Network Master MU909060A2 Gigabit Ethernet Module with Two RJ-45 Ports
Gigabit Ethernet module with two electrical RJ-45 ports for the MT9090A Network Master, for 10/100/1000 Mbps field testing.
- Interface configuration
- MU909060A2: Gigabit Ethernet Module with 2 electrical RJ-45 ports.
- Electrical interfaces
- 10/100/1000 Mbps RJ 45 (10BASE-T, 100BASE-TX, 1000BASE-T)
- Duplex modes
- Full duplex. Electrical 10/100 Mbps also half duplex
- Test configurations
- Monitor/Generate, Pass through, Reflector
Overview
The Anritsu MU909060A2 is a Gigabit Ethernet module for the MT9090A Network Master mainframe. It has two electrical RJ-45 ports. Fitted to the mainframe, it makes a compact, battery-powered tester for installing, commissioning and troubleshooting Ethernet communication lines at 10/100/1000 Mbps.
The instrument checks bandwidth, connectivity and service availability. It has a 4.3-inch wide-screen color display and a graphical user interface for setup and result viewing. It is ready to measure about 15 seconds after start-up. Depending on configuration, it runs for up to 3 hours on one battery charge. The design has no fans or vents, which keeps dust and moisture out.
Network activation
For installation and QoS verification, the module generates traffic, including VLAN-tagged traffic, and provides BER testing, performance statistics and QoS statistics. Optional RFC 2544 and ITU-T Y.1564 test suites automate service activation testing. In end-to-end mode, two units work together in an in-band control setup and both units' results are shown on the master instrument. A Test Automator runs a sequence of tests, and setups can be copied to other instruments over USB.
Maintenance and troubleshooting
Both ports can be used at the same time, which supports pass-through monitoring and bidirectional monitoring. On the MU909060A2, an electrical cable test detects cable status, distance to fault, pin mapping and polarity. Optional Channel Stats can monitor up to 63 filtered streams. With the Remote GUI option, the instrument can be operated from a web browser. Results can be exported as PDF or CSV reports.
Key Features
- Two electrical RJ-45 ports usable simultaneously
- Ping test, traceroute test and electrical cable diagnostics
- Pass-through test and in-line monitoring using two ports
- Option for automated ITU-T Y.1564 testing of multiple simultaneous traffic streams
- Option for automated RFC 2544 testing including end-to-end master/slave control
- Test Automator for running sequences of tests
- Channel Stats option identifies error streams, top talkers and network attacks
- Service disruption time measurement for VoIP and IPTV
- Stacked VLAN (Q-in-Q), MPLS, IPv4 and IPv6 supported
- Pass/Fail indication and graphical result display
- PDF and CSV report generation
- 4.3-inch high-resolution wide-screen color display readable indoors and outdoors
- Ready for measurement in about 15 seconds
- Up to 3 hours of testing on a single charge
- Fanless, ventless rugged design
- Modular platform based on the MT9090A mainframe
Specifications
|
Interface configuration
MU909060A2
|
MU909060A2: Gigabit Ethernet Module with 2 electrical RJ-45 ports. |
|---|---|
| Electrical interfaces | 10/100/1000 Mbps RJ 45 (10BASE-T, 100BASE-TX, 1000BASE-T) |
| Duplex modes | Full duplex. Electrical 10/100 Mbps also half duplex |
| Test configurations | Monitor/Generate, Pass through, Reflector |
| Supported encapsulations | EtherType II (DIX v.2), IEEE 802.3 with 802.2 (LLC1), IEEE 802.3 with SNAP |
| Line rate | Variable line rate traffic generation, up to full line rate |
|---|---|
| Traffic shaping | Constant, Burst, Ramped |
| Frame sizes | Constant, Stepped or Random length; adjustable frame size from 46 to 10,000 bytes |
| Addressing | Configurable MAC/IP source and destination addresses (supports IPv4 and IPv6), UDP/TCP address and DSCP/TOS byte; request IP source address from a DHCP server (On/Off) |
| VLAN |
User defined up to 3 level VLAN ID and VLAN priority
Option
|
| MPLS |
User defined up to 3 level MPLS label
Option
|
| Other generation functions | User defined traffic mix of unicast and broadcast frames; generate and respond to pause frames; answer incoming ARP request (On/Off); MAC/IP address swapping (reflector configuration) |
| Test result (current/cumulative) | Total frame, Total bit, Utilization, Throughput, Broadcast frame, Error frame, Frame loss, Frame loss rate |
| Graph | Tx utilization, Tx throughput, Rx utilization, Rx throughput, Error frame |
