Network Master MU909060A Gigabit Ethernet Modules for MT9090A Mainframe
Gigabit Ethernet test modules for the MT9090A Network Master, covering 10/100/1000 Mbps installation, maintenance and troubleshooting.
- Electrical interfaces
- 10/100/1000 Mbps RJ 45 (10BASE-T, 100BASE-TX, 1000BASE-T)
- Optical interfaces
- 100 or 1000 Mbps LC connector (100BASE-FX, 100BASE-LX, 1000BASE-SX, 1000BASE-LX or 1000BASE-ZX)
- Interface configuration
- Gigabit Ethernet Module with one SFP port and 1 electrical RJ-45 port. One optical module can be installed
- Interface configuration
- Gigabit Ethernet Module with 2 electrical RJ-45 ports
Overview
The MU909060A Gigabit Ethernet Modules fit the battery-powered Anritsu Network Master MT9090A mainframe. With a module installed, the instrument tests Gigabit Ethernet links during installation and maintenance and helps troubleshoot Ethernet communication lines. It provides bandwidth verification, connectivity testing and service availability verification.
The family has three models with different port configurations. The MU909060A1 has one SFP slot and one RJ-45 port, the MU909060A2 has two RJ-45 ports, and the MU909060A3 has two SFP slots. The two ports can be used at the same time, which shortens installation work across multiple ports and allows pass-through and bidirectional monitoring.
Field operation
The instrument is ready to measure in about 15 seconds and runs for up to 3 hours on a single charge, depending on configuration and setup. It has no fans or vents, and a protector that absorbs shock is supplied as standard. A 4.3-inch wide-screen color display shows results, and a Test Automator together with PASS/FAIL indicators guides users through test sequences. Setups can be stored and copied to other instruments over USB.
Test functions
The modules generate traffic for installation, commissioning and QoS verification, including VLAN-tagged traffic. They also provide BER testing, performance and QoS statistics, service disruption time measurement, and ping and traceroute tests. Optional software adds RFC 2544 testing (including end-to-end testing between two units), ITU-T Y.1564 multi-service testing, Multistream, Stacked VLAN, MPLS, Channel Stats and a Remote GUI that runs in a web browser.
Models in this series
| Model | Description | |
|---|---|---|
| MU909060A1 |
Network Master MU909060A1 Gigabit Ethernet Module with One SFP Slot and One RJ-45 Port
Gigabit Ethernet module for the MT9090A Network Master with one SFP slot and one RJ-45 port for 10/100/1000 Mbps field testing. |
Details → |
| MU909060A2 |
Network Master MU909060A2 Gigabit Ethernet Module with Two RJ-45 Ports
Gigabit Ethernet module with two electrical RJ-45 ports for the MT9090A Network Master, for 10/100/1000 Mbps field testing. |
Details → |
| MU909060A3 |
Network Master MU909060A3 Gigabit Ethernet Module with Two SFP Slots
Gigabit Ethernet module with two SFP slots for the MT9090A Network Master, for field installation and troubleshooting of Ethernet links. |
Details → |
Key Features
- RJ45 and SFP optical interface selectable for two ports
- Two ports work simultaneously, including pass through and in-line monitoring tests
- Ping test, traceroute test and electrical cable diagnostics
- Optional automated ITU-T Y.1564 testing of multiple simultaneous traffic streams
- Optional automated RFC 2544 testing, including end-to-end testing
- Stacked VLAN (Q-in-Q), MPLS, IPv4 and IPv6 supported
- Test Automator for running test sequences
- Channel Stats option identifies error streams, top talkers and network attacks
- Service disruption time measurement for VoIP and IPTV
- Optical power level check and electrical cable test for physical layer testing
- Pass/Fail identification and graphical result display
- PDF and CSV report generation
- 4.3-inch high resolution widescreen color display for indoor and outdoor use
- Rugged design with no fans or vents
