OneExpert HFC ONXF-730-65-204-NTX DOCSIS 3.1 Field Meter, 65/204 MHz, NTX Package, No Optics
OneExpert HFC ONX-730 field meter with 65/204 MHz DOCSIS 3.1 module, NTX package and 10 Gbps Ethernet and WiFi 7 testing
- Test functions
- OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck
- DOCSIS module
- ONX-CATV-D31-S-6520-1212 module (65/204 MHz D3.1)
- Fiber optic testing
- No Optics
- Software package
- ONX 730 NTX Package
Overview
The VIAVI ONXF-730-65-204-NTX is a new-unit ordering configuration of the OneExpert HFC ONX-730. It is the No Optics package: it has no optical power meter or VFL, and it comes with the ONX-CATV-D31-S-6520-1212 DOCSIS 3.1 module (65/204 MHz upstream, 1.2 GHz/1.2 GHz downstream) and the ONX 730 NTX software package.
The OneExpert HFC platform tests DOCSIS, Ethernet and WiFi 7 throughput up to 10 Gbps. It uses VIAVI Test Process Automation (TPA) and one-button OneCheck workflows that give pass/fail results, with saved results geo-tagged. The aim is consistent installs, less technician training and fewer repeat visits.
DOCSIS and RF
The ONX-720/730 continues the ONX-620/630 line. It keeps their RF and DOCSIS testing functions and supports the existing RF modules. Measurements include downstream analog and digital channel analysis, OFDM signal and profile analysis, upstream ingress spectrum scanning, and forward and reverse sweep with the SCU-1800.
Platform
The unit is IP54 rated, weatherproof, drop-tested and modular. It has integrated GPS, StrataSync and mobile app support, and a field-replaceable 96 W/hr battery. Options add optical Ethernet over SFP+, OneCheck PON with GPON/XGS-PON emulation, Ookla Speedtest, TrueSpeed, iPerf and Smart Access Anywhere remote connectivity.
Key Features
- Unified OneCheck workflow automates pass/fail testing for DOCSIS, Ethernet and WiFi
- OneCheck Ethernet and OneCheck WiFi 7 included
- VIAVI SpeedCheck to 5 Gbps and 10 Gbps included
- ONX-CATV-D31-S-6520-1212 DOCSIS 3.1 module (65/204 MHz) included
- ONX 730 NTX software package included
- Return Signal Generator with Loopback included
- Ingress Expert included
- 10GBase-T RJ-45 Ethernet testing at 100M, 1G, 2.5G, 5G and 10G
- Optional optical Ethernet testing over SFP+
- Optional OneCheck PON with GPON/XGS-PON emulation using a VIAVI SFP
- USB fiber scope support with Auto Analysis
- Smart Access Anywhere remote coaching and training via PC or mobile connection
- IP54 rated, rugged, modular design with integrated GPS and StrataSync
- Field-replaceable 96 W/hr Li-Ion battery for multi-day use
Specifications
| Test functions | OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck |
|---|---|
| DOCSIS module |
ONX-CATV-D31-S-6520-1212 module (65/204 MHz D3.1)
65/204 MHz Upstream 1.2 GHz/1.2 GHz Downstream DOCSIS 3.1 Packages
|
| Fiber optic testing | No Optics |
| Software package | ONX 730 NTX Package |
| Standard | IEEE 802.3 100M, 1G, 2.5G, 5G, and 10G Ethernet |
|---|---|
| Test results | Ethernet Frames, IP Connectivity, Ping, Trace route, Web Connectivity, Speed Test up to 10 Gbps |
| 10GBase-T RJ-45 Electrical | 100M, 1G, 2.5G, 5G, 10G |
| SFP+ Optical Ethernet |
1G, 10G (SFP dependent)
Optional
|
| SFP+ Electrical Ethernet |
100M, 1G, 2.5G, 5G, 10G
Optional
|
| OneCheck WiFi (Connected Mode) | WiFi - 7 2x2 (802.11 a/b/g/n/ac/ax/be) 2.4, 5, 6 GHz bands |
|---|---|
| Test results | Signal strength (RSSI), Standard, Width, Max Router PHY Rate, IP/Web connectivity, Throughput Tests (SpeedCheck, Ookla Speedtest, iPerf) |
| VIAVI SpeedCheck |
5 Gbps, 10 Gbps
TCP throughput test
|
|---|---|
