VIAVI 4100 Series OTDR module, E4126B variant, front view
E4126B

4100 Series B OTDR Module E4126B 1310/1550 nm Dual-Wavelength Singlemode OTDR Module for T-BERD/MTS and OneAdvisor Platforms

Dual-wavelength 1310/1550 nm 4100 B OTDR module with 42/40 dB dynamic range for T-BERD/MTS-2000, -4000 V2, -5800, OneAdvisor 800 and FTH-9000 platforms.

Module variant
4100 B
Laser safety class
Class 1 - IEC 60825-1:2014
Sampling points
Up to 256,000
Sampling resolution
4 cm min
Datasheet

Overview

The VIAVI E4126B is the 4100 Series B OTDR module with 1310 nm and 1550 nm test wavelengths, ordered as E4126B-PC or E4126B-APC depending on the test port adapter. It is a field-swappable module for the T-BERD/MTS-2000, T-BERD/MTS-4000 V2, T-BERD/MTS-5800, OneAdvisor 800 and FTH-9000 platforms, and is used to install, turn up and troubleshoot optical networks including data center interconnection, metro, long-haul, FTTx/access and point-to-multipoint passive optical networks.

The 4100 B variant offers 42 dB RMS dynamic range at 1310 nm and 40 dB at 1550 nm, up to 256,000 acquisition points, a 0.65 m event dead zone and a 3 m attenuation dead zone. Distance display range extends from 0.1 up to 260 km. Live wavelength isolation of more than 45 dB and permanent live traffic detection protect transmission equipment and measurement quality when testing in the presence of live signals.

Light source and power meter

An integrated light source is available on the OTDR port, delivering -3.5 dBm in CW mode with 270 Hz, 330 Hz, 1 kHz and 2 kHz tone modulation and an auto-wavelength mode for use with VIAVI power meters. An in-line broadband power meter (hardware option E41OTDRPM) adds power measurement on the same port.

Software and workflow

Results are presented through SmartLink Mapper (SLM), which identifies passive elements in the trace and shows them as icons on a link map with pass/fail information, with direct toggling between SmartLink, Trace and Table views. SmartTEST guides the operator through setup, test, review and reporting steps. Optional mainframe software adds TrueBIDIR on-board bidirectional OTDR analysis, Loopback two-fiber bidirectional testing, Cable-SLM project management for high fiber count cables and FTTH-SLM applications for PON architectures. Test Process Automation (TPA) connects the module to cloud-based job assignment and results submission.

Module portability lets the same fiber test capability move between VIAVI platforms, so existing certification tools can be combined with coax and RF, active xWDM, MPO/ribbon cable or network layer tests on the mainframe.

Key Features

  • Dual-wavelength 1310/1550 nm singlemode OTDR module
  • 42 dB RMS dynamic range at 1310 nm and 40 dB at 1550 nm
  • Up to 256,000 acquisition points
  • Event dead zone 0.65 m and attenuation dead zone 3 m
  • Distance display range 0.1 up to 260 km
  • Pulse widths from 5 ns to 20 µs
  • Live wavelength isolation >45 dB with instantaneous automatic traffic detection
  • Integrated light source and optional in-line power meter on the OTDR port
  • SmartLink Mapper (SLM) icon-based results view with pass/fail analysis
  • Easy toggle between SmartLink, Trace and Table views with direct event correlation
  • SmartTEST assistant with four-step guided setup, testing, review and reporting
  • OTDR test port health check and embedded launch cable measurement
  • Touch gesture user interface with pinch zoom, swipe and long press control
  • Available in FiberComplete PRO version for automated bidirectional OTDR, IL and ORL measurements
  • Instant bidirectional OTDR event loss analysis TrueBIDIR (patented) with data link via the fiber under test
  • Automated batch testing with MPO-based multifiber switches, up to 192 ports
  • Cable-SLM software option for high fiber count cable projects
  • Consolidated reporting for all wavelengths tested
  • Cloud-based job assignment and instant results submission with Job Manager
  • Module portability between T-BERD/MTS, OneAdvisor 800 and FTH-9000 platforms
  • Delivered with SC/PC or SC/APC test port adapter

