA24330A
Zero and Noise
Zero Set, –70 to –20 dBm 9.68E-11 W (–70.14 dBm)
k=3; one hour warm-up then Zero operation, 256 averages, 40 ms aperture, temperature within ±1 °C; valid at 30 °C ± 5 °C
Zero Set, >–20 to 0 dBm 4.95E-09 W (–53.05 dBm)
k=3; valid at 30 °C ± 5 °C
Zero Set, >0 to +20 dBm 1.56E-08 W (–48.08 dBm)
k=3; valid at 30 °C ± 5 °C
Zero Drift, –70 to –20 dBm 8.90E-11 W (–70.50 dBm)
Two sigma value of the reported power over one hour; valid at 30 °C ± 5 °C
Zero Drift, >–20 to 0 dBm 4.14E-09 W (–53.83 dBm)
Two sigma value of the reported power over one hour; valid at 30 °C ± 5 °C
Zero Drift, >0 to +20 dBm 1.72E-08 W (–47.65 dBm)
Two sigma value of the reported power over one hour; valid at 30 °C ± 5 °C
Noise, –70 to –20 dBm 3.53E-11 W (–74.52 dBm)
Two sigma noise at 10.2 seconds of integration time; k=3
Noise, >–20 to 0 dBm 6.51E-11 W (–71.86 dBm)
Two sigma noise at 10.2 seconds of integration time; k=3
Noise, >0 to +20 dBm 6.30E-10 W (–62.01 dBm)
Two sigma noise at 10.2 seconds of integration time; k=3
Trigger
Source Bus, Continuous, Internal, External
Bus trigger is not available in PowerXpert application
Arm Type (for Internal/External) Auto, Single, Multiple, Standby
Internal Trigger
Dynamic Range –35 dBm to +20 dBm
Level Accuracy ±0.5 dB
characteristic
Slope Positive or Negative
Delay Range –5 ms to +10 s
Delay Resolution 10 μs
Hysteresis 0 dB to 10 dB, with 0.1 dB resolution
Trigger Hold Off 0 s to 10 s, with 0.01 ms resolution
External Trigger
External Trigger Input MCX (female), 5.5 V maximum
Input Impedance 4 kΩ
nominal
Type TTL/CMOS
Slope Positive or Negative
Delay Range –5 ms to +10 s
Delay Resolution 10 μs
High Level Input Voltage 2.3 V min, 3.0 V max
Low Level Input Voltage 1.3 V min, 1.6 V max
Latency 7.1 μs max
Time delay between the defined edge of the applied trigger and the sensor switching into the triggered state
Trigger Pulse Width 20 ns min
Trigger Repetition Period 7.1 μs min
Trigger Holdoff 0 s to 10 s with 0.01 ms resolution
System
Measurand Average power
Measurement Resolution 0.01 dB max via PowerXpert, 0.001 dB max via remote command
Offset Correction –100 dB to +150 dB
Available only through the PowerXpert application; no remote command in the sensor firmware
Averaging Auto, Manual
Averaging Type Moving, Repeat
Number of Averages (Manual) 1 to 65,536
Maximum in Continuous Average mode is 65,536; in Scope mode the maximum equals 16,777,216 divided by the number of data points
Auto Average Resolution 1 dB, 0.1 dB, 0.01 dB
0.001 dB averaging resolution is available via remote operation, not with the PowerXpert application
Auto Average Source Scope Data Point Number: 1 to 16,384
Continuous Average Mode
Duty Cycle Correction 0.01 % to 100 %
Aperture Time 0.01 ms to 1 s
Measurement Speed, Continuous >2,100 readings/s
Minimum aperture, one average; throughput at the A end of the USB cable, may vary with host CPU speed and load
Measurement Speed, Buffered >5,600 readings/s
Minimum aperture, one average; throughput at the A end of the USB cable, may vary with host CPU speed and load
Buffer Size 8192
Scope Mode
Capture Time 0.01 ms to 1 s
Data Points 1 to 16,384
Resolution 0.01 ms max
List Mode
Number of Measurements 1 to 1000
Input Parameters Frequency (GHz), aperture time (ms), averages
PowerXpert PC Requirements
Processor and RAM Minimum: Equivalent to Intel Pentium III with 1 GB RAM or Intel Pentium IV with 512 MB RAM; Recommended: Equivalent to Intel Pentium IV with 1 GB RAM
PowerXpert version 3.0 or greater
Operating System Microsoft Windows 8, Windows 7, and Windows XP
Hard-Disk Free Space 100 MB minimum
Display Resolution 1024 × 768 minimum
Interface USB 2.0 high speed
General
RF Connector K male
Interface to Host USB 2.0 high speed
USB Micro-B port for connectivity to host (PC or Anritsu handheld instrument)
Current Consumption 410 mA to 450 mA
characteristic (20 ºC to 30 ºC)
Size 110 mm x 46 mm x 25.6 mm
Excluding K connector and silicone protective covering
Weight 397 g (0.88 lb)
Warranty 1 year
Calibration Cycle 12 months
Anritsu recommended calibration interval
Warm-Up Time 60 minutes
Environmental
Operating Temperature Range 0 ºC to 50 ºC
Tests performed per MIL-PRF-28800F (Class 3)
Storage Temperature Range –40 ºC to +71 ºC
Humidity 45 % relative humidity at 50 ºC; 75 % relative humidity at 40 ºC; 95 % relative humidity at 30 ºC
non-condensing
Altitude 4600 m
operational max
Shock 30 g half-sine, 11 ms duration
Vibration Sinusoidal: 5 Hz to 55 Hz, 3 g max; Random: 10 Hz to 500 Hz, Power Spectral Density: 0.03 g²/Hz
Regulatory Compliance
European Union EMC 2014/30/EU, EN 61326:2013, CISPR 11/EN 55011, IEC/EN 61000-4-2/3/4/5/6/8/11; Low Voltage Directive 2014/35/EU; Safety EN 61010-1:2010; RoHS Directive 2011/65/EU
Australia and New Zealand RCM AS/NZS 4417:2012
South Korea KCC-REM-A21-0004

