VIAVI MAP mORL-A1 MORL-A13500-STD-M100-MFA Single-Mode IL/RL Meter 1310/1550 nm FC/APC
Single-mode insertion loss and return loss meter module for the VIAVI MAP-Series, with 1310 and 1550 nm sources and an FC/APC interface.
- Wavelengths (2-Wavelength Version)
- 1310, 1550 nm
- Connector
- FC/APC
Overview
The MORL-A13500-STD-M100-MFA is the standard (non-bidirectional) two-wavelength single-mode version of the VIAVI mORL-A1 insertion loss and return loss meter. It provides 1310 nm and 1550 nm sources, an integrated power meter and an FC/APC interface for 9 µm single-mode fiber, and installs in a VIAVI MAP-Series chassis as part of the Passive Component/Connector Test (PCT) solution.
Measurement principle
Insertion loss is measured with the power meter method, using launch power monitoring and depolarization technology for 0.001 dB resolution. Return loss is measured with time-domain technology, often described as mandrel-free, which removes the need for manual terminations during setup and measurement and also reports DUT length. RL measurements run in parallel with IL using the same optical stimulus.
PCT software and automation
The PCT application runs natively on the MAP chassis in two versions, PCT Max and PCT Lite, and offers instrument mode, script (DUT aware) mode and port mapping. Script mode automates test sequences and stores results in a password-protected database, with report and label printing. A full set of SCPI remote commands is available over LAN or GPIB, and the companion PCT Control Center PC application manages DUT definitions, report templates and serial number batches.
System expansion
The module can be combined with MAP optical switches (mOSW-C1) to expand a single output up to 64 channels, with remote power meter heads including the mOPM-C1RHPM Remote Head Polarity Mapper, and with software licenses such as port mapping, Enhanced TDR and bidirectional upgrade. The PCT is compatible with current MAP-300 and MAP-200 chassis with the exception of the MAP-220.
Key Features
- 1310 nm and 1550 nm sources with integrated power meter
- Single-mode 9 µm fiber with FC/APC connector interface
- Mandrel-free time-domain return loss measurement with length measurement
- IL measured by power meter method with 0.001 dB display resolution
- 80 dB RL dynamic range
- Measures jumpers as short as 70 cm in as quickly as 6 seconds for two wavelengths
- Scalable modular platform from 1 to 1,000+ DUT channels
- Small footprint of 25% of competing solutions
- Integrated automation via SCPI and no-code scripting
- Database interface and report generation
- MPO and MTP capable with simultaneous polarity measurement when paired with the Remote Head Polarity Mapper
- FastIL prescreening at 0.2 s per channel
- Linux-based MAP-Series operating system
Specifications
| Wavelengths