OneExpert HFC ONXF-720-BB-42-204-TSX DOCSIS 3.1 and Fiber Field Tester with Broadband Power Meter, TSX Package
OneExpert HFC ONX-720 package with 42/204 MHz DOCSIS 3.1 module, broadband optical power meter, VFL and 10 Gbps Ethernet and WiFi 7 testing
- Standard
- IEEE 802.3 100M, 1G, 2.5G, 5G, and 10G Ethernet
- Test Results
- Ethernet Frames, IP Connectivity, Ping, Trace route, Web Connectivity, Speed Test up to 10 Gbps
- 10GBase-T RJ-45 Electrical
- 100M, 1G, 2.5G, 5G, 10G
- SFP+ Optical Ethernet
- 1G, 10G
Overview
The VIAVI ONXF-720-BB-42-204-TSX is a new-unit package of the OneExpert HFC ONX-720 handheld tester. It combines the ONX-720 mainframe with the ONX-CATV-D31-S-4220-1012 DOCSIS 3.1 module (42/204 MHz), a broadband optical power meter, a visual fault locator (VFL) and the ONX 720 TSX software package.
The OneExpert HFC platform validates DOCSIS, Ethernet, PON and WiFi 7 service throughput up to 10 Gbps in under a minute. VIAVI Test Process Automation (TPA) and the OneCheck workflows give technicians one-button pass/fail testing for Ethernet, WiFi and DOCSIS, with geotagged saved results.
Optical tools
The broadband power meter in this package covers 800 to 1650 nm through a 2.5 mm universal port, and the built-in 650 nm VFL helps locate breaks and faults. USB fiber scopes such as the P5000i and the FiberChek Probe connect to the unit for connector inspection with automatic pass/fail analysis.
DOCSIS and RF
The ONX-720/730 carries forward the RF and DOCSIS testing of the ONX-620/630 and supports existing RF modules. Its features include downstream and upstream analysis, OFDM signal metrics and profile analysis, and forward and reverse sweep with the SCU-1800.
Design
The unit is rated IP54, weatherproof and drop-tested. It has a modular design with an upgrade path to 25G/50G PON and DOCSIS 4.0. It also has integrated GPS, StrataSync and mobile app support, and a field-replaceable 96 W/hr battery for multi-day use.
Key Features
- Validates DOCSIS, Ethernet, PON and WiFi 7 throughput up to 10 Gbps in under a minute
- Unified OneCheck workflow automates pass/fail testing for DOCSIS, Ethernet and WiFi
- Broadband optical power meter with 8 calibrated wavelengths
- Visual fault locator (1 mW, 650 nm)
- 10GBase-T RJ-45 Ethernet testing at 100M, 1G, 2.5G, 5G and 10G
- WiFi 7 2x2 testing on 2.4, 5 and 6 GHz bands
- VIAVI SpeedCheck to 5 Gbps and 10 Gbps included
- USB fiber scope support with Auto Analysis and defect detection
- DOCSIS 3.1 module with 42/204 MHz diplexing and 1.0/1.2 GHz downstream
- Compatible with existing ONX DOCSIS/RF modules
- IP54 rated, weatherproof and drop-tested modular design
- Upgrade path for 25G/50G PON and DOCSIS 4.0
- Integrated GPS, StrataSync and VIAVI Mobile Tech app support
- Smart Access Anywhere remote coaching via PC or mobile connection (optional)
- Field-replaceable 96 W/hr Li-Ion battery for 3-5 days of typical use
Specifications
| Standard | IEEE 802.3 100M, 1G, 2.5G, 5G, and 10G Ethernet |
|---|---|
| Test Results | Ethernet Frames, IP Connectivity, Ping, Trace route, Web Connectivity, Speed Test up to 10 Gbps |
| 10GBase-T RJ-45 Electrical | 100M, 1G, 2.5G, 5G, 10G |
| SFP+ Optical Ethernet |
1G, 10G
SFP dependent; optional
|
| SFP+ Electrical Ethernet |
100M, 1G, 2.5G, 5G, 10G
Optional
|
| OneCheck WiFi (Connected Mode) | WiFi - 7 2x2 (802.11 a/b/g/n/ac/ax/be) 2.4, 5, 6 GHz bands |
|---|---|
| Test Results | Signal strength (RSSI), Standard, Width, Max Router PHY Rate, IP/Web connectivity, Throughput Tests (SpeedCheck, Ookla Speedtest, iPerf) |
| TCP Throughput Test |
VIAVI SpeedCheck: 5 Gbps, 10 Gbps; Ookla Speedtest: 5 Gbps, 10 Gbps; VIAVI TrueSpeed (RFC-6349): 5 Gbps, 10 Gbps
Ookla Speedtest and TrueSpeed are options; SpeedCheck 5/10 Gbps is standard
|
|---|---|
| Performance | Up to 10 Gbps for SpeedCheck, Ookla Speedtest, TrueSpeed, iPerf client: 5 Gbps, 10 Gbps |
