OneExpert HFC ONXF-730-BB-42-85-SWX DOCSIS 3.1 and Fiber Service Tester with Broadband Power Meter
OneExpert HFC ONX-730 SWX package with 42/85 MHz DOCSIS 3.1 module, broadband optical power meter, VFL and 10 Gbps Ethernet and WiFi 7 testing.
- Standard
- IEEE 802.3 100M, 1G, 2.5G, 5G, and 10G Ethernet
- Test Results
- Ethernet Frames, IP Connectivity, Ping, Trace route, Web Connectivity, Speed Test up to 10 Gbps
- 10GBase-T RJ-45 Electrical
- 100M, 1G, 2.5G, 5G, 10G
- SFP+ Optical Ethernet
- 1G, 10G (SFP dependent)
Overview
The VIAVI OneExpert HFC ONXF-730-BB-42-85-SWX is a new-unit ordering package of the OneExpert HFC (ONX-720/730) handheld tester. It combines an ONX-730 mainframe with the SWX software package, a broadband optical power meter, a visual fault locator, optical loss mode and the ONX-CATV-D31-S-4285-1012 DOCSIS 3.1 module for 42/85 MHz upstream and 1.0 GHz/1.2 GHz downstream networks.
The OneExpert HFC platform validates DOCSIS, Ethernet, PON and WiFi 7 throughput up to 10 Gbps. OneCheck Ethernet, OneCheck WiFi and VIAVI SpeedCheck at 5 and 10 Gbps are standard, and Test Process Automation (TPA) provides guided, one-button pass/fail workflows with geo-tagged saved results.
Optical testing
The broadband power meter covers 800 to 1650 nm with eight calibrated wavelengths and a universal 2.5 mm connection. In this package it is complemented by an optical loss mode for setting and clearing a reference and calculating loss, a 650 nm visual fault locator, and support for USB fiber inspection scopes with automatic pass/fail analysis.
DOCSIS and RF
The ONX-720/730 retains the RF and DOCSIS test capabilities of the ONX-620/630 and supports existing RF modules. On the ONX-730 SWX configuration, the Return Signal Generator with loopback and Ingress Expert are included, and reverse sweepless sweep, QAM video MPEG verification and Field View with RSG are available as options.
Construction
The unit is IP54 rated, drop-tested to 1 m onto concrete, and runs from a field-replaceable 96 W/hr Li-Ion battery. Its modular design is intended to support upgrades to 25G/50G PON and DOCSIS 4.0. GPS, StrataSync and the VIAVI Mobile Tech app are also supported.
Key Features
- ONX-730 mainframe with SWX software package
- ONX-CATV-D31-S-4285-1012 DOCSIS 3.1 module (42/85 MHz)
- Broadband optical power meter with VFL and optical loss mode
- OneCheck Ethernet and OneCheck WiFi included
- VIAVI SpeedCheck to 5 Gbps and 10 Gbps included
- Return Signal Generator with loopback included
- Ingress Expert included
- Unified OneCheck workflow automates pass/fail for DOCSIS, Ethernet, WiFi and PON
- 10GBase-T RJ-45 Ethernet testing at 100M, 1G, 2.5G, 5G and 10G
- WiFi 7 2x2 testing in the 2.4, 5 and 6 GHz bands
- Fiber scope support with Auto Analysis for defect detection
- Smart Access Anywhere remote coaching and training (optional)
- IP54 rated, drop-tested, modular design
- Integrated GPS, StrataSync and mobile app support
- Upgrade path for 25G/50G PON and DOCSIS 4.0
- Field-replaceable 96 W/hr battery for multi-day use
Specifications
| Standard | IEEE 802.3 100M, 1G, 2.5G, 5G, and 10G Ethernet |
|---|---|
| Test Results | Ethernet Frames, IP Connectivity, Ping, Trace route, Web Connectivity, Speed Test up to 10 Gbps |
| 10GBase-T RJ-45 Electrical | 100M, 1G, 2.5G, 5G, 10G |
| SFP+ Optical Ethernet |
1G, 10G (SFP dependent)
Optional
|
| SFP+ Electrical Ethernet |
100M, 1G, 2.5G, 5G, 10G
Optional
|
| OneCheck WiFi (Connected Mode) | WiFi - 7 2x2 (802.11 a/b/g/n/ac/ax/be) 2.4, 5, 6 GHz bands |
|---|---|
| Test Results | Signal strength (RSSI), Standard, Width, Max Router PHY Rate, IP/Web connectivity, Throughput Tests (SpeedCheck, Ookla Speedtest, iPerf) |
| TCP Throughput Test |
VIAVI SpeedCheck: 5 Gbps, 10 Gbps; Ookla Speedtest: 5 Gbps, 10 Gbps; VIAVI TrueSpeed (RFC-6349): 5 Gbps, 10 Gbps