Specifications

OTDR
Module variant
E4126B
4100 B
Laser safety class Class 1 - IEC 60825-1:2014
Sampling points Up to 256,000
Sampling resolution 4 cm min
Distance display range
4100 B
0.1 up to 260 Km
Distance accuracy ± (0.5 m + sampling resolution + 0.001% x distance)
Excluding group index uncertainties
Attenuation linearity ± 0.03 dB/dB
Reflectance accuracy ± 2 dB
Central wavelength (1310 nm)
4100 B
1310 ± 20 nm
Laser in CW and 25°C
Central wavelength (1550 nm)
4100 B
1550 ± 20 nm
Laser in CW and 25°C
RMS dynamic range at 1310 nm
4100 B
42 dB
One-way difference between the extrapolated backscattering level at the start of the fiber and the RMS noise level, after 3 minutes averaging
RMS dynamic range at 1550 nm
4100 B
40 dB
One-way difference between the extrapolated backscattering level at the start of the fiber and the RMS noise level, after 3 minutes averaging
Pulse widths
4100 B
5 ns to 20 µs
Event dead zone
4100 B
0.65 m
Measured at ±1.5 dB down from the peak of an unsaturated reflective event, using 5 ns pulse width at 1310 nm
Attenuation dead zone
4100 B
3 m
Measured at ±0.5 dB down from the linear regression using a FC/UPC-type reflectance, using 5 ns pulsewidth at 1310 nm
Attenuation dead zone (PON splitter)
4100 B
45 m
4100B measured on a 16 dB loss (typical 1x32 split ratio) non-reflective splitter at 1310 nm, using 200 ns pulsewidth
Live wavelength isolation >45 dB; 1260 to 1620 nm
Light Source
Wavelengths 1310/1550/1625 nm
Series-level specification; the E4126B is a 1310/1550 nm module
Output power level -3.5 dBm in CW mode
Modulation frequency (tone generation) 270 Hz, 330 Hz, 1 KHz, 2 KHz
Stability (8 hours) < ± 0.1 dB
After warm up time of 20 min
Auto λ mode Yes (with VIAVI compatible power meters)
In-line Broadband Power Meter (Hardware Option)
Wavelengths
E41OTDRPM
Calibrated 1310/1490/1550/1625/1650 nm; Selectable: 1310 to 1650 nm in 1 nm step
Hardware option E41OTDRPM
Power range
E41OTDRPM
-3 to -55 dBm
Hardware option E41OTDRPM
Accuracy
E41OTDRPM
± 0.5 dB
At calibrated wavelengths, at -30 dBm, excluding connection uncertainty
General
Size (HxWxD) 134 x 128 x 40 mm (5.28 x 5.04 x 1.58 in)
Weight 0.4 kg (0.88 lb)
Operating temperature 0°C to 50°C (+32°F to 122°F)
Additional temperature restrictions may apply based on the mainframe used
Storage temperature -20°C to +60°C (-4°F to 140°F)
Datasheet prints the lower limit as -20°F; the Fahrenheit equivalent -4°F indicates -20°C
Humidity (noncondensing) 5 to 95%
Platform compatibility T-BERD/MTS-2000, -4000 V2, -5800, OneAdvisor 800 and FTH-9000

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Construction, commissioning and troubleshooting of metro and long-haul networks
  • Tier-2 certification and maintenance of enterprise and data center networks
  • Data center interconnection
  • High fiber count/ribbon cables with automated MPO switching
  • Characterization and troubleshooting of FTTA fiber cables (macro cell towers, wireless backhaul, distributed antenna systems, cloud radio access)
  • Certification and troubleshooting of FTTH-PON networks through splitters
  • Wireless/5G x-haul and FTTx/access networks
  • Point-to-point solid core fiber links
  • Live network troubleshooting with in-service testing

Included

  • SC/PC or SC/APC test port adapter (per ordered -PC/-APC version)

Options & Accessories

Option Description
E4126B-PC 4100 B OTDR – 1310/1550 nm – PC — Module delivered with SC/PC test port adapter
E4126B-APC 4100 B OTDR – 1310/1550 nm – APC — Module delivered with SC/APC test port adapter
E41OTDRPM Power meter — Hardware option: in-line broadband power meter on the OTDR port
E41OTDRCR OTDR module calibration report
EUSCADS SC/PC (Blue) test port adapter – screw type
EUSCADS-APC SC/APC (Green) test port adapter – screw type
EULCADS LC/PC (Blue) test port adapter – screw type
EULCADS-APC LC/APC (Green) test port adapter – screw type
EUFCADS FC test port adapter – screw type
ESCREWDRIVER-SENKO Screwdrivers kit for screw type test port adapters
ETRUEBIDIR-FCOMP-PRO TrueBIDIR: Bidirectional OTDR Acquisition, on board real time analysis and averaging - All Networks — Software option installed on the mainframe; upgrade version ETRUEBIDIR-FCOMP-PRO-UPG. Not compatible with T-BERD/MTS-5800
ELOOPBACK-FCOMP-PRO Loopback: Bidirectional 2 fibers OTDR Acquisition, on board real time analysis and averaging - Access Networks — Software option installed on the mainframe; upgrade version ELOOPBACK-FCOMP-PRO-UPG. Not compatible with T-BERD/MTS-5800
ECABLESLM Cable-SLM: Project cable management, up to 10,000 fibers — Software option installed on the mainframe; upgrade version ECABLESLM-UPG
EFTTHSLM-BASE FTTH-SLM Base: Tailored OTDR App. for FTTH Networks (Basic PON Architectures) — Software option installed on the mainframe
EFTTHSLM FTTH-SLM: Tailored OTDR App. for FTTH Networks (Advanced PON Architectures, including Unbalanced/tap couplers) — Software option installed on the mainframe

