VIAVI ONT-800 rack-mount mainframe with application modules installed
VIAVI / Series · Bit Error Rate Test (BERT)

VIAVI ONT-800 Optical Network Tester Mainframe Platform

Configurable multi-protocol, multi-port test platform for R&D and system verification of optical transport ICs, modules and systems up to 800G.

Nominal voltage range
100 to 240 V
Nominal voltage range
200 to 240 V
Operating voltage range
85 to 265 V
Operating voltage range
170 to 265 V
View Models Datasheet

Overview

The VIAVI ONT-800 is a highly configurable, multi-protocol, multi-port test platform for R&D and system verification of optical transport ICs, modules and systems. It builds on its predecessor, the ONT-600, to deliver the bandwidth, power and cooling required for testing at 600G per lambda and beyond, and it accepts ONT-600 modules.

The ONT family offers several mainframe options and compatible application modules, ranging from single-slot point tools up to a full rack-mounted multi-slot, multi-port and multi-user solution for R&D, system verification testing (SVT) and manufacturing. The ONT-804D has four slots and a built-in 15-inch touchscreen for stand-alone lab use; the ONT-804, ONT-812 and ONT-812A provide 4 or 12 slots and are intended for scripted applications in SVT and manufacturing.

Software and automation

All application modules share the same GUI, automation and scripting. The mainframe runs Linux and can be operated locally via touchscreen or external display, keyboard and mouse, or remotely via Java Web Start or VNC. SCPI commands over LAN allow modules to be addressed independently and in parallel and shared among multiple users and mainframes. Scripting support covers Tcl/Tk, Python, C libraries and LabView.

Synchronization

A high-accuracy clock module synchronizes modules and test ports, with BNC, Bantam and Time of Day inputs for external synchronization. An ultra-high-accuracy GNSS and rubidium clock is available as a factory-fitted option.

Models in this series

Model Description
ONT-804D
VIAVI ONT-800 ONT-804D 4-Slot Optical Network Tester Mainframe with Touchscreen
Four-slot ONT-800 optical network tester mainframe with a built-in 15-inch touchscreen for stand-alone lab testing of 400G and 800G optics.
Details →
ONT-804
VIAVI ONT-804 Optical Network Tester 4-Slot Mainframe without Display
4-slot ONT-800 mainframe without display for scripted 800G optical transport test in system verification and manufacturing.
Details →
ONT-812
VIAVI ONT-812 12-Slot Rack-Mount Optical Network Tester Mainframe
12-slot, 19-inch rack-mount ONT-800 mainframe for multi-port, multi-user test of optical transport ICs, modules and systems up to 800G.
Details →
ONT-812A
VIAVI ONT-812A 12-Slot Rack Mount Optical Network Tester Mainframe, 110V AC Reduced Power Profile
12-slot rack-mount ONT-800 mainframe for 110V AC with a reduced power profile, for SVT and manufacturing test of optical transport systems.
Details →

Key Features

  • Designed to meet power and cooling requirements for 400G and 800G optical pluggables
  • Highest port density in the ONT family
  • Compatible with ONT-600 modules
  • One common architecture for software scripts across the ONT family
  • High-accuracy clock module to synchronize modules and test ports
  • ONT-804D with built-in touchscreen
  • Linux operating system
  • Hot-swappable modules
  • Rack-mountable
  • Remote control via SCPI commands over LAN
  • Scripting support for Tcl/Tk, Python, C libraries and LabView
  • Optional GNSS and rubidium synchronization

