VIAVI OneExpert ONX-700 series handheld tester, side view
VIAVI / ONX-720/730 / Handheld
ONXF-730-PON-42-204-NTX

OneExpert HFC ONXF-730-PON-42-204-NTX DOCSIS 3.1 and PON Selective Power Meter Package, 42/204 MHz

OneExpert HFC ONX-730 new unit with PON selective power meter, VFL, optical loss and a 42/204 MHz DOCSIS 3.1 module for 10 Gbps service testing.

Fiber optic testing
PON Selective Optical Power Meter, VFL, Optical Loss
Service testing
OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck
DOCSIS module
ONX-CATV-D31-S-4220-1012 module (42/204 MHz D3.1)
Software package
ONX 730 NTX Package
Datasheet

Overview

The VIAVI ONXF-730-PON-42-204-NTX is a new-unit ordering package of the OneExpert HFC ONX-730 handheld tester. It combines DOCSIS, Ethernet, PON and WiFi 7 testing in one instrument and validates service throughput up to 10 Gbps, with VIAVI Test Process Automation (TPA) providing one-button OneCheck workflows for technicians.

This package is configured for PON and cable service activation. It includes the PON Selective Optical Power Meter, a Visual Fault Locator, Optical Loss mode, OneCheck Ethernet, OneCheck WiFi and 10G SpeedCheck, together with the ONX-CATV-D31-S-4220-1012 DOCSIS 3.1 module for 42/204 MHz upstream and 1.0 GHz/1.2 GHz downstream networks and the ONX 730 NTX software package.

Optical testing

The selective power meter measures coexistent PON wavelengths separately through a dedicated SC/APC optical port. It reads the PON-ID to confirm the connection to the expected OLT. With the optional TruePON software, it verifies Total Optical Loss (TOL), PON-ID, OLT connectivity and received power based on the ODN class.

DOCSIS and RF

The ONX-720/730 continues the RF and DOCSIS testing capabilities of the ONX-620/630, including support for existing RF modules. The NTX package includes the Return Signal Generator with Loopback and Ingress Expert as standard.

Design

The unit is IP54 rated, weatherproof and drop-tested. Its modular design supports later 25G/50G PON and DOCSIS 4.0 upgrades. It has integrated GPS, StrataSync and mobile app support, and a field-replaceable 96 W/hr battery.

Key Features

  • PON Selective Optical Power Meter with SC/APC connection
  • Visual Fault Locator (1 mW)
  • Optical Loss mode (set/clear reference with delta)
  • Broadband power capability for selective PON hardware
  • OneCheck Ethernet and OneCheck WiFi 7 automated pass/fail workflows
  • VIAVI SpeedCheck to 5 Gbps and 10 Gbps
  • ONX-CATV-D31-S-4220-1012 DOCSIS 3.1 module (42/204 MHz)
  • ONX 730 NTX software package
  • Return Signal Generator with Loopback and Ingress Expert included
  • PON-ID reading to validate connection to the expected OLT
  • Optional TruePON PON-ID analysis with OLT-ID and loss
  • Optional OneCheck PON with GPON/XGS-PON emulation using VIAVI SFP
  • Fiber scope support with Auto Analysis and defect detection
  • IP54 rated, drop-tested, modular design upgradeable for 25G/50G PON and DOCSIS 4.0
  • Integrated GPS, StrataSync and VIAVI Mobile Tech app support
  • Field-replaceable 96 W/hr Li-Ion battery