Documents & Resources

OTDR A/B/C Modules - 4100 Series
datasheet · PDF
OTDR Launch and Receive Cables
datasheet · PDF
OTDR application User Manual: 4100 Series OTDR modules, and SmartOTDR
manual · PDF
OneAdvisor 800 Fiber Platform - OTDR Modules (4100 Series) Power Meter option
manual · PDF
OneAdvisor 1000 - 4100-series OTDR, Expert OTDR
manual · PDF
OneAdvisor 1000 - 4100-series OTDR, Smart Test Assistant
manual · PDF
Quick Card: T-BERD/MTS-2000 - 4100-series OTDR, Expert OTDR
manual · PDF
Quick Card: T-BERD/MTS-5800 - 4100-series OTDR, Expert OTDR
manual · PDF
Quick Card: T-BERD/MTS-5800 - 4100-series OTDR, Smart Test Assistant
manual · PDF
T-BERD/MTS-2000 - 4100-series OTDR, Smart Test Assistant
manual · PDF
T-BERD/MTS-4000 - 4100-series OTDR, Smart Test Assistant
manual · PDF
T-BERD/MTS-4000 – 4100-Series OTDR, Expert OTDR
manual · PDF
OneAdvisor 800 Fiber Platform - Expert OTDR
manual · PDF
OneAdvisor 800 Fiber Platform - FTTA OTDR, Cell Tower Construction and Maintenance
manual · PDF
OneAdvisor 800 Fiber Platform - OTDR Smart Test Assistant
manual · PDF
OneAdvisor 800 Fiber Platform - OTDR Testing, Tips and Tricks
manual · PDF
OneAdvisor 800 Fiber Platform - Real Time Testing with Expert OTDR
manual · PDF
OneAdvisor 800 Fiber Platform - Real Time Testing with OTDR Smart Test Assistant
manual · PDF
OneAdvisor 800 Wireless Platform - Cable and Antenna Testing, Fiber (OTDR) Testing
manual · PDF
T-BERD/MTS-4000 V2 - Real Time Testing with OTDR Expert
manual · PDF
T-BERD/MTS-4000 V2 - Real Time Testing with OTDR Smart Test Assistant
manual · PDF
T-BERD/MTS-5800 - FTTA OTDR, Cell Tower Maintenance
manual · PDF
T-BERD/MTS-5800 - Real Time Testing with Expert OTDR
manual · PDF
T-BERD/MTS-5800 - Real Time Testing with OTDR Smart Test Assistant
manual · PDF
T-BERD/MTS-5800 - E4100 Module Optical Insertion Loss
manual · PDF
T-BERD/MTS-5800 - E4100 Module Optical Light Source Option
manual · PDF
T-BERD/MTS-5800 - E4100 Module Optical Power Meter
manual · PDF
FTTA SmartLink Mapper (SLM) application user manual
manual · PDF
FTTH SmartLink Mapper (SLM) application user manual
manual · PDF
FTTA Installation and Maintenance Testing Quick Start Guide, Vol. 2
manual · PDF
OTDR Solutions: T-BERD/MTS-2000 V2, -4000 V2, -5800, OneAdvisor and CellAdvisor 5G Platforms
brochure · PDF
FTTH-Smart Link Mapper (FTTH-SLM)
brochure · PDF
Understanding Optical Time Domain Reflectometry (OTDR)
brochure
Test and Certification Solutions for Contractors
brochure · PDF
Test and Monitoring Solutions for Fiber to the Antenna (FTTA)
brochure · PDF
Test and Monitoring Solutions for Fiber to the Home (FTTH)
brochure · PDF
Improving OTDR measurement accuracy of a high K fiber pigtail
app note · PDF
Maintenance and Troubleshooting of a PON Network with an OTDR
app note · PDF
Important Factors for Choosing an Optical Time Domain Reflectometer (OTDR)
app note · PDF
Measure OTDR, return, and insertion loss on a single port to characterize optical links
app note · PDF
Essentials of Fiber to the Antenna: Fiber Certification
app note · PDF
Transform Fiber Construction Certification with the VIAVI StrataSync Test Process Automation (TPA) Suite
app note · PDF
Data Center Use Case Test Guide
app note · PDF
Reference Guide to Fiber Optic Testing: Volume 1
app note
Reference Guide to Fiber Optic Testing: Volume 2
app note
Tier 2 OTDR and Connector Certification of Entreprise Networks
other · PDF
Comparing true bi-directional analysis and loopback testing - VIAVI Perspectives Blog Post
other
OTDR 2.0 Test Application Video Gallery
other
Choosing the best OTDR Acquisition Method
other
Choosing the best OTDR Testing Application on the T-BERD/MTS
other
VIAVI Care Support Plans
other · PDF
T-BERD/MTS-2000 Software
software
T-BERD/MTS-4000 Software
software
T-BERD/MTS-4000 V2 Software
software