| Ookla Speedtest |
5 Gbps, 10 Gbps
Optional
|
| VIAVI TrueSpeed (RFC-6349) |
5 Gbps, 10 Gbps
Optional
|
| iPerf client |
5 Gbps, 10 Gbps
Optional
|
| Performance | Up to 10 Gbps for SpeedCheck, Ookla Speedtest, TrueSpeed |
| Test results | Delay, Upstream and Downstream Bit Rates |
| Bluetooth communication interface | Bluetooth v5.0, BLE 2.0 |
|---|---|
| Smart device support |
VIAVI Mobile Tech app, Android 8 or newer, iOS12 or newer
Recommendation
|
| USB host port(s) | USB-C, USB-A (USB 3.0) |
| USB optical fiber scope | P5000i, FiberChek Probe |
|---|---|
| Results for zone defects / scratches | Pass/Fail |
| Low Mag Field-of-View (FOV) | Horizontal 740 μm, Vertical 550 μm |
| High Mag Field-of-View (FOV) | Horizontal 370 μm, Vertical 275 μm |
| Particle size detection | <1 μm |
| Power source | USB port |
| Range | 0.5 to 1,218 MHz |
|---|---|
| Accuracy |
±10 ppm
typical @25°C
|
| Max input power | 60 dBmV total integrated power |
|---|---|
| Operation on powered TAP | Operate with up to 90 VAC/DC on input port |
| Power detection/notification | Notify of AC/DC power presence on port 1 above 2 Volts |
| Return loss | >9 dB |
| Auto channel plan builder | Auto detection of channels (analog, digital, QAM, OFDM) |
| Ingress spectrum scan | 0.5–204 MHz, calibrated range 4-204 MHz |
|---|---|
| Sensitivity | −45 dBmV |
| RBW | 300 kHz |
| Min detectable level upstream | −55 dBmV |
| Dynamic range | 50 dB |
| Max total integrated power | 55 dBmV, 4–10 MHz, 60 dBmV, 10 to 204 MHz |
| Accuracy |
±2 dB
typical at 25°C
|
| Sampling rate | Hyper Spectrum FFT Gapless technology - no missed samples, spans 0.5 to 110 MHz, 110 to 160 MHz, and 160 to 204 MHz |
| Return loss | >9.5 dB |
| Operation on powered TAP | Operate with up to 90 V AC/DC on input port |
| Power detection/notification | Notify of AC/DC power presence on port 2 above 2 Volts |
| Standards |
NTSC, PAL, SECAM
Video and audio levels (dual)
|
|---|---|
| Min detectable signal |
−50 dBmV
single channel
|
| Level accuracy | ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C |
| RBW | 300 kHz |
| Calibrated power levels | -20 dBmV to +50 dBmV |
|---|---|
| Level accuracy | ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C |
| Modulation(s) | 64, 128, and 256 QAM, OFDM |
| Annex A | 5.057 to 6.952 MSPS for 64, 128, and 256 QAM |
| Annex B | 5.057 MSPS for 64 QAM and 5.361 MSPS for 256 QAM |
| Annex C | 5.274 MSPS for 64 QAM, and 5.361 MSPS for 256 QAM |
| Regional demods | DVB-C |
| Measurements | Full span MER; Ingress under carrier — full span ingress noise trace; Group delay and in-channel response (ICR); Digital quality index (DQI) overtime; Errored/severely errored seconds; Level, measured symbol rate, carrier frequency, modulation, interleaver depth |
| OFDM channels | 24-192 MHz wide − up to 3 active OFDM channels |
|---|---|
| Level — max, min, average, standard deviation | Relative to a 6 MHz carrier per CableLabs® |
| MER — max, min, average, standard deviation, percentile | 16 to 44 dB |
| MER channel band graph | Max, min, avg across entire OFDM carrier MER per subcarrier |
| ICFR | In-carrier frequency response (dB) |
| Spectrum/IUC | Spectrum display, including carrier and ingress under carrier |
| Profile analysis | Profiles A, B, C, D, NCP, and PLC (more profiles as implemented); Lock status, code word errors (corrected and uncorrected) |
| MER specified range |
−5 to +20 dBmV 21 to 40 dB, 64 QAM; 28 to 40 dB, 256 QAM; 16 to 44 dB, OFDM
MER range declines as input levels decrease. Expected MER range at MINLOCK level of –15 dBmV is >30 dB MER.