Specifications

Package Contents
Fiber optic testing PON Selective Optical Power Meter, VFL, Optical Loss
Service testing OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck
DOCSIS module ONX-CATV-D31-S-4220-1012 module (42/204 MHz D3.1)
42/204 MHz Upstream 1.0 GHz/1.2 GHz Downstream DOCSIS 3.1 Packages
Software package ONX 730 NTX Package
Package and Feature Matrix
Broadband Optical Power Meter N/A
PON Selective Optical Power Meter Standard
TruePON PON-ID Analysis with OLT-ID and Loss Optional
Broadband Power Capability for Selective PON Hardware Standard
Optical Loss Mode (Set/clear Ref with Delta) Standard
Visual Fault Locator (1 mW) Standard
OneCheck WiFi7 Standard
OneCheck Ethernet Standard
Optical Ethernet Testing over SFP+ Optional
OneCheck PON w/Emulation – GPON/XGS PON using VIAVI SFP Optional
VIAVI SpeedCheck – 5 Gbps / 10 Gbps Standard
Ookla Speedtest – 5 Gbps / 10 Gbps Optional
VIAVI TrueSpeed – 5 Gbps / 10 Gbps Optional
iPerf Speedtest – 5 Gbps / 10 Gbps Optional
Smart Access Anywhere - Remote Connectivity Optional
NTX Software Package Standard
HomeTDR Optional
Home Leakage Test Optional
Return Signal Generator w/Loopback Standard
Reverse Sweepless Sweep Optional
QAM Video MPEG Verification Optional
Ingress Expert Standard
Field View w/RSG Optional
Ethernet
Standard IEEE 802.3 100M, 1G, 2.5G, 5G, and 10G Ethernet
Test results Ethernet Frames, IP Connectivity, Ping, Trace route, Web Connectivity, Speed Test up to 10 Gbps
10GBase-T RJ-45 Electrical 100M, 1G, 2.5G, 5G, 10G
SFP+ Optical Ethernet 1G, 10G (SFP dependent)
Optional
SFP+ Electrical Ethernet 100M, 1G, 2.5G, 5G, 10G
Optional
WiFi
OneCheck WiFi (Connected Mode) WiFi - 7 2x2 (802.11 a/b/g/n/ac/ax/be) 2.4, 5, 6 GHz bands
Test results Signal strength (RSSI), Standard, Width, Max Router PHY Rate, IP/Web connectivity, Throughput Tests (SpeedCheck, Ookla Speedtest, iPerf)
Throughput/Performance Tests
TCP Throughput Test VIAVI SpeedCheck: 5 Gbps, 10 Gbps; Ookla Speedtest: 5 Gbps, 10 Gbps; VIAVI TrueSpeed (RFC-6349): 5 Gbps, 10 Gbps
Performance Up to 10 Gbps for SpeedCheck, Ookla Speedtest, TrueSpeed, iPerf client: 5 Gbps, 10 Gbps
Test results Delay, Upstream and Downstream Bit Rates
Bluetooth Communications
Communication interface Bluetooth v5.0, BLE 2.0
Smart device support VIAVI Mobile Tech app, Android 8 or newer, iOS12 or newer
Recommendation
Optical Fiber Scope Support
USB optical fiber scope P5000i, FiberChek Probe
Results for zone defects Pass/Fail
Results for zone scratches Pass/Fail
Low Mag Field-of-View (FOV) Horizontal 740 μm, Vertical 550 μm
High Mag Field-of-View (FOV) Horizontal 370 μm, Vertical 275 μm
Particle size detection <1 μm
Power source USB port
Selective PON Power Meter
Photo diode InGaAs
Spectral range Passband (1260…1500 nm, 1540…1650 nm)
Wavelength setting 1342, 1358, 1490, 1577 nm; Dual: 1490/1577, 1342/1577, 1358/1577 nm; Broadband: 1270...1650 nm, Custom step size 1 nm
Broadband: in Broadband Mode (activated SW option required)
Resolution 0.01 dB, 0.001 µW
Measurement range for power level -45…+3 dBm
Max. power level +15 dBm
Measurement uncertainty 1490 nm: ±0.5 dB/±12 %; 1577 nm: ±0.5 dB/±12 %; 1342 nm: ±0.5 dB/±12 %; 1358 nm: ±0.5 dB/±12 %; Broadband: ±0.5 d/±5 %
Under reference conditions: -2 dBm (CW), nominal wavelength, 23 °C ±3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9 µm core, 8° APC), with SC/APC connectors; Broadband in Broadband Mode (SW option required)
Measurement range for PON-ID GPON: -30...0 dBm; XGS-PON: -25...0 dBm
Number of calibrated wavelengths 2 (1490, 1577 nm)
Tone detection 270 Hz, 330 Hz, 1 kHz, 2 kHz
Future optional capability; in Broadband Mode (activated SW option required); when used with VIAVI Light Source and received optical power level > -50 dBm
Connection SC/APC
Visual Fault Locator (VFL)
Fiber compatibility Single-mode, Multimode
Wavelength 650 nm (visible)
Output modes Continuous and flashing
Connector interface Universal 2.5 mm (fixed)
Controls On/Off Continuous/Flashing
Output power 1 mW
Laser safety rating Class 2
Range (maximum) 7 km