| Service Disruption Time | Min, Max, Average, Count, Total time, Total SDT (%), Last frame received (interval) timestamp |
| Channel Stats |
Total frame, Total bit, Error, Frame size distribution of up to 63 filtered streams
Option
|
| Status / Frame Statistics | Link status, Signal and Frames present (utilization), Errored frames, Rx/Tx frame count, Link time, Remote fault, Speed, Full/Half duplex, MDI/MDIX, Interface type, Link partner abilities (Pause capable and Asymmetric pause capable), Local clock (1000 Mbps), DHCP lease time |
|---|---|
| Event Log | The instrument logs major events during a test with a 1 sec. resolution time stamp. Logged events include: Link/No link and Test Start/Stop |
| Report Generation | Generation of test result reports as pdf-files. The report may be customized with a user logo and comments. |
|
Electrical Cable Test
MU909060A2
|
Detection of MDI/MDIX mode, Link speed and status, Cable status and distance to fault (if any), Polarity. For 1000 Mbps also skew; Pin mapping: Tx/Rx for 10/100 Mbps, DA, DB, DC, DD for 1000 Mbps
MU909060A1/A2
|
|---|---|
| BER Test pattern generation |
Unframed, Framed with IP header or Framed with IP and TCP/UDP header
Generation and detection of test patterns; count of errors in received test pattern; detection of sequence errors and loss of sequence synchronization
|
| BER Test patterns supported | FOX, all 0, all 1, 0101, PING, PRBS 9, PRBS 11, PRBS 15, PRBS 20, PRBS 23, PRBS 29, PRBS 31, HF test pattern, CRPAT, JTPAT, SPAT |
| Ping Test |
Round Trip Time (RTT); Supports IPv4 and IPv6 addressing; Answer incoming Ping requests (On/Off)
For connectivity and configuration check
|
| Traceroute Test | Setup: Number of Attempts, Max number of hops, Number of ping each host, Timeout. Result: Number of hop, Host IP address, Number of Received/Lost replies, Min/Max/Average time |
| ITU-T Y.1564 Test test modes |
Single Ended test, Switch/Router test, End-to-End test
Option
|
| ITU-T Y.1564 Configuration Test |
Up to 32 services, Up to 6 steps with CBS, EBS. Test result: Pass/Fail, IR (Information Rate), FL (Frame Loss), FTD (Frame Transfer Delay), FDV (Frame Delay Variation)
Option
|
| ITU-T Y.1564 Dedicated Service Performance Test |
Up to 32 services. Test result: Pass/Fail, IR (Information Rate), FL (Frame Loss), FTD (Frame Transfer Delay), FDV (Frame Delay Variation), AVAIL (Availability), UN-AVAIL (Unavailable seconds), SEQ ERR (Sequence Errors)
Option
|
| ITU-T Y.1564 test report |
Y.1564 Appendix II compliant (CSV or PDF)
Parameters configurable with MT9090A's Test Automator or the standalone PC application (MX909060A)
|
| RFC 2544 single ended and Switch/Router test modes |
Throughput and utilization, Frame loss, Latency, Packet jitter, Back-to-back frames (burstability)
Option
|
| RFC 2544 End-to-End network test mode |
Throughput and utilization, Frame loss, Back-to-back frames (burstability)
Option; two MU909060A in an in-band control setup
|
| RFC 2544 Router latency test mode |
IP ping based latency, IP ping based packet jitter
Option
|
| Multistream Test |
Up to 8 streams can be activated on the Ethernet line; available information per stream: Frame loss count/rate, Frames and bytes received, Frames and bytes transmitted
Option
|
| HTTP/FTP Test | Test mode: HTTP, FTP. Setup: Target directory, Download file name, Authentication. Result: Received/Total file size, Min/Max/Average throughput |
| Reflector Delay |
2.44 μs @1000 Mbps, 5.16 μs @100 Mbps, 31.93 μs @10 Mbps
Maximum internal delay when instrument is in reflector configuration
|
| Internal Memory |
40 MB
For storage of results, setups and screen shots
|
|---|---|
| Stored Configurations | The user can save a number of configuration files for later recall. The configuration files can be transferred to other instruments via the instruments USB port. |
| Test Automator | The user can create a macro to run several tests in sequence. The user can also load, save, import and export test macros |
| Service Interface | Two USB 1.1 (One type A for USB memory stick, One type B for USB mass storage) |
| Display | 4.3-inch color LCD (480 × 272 pixels), with LED back light, transmissive |
| Language | English, Japanese, Chinese (Simplified, Traditional), Spanish, German, Korean, French, Italian, Portuguese |
| Battery | Dedicated battery pack or 4 AA Ni-MH |
|---|---|
| Operating time |
Up to 3 hours
Depending on configuration and test setup
|
| Charging time |
4 hours while power off (typ.)