|
|---|---|
| Max displayable range | 50 dB |
| Resolution | 0.1 dB |
| Accuracy |
±2 dB
typical at 25°C
|
| Minimum lock level | −15 dBmV |
| BER — Channel Check and DOCSIS Check mode | Down to 1E-9 (pre and post FEC) |
| BER — OneCheck Mode | Down to 1E-8 (pre and post FEC) Std. 1E-9 user selectable |
| Interleaver depth | 128, 8 max |
| RF (2) | F connectors replaceable |
|---|---|
| Port 1 | Downstream 54/85/108/258MHz depending on diplexer |
| Port 2 | Upstream 0.5–204 MHz and TDR |
| Diplexer 65 MHz (Port 1) |
upstream 4-65 MHz; downstream 85-1,218 MHz
Diplexer return path options may not be available on all units
|
| Diplexer 204 MHz (Port 1) |
upstream 4-204 MHz: downstream 258-1,218 MHz
Diplexer return path options may not be available on all units
|
| MoCA filter | All models have MoCA triplexer to filter out MoCA signals below the highest downstream frequency |
| RF immunity | 8.5 V/m (for CATV measurements) |
| Forward sweep telemetry frequency |
Diplexer dependent 50-1,218 MHz
Input port: Port 1
|
|---|---|
| Forward sweep compatibility | SCU-1800 |
| Reverse sweep output transmit port | Port 1 or Port 2 (user selectable) |
| Port 1 sweep frequency range | Diplexer dependent 5-42/5-65/5-85/5-204 MHz |
| Port 2 sweep frequency range | 5-204 MHz |
| Reverse sweep compatibility | SCU-1800 or DAA/RPHY via XperTRAK |
| Size |
5.0 x 11.1 x 4.25 in (W x L x H)
ONX-720 and ONX-730 with RF Module
|
|---|---|
| Weight |
3.15 kg (6.9 lb)
ONX-720 and ONX-730 with RF Module, without protective case
|
| Drop rating | 1 m (3.3 ft) onto concrete |
| Operating temperature range | Non-Charging: -10°C to 50°C; Battery Charging: 0°C to 40°C |
|---|---|
| Storage temperature range | -20°C to 60°C |
| Operating humidity range | 10% to 90% RH, non-condensing |
| For indoor/outdoor use | IP54 light rain (0.5 in/hr; 1.27 cm/hr) |
| Operating altitude | 4000 m max |
| Pollution | 2° |
| DC input power | 12 V@5 A |
|---|---|
| DC charge port | 2.5 mm barrel |
| Battery | 96 W/hr Li-Ion rechargeable battery, Field replaceable |
| Battery charge time | 4 Hrs (90%) 6-8 Hrs 100% (AC charger) |
| Battery life |
3-5 day typical usage for installation technicians
10 installs a day
|
| OneCheck WiFi7 | Standard |
|---|---|
| OneCheck Ethernet | Standard |
| VIAVI SpeedCheck – 5 Gbps / 10 Gbps | Standard |
| Return Signal Generator w/Loopback | Standard |
| Ingress Expert | Standard |
| Optical Ethernet Testing over SFP+ | Opt. |
| OneCheck PON w/Emulation – GPON/XGS PON using VIAVI SFP | Opt. |
| Ookla Speedtest, VIAVI TrueSpeed, iPerf Speedtest – 5 Gbps / 10 Gbps | Opt. |
| Smart Access Anywhere - Remote Connectivity | Opt. |
| HomeTDR, Home Leakage Test | Opt. |
| Reverse Sweepless Sweep, QAM Video MPEG Verification, Field View w/RSG | Opt. |
| Optical power meters, TruePON, Optical Loss Mode, Visual Fault Locator |
N/A
No Optics package
|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Residential DOCSIS service activation
- Small business service installation
- Multi-gig service turn-up
- WiFi 7 service delivery verification
- Ethernet throughput validation
- HFC ingress troubleshooting
- Upstream and downstream sweep
Included
- ONX-CATV-D31-S-6520-1212 module (65/204 MHz D3.1)
- ONX 730 NTX Package
- Protective Fitted Case
- Cat6A jumper M-F and M-M
Options & Accessories
| Option | Description |
|---|---|
