VIAVI CX200 SiteXpert handheld communications service monitor, front view
CX200

VIAVI CX200 SiteXpert Handheld Communications Service Monitor

Handheld communications service monitor for field and infrastructure testing of analog and digital land mobile radio systems up to 3 GHz.

Display size
8 in (20.3 cm)
Timebase accuracy
0.05 ppm
Timebase aging
±0.5 ppm/year
Warm-up time
30 minutes
Datasheet

Overview

The VIAVI CX200 SiteXpert is a handheld communications service monitor for field and infrastructure testing of land mobile radio (LMR) systems. It brings features from VIAVI's larger radio test sets into a field-portable package.

As the LMR market moves from analog to digital, the CX200 provides frequency, power and modulation analysis for both analog and digital systems. Supported technologies include AM/FM/PM/SSB, P25 Phase 1 and Phase 2 (including Linear Simulcast Modulation), TETRA, DMR, DMR Repeater and NXDN, with OneViewer post-analysis software.

Digital Radio Analysis

With the P25 and DMR options, the large display presents modulation analysis tools such as distribution plots, eye diagrams, constellation plots, trajectory plots (P25) and burst profile plots (DMR). Several plots can be viewed at the same time or a single plot expanded to full screen. The TETRA option supports testing of TETRA radios, mobile stations and base stations.

Automated Testing

The optional Auto-Test applications provide automated testing and alignment of land mobile radios with minimal user input.

Cable and Antenna Analysis

A standard 1-port vector network analyzer supports Distance to Fault, VSWR and Return Loss measurements. Calibrated measurements require the Short-Open-Load calibrator.

Key Features

  • Analog AM/FM/PM/SSB test
  • Tracking generator (standard)
  • Cable and Antenna Analyzer (1-Port) (standard)
  • Spectrum analyzer (standard)
  • 1-port vector network analyzer for Distance to Fault, VSWR and Return Loss
  • WiFi, Bluetooth and VNC (standard)
  • Smart Access Anywhere and StrataSync (standard)
  • Remote Command Interface (standard)
  • 1 GHz standard frequency range, 3 GHz optional
  • Optional P25 Phase 1 and P25 Phase 2 test, including Linear Simulcast Modulation
  • Optional DMR and DMR Repeater test
  • Optional TETRA test for mobile and base stations
  • Optional NXDN test
  • Optional Auto-Test applications for automated radio testing and alignment
  • Optional Bird power meter support
  • OneViewer post-analysis software
  • 8 in display