SpeedCheck standard; Ookla Speedtest and TrueSpeed optional
|
|---|---|
| Performance | Up to 10 Gbps for SpeedCheck, Ookla Speedtest, TrueSpeed, iPerf client: 5 Gbps, 10 Gbps |
| Test Results | Delay, Upstream and Downstream Bit Rates |
| Communication Interface | Bluetooth v5.0, BLE 2.0 |
|---|---|
| Smart Device Support |
VIAVI Mobile Tech app; Android 8 or newer; iOS 12 or newer
Recommendation
|
| USB Optical Fiber Scope | P5000i, FiberChek Probe |
|---|---|
| Results for Zone Defects | Pass/Fail |
| Results for Zone Scratches | Pass/Fail |
| Low Mag Field-of-View (FOV) | Horizontal 740 μm, Vertical 550 μm |
| High Mag Field-of-View (FOV) | Horizontal 370 μm, Vertical 275 μm |
| Particle Size Detection | <1 μm |
| Power Source | USB port |
| Photo Diode | InGaAs |
|---|---|
| Spectral Range | Broadband (800…1650 nm) |
| Wavelength Setting | 850, 980, 1310, 1490, 1550, 1577, 1625, 1650 nm; Custom 800…1650 nm, step size 1 nm |
| Resolution | 0.01 dB, 0.001 μW |
| Measurement Range for Power Level | -65…+10 dBm |
| Max. Power Level | +16 dBm |
| Measurement Uncertainty |
±0.2 dB/±5% (intrinsic)
Under reference conditions: -11 dBm (CW), 1310 nm ±1 nm, 23 °C ±3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9 µm core, 8° APC), when used with SC/PC connectors
|
| Number of Calibrated Wavelengths | 8 (850, 980, 1310, 1490, 1550, 1577, 1625, 1650 nm) |
| Tone Detection |
270 Hz, 330 Hz, 1 kHz, 2 kHz
Future optional capability; received optical power level ≥ -50 dBm
|
| Connection | UPP 2.5 mm |
| Fiber Compatibility | Single-mode, Multimode |
|---|---|
| Wavelength | 650 nm (visible) |
| Output Modes | Continuous and flashing |
| Connector Interface | Universal 2.5 mm (fixed) |
| Controls | On/Off Continuous/Flashing |
| Output Power | 1 mW |
| Laser Safety Rating | Class 2 |
| Range (maximum) |
7 km
VFL range depends on many factors, including fiber quality/loss
|
| Size |
5.0 x 11.1 x 4.25 in (W x L x H)
ONX-720 and ONX-730 with RF Module
|
|---|---|
| Weight |
3.15 kg (6.9 lb)
ONX-720 and ONX-730 with RF Module, without protective case
|
| Operating Temperature Range | Non-Charging: -10°C to 50°C; Battery Charging: 0°C to 40°C |
| Storage Temperature Range | -20°C to 60°C |
| Operating Humidity Range | 10% to 90% RH, non-condensing |
| For Indoor/Outdoor Use | IP54 light rain (0.5 in/hr; 1.27 cm/hr) |
| Drop Rating | 1 m (3.3 ft) onto concrete |
| Operating Altitude | 4000 m max |
| Pollution | 2° |
| RF immunity |
8.5 V/m
For CATV measurements
|
| USB Host Port(s) | USB-C, USB-A (USB 3.0) |
| DC Input Power | 12 V@5 A |
|---|---|
| DC Charge Port | 2.5 mm barrel |
| Battery | 96 W/hr Li-Ion rechargeable battery, Field replaceable |
| Battery Charge Time | 4 Hrs (90%) 6-8 Hrs 100% (AC charger) |
| Battery Life |
3-5 day typical usage for installation technicians
10 installs a day
|
| Included Module |
ONX-CATV-D31-S-4285-1012 module (42/85 MHz D3.1)
42/85 MHz Upstream 1.0 GHz/1.2 GHz Downstream DOCSIS 3.1 package
|
|---|---|
| Diplexer (42 MHz) | upstream 4-42 MHz; downstream 54–1,004 MHz |
| Diplexer (85 MHz) | upstream 4-85 MHz; downstream 108-1,218 MHz |
| MoCA filter | All models have MoCA triplexer to filter out MoCA signals below the highest downstream frequency |
| RF Inputs/Outputs | RF(2) F connectors replaceable |
| Port 1 | Downstream 54/85/108/258MHz depending on diplexer |
| Port 2 | Upstream 0.5–204 MHz and TDR |
| Range | 0.5 to 1,218 MHz |
|---|---|
| Accuracy |
±10 ppm
typical @25°C
|
| Max Input Power | 60 dBmV total integrated power |
|---|---|
| Operation on Powered TAP | Operate with up to 90 VAC/DC on input port |
| Power Detection/Notification | Notify of AC/DC power presence on port 1 above 2 Volts |
| Return Loss | >9 dB |
| Auto Channel Plan Builder | Auto detection of channels (analog, digital, QAM, OFDM) |