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • General purpose power measurement
  • Aerospace and defense
  • Satellite communications
  • Wireless communications
  • Production test
  • Automated test with list mode

Included

  • 10585-00021 Quick Start Guide
  • 2000-1605-R 1.5 m BNC(m) to MCX(m) cable
  • 2000-2010-R 1.83 m USB A to Micro-B cable

Options & Accessories

Option Description
MA24330A-097 Option 97: ISO/IEC 17025 and ANSI/NCSL Z540-1 or ANSI/NCSLI Z540.3 calibration — Includes test report, uncertainty data, and accreditation symbol
MA24330A-098 Option 98: Standard calibration ISO/IEC 17025 and ANSI/NCSL Z540-1
MA24330A-099 Option 99: Premium calibration ISO/IEC 17025 and ANSI/NCSL Z540-1 — Includes test report and uncertainty data
01-201 Calibrated torque wrench for K and V connectors
41KB-3 Precision fixed attenuator, DC to 26.5 GHz, 3 dB, 50 Ω, K(m) to K(f)
41KB-6 Precision fixed attenuator, DC to 26.5 GHz, 6 dB, 50 Ω, K(m) to K(f)
41KB-10 Precision fixed attenuator, DC to 26.5 GHz, 10 dB, 50 Ω, K(m) to K(f)
41KB-20 Precision fixed attenuator, DC to 26.5 GHz, 20 dB, 50 Ω, K(m) to K(f)
41KC-3 Precision fixed attenuator, DC to 40 GHz, 3 dB, 50 Ω, K(m) to K(f)
41KC-6 Precision fixed attenuator, DC to 40 GHz, 6 dB, 50 Ω, K(m) to K(f)
41KC-10 Precision fixed attenuator, DC to 40 GHz, 10 dB, 50 Ω, K(m) to K(f)
41KC-20 Precision fixed attenuator, DC to 40 GHz, 20 dB, 50 Ω, K(m) to K(f)
43KB-3 Precision fixed attenuator, DC to 26.5 GHz, 3 dB, 50 Ω, K(m) to K(f)
43KB-6 Precision fixed attenuator, DC to 26.5 GHz, 6 dB, 50 Ω, K(m) to K(f)
43KB-10 Precision fixed attenuator, DC to 26.5 GHz, 10 dB, 50 Ω, K(m) to K(f)
43KB-20 Precision fixed attenuator, DC to 26.5 GHz, 20 dB, 50 Ω, K(m) to K(f)
43KC-3 Precision fixed attenuator, DC to 40 GHz, 3 dB, 50 Ω, K(m) to K(f)
43KC-6 Precision fixed attenuator, DC to 40 GHz, 6 dB, 50 Ω, K(m) to K(f)
43KC-10 Precision fixed attenuator, DC to 40 GHz, 10 dB, 50 Ω, K(m) to K(f)
43KC-20 Precision fixed attenuator, DC to 40 GHz, 20 dB, 50 Ω, K(m) to K(f)
33KFKF50B Precision coaxial adapter, DC to 40 GHz, 50 Ω, K(f) to K(f)
33KKF50B Precision coaxial adapter, DC to 40 GHz, 50 Ω, K(m) to K(f)
34NKF50 Precision coaxial adapter, DC to 18 GHz, 50 Ω, N(m) to K(f)
34NFKF50 Precision coaxial adapter, DC to 18 GHz, 50 Ω, N(f) to K(f)

Documents & Resources