| ONXF-SW-SFP-ETH | Enable SFP+ port for Optical Ethernet testing over VIAVI supported SFP’s |
| ONXF-SW-OC-PON | OneCheck PON – PON testing via GPON/XGSPON SFP+ |
| ONXF-SW-OC-GPON-EMUL | GPON Emulation for live service testing on GPON network |
| ONXF-SW-OC-XGSPON-EMUL | GPON Emulation for live service testing on GPON network — Description as printed in the datasheet |
| ONX-SMART-ACCESS | Smart Access Anywhere |
| ONXF-SW-OOKLA-SPD-5G-1Y | ONX Ookla Speedtest to 5 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G-3Y | ONX Ookla Speedtest to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G-5Y | ONX Ookla Speedtest to 5 Gbps 5 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G | ONX Ookla Speedtest to 5 Gbps |
| ONXF-SW-OOKLA-SPD-10G-1Y | ONX Ookla Speedtest to 10 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G-3Y | ONX Ookla Speedtest to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G-5Y | ONX Ookla Speedtest to 10 Gbps 5 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G | ONX Ookla Speedtest to 10 Gbps |
| ONXF-SW-TRUESPEED-5G-1Y | ONX TrueSpeed to 5 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-5G-3Y | ONX TrueSpeed to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-5G | ONX TrueSpeed to 5 Gbps permanent License |
| ONXF-SW-TRUESPEED-10G-1Y | ONX TrueSpeed to 10 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-10G-3Y | ONX TrueSpeed to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-10G | ONX TrueSpeed to 10 Gbps Permanent License |
| ONXF-SW-IPERF-5G-1Y | ONX iPerf test to 5 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-5G-3Y | ONX iPerf test to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-5G | ONX iPerf test to 5 Gbps Permanent License |
| ONXF-SW-IPERF-10G-1Y | ONX iPerf test to 10 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-10G-3Y | ONX iPerf test to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-10G | ONX iPerf test to 10 Gbps permanent License |
| ONX-CATV-SW-HL-LKG | Home Leakage Software Option |
| ONX-CATV-SW-HOMETDR | Home TDR Software Option |
| ONX-CATV-SW-REVSWPLSSWP | Reverse Sweepless Sweep Option for ONX 730’s |
| ONX-CATV-SW-QAM-VIDEO | QAM Video MPEG Verification Option |
| ONX-CATV-SW-RP-SNR-OCE | Return Path SNR in OneCheck Expert - OneExpert CATV |
| ONX-CATV-SW-FV-RSG | PathTrak Fieldview with Return Signal Generator for ONX 730s |
| ONX-CATV-FWD-SWEEP | Active Forward Sweep |
| ONX-CATV-REV-SWEEP | Active Reverse Sweep |
| NSC-SFP-GPON | GPON SFP for GPON emulation |
| NSC-SFP-XGSPON | XGSPON SFP+ for XGSPON emulation |
| NSC-SFP-850-1G-10G | Optical Ethernet SFP + 850 nm SR 1G and 10G |
| NSC-SFP-1310-1G-10G | Optical Ethernet SFP + 1310 nm LR 1G and 10G |
| NSC-SFP-1550-1G-10G | Optical Ethernet SFP + 1550 nm ER 1G and 10G |
| AC-CHARGER | Replacement AC charger (no power cord) |
| AC-CAR-CHARGER | Car Charger |
| CC-034601 | Large Carrying Case |
| 1019-00-1366 | Strand Hook |
| ONXF-HANDSTRAP | Handstrap for use on unit without a case |
| ONXF-HFC-BATT-96WHR | Replacement 96 W/Hr Battery |
| ONXF-DISPLAY-PROTECTOR-5P | Replacement screen protector (5 pack) |
| ONXF-ETH-ADAPT-M-F | Ethernet Cat6a M-F adapter 0.5 m |
| NSC-ETHERNET-CABLE | Ethernet Cat6a M-M Patch Cable |
| ONXF-CATV-D31-ADAPTR | Module adapter for existing D3.1 modules for ONX-720/730 |
| ONXF-HFC-CASE | Fitted protective case for ONX-720/730 with DOCSIS 3.1 |