- Modular platform
- Compact and lightweight design for field portability
Specifications
| Electrical interfaces | 10/100/1000 Mbps RJ 45 (10BASE-T, 100BASE-TX, 1000BASE-T) |
|---|---|
| Optical interfaces | 100 or 1000 Mbps LC connector (100BASE-FX, 100BASE-LX, 1000BASE-SX, 1000BASE-LX or 1000BASE-ZX) |
|
Interface configuration
MU909060A1 |
Gigabit Ethernet Module with one SFP port and 1 electrical RJ-45 port. One optical module can be installed |
|
Interface configuration
MU909060A2 |
Gigabit Ethernet Module with 2 electrical RJ-45 ports |
|
Interface configuration
MU909060A3 |
Gigabit Ethernet Module with two SFP ports. Two electrical or optical modules can be installed |
| Duplex modes | Full duplex. Electrical 10/100 Mbps also half duplex |
| Test configurations | Monitor/Generate, Pass through, Reflector |
|
1000BASE-SX 850 nm Multi Mode min. input sensitivity and wavelength
G0240A |
–17 dBm, 770 nm to 860 nm
Correct functioning can only be guaranteed with optical modules from Anritsu for the MU909060A |
|---|---|
|
1000BASE-SX 850 nm Multi Mode output power and wavelength
G0240A |
–9.5 to –1.5 dBm, 830 nm to 860 nm |
|
1000BASE-LX 1310 nm Single Mode min. input sensitivity and wavelength
G0241A |
–20 dBm, 1260 nm to 1580 nm |
|
1000BASE-LX 1310 nm Single Mode output power and wavelength
G0241A |
–10 to –3 dBm, 1285 nm to 1343 nm |
|
1000BASE-ZX 1550 nm Single Mode min. input sensitivity and wavelength
G0242A |
–22 dBm, 1260 nm to 1580 nm |
|
1000BASE-ZX 1550 nm Single Mode output power and wavelength
G0242A |
–3 to +5 dBm, 1480 nm to 1580 nm |
|
100BASE-FX 1310 nm Multi Mode min. input sensitivity and wavelength
G0243A |
–31 dBm, 1260 nm to 1570 nm |
|
100BASE-FX 1310 nm Multi Mode output power and wavelength
G0243A |
–20 to –14 dBm, 1270 nm to 1335 nm |
|
100BASE-LX 1310 nm Single Mode min. input sensitivity and wavelength
G0244A |
–28 dBm, 1260 nm to 1570 nm |
|
100BASE-LX 1310 nm Single Mode output power and wavelength
G0244A |
–15 to –8 dBm, 1261 nm to 1360 nm |
| Supported encapsulations | EtherType II (DIX v.2), IEEE 802.3 with 802.2 (LLC1), IEEE 802.3 with SNAP |
|---|---|
| Line rate | Variable line rate traffic generation, up to full line rate |
| Traffic shaping | Constant, Burst, Ramped |
| Frame size modes | Constant, Stepped or Random length |
| Adjustable frame size | 46 to 10,000 bytes |
| Addressing | Configurable MAC/IP source and destination addresses (supports IPv4 and IPv6), UDP/TCP address and DSCP/TOS byte |
| DHCP | Request IP source address from a DHCP server (On/Off) |
|
VLAN
Option 003 |
User defined up to 3 level VLAN ID and VLAN priority
Option |
|
MPLS
Option 004 |
User defined up to 3 level MPLS label
Option |
| Other generation functions | User defined traffic mix of unicast and broadcast frames; Generate and respond to pause frames; Answer incoming ARP request (On/Off); MAC/IP address swapping (reflector configuration) |
| Test result (current/cumulative) | Total frame, Total bit, Utilization, Throughput, Broadcast frame, Error frame, Frame loss, Frame loss rate |
|---|---|
| Graph | Tx utilization, Tx throughput, Rx utilization, Rx throughput, Error frame |
| Service Disruption Time | Min, Max, Average, Count, Total time, Total SDT (%), Last frame received (interval) timestamp |
|
Channel Stats
Option 006 |
Total frame, Total bit, Error, Frame size distribution of up to 63 filtered streams
Option |
| Status / Frame Statistics | Link status, Signal and Frames present (utilization), Errored frames, Rx/Tx frame count, Link time, Remote fault, Speed, Full/Half duplex, MDI/MDIX, Interface type, Link partner abilities (Pause capable and Asymmetric pause capable), Local clock (1000 Mbps), DHCP lease time, Optical level for optical interfaces |
| Event Log | The instrument logs major events during a test with a 1 sec. resolution time stamp. Logged events include: Link/No link and Test Start/Stop |