VFL range depends on many factors, including fiber quality/loss
General
Size 5.0 x 11.1 x 4.25 in (W x L x H)
ONX-720 and ONX-730 with RF Module
Weight 3.15 kg (6.9 lb)
ONX-720 and ONX-730 with RF Module, without protective case
Operating temperature range Non-Charging: -10°C to 50°C; Battery Charging: 0°C to 40°C
Storage temperature range -20°C to 60°C
Operating humidity range 10% to 90% RH, non-condensing
For indoor/outdoor use IP54 light rain (0.5 in/hr; 1.27 cm/hr)
Drop rating 1 m (3.3 ft) onto concrete
Operating altitude 4000 m max
Pollution 2°
RF immunity 8.5 V/m
For CATV measurements
DC input power 12 V@5 A
DC charge port 2.5 mm barrel
Battery 96 W/hr Li-Ion rechargeable battery, Field replaceable
Battery charge time 4 Hrs (90%) 6-8 Hrs 100% (AC charger)
Battery life 3-5 day typical usage for installation technicians
10 installs a day
USB host port(s) USB-C, USB-A (USB 3.0)
DOCSIS/RF Frequency
Range 0.5 to 1,218 MHz
Accuracy ±10 ppm
typical @25°C
Downstream Analysis — Port 1
Max input power 60 dBmV total integrated power
Operation on powered TAP Operate with up to 90 VAC/DC on input port
Power detection/notification Notify of AC/DC power presence on port 1 above 2 Volts
Return loss >9 dB
Auto channel plan builder Auto detection of channels (analog, digital, QAM, OFDM)
Upstream Analysis — Port 2
Ingress spectrum scan 0.5–204 MHz, calibrated range 4-204 MHz
Sensitivity −45 dBmV
RBW 300 kHz
Min detectable level upstream −55 dBmV
Dynamic range 50 dB
Max total integrated power 55 dBmV, 4–10 MHz, 60 dBmV, 10 to 204 MHz
Accuracy ±2 dB
typical at 25°C
Sampling rate Hyper Spectrum FFT Gapless technology - no missed samples, spans 0.5 to 110 MHz, 110 to 160 MHz, and 160 to 204 MHz
Return loss >9.5 dB
Power detection/notification Notify of AC/DC power presence on port 2 above 2 Volts
Analog Channel Measurement
Standards NTSC, PAL, SECAM
Min detectable signal −50 dBmV
single channel
Level accuracy ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C
RBW 300 kHz
Downstream Digital Channel Analysis
Calibrated power levels -20 dBmV to +50 dBmV
Level accuracy ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C
Modulation(s) 64, 128, and 256 QAM, OFDM
Symbol rates Annex A: 5.057 to 6.952 MSPS for 64, 128, and 256 QAM; Annex B: 5.057 MSPS for 64 QAM and 5.361 MSPS for 256 QAM; Annex C: 5.274 MSPS for 64 QAM, and 5.361 MSPS for 256 QAM
Regional demods DVB-C
MER specified range 21 to 40 dB, 64 QAM; 28 to 40 dB, 256 QAM; 16 to 44 dB, OFDM
At −5 to +20 dBmV; MER range declines as input levels decrease. Expected MER range at MINLOCK level of –15 dBmV is >30 dB MER
MER max displayable range 50 dB
MER resolution 0.1 dB
MER accuracy ±2 dB
typical at 25°C
Minimum lock level −15 dBmV
BER — Channel Check and DOCSIS Check mode Down to 1E-9 (pre and post FEC)
BER — OneCheck Mode Down to 1E-8 (pre and post FEC) Std. 1E-9 user selectable
Interleaver depth 128, 8 max
OFDM Signal Performance Metrics
OFDM channels 24-192 MHz wide − up to 3 active OFDM channels
Level — max, min, average, standard deviation Relative to a 6 MHz carrier per CableLabs®
MER — max, min, average, standard deviation, percentile 16 to 44 dB
MER channel band graph Max, min, avg across entire OFDM carrier MER per subcarrier
ICFR In-carrier frequency response (dB)
Profile analysis Profiles A, B, C, D, NCP, and PLC (more profiles as implemented); Lock status, code word errors (corrected and uncorrected)
RF Module Inputs/Outputs
RF (2) F connectors replaceable
Port 1 Downstream 54/85/108/258 MHz depending on diplexer
Port 2 Upstream 0.5–204 MHz and TDR
MoCA filter All models have MoCA triplexer to filter out MoCA signals below the highest downstream frequency
Sweep
Forward sweep telemetry frequency Diplexer dependent 50-1,218 MHz
Input port: Port 1
Forward sweep compatibility SCU-1800
Reverse sweep output transmit port Port 1 or Port 2 (user selectable)
Port 1 sweep frequency range Diplexer dependent 5-42/5-65/5-85/5-204 MHz
Port 2 sweep frequency range 5-204 MHz
Reverse sweep compatibility SCU-1800 or DAA/RPHY via XperTRAK