| Test Results | Delay, Upstream and Downstream Bit Rates |
| Communication Interface | Bluetooth v5.0, BLE 2.0 |
|---|---|
| Smart Device Support |
VIAVI Mobile Tech app, Android 8 or newer, iOS12 or newer
Recommendation
|
| USB Optical Fiber Scope | P5000i, FiberChek Probe |
|---|---|
| Results for Zone Defects | Pass/Fail |
| Results for Zone Scratches | Pass/Fail |
| Low Mag Field-of-View (FOV) | Horizontal 740 μm, Vertical 550 μm |
| High Mag Field-of-View (FOV) | Horizontal 370 μm, Vertical 275 μm |
| Particle Size Detection | <1 μm |
| Power Source | USB port |
| Photo Diode | InGaAs |
|---|---|
| Spectral Range | Broadband (800…1650 nm) |
| Wavelength Setting | 850, 980, 1310, 1490, 1550, 1577, 1625, 1650 nm; Custom 800…1650 nm, step size 1 nm |
| Resolution | 0.01 dB, 0.001 μW |
| Measurement Range for Power Level | -65…+10 dBm |
| Max. Power Level | +16 dBm |
| Measurement Uncertainty |
±0.2 dB/±5% (intrinsic)
Under reference conditions: -11 dBm (CW), 1310 nm ±1 nm, 23 °C ±3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9 µm core, 8° APC), when used with SC/PC connectors
|
| Number of Calibrated Wavelengths | 8 (850, 980, 1310, 1490, 1550, 1577, 1625, 1650 nm) |
| Tone Detection |
270 Hz, 330 Hz, 1 kHz, 2 kHz
Future optional capability; received optical power level ≥ -50 dBm; when used with VIAVI Light Source
|
| Connection | UPP 2.5 mm |
| Fiber Compatibility | Single-mode, Multimode |
|---|---|
| Wavelength | 650 nm (visible) |
| Output Modes | Continuous and flashing |
| Connector Interface | Universal 2.5 mm (fixed) |
| Controls | On/Off Continuous/Flashing |
| Output Power | 1 mW |
| Laser Safety Rating | Class 2 |
| Range (maximum) |
7 km
VFL range depends on many factors, including fiber quality/loss
|
| Size |
5.0 x 11.1 x 4.25 in (W x L x H)
ONX-720 and ONX-730 with RF Module
|
|---|---|
| Weight |
3.15 kg (6.9 lb)
With RF Module, without protective case
|
| USB Host Port(s) | USB-C, USB-A (USB 3.0) |
| Operating Temperature Range | Non-Charging: -10°C to 50°C; Battery Charging: 0°C to 40°C |
|---|---|
| Storage Temperature Range | -20°C to 60°C |
| Operating Humidity Range | 10% to 90% RH, non-condensing |
| For Indoor/Outdoor Use | IP54 light rain (0.5 in/hr; 1.27 cm/hr) |
| Drop Rating | 1 m (3.3 ft) onto concrete |
| Operating Altitude | 4000 m max |
| Pollution | 2° |
| RF immunity |
8.5 V/m
For CATV measurements
|
| DC Input Power | 12 V@5 A |
|---|---|
| DC Charge Port | 2.5 mm barrel |
| Battery | 96 W/hr Li-Ion rechargeable battery, Field replaceable |
| Battery Charge Time | 4 Hrs (90%) 6-8 Hrs 100% (AC charger) |
| Battery Life | 3-5 day typical usage for installation technicians (10 installs a day) |
| DOCSIS Module |
ONX-CATV-D31-S-4220-1012 module (42/204 MHz D3.1)
42/204 MHz Upstream 1.0 GHz/1.2 GHz Downstream DOCSIS 3.1 Package
|
|---|---|
| Fiber Optic Testing | Broadband Optical Power Meter, VFL |
| Software Package | ONX 720 TSX Package |
| Standard Service Tests | OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck |
| Optional Service Tests |
Optical Ethernet Testing over SFP+, OneCheck PON w/Emulation – GPON/XGS PON using VIAVI SFP, Ookla Speedtest, VIAVI TrueSpeed, iPerf Speedtest, Smart Access Anywhere
Opt. in Package and Feature Matrix
|
| Optional CATV Features |
HomeTDR, Home Leakage Test, Return Signal Generator w/Loopback, Ingress Expert
Opt. in Package and Feature Matrix; Reverse Sweepless Sweep, QAM Video MPEG Verification and Field View w/RSG are N/A for this model
|
| Range | 0.5 to 1,218 MHz |
|---|---|
| Accuracy | ±10 ppm typical @25°C |
| Max Input Power | 60 dBmV total integrated power |
|---|---|
| Operation on Powered TAP | Operate with up to 90 VAC/DC on input port |
| Power Detection/Notification | Notify of AC/DC power presence on port 1 above 2 Volts |
| Return Loss | >9 dB |