| Ingress Spectrum Scan | 0.5–204 MHz, calibrated range 4-204 MHz |
|---|---|
| Sensitivity | −45 dBmV |
| RBW | 300 kHz |
| Min Detectable Level Upstream | −55 dBmV |
| Dynamic Range | 50 dB |
| Max Total Integrated Power | 55 dBmV, 4–10 MHz, 60 dBmV, 10 to 204 MHz |
| Accuracy |
±2 dB
typical at 25°C
|
| Sampling Rate | Hyper Spectrum FFT Gapless technology - no missed samples, spans 0.5 to 110 MHz, 110 to 160 MHz, and 160 to 204 MHz |
| Return Loss | >9.5 dB |
| Operation on Powered TAP | Operate with up to 90 V AC/DC on input port |
| Power Detection/Notification | Notify of AC/DC power presence on port 2 above 2 Volts |
| Standards |
NTSC, PAL, SECAM
Video and audio levels (dual)
|
|---|---|
| Min Detectable Signal |
−50 dBmV
Single channel
|
| Level Accuracy | ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C |
| RBW | 300 kHz |
| Calibrated Power Levels | -20 dBmV to +50 dBmV |
|---|---|
| Level Accuracy | ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C |
| Modulation(s) | 64, 128, and 256 QAM, OFDM |
| Annex A | 5.057 to 6.952 MSPS for 64, 128, and 256 QAM |
| Annex B | 5.057 MSPS for 64 QAM and 5.361 MSPS for 256 QAM |
| Annex C | 5.274 MSPS for 64 QAM, and 5.361 MSPS for 256 QAM |
| Regional demods | DVB-C |
| MER Specified range |
−5 to +20 dBmV: 21 to 40 dB, 64 QAM; 28 to 40 dB, 256 QAM; 16 to 44 dB, OFDM
MER range declines as input levels decrease. Expected MER range at MINLOCK level of –15 dBmV is >30 dB MER
|
| MER Max Displayable Range | 50 dB |
| MER Resolution | 0.1 dB |
| MER Accuracy |
±2 dB
typical at 25°C
|
| Minimum Lock Level | −15 dBmV |
| BER — Channel Check and DOCSIS Check mode | Down to 1E-9 (pre and post FEC) |
| BER — OneCheck Mode | Down to 1E-8 (pre and post FEC) Std. 1E-9 user selectable |
| Interleaver Depth | 128, 8 max |
| OFDM Channels | 24-192 MHz wide − up to 3 active OFDM channels |
|---|---|
| Level — max, min, average, standard deviation | Relative to a 6 MHz carrier per CableLabs® |
| MER — max, min, average, standard deviation, percentile | 16 to 44 dB |
| MER Channel Band Graph | Max, min, avg across entire OFDM carrier MER per subcarrier |
| ICFR | In-carrier frequency response (dB) |
| Spectrum/IUC | Spectrum display, including carrier and ingress under carrier |
| Profile Analysis | Profiles A, B, C, D, NCP, and PLC (more profiles as implemented); Lock status, code word errors (corrected and uncorrected) |
| Forward Sweep Telemetry Frequency |
Diplexer dependent 50-1,218 MHz
Input port: Port 1
|
|---|---|
| Forward Sweep Compatibility | SCU-1800 |
| Reverse Sweep Output Transmit Port | Port 1 or Port 2 (user selectable) |
| Port 1 Sweep Frequency Range | Diplexer dependent 5-42/5-65/5-85/5-204 MHz |
| Port 2 Sweep Frequency Range | 5-204 MHz |
| Reverse Sweep Compatibility | SCU-1800 or DAA/RPHY via XperTRAK |
| Broadband Optical Power Meter | Included |
|---|---|
| Optical Loss Mode (Set/clear Ref with Delta) | Included |
| Visual Fault Locator (1 mW) | Included |
| OneCheck WiFi7 / OneCheck Ethernet | Included |
| VIAVI SpeedCheck – 5 Gbps / 10 Gbps | Included |
| SWX Software Package | Included |
| Return Signal Generator w/Loopback | Included |
| Ingress Expert | Included |
| Optional capabilities | Optical Ethernet Testing over SFP+, OneCheck PON w/Emulation, Ookla Speedtest, VIAVI TrueSpeed, iPerf Speedtest, Smart Access Anywhere, HomeTDR, Home Leakage Test, Reverse Sweepless Sweep, QAM Video MPEG Verification, Field View w/RSG |
| PON Selective Optical Power Meter / TruePON | N/A |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- DOCSIS service activation and troubleshooting
- Multi-gig Ethernet service turn-up
- WiFi 7 service delivery validation
- FTTH and PON installation testing
- Optical power and loss measurement