Specifications

General
Display size 8 in (20.3 cm)
Timebase accuracy 0.05 ppm
0°C to 50°C
Timebase aging ±0.5 ppm/year
Warm-up time 30 minutes
External reference 10 MHz
RF Generator
Frequency range 1 MHz to 1 GHz
optional, functional to 100 kHz
Frequency range
CX200-F3GHz
1 GHz to 3 GHz
Frequency resolution 1 Hz
RF Duplex Port output level range -135 dBm to -50 dBm
1 MHz to 3 GHz
RF Output Port output level range -95 dBm to 0 dBm
1 MHz to 3 GHz
Output level resolution 0.1 dB
Output level accuracy ±1.5 dB (1 MHz to 3 GHz) level >= -125 dBm; ±1.5 dB typical (level < -125 dBm)
Bandwidth 100 MHz
VSWR, RF Duplex Port ≤1.2
for frequency >1 MHz
VSWR, RF Output Port ≤1.6 typical
for frequency >1 MHz
Phase noise -100 dBc/Hz at 10 kHz offset at 1000 MHz
Frequency ≥1 MHz and Level ≤0 dBm
Harmonics ≤35 dBc (-50 dBc typical)
Frequency ≥1 MHz and Level ≤0 dBm
Non-harmonics ≤-50 dBc
Frequency ≥1 MHz and Level ≤0 dBm
Residual AM <0.5% RMS in 300 Hz to 3 kHz BW
Residual FM <15 Hz RMS in 300 Hz to 3 kHz BW; <6 Hz RMS, Typical <800 MHz
Analog Modulation
Modes AM, FM, PM, SSB
Modulation frequency range 20 Hz to 20 kHz
Distortion 3%
1000 Hz rate, >2 kHz Deviation, 300 Hz - 3 kHz BP filter
AM range 0% to 100%
AM accuracy (internal source) ≤±5% of settings
FM range 0 Hz to 100 kHz
FM accuracy (internal source) ≤±2.5% of setting
PM range 0 rad to 6.3 rad
PM accuracy <±2.5% of setting
with frequency response of ±0.5 dB 20 Hz to 10 kHz
SSB modulation frequency 30 Hz to 20 kHz
SSB carrier suppression >70 dB
SSB sideband suppression >60 dB
Internal modulation sources 3
Source waveforms Sine, Square, Triangle, Ramp, DTMF, DCS, CTCSS, Tone Remote, Tone Sequential, Two-Tone Sequential
CTCSS tone Tone 1 (67) to Tone 50 (254.1) Hz
RF Receiver
Frequency range 1 MHz to 1 GHz
optional, functional to 100 kHz
Frequency range
CX200-F3GHz
1 GHz to 3 GHz
RF Input Port maximum input level +21 dBm (125 mW) max preamp and frequency ≥1 MHz; +14 dBm (25 mW) max preamp and frequency <1 MHz
RF Duplex Port maximum input level +47 dBm (50 Watts) continuous, <35°C; +51 dBm (125 Watts) Cyclical
Cyclical: Max ON of 30 sec and Min OFF for 90 sec for power levels >50 Watts
Absolute max power 150 W
Alarm sounds (no auto shutdown)
VSWR, RF Duplex Port ≤1.2 (100 kHz to 1 GHz)
VSWR, RF Input Port ≤1.7 (1 MHz to 3 GHz)
with 10 dB input attenuation
2nd harmonic <-30 dBc
3rd harmonic <-45 dBc, <-60 dBc (typical)
Spurious response, input related ≤-42 dBc, -60 dBc (typical)
Spurious response, non-input related ≤-95 dBm (typical)
Phase noise -95 dBc/Hz at 10 kHz
Dynamic range >105 dB
TOI >+42 dBm
max gain
DANL <-163 dBm/Hz
at max gain
Analog sensitivity <-100 dBm
10 dB SINAD or better with 100 kHz Bandwidth filter
Bandwidth 100 MHz (wideband), 8 MHz (narrowband)
RF bandpass filters (IF filters) 5 kHz, 6.25 kHz, 8.33 kHz, 10 kHz, 12.5 kHz, 25 kHz, 30 kHz, 100 kHz, 300 kHz
Power Meter
Frequency range 1 MHz to 1 GHz (Standard)
Frequency range
CX200-F3GHz
1 GHz to 3 GHz
Measurement modes RMS, average RMS, minimum, maximum
Level, RF Duplex Port -67 dBm to +47 dBm
Level, RF Input Port -108 dBm to +10 dBm
Accuracy, RF Duplex Port ±0.4 dB (1 MHz to 1 GHz); ±0.6 dB elsewhere
Accuracy after normalizing at the measurement frequency
Accuracy, RF Input Port ±0.6 dB (1 MHz to 1 GHz), ±0.9 dB elsewhere
Accuracy after normalizing at the measurement frequency
RF Error Meter
Frequency range 1 MHz to 3 GHz
Resolution 1 Hz
Accuracy Same as timebase
Analog Demodulation Measurements
FM modes RMS, +Pk, -Pk, ±Pk/2
FM deviation 0 Hz to 75 kHz
FM accuracy ±1.0% for rate ≥1.5 kHz and ≤3 kHz; ±2.0% otherwise