| Auto Channel Plan Builder | Auto detection of channels (analog, digital, QAM, OFDM) |
| Ingress Spectrum Scan | 0.5–204 MHz, calibrated range 4-204 MHz |
|---|---|
| Sensitivity | −45 dBmV |
| RBW | 300 kHz |
| Min Detectable Level Upstream | −55 dBmV |
| Dynamic Range | 50 dB |
| Max Total Integrated Power | 55 dBmV, 4–10 MHz, 60 dBmV, 10 to 204 MHz |
| Accuracy | ±2 dB typical at 25°C |
| Sampling Rate | Hyper Spectrum FFT Gapless technology - no missed samples, spans 0.5 to 110 MHz, 110 to 160 MHz, and 160 to 204 MHz |
| Return Loss | >9.5 dB |
| Operation on Powered TAP | Operate with up to 90 V AC/DC on input port |
| Power Detection/Notification | Notify of AC/DC power presence on port 2 above 2 Volts |
| Standards |
NTSC, PAL, SECAM
Video and audio levels (dual)
|
|---|---|
| Min Detectable Signal | −50 dBmV (single channel) |
| Level Accuracy | ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C |
| RBW | 300 kHz |
| Calibrated Power Levels | -20 dBmV to +50 dBmV |
|---|---|
| Level Accuracy | ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C |
| Modulation(s) | 64, 128, and 256 QAM, OFDM |
| Annex A | 5.057 to 6.952 MSPS for 64, 128, and 256 QAM |
| Annex B | 5.057 MSPS for 64 QAM and 5.361 MSPS for 256 QAM |
| Annex C | 5.274 MSPS for 64 QAM, and 5.361 MSPS for 256 QAM |
| Regional demods | DVB-C |
| Measurements | Full span MER; Ingress under carrier — full span ingress noise trace; Group delay and in-channel response (ICR); Digital quality index (DQI) overtime; Errored/severely errored seconds; Level, measured symbol rate, carrier frequency, modulation, interleaver depth |
| OFDM Channels | 24-192 MHz wide − up to 3 active OFDM channels |
|---|---|
| Level — max, min, average, standard deviation | Relative to a 6 MHz carrier per CableLabs® |
| MER — max, min, average, standard deviation, percentile | 16 to 44 dB |
| MER Channel Band Graph | Max, min, avg across entire OFDM carrier MER per subcarrier |
| ICFR | In-carrier frequency response (dB) |
| Spectrum/IUC | Spectrum display, including carrier and ingress under carrier |
| Profile Analysis | Profiles A, B, C, D, NCP, and PLC (more profiles as implemented); Lock status, code word errors (corrected and uncorrected) |
| MER Specified range |
−5 to +20 dBmV 21 to 40 dB, 64 QAM; 28 to 40 dB, 256 QAM; 16 to 44 dB, OFDM
MER range declines as input levels decrease. Expected MER range at MINLOCK level of –15 dBmV is >30 dB MER.
|
|---|---|
| Max Displayable Range | 50 dB |
| Resolution | 0.1 dB |
| Accuracy | ±2 dB typical at 25°C |
| Minimum Lock Level | −15 dBmV |
| BER — Channel Check and DOCSIS Check mode | Down to 1E-9 (pre and post FEC) |
| BER — OneCheck Mode | Down to 1E-8 (pre and post FEC) Std. 1E-9 user selectable |
| Interleaver Depth | 128, 8 max |
| RF(2) | F connectors replaceable |
|---|---|
| Port 1 | Downstream 54/85/108/258MHz depending on diplexer |
| Port 2 | Upstream 0.5–204 MHz and TDR |
| Diplexer 42 MHz |
upstream 4-42 MHz; downstream 54–1,004 MHz
Diplexer return path options may not be available on all units
|
| Diplexer 204 MHz |
upstream 4-204 MHz: downstream 258-1,218 MHz
Diplexer return path options may not be available on all units
|
| MoCA filter | All models have MoCA triplexer to filter out MoCA signals below the highest downstream frequency |
| Forward Sweep Telemetry Frequency | Diplexer dependent 50-1,218 MHz |
|---|---|
| Forward Sweep Input Port | Port 1 |
| Forward Sweep Compatibility | SCU-1800 |
| Reverse Sweep Output Transmit Port | Port 1 or Port 2 (user selectable) |
| Port 1 Sweep Frequency Range | Diplexer dependent 5-42/5-65/5-85/5-204 MHz |
| Port 2 Sweep Frequency Range | 5-204 MHz |
| Reverse Sweep Compatibility | SCU-1800 or DAA/RPHY via XperTRAK |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Multi-gig residential service activation
- Small business service installation
- DOCSIS 3.1 HFC network troubleshooting