| Report Generation | Generation of test result reports as pdf-files. The report may be customized with a user logo and comments. |
|
Electrical Cable Test
MU909060A1, MU909060A2 |
Detection of MDI/MDIX mode, Link speed and status, Cable status and distance to fault (if any), Polarity. For 1000 Mbps also skew. Pin mapping: Tx/Rx for 10/100 Mbps, DA, DB, DC, DD for 1000 Mbps |
|---|---|
| BER Test pattern generation |
Unframed, Framed with IP header or Framed with IP and TCP/UDP header
Generation and detection of test patterns; count of errors in received test pattern; detection of sequence errors and loss of sequence synchronization |
| BER Test patterns supported | FOX, all 0, all 1, 0101, PING, PRBS 9, PRBS 11, PRBS 15, PRBS 20, PRBS 23, PRBS 29, PRBS 31, HF test pattern, CRPAT, JTPAT, SPAT |
| Ping Test |
Round Trip Time (RTT); Supports IPv4 and IPv6 addressing; Answer incoming Ping requests (On/Off)
For connectivity and configuration check |
| Traceroute Test | Setup: Number of Attempts, Max number of hops, Number of ping each host, Timeout. Result: Number of hop, Host IP address, Number of Received/Lost replies, Min/Max/Average time |
|
ITU-T Y.1564 test modes
Option 007 |
Single Ended test, Switch/Router test, End-to-End test
Option |
|
ITU-T Y.1564 Configuration Test
Option 007 |
Up to 32 services, Up to 6 steps with CBS, EBS. Test result: Pass/Fail, IR (Information Rate), FL (Frame Loss), FTD (Frame Transfer Delay), FDV (Frame Delay Variation)
Option |
|
ITU-T Y.1564 Service Performance Test
Option 007 |
Up to 32 services. Test result: Pass/Fail, IR (Information Rate), FL (Frame Loss), FTD (Frame Transfer Delay), FDV (Frame Delay Variation), AVAIL (Availability), UN-AVAIL (Unavailable seconds), SEQ ERR (Sequence Errors)
Option |
|
ITU-T Y.1564 test report and parameters
Option 007 |
Test report: Y.1564 Appendix II compliant (CSV or PDF). Parameters: Configurable with MT9090A's Test Automator or the standalone PC application (MX909060A)
Option |
|
RFC 2544 single ended and Switch/Router test modes
Option 001 |
Throughput and utilization, Frame loss, Latency, Packet jitter, Back-to-back frames (burstability)
Option |
|
RFC 2544 End-to-End network test mode
Option 001 |
Throughput and utilization, Frame loss, Back-to-back frames (burstability)
Two MU909060A in an in-band control setup; option |
|
RFC 2544 Router latency test mode
Option 001 |
IP ping based latency, IP ping based packet jitter
Option |
|
Multistream Test
Option 002 |
Up to 8 streams can be activated on the Ethernet line; available information per stream: Frame loss count/rate, Frames and bytes received, Frames and bytes transmitted
Option |
| HTTP/FTP Test | Test mode: HTTP, FTP. Setup: Target directory, Download file name, Authentication. Result: Received/Total file size, Min/Max/Average throughput |
| Reflector delay |
2.44 μs @1000 Mbps, 5.16 μs @100 Mbps, 31.93 μs @10 Mbps
Maximum internal delay when instrument is in reflector configuration |
| Internal memory |
40 MB
For storage of results, setups and screen shots |
|---|---|
| Stored configurations | The user can save a number of configuration files for later recall. The configuration files can be transferred to other instruments via the instruments USB port. |
| Test Automator | The user can create a macro to run several tests in sequence. The user can also load, save, import and export test macros |
| Service interface | Two USB 1.1 (One type A for USB memory stick, One type B for USB mass storage) |
| Display | 4.3-inch color LCD (480 × 272 pixels), with LED back light, transmissive |
| Language | English, Japanese, Chinese (Simplified, Traditional), Spanish, German, Korean, French, Italian, Portuguese |
| Battery |
Dedicated battery pack or 4 AA Ni-MH
Indicator for battery level in display when the unit is turned on |
|---|---|
| Operating time |
Up to 3 hours
Depending on configuration and test setup |
| Charging time |
4 hours while power off (typ.)