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Multi-gig residential service activation
  • Small business service installation
  • DOCSIS service turn-up and troubleshooting
  • PON network validation and OLT link verification
  • WiFi 7 service delivery testing
  • Ethernet throughput testing up to 10 Gbps
  • Upstream ingress troubleshooting

Included

  • PON Selective Optical Power Meter
  • VFL
  • Optical Loss
  • OneCheck Ethernet
  • OneCheck WiFi
  • 10G SpeedCheck
  • ONX-CATV-D31-S-4220-1012 module (42/204 MHz D3.1)
  • ONX 730 NTX Package
  • Protective Fitted Case
  • Cat6A jumper M-F and M-M

Options & Accessories

Option Description
ONXF-SW-OC-WIFI OneCheck WiFi Software option
ONXF-SW-OC-ETHERNET OneCheck Ethernet Software option
ONXF-SW-SFP-ETH Enable SFP+ port for Optical Ethernet testing over VIAVI supported SFP’s
ONXF-SW-TRUEPON TruePON software option — Requires PON selective HW
ONXF-SW-PON-BROADBAND Enable Selective Power Meter to operate in broadband mode
ONXF-SW-OPTICAL-LOSS Optical Loss test mode option to save reference and calculate loss
ONXF-SW-OC-PON OneCheck PON – PON testing via GPON/XGSPON SFP+
ONXF-SW-OC-GPON-EMUL GPON Emulation for live service testing on GPON network
ONXF-SW-OC-XGSPON-EMUL GPON Emulation for live service testing on GPON network — Description as printed in the datasheet
ONX-SMART-ACCESS Smart Access Anywhere
ONXF-SW-OOKLA-SPD-5G-1Y ONX Ookla Speedtest to 5 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-5G-3Y ONX Ookla Speedtest to 5 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-5G-5Y ONX Ookla Speedtest to 5 Gbps 5 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-5G ONX Ookla Speedtest to 5 Gbps
ONXF-SW-OOKLA-SPD-10G-1Y ONX Ookla Speedtest to 10 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-10G-3Y ONX Ookla Speedtest to 10 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-10G-5Y ONX Ookla Speedtest to 10 Gbps 5 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-10G ONX Ookla Speedtest to 10 Gbps
ONXF-SW-TRUESPEED-5G-1Y ONX TrueSpeed to 5 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-TRUESPEED-5G-3Y ONX TrueSpeed to 5 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-TRUESPEED-5G ONX TrueSpeed to 5 Gbps permanent License
ONXF-SW-TRUESPEED-10G-1Y ONX TrueSpeed to 10 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-TRUESPEED-10G-3Y ONX TrueSpeed to 10 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-TRUESPEED-10G ONX TrueSpeed to 10 Gbps Permanent License
ONXF-SW-IPERF-5G-1Y ONX iPerf test to 5 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-IPERF-5G-3Y ONX iPerf test to 5 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-IPERF-5G ONX iPerf test to 5 Gbps Permanent License
ONXF-SW-IPERF-10G-1Y ONX iPerf test to 10 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-IPERF-10G-3Y ONX iPerf test to 10 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-IPERF-10G ONX iPerf test to 10 Gbps permanent License
ONX-CATV-SW-HL-LKG Home Leakage Software Option
ONX-CATV-SW-HOMETDR Home TDR Software Option
ONX-CATV-SW-REVSWPLSSWP Reverse Sweepless Sweep Option for ONX 730’s
ONX-CATV-SW-QAM-VIDEO QAM Video MPEG Verification Option
ONX-CATV-SW-RP-SNR-OCE Return Path SNR in OneCheck Expert - OneExpert CATV
ONX-CATV-SW-FV-RSG PathTrak Fieldview with Return Signal Generator for ONX 730s
ONX-CATV-FWD-SWEEP Active Forward Sweep
ONX-CATV-REV-SWEEP Active Reverse Sweep
NSC-SFP-GPON GPON SFP for GPON emulation
NSC-SFP-XGSPON XGSPON SFP+ for XGSPON emulation
NSC-SFP-850-1G-10G Optical Ethernet SFP + 850 nm SR 1G and 10G
NSC-SFP-1310-1G-10G Optical Ethernet SFP + 1310 nm LR 1G and 10G
NSC-SFP-1550-1G-10G Optical Ethernet SFP + 1550 nm ER 1G and 10G
AC-CHARGER Replacement AC charger (no power cord)
AC-CAR-CHARGER Car Charger
CC-034601 Large Carrying Case
1019-00-1366 Strand Hook
ONXF-HANDSTRAP Handstrap for use on unit without a case
ONXF-HFC-BATT-96WHR Replacement 96 W/Hr Battery
ONXF-DISPLAY-PROTECTOR-5P Replacement screen protector (5 pack)
ONXF-ETH-ADAPT-M-F Ethernet Cat6a M-F adapter 0.5 m
NSC-ETHERNET-CABLE Ethernet Cat6a M-M Patch Cable
ONXF-CATV-D31-ADAPTR Module adapter for existing D3.1 modules for ONX-720/730
ONXF-HFC-CASE Fitted protective case for ONX-720/730 with DOCSIS 3.1

Documents & Resources