- Fiber end-face inspection
- Upstream ingress troubleshooting
- Residential and small business service installation
Included
- ONX-CATV-D31-S-4285-1012 module (42/85 MHz D3.1)
- ONX 730 SWX Package
- Broadband Optical Power Meter
- VFL
- Optical Loss
- OneCheck Ethernet
- OneCheck WiFi
- 10G SpeedCheck
- Protective Fitted Case
- Cat6A jumper M-F and M-M
Options & Accessories
| Option | Description |
|---|---|
| ONXF-SW-SFP-ETH | Enable SFP+ port for Optical Ethernet testing over VIAVI supported SFP’s |
| ONXF-SW-OC-PON | OneCheck PON – PON testing via GPON/XGSPON SFP+ |
| ONXF-SW-OC-GPON-EMUL | GPON Emulation for live service testing on GPON network |
| ONXF-SW-OC-XGSPON-EMUL | GPON Emulation for live service testing on GPON network — Listed as printed in the datasheet |
| ONX-SMART-ACCESS | Smart Access Anywhere |
| ONXF-SW-OOKLA-SPD-5G-1Y | ONX Ookla Speedtest to 5 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G-3Y | ONX Ookla Speedtest to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G-5Y | ONX Ookla Speedtest to 5 Gbps 5 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G | ONX Ookla Speedtest to 5 Gbps |
| ONXF-SW-OOKLA-SPD-10G-1Y | ONX Ookla Speedtest to 10 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G-3Y | ONX Ookla Speedtest to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G-5Y | ONX Ookla Speedtest to 10 Gbps 5 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G | ONX Ookla Speedtest to 10 Gbps |
| ONXF-SW-TRUESPEED-5G-1Y | ONX TrueSpeed to 5 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-5G-3Y | ONX TrueSpeed to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-5G | ONX TrueSpeed to 5 Gbps permanent License |
| ONXF-SW-TRUESPEED-10G-1Y | ONX TrueSpeed to 10 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-10G-3Y | ONX TrueSpeed to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-10G | ONX TrueSpeed to 10 Gbps Permanent License |
| ONXF-SW-IPERF-5G-1Y | ONX iPerf test to 5 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-5G-3Y | ONX iPerf test to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-5G | ONX iPerf test to 5 Gbps Permanent License |
| ONXF-SW-IPERF-10G-1Y | ONX iPerf test to 10 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-10G-3Y | ONX iPerf test to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-10G | ONX iPerf test to 10 Gbps permanent License |
| ONX-CATV-SW-HL-LKG | Home Leakage Software Option |
| ONX-CATV-SW-HOMETDR | Home TDR Software Option |
| ONX-CATV-SW-REVSWPLSSWP | Reverse Sweepless Sweep Option for ONX 730’s |
| ONX-CATV-SW-QAM-VIDEO | QAM Video MPEG Verification Option |
| ONX-CATV-SW-RP-SNR-OCE | Return Path SNR in OneCheck Expert - OneExpert CATV |
| ONX-CATV-SW-FV-RSG | PathTrak Fieldview with Return Signal Generator for ONX 730s |
| ONX-CATV-FWD-SWEEP | Active Forward Sweep |
| ONX-CATV-REV-SWEEP | Active Reverse Sweep |
| NSC-SFP-GPON | GPON SFP for GPON emulation |
| NSC-SFP-XGSPON | XGSPON SFP+ for XGSPON emulation |
| NSC-SFP-850-1G-10G | Optical Ethernet SFP + 850 nm SR 1G and 10G |
| NSC-SFP-1310-1G-10G | Optical Ethernet SFP + 1310 nm LR 1G and 10G |
| NSC-SFP-1550-1G-10G | Optical Ethernet SFP + 1550 nm ER 1G and 10G |
| AC-CHARGER | Replacement AC charger (no power cord) |
| AC-CAR-CHARGER | Car Charger |
| CC-034601 | Large Carrying Case |
| 1019-00-1366 | Strand Hook |
| ONXF-HANDSTRAP | Handstrap for use on unit without a case |
| ONXF-HFC-BATT-96WHR | Replacement 96 W/Hr Battery |
| ONXF-DISPLAY-PROTECTOR-5P | Replacement screen protector (5 pack) |
| ONXF-ETH-ADAPT-M-F | Ethernet Cat6a M-F adapter 0.5 m |
| NSC-ETHERNET-CABLE | Ethernet Cat6a M-M Patch Cable |
| ONXF-CATV-D31-ADAPTR | Module adapter for existing D3.1 modules for ONX-720/730 |
| ONXF-HFC-CASE | Fitted protective case for ONX-720/730 with DOCSIS 3.1 |