Temperature: +10° to +30°C
|
| Power Supply | AC adapter: 9 V(dc), 100 V(ac) to 240 V(ac), Frequency: 50 Hz/60 Hz |
|
Dimensions and Mass (module)
MU909060A2
|
190 (W) × 96 (H) × 30 (D) mm, <600 g
MU909060A1/A2/A3; the web page and brochure p.5 describe the tester as an 800 g package
|
|---|---|
|
Dimensions and Mass (MT9090A mainframe)
MT9090A
|
190 (W) × 96 (H) × 18 (D) mm, <200 g |
| Operational Temperature Range | 0° to +40°C, humidity ≤85%, No condensation |
|---|---|
| Storage Temperature Range | –25° to +60°C, humidity ≤80%, No condensation |
| Vibration | IEC 60 068-2-6 Fc and IEC 60 068-2-64 Fh |
| Ingress Protection Rating | IEC60529 IP51 |
| CE EMC | 2014/30/EU, EN61326-1, EN61000-3-2 |
|---|---|
| CE LVD | 2014/35/EU, EN61010-1 |
| CE RoHS | 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018 |
| UKCA EMC | S.I. 2016 No.1091, EN 61326-1, EN61000-3-2 |
| UKCA LVD | S.I. 2016 No.1101, EN 61010-1 |
| UKCA RoHS | S.I. 2012 No.3032, EN IEC 63000:2018 |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Gigabit Ethernet installation and commissioning
- Ethernet maintenance and troubleshooting
- Carrier Ethernet service activation
- Mobile backhaul testing
- QoS verification
- Multiple-port network deployment
Included
- W3173AE Gigabit Ethernet Tester Quick Start Guide
- Z1234A Network Master Gigabit Ethernet Tester CD
Options & Accessories
| Option | Description |
|---|---|
| MU909060A2-001 | RFC 2544 Test (for MU909060A2) — Including End-To-End testing with master/slave control |
| MU909060A2-002 | Multistream (for MU909060A2) — Up to 8 streams simultaneous testing |
| MU909060A2-003 | Stacked VLAN (for MU909060A2) — Up to 3 levels tagged VLAN support |
| MU909060A2-004 | MPLS (for MU909060A2) — Up to 3 MPLS labels support |
| MU909060A2-005 | Remote GUI (for MU909060A2) — Controlling MT9090A via Web browser. Requires J1480A USB-Ethernet Converter (sold separately) |
| MU909060A2-006 | Channel Stats (for MU909060A2) — Analyzing error streams, top talkers, network attacks |
| MU909060A2-007 | Y.1564 Test (for MU909060A2) — New methodology to reduce testing time |
| MU909060A2-301 | RFC 2544 Test Retrofit (for MU909060A2) — Field installable by the customer |
| MU909060A2-302 | Multistream Retrofit (for MU909060A2) — Field installable by the customer |
| MU909060A2-303 | Stacked VLAN Retrofit (for MU909060A2) — Field installable by the customer |
| MU909060A2-304 | MPLS Retrofit (for MU909060A2) — Field installable by the customer |
| MU909060A2-305 | Remote GUI Retrofit (for MU909060A2) — Requires J1480A USB-Ethernet Converter (sold separately) |
| MU909060A2-306 | Channel Stats Retrofit (for MU909060A2) — Field installable by the customer |
| MU909060A2-307 | Y.1564 Test Retrofit (for MU909060A2) — Field installable by the customer |
| MU909060A2-ES210 | 2 Years Extended Warranty Service (for MU909060A2) |
| MU909060A2-ES310 | 3 Years Extended Warranty Service (for MU909060A2) |
| MT9090A | Mainframe (with color LCD) — Network Master mainframe required to operate the module |
| Z1580A | Protector & Soft Case — The protector (B0663A) and standard soft case (B0601B) form a set |
| B0600B | Hard Case — Accommodates two mainframes (with or without fitted protector) and accessories |
| B0602B | Deluxe Soft Case (for MT9090A) — Full Network Master operation without removal from the case; does not accommodate the mainframe if the protector is fitted |
| J1402A | Car Plug Cord |
| W3166AE | MU909060A1/A2/A3 Operation Manual (Hardcopy – English version) |
| J1480A | USB-Ethernet Converter — Requires MU909060Ax-y05 Remote GUI (sold separately) |