Specifications

Power Supply
Nominal voltage range
ONT-804, ONT-804D, ONT-812A
100 to 240 V
Nominal voltage range
ONT-812
200 to 240 V
Operating voltage range
ONT-804, ONT-804D, ONT-812A
85 to 265 V
Operating voltage range
ONT-812
170 to 265 V
Operating frequency 50/60 Hz
Max AC power
ONT-804, ONT-804D
1600 VA
Fully loaded mainframe
Max AC power
ONT-812
4400 VA (2 x 2200 VA)
Fully loaded mainframe
Max AC power
ONT-812A
3200 VA (2 x 1600 VA)
Fully loaded mainframe
Max DC power to application modules
ONT-804, ONT-804D
1200 W
Max DC power to application modules
ONT-812
3600 W
Max DC power to application modules
ONT-812A
2400 W
Physical
Number of application module slots
ONT-804, ONT-804D
4
Number of application module slots
ONT-812, ONT-812A
12
Dimensions (w x h x d)
ONT-804
400 x 200 x 495 mm
Including handle/bumpers, without modules
Dimensions (w x h x d)
ONT-804D
400 x 495 x 215 mm
Including handle/bumpers, without modules
Dimensions (w x h x d)
ONT-812, ONT-812A
483 x 666 x 460 mm
Including handle/bumpers, without modules
Weight
ONT-804
11.7 kg
Without modules
Weight
ONT-804D
14.2 kg
Without modules
Weight
ONT-812, ONT-812A
24 kg
Without modules
Display
Touch screen display
ONT-804D
Color TFT, 15 inches
ONT-804D only
Resolution
ONT-804D
1024 x 768 (XGA)
ONT-804D only
Local mini LCD display Graphic LCD display 128 x 32 pixels
Push buttons 2 push buttons
Display and control: IP address, mainframe reference clock settings and module connectivity check
Interfaces, Storage and Operation
Interfaces Ethernet (RJ45), 4 x USB, external keyboard, mouse, HDMI
Processor Intel, 16GB RAM
Hard drive for data/setup storage ≥ 64 GB
Operating system Linux
Remote operation Java Web Start or VNC
Remote control for test automation SCPI commands via LAN port
Scripting support Tcl/Tk, Python, C libraries, and LabView
Environmental
Ambient temperature, nominal range of use +5 to +35°C
Storage temperature −20 to +65°C
Transport temperature −20 to +65°C
Clock and Synchronization
Internal master clock module accuracy ±1.0 ppm
Exceeds T1.101 stratum 3/3E accuracy
Clock and time of day synchronization NTP, PTP, external GPS, 1PPS, Time of Day
Sync input connector, unbalanced 50 Ω, BNC jack
Clock source: DS1, E1; 1544, 2048 kHz, 1, 5, 10 MHz, 6312 kHz
Sync input connector, balanced 110 Ω, Bantam jack
Clock source: DS1, E1; 1544, 2048 kHz, 1 MHz
Clock output connector, unbalanced 50 Ω, BNC jack
Clock output connector, balanced 110 Ω, Bantam jack
Clock output frequencies E1, DS1, 2048 kHz, 1544 MHz
As printed in the datasheet
RJ45 clock in/out 1 pps and time of day, ITU and YD/T 2375-2011, cascade
GNSS Synchronization and Rubidium Oscillator (Optional)
Antenna input connector
3078/92.02
SMA 1.6/5.6, 50 Ω
RF input power
3078/92.02
max. +10 dBm
3.0 V / 50 mA max
Supported satellite systems
3078/92.02
GPS, Glonass, Beidou, Galileo
Time to first fix
3078/92.02
< 30 s
Warm up time Rb oscillator
3078/92.02
< 8 min
To reach frequency accuracy better than ± 1E-9 at ambient temperature 25°C
Overall synchronization time
3078/92.02
typical: < 30 min
Depends on satellite constellation and received signal quality
Time accuracy
3078/92.02
< ± 2 ns
Clear sky, good signal quality
Frequency accuracy without receiving satellites
3078/92.02
< ± 1E-10
Rb oscillator
Frequency accuracy during synchronization
3078/92.02
< ± 2E-8
Synchronized: long time stability of satellite system
Application Module Configuration
Number of active ports
N-PORT
4
Number of active ports
800G ETHERNET, 800G FLEX, 800G FLEX DCO
2 - 8
Number of active ports
800G FLEX XPM
1
Number of slots occupied in mainframe
N-PORT
1
Number of slots occupied in mainframe
800G ETHERNET, 800G FLEX, 800G FLEX DCO, 800G FLEX XPM
3
DC power consumption (max)
N-PORT
250 W
DC power consumption (max)
800G ETHERNET, 800G FLEX, 800G FLEX DCO, 800G FLEX XPM
700 W

Applications

  • R&D design testing
  • System development
  • Ethernet traffic load
  • Transponder hardware validation
  • FEC compliance validation
  • IC development and validation
  • System Verification Testing (SVT)
  • Manufacturing test

Options & Accessories

Option Description
3078/04 ONT-804D Mainframe with touchscreen display
3078/05 ONT-804 Mainframe without display — 19” / 21“ rack mount included
3078/07 ONT-812 Mainframe 12 slot rack mount version
3078/08 ONT-812A Mainframe 12 slot rack mount version for 110V AC with reduced power profile
3078/92.05 Rack Mount Kit 19” and 21” for ONT-804D
3078/92.02 ONT-800 Ultra High Accuracy GNSS Rb Clock — Hardware option, can only be fitted in the factory
K 810 Power cable, European IEC C19 Schuko 250 V 16 A
K 811 Power cable, UK C19 250 V 13 A
K 812 Power cable, Australia 250 V 15 A
K 814 Power cable, US NEMA 5-20 125 V 20 A
K 815 Power cable, US NEMA 6L-20 250 V 20 A

Documents & Resources