- Ethernet and WiFi 7 service validation
- Fiber optical power and continuity verification
- Upstream ingress troubleshooting
- Forward and reverse sweep with SCU-1800
Included
- ONX-CATV-D31-S-4220-1012 module (42/204 MHz D3.1)
- Broadband Optical Power Meter
- VFL
- OneCheck Ethernet
- OneCheck WiFi
- 10G SpeedCheck
- ONX 720 TSX Package
- Protective Fitted Case
- Cat6A jumper M-F and M-M
Options & Accessories
| Option | Description |
|---|---|
| ONXF-SW-OC-WIFI | OneCheck WiFi Software option |
| ONXF-SW-OC-ETHERNET | OneCheck Ethernet Software option |
| ONXF-SW-SFP-ETH | Enable SFP+ port for Optical Ethernet testing over VIAVI supported SFP's |
| ONXF-SW-OPTICAL-LOSS | Optical Loss test mode option to save reference and calculate loss |
| ONXF-SW-OC-PON | OneCheck PON – PON testing via GPON/XGSPON SFP+ |
| ONXF-SW-OC-GPON-EMUL | GPON Emulation for live service testing on GPON network |
| ONXF-SW-OC-XGSPON-EMUL | GPON Emulation for live service testing on GPON network |
| ONX-SMART-ACCESS | Smart Access Anywhere |
| ONXF-SW-OOKLA-SPD-5G-1Y | ONX Ookla Speedtest to 5 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G-3Y | ONX Ookla Speedtest to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G-5Y | ONX Ookla Speedtest to 5 Gbps 5 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G | ONX Ookla Speedtest to 5 Gbps |
| ONXF-SW-OOKLA-SPD-10G-1Y | ONX Ookla Speedtest to 10 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G-3Y | ONX Ookla Speedtest to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G-5Y | ONX Ookla Speedtest to 10 Gbps 5 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G | ONX Ookla Speedtest to 10 Gbps |
| ONXF-SW-TRUESPEED-5G-1Y | ONX TrueSpeed to 5 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-5G-3Y | ONX TrueSpeed to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-5G | ONX TrueSpeed to 5 Gbps permanent License |
| ONXF-SW-TRUESPEED-10G-1Y | ONX TrueSpeed to 10 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-10G-3Y | ONX TrueSpeed to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-10G | ONX TrueSpeed to 10 Gbps Permanent License |
| ONXF-SW-IPERF-5G-1Y | ONX iPerf test to 5 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-5G-3Y | ONX iPerf test to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-5G | ONX iPerf test to 5 Gbps Permanent License |
| ONXF-SW-IPERF-10G-1Y | ONX iPerf test to 10 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-10G-3Y | ONX iPerf test to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-10G | ONX iPerf test to 10 Gbps permanent License |
| ONX-CATV-SW-HL-LKG | Home Leakage Software Option |
| ONX-CATV-SW-HOMETDR | Home TDR Software Option |
| ONX-CATV-SW-RSG-LOOP | Return Signal Generator with Loopback Option |
| ONX-CATV-SW-INGRESS-EXP | Ingress Expert Option for ONX 720's |
| ONX-CATV-SW-RP-SNR-OCE | Return Path SNR in OneCheck Expert - OneExpert CATV |
| ONX-CATV-FWD-SWEEP | Active Forward Sweep |
| ONX-CATV-REV-SWEEP | Active Reverse Sweep |
| NSC-SFP-GPON | GPON SFP for GPON emulation |
| NSC-SFP-XGSPON | XGSPON SFP+ for XGSPON emulation |
| NSC-SFP-850-1G-10G | Optical Ethernet SFP + 850 nm SR 1G and 10G |
| NSC-SFP-1310-1G-10G | Optical Ethernet SFP + 1310 nm LR 1G and 10G |
| NSC-SFP-1550-1G-10G | Optical Ethernet SFP + 1550 nm ER 1G and 10G |
| AC-CHARGER | Replacement AC charger (no power cord) |
| AC-CAR-CHARGER | Car Charger |
| CC-034601 | Large Carrying Case |
| 1019-00-1366 | Strand Hook |
| ONXF-HANDSTRAP | Handstrap for use on unit without a case |
| ONXF-HFC-BATT-96WHR | Replacement 96 W/Hr Battery |
| ONXF-DISPLAY-PROTECTOR-5P | Replacement screen protector (5 pack) |
| ONXF-ETH-ADAPT-M-F | Ethernet Cat6a M-F adapter 0.5 m |
| NSC-ETHERNET-CABLE | Ethernet Cat6a M-M Patch Cable |
| ONXF-HFC-CASE | Fitted protective case for ONX-720/730 with DOCSIS 3.1 |