Temperature: +10° to +30°C |
| Power supply | AC adapter: 9 V(dc), 100 V(ac) to 240 V(ac), Frequency: 50 Hz/60 Hz |
|
Dimensions and mass (module)
MU909060A1, MU909060A2, MU909060A3 |
190 (W) × 96 (H) × 30 (D) mm, <600 g |
|---|---|
|
Dimensions and mass (mainframe)
MT9090A |
190 (W) × 96 (H) × 18 (D) mm, <200 g |
| Operational temperature range | 0° to +40°C, humidity ≤85%, No condensation |
|---|---|
| Storage temperature range | –25° to +60°C, humidity ≤80%, No condensation |
| Vibration | IEC 60 068-2-6 Fc and IEC 60 068-2-64 Fh |
| Ingress protection rating | IEC60529 IP51 |
| CE EMC | 2014/30/EU, EN61326-1, EN61000-3-2 |
|---|---|
| CE LVD | 2014/35/EU, EN61010-1 |
| CE RoHS | 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018 |
| UKCA EMC | S.I. 2016 No.1091, EN 61326-1, EN61000-3-2 |
| UKCA LVD | S.I. 2016 No.1101, EN 61010-1 |
| UKCA RoHS | S.I. 2012 No.3032, EN IEC 63000:2018 |
| Laser safety |
IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014 |
Applications
- Gigabit Ethernet installation and commissioning
- Ethernet maintenance and troubleshooting
- Carrier class Ethernet
- Mobile backhaul testing
- QoS verification
- VoIP and IPTV service disruption testing
- Outside plant field testing
Options & Accessories
| Option | Description |
|---|---|
| MU909060Ax-001 | RFC 2544 Test — Including End-To-End testing with master/slave control |
| MU909060Ax-002 | Multistream — Up to 8 streams simultaneous testing |
| MU909060Ax-003 | Stacked VLAN — Up to 3 levels tagged VLAN support |
| MU909060Ax-004 | MPLS — Up to 3 MPLS labels support |
| MU909060Ax-005 | Remote GUI — Controlling MT9090A via Web browser. Requires J1480A USB-Ethernet Converter to connect MT9090A to management Ethernet network |
| MU909060Ax-006 | Channel Stats — Analyzing error streams, top talkers, network attacks |
| MU909060Ax-007 | Y.1564 Test — New methodology to reduce testing time |
| MU909060A1-301 | RFC 2544 Test Retrofit (for MU909060A1) |
| MU909060A2-301 | RFC 2544 Test Retrofit (for MU909060A2) |
| MU909060A3-301 | RFC 2544 Test Retrofit (for MU909060A3) |
| MU909060A1-302 | Multistream Retrofit (for MU909060A1) |
| MU909060A2-302 | Multistream Retrofit (for MU909060A2) |
| MU909060A3-302 | Multistream Retrofit (for MU909060A3) |
| MU909060A1-303 | Stacked VLAN Retrofit (for MU909060A1) |
| MU909060A2-303 | Stacked VLAN Retrofit (for MU909060A2) |
| MU909060A3-303 | Stacked VLAN Retrofit (for MU909060A3) |
| MU909060A1-304 | MPLS Retrofit (for MU909060A1) |
| MU909060A2-304 | MPLS Retrofit (for MU909060A2) |
| MU909060A3-304 | MPLS Retrofit (for MU909060A3) |
| MU909060A1-305 | Remote GUI Retrofit (for MU909060A1) — Requires J1480A USB-Ethernet Converter (sold separately) |
| MU909060A2-305 | Remote GUI Retrofit (for MU909060A2) — Requires J1480A USB-Ethernet Converter (sold separately) |
| MU909060A3-305 | Remote GUI Retrofit (for MU909060A3) — Requires J1480A USB-Ethernet Converter (sold separately) |
| MU909060A1-306 | Channel Stats Retrofit (for MU909060A1) |
| MU909060A2-306 | Channel Stats Retrofit (for MU909060A2) |
| MU909060A3-306 | Channel Stats Retrofit (for MU909060A3) |
| MU909060A1-307 | Y.1564 Test Retrofit (for MU909060A1) |
| MU909060A2-307 | Y.1564 Test Retrofit (for MU909060A2) |
| MU909060A3-307 | Y.1564 Test Retrofit (for MU909060A3) |
| G0240A | 1000 Mbps SX SFP — 850 nm multimode, LC connector (optical) |
| G0241A | 1000 Mbps LX SFP — 1310 nm single mode, LC connector (optical) |
| G0242A | 1000 Mbps ZX SFP — 1550 nm single mode, LC connector (optical) |
| G0243A | 100 Mbps FX SFP — 1310 nm multimode, LC connector (optical) |
| G0244A | 100 Mbps LX SFP — 1310 nm single mode, LC connector (optical) |
| G0246A | 10/100/1000 Mbps RJ-45 SFP (electrical) |
| Z1580A | Protector & Soft Case — The protector (B0663A) and standard soft case (B0601B) form a set |
| B0600B | Hard Case — Accommodates two mainframes (with or without fitted protector) and accessories |
| B0602B | Deluxe Soft Case (for MT9090A) — Full Network Master operation without removal from the case; does not accommodate the mainframe if the protector is fitted |
| J1402A | Car Plug Cord |
| W3166AE | MU909060A1/A2/A3 Operation Manual (Hardcopy – English version) |
| J1480A | USB-Ethernet Converter — Requires MU909060Ax-y05 Remote GUI (sold separately) |
| MU909060A1-ES210 | 2 Years Extended Warranty Service (for MU909060A1) |
| MU909060A2-ES210 | 2 Years Extended Warranty Service (for MU909060A2) |
| MU909060A3-ES210 | 2 Years Extended Warranty Service (for MU909060A3) |
| MU909060A1-ES310 | 3 Years Extended Warranty Service (for MU909060A1) |
| MU909060A2-ES310 | 3 Years Extended Warranty Service (for MU909060A2) |
| MU909060A3-ES310 | 3 Years Extended Warranty Service (for MU909060A3) |