4100 Series OTDR Module E4118FB65-APC Filtered 1650 nm In-Service OTDR Module (4100 B)
VIAVI 4100 B OTDR module with a single filtered 1650 nm wavelength for in-service troubleshooting of live optical networks.
- Module variant
- 4100 B
- Wavelength configuration
- Filtered 1650 nm – APC
- Central Wavelength (1650 nm)
- 1650 ± 10/-5 nm
- RMS Dynamic Range (1650 nm)
- 41 dB
Overview
The VIAVI E4118FB65-APC is a 4100 B OTDR module equipped with a single filtered 1650 nm wavelength and an SC/APC test port. The filtered wavelength is dedicated to in-service troubleshooting: the module can test a fiber while live traffic is present on the transmission wavelengths, with live wavelength isolation of more than 45 dB from 1260 to 1620 nm. Permanent live traffic detection protects transmission equipment and avoids poor measurement results.
As a member of the 4100 Series, the module fits the T-BERD/MTS-2000, T-BERD/MTS-4000 V2, T-BERD/MTS-5800, OneAdvisor 800 and FTH-9000 platforms. Module portability allows fiber test capability to be moved between VIAVI platforms that also cover coax and RF, active xWDM, MPO/ribbon cable or network-layer tests such as Ethernet, BERT and CPRI.
The 4100 B optical specification provides 41 dB RMS dynamic range at 1650 nm, up to 256,000 acquisition points, a 0.65 m event dead zone and a 45 m attenuation dead zone through a PON splitter. Pulse widths range from 5 ns to 20 µs and the distance display range reaches 260 km.
Analysis and workflow software
SmartLink Mapper (SLM) analyzes the trace, identifies passive optical elements and represents them as icons in a fiber link map with pass/fail information, with direct correlation between the SmartLink, Trace and Table views. SmartTEST guides the user through setup, testing, result review and reporting in four steps. Optional mainframe software adds TrueBIDIR and Loopback bidirectional OTDR analysis (FiberComplete PRO), Cable-SLM project management for high fiber count cables and FTTH-SLM applications for PON architectures. Test Process Automation (TPA) connects the instrument to cloud-based job assignment and results submission.
An in-line broadband power meter is available as a hardware option on the OTDR port.
Key Features
- Single filtered 1650 nm wavelength dedicated to in-service troubleshooting
- 4100 B optical performance: 41 dB RMS dynamic range at 1650 nm
- Up to 256,000 acquisition points and 4 cm minimum sampling resolution
- Live wavelength isolation >45 dB from 1260 to 1620 nm
- Instantaneous automatic live traffic detection avoids interference with or damage to optical transmitters
- OTDR test port health check on every test to ensure good launch conditions
- Embedded launch cable measurement feature
- SmartLink Mapper (SLM) icon-based results view with pass/fail analysis
- Easy toggle between SmartLink, Trace and Table views with direct correlation of a selected event
- SmartTEST assistant guides the user through setup, testing, result review and reporting in four steps
- Touch gesture control user interface with assistant apps
- Module portability between T-BERD/MTS, OneAdvisor 800 and FTH-9000 platforms
- Optional TrueBIDIR on-board real-time bidirectional OTDR analysis (FiberComplete PRO)
- Optional Loopback bidirectional 2-fiber OTDR acquisition for access networks
- Automated batch testing with MPO-based multifiber switches, up to 192 ports
- Optional Cable-SLM project management for high fiber count cables, up to 10,000 fibers
- Optional FTTH-SLM applications for basic and advanced PON architectures including unbalanced/tap couplers
- Optional in-line broadband power meter on the OTDR port
- Cloud-based job assignment and instant results submission with Job Manager
- SC/APC test port adapter with interchangeable screw-type adapters
- Laser safety Class 1 - IEC 60825-1:2014
Specifications
| Module variant | 4100 B |
|---|---|
| Wavelength configuration | Filtered 1650 nm – APC |
| Central Wavelength (1650 nm) |
1650 ± 10/-5 nm
Laser at 25°C measured at 10 µs