Residual FM ≤3 Hz (300 Hz to 3 kHz) and frequency <1 GHz
AM measurement range 0% to 100%
AM accuracy ±1 % for depth ≥30% and ≤90% at 1 kHz rate; ±2% otherwise
AF frequency range 10 Hz to 20 kHz
PM range 0 radians to 6.3 radians
PM accuracy ±2.0%, ±1.0% (rate 1.5 kHz to 3 kHz)
SSB modes SSB-USB, SSB-LSB
Audio and Demodulation Meters
Distortion meter frequency range 50 Hz to 10 kHz
SINAD meter measurement range 0 dB to 60 dB
SINAD meter accuracy <±1 dB @12 dB SINAD
S/N meter accuracy ≤1 dB
AF tones analyzer modes DTMF, DCS, CTCSS, Two-Tone, Tone Sequential, Tone Remote
Audio level meter input impedance 100 K Ω, 600 Ω, 300 Ω
Audio analyzer frequency range DC to 100 kHz
Audio filters, lowpass 300 Hz, 3 kHz, 3.4 kHz, 5 kHz, 15 kHz, 20 kHz, 40 kHz, TIA 3 kHz, TIA 15 kHz
Audio filters, highpass 50 Hz, 300 Hz, TIA 50 Hz, TIA 300 Hz
Audio filters, other C-MSG, CCITT
FFT/Channel Analyzer
Span 2 kHz to 8 MHz
IF bandwidth 10 MHz
RBW 1 Hz to 50 kHz
Detector Normal, positive peak, negative peak, average (RMS)
FFT windows Flat top, Rectangular, Hamming, Hanning, Blackman-Harris
Spectrum Analyzer
Frequency range 1 MHz to 1 GHz (Standard)
Frequency range
CX200-F3GHz
1 GHz to 3 GHz
RBW range 25 Hz to 6 MHz
VBW range 5 Hz to 6 MHz
Sweep time range 0.4 ms to 1000 s
Spurious free dynamic range ≥80 dB
DANL <-162 dBm/Hz
max gain
Trigger Free run, External
Tracking Generator
Output ports RF Output Port, RF Duplex Port
Level range and accuracy Same as RF Generator
AF Generator
Frequency range 0 Hz to 100 kHz
Level range 0 Vpk to ±8 Vpk into 600 Ω
Level accuracy ±2%
level >=200 mV and frequency from 20 Hz to 20 kHz
THD+N <-75 dB
for frequency 1 kHz and level 1 Vrms
Max output current 100 mA
Oscilloscope
Sweep per div 1 µs to 100 ms/div
Vertical range 1 mV/div to 20 V/div
Bandwidth 20 kHz
Input range 20 mV to 30 Vrms (42.4 Vpk)
Coupling AC, DC
Digital Measurements
Modes P25, P25 Phase 2, TETRA, DMR, NXDN
Optional
P25 modulation fidelity accuracy
P25
<5% of reading (2.5% to 12%)
P25 symbol deviation accuracy
P25
±1%
TETRA modulation type
TETRA
π/4 DQPSK, 18 ksymbols/sec, TETRA filter (RRC with <0.35)
TETRA modulation accuracy
TETRA
<3% RMS, <6% peak
DMR FSK error range
DMR
0 to 20%
DMR symbol deviation range
DMR
1500 Hz to 2350 Hz
DMR protocol decode
DMR
Color Code, Call ID, Unit ID
Vector Network Analyzer
Frequency range 1 MHz to 3 GHz
Test port power (Port 1) 0 dBm
Dynamic range 90 dB
Parameters S11
Measurements Magnitude, VSWR, Distance to Fault, Cable Loss, Insertion Loss
Calibration method Short-Open-Load, Thru
Maximum distance 1000 ft (305 m)
Environmental/Physical
Weight 8.6 lbs (3.9 kg)
Temperature, operating 0°C to 50°C
Temperature, not operating -40°C to 71°C
Battery must not be subjected to temperatures below -20°C, nor above 60°C
Relative humidity 95% RH (non-condensing)
Altitude 4600 m
Vibration, shock, bench handling, transit drop MIL-PRF-28800F Class 3
Battery
Type Lithium Ion, 14.4 V, 6.8 Ah
Operating time 1.5 hours (typical), 3.75 hours (optional)
Battery charging limits 0°C to 45°C (32°F to 113°F) ≤85% RH
Compliance
EMC IEC 61000-3-2:2018; 6100-3-3:2013 +A1:2017; CISPR 11:2015 +A1:2016 +A2:2019
Safety EN IEC 61326-1:2021 Class A

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Land mobile radio field testing
  • Mission-critical radio infrastructure testing
  • Base station and repeater maintenance
  • Subscriber radio testing and alignment
  • Analog to digital LMR migration
  • Cable and antenna line sweeping

Options & Accessories

Option Description
CX200-F3GHz 3 GHz frequency range — Extends RF generator, receiver, power meter and spectrum analyzer coverage to 1 GHz to 3 GHz