|
| RMS Dynamic Range (1650 nm) |
41 dB
The one-way difference between the extrapolated backscattering level at the start of the fiber and the RMS noise level, after 3 minutes averaging
|
| Pulse Widths | 5 ns to 20 µs |
| Event Dead Zone |
0.65 m
Measured at ±1.5 dB down from the peak of an unsaturated reflective event, using 5 ns pulse width at 1310 nm
|
| Attenuation Dead Zone |
3 m
Measured at ±0.5 dB down from the linear regression using a FC/UPC-type reflectance, using 5 ns pulsewidth at 1310 nm
|
| Attenuation Dead Zone (PON Splitter) |
45 m
4100B measured on a 16 dB loss (typical 1x32 split ratio) non-reflective splitter at 1310 nm, using 200 ns pulsewidth
|
| Live Wavelength Isolation | >45 dB; 1260 to 1620 nm |
| Distance Display Range | 0.1 up to 260 Km |
| Distance Accuracy |
± (0.5 m + sampling resolution + 0.001% x distance)
Excluding Group Index uncertainties
|
| Sampling Points | Up to 256,000 |
| Sampling Resolution | 4 cm min |
| Attenuation Linearity | ± 0.03 dB/dB |
| Reflectance Accuracy | ± 2 dB |
| Laser Safety Class | Class 1 - IEC 60825-1:2014 |
|
Wavelengths
E41OTDRPM
|
Calibrated 1310/1490/1550/1625/1650 nm; Selectable: 1310 to 1650 nm in 1 nm step
Hardware option E41OTDRPM
|
|---|---|
|
Power Range
E41OTDRPM
|
-3 to -55 dBm
Hardware option E41OTDRPM
|
|
Accuracy
E41OTDRPM
|
± 0.5 dB
At calibrated wavelengths, at -30 dBm, excluding connection uncertainty
|
| Size (HxWxD) | 134 x 128 x 40 mm (5.28 x 5.04 x 1.58 in) |
|---|---|
| Weight | 0.4 kg (0.88 lb) |
| Operating Temperature |
0°C to 50°C (+32°F to 122°F)
Additional temperature restrictions may apply based on the mainframe used
|
| Storage Temperature |
-20°F to +60°C (-4°F to 140°F)
As printed in the datasheet
|
| Humidity (noncondensing) | 5 to 95% |
| Test Port |
SC/APC test port adapter
All modules are delivered with a SC/PC or SC/APC test port adapter; APC version
|
| Platform Compatibility | T-BERD/MTS-2000, -4000 V2, -5800, OneAdvisor 800 and FTH-9000 |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- In-service troubleshooting of live optical networks
- Construction, commissioning and troubleshooting of metro and long-haul networks
- Tier-2 certification and maintenance of enterprise and data center networks
- High fiber count/ribbon cables with automated MPO switching
- Characterization and troubleshooting of FTTA fiber cables
- Certification and troubleshooting of FTTH-PON networks through splitters
- Unbalanced, tapered and indexed splitter architectures
- Data center interconnection
- Wireless/5G x-haul access networks
Included
- SC/APC test port adapter
Options & Accessories
| Option | Description |
|---|---|
| E41OTDRPM | Power meter — In-line broadband power meter hardware option |
| E41OTDRCR | OTDR module calibration report |
| EUSCADS/-APC | SC/PC (Blue), SC/APC (Green) test port adapter – screw type |
| EULCADS/-APC | LC/PC (Blue), LC/APC (Green) test port adapter – screw type |
| EUFCADS | FC test port adapter – screw type |
| ESCREWDRIVER-SENKO | Screwdrivers kit for screw type test port adapters |
| ETRUEBIDIR-FCOMP-PRO/-UPG | TrueBIDIR: Bidirectional OTDR Acquisition, on board real time analysis and averaging - All Networks — Software option, generic, to be installed on the mainframe. Not compatible with T-BERD/MTS-5800 |
| ELOOPBACK-FCOMP-PRO/-UPG | Loopback: Bidirectional 2 fibers OTDR Acquisition, on board real time analysis and averaging - Access Networks — Software option, generic, to be installed on the mainframe. Not compatible with T-BERD/MTS-5800 |
| ECABLESLM/-UPG | Cable-SLM: Project cable management, up to 10,000 fibers — Software option, generic, to be installed on the mainframe |
| EFTTHSLM-BASE | FTTH-SLM Base: Tailored OTDR App. for FTTH Networks (Basic PON Architectures) — Software option, generic, to be installed on the mainframe |
| EFTTHSLM | FTTH-SLM: Tailored OTDR App. for FTTH Networks (Advanced PON Architectures, including Unbalanced/tap couplers) — Software option, generic, to be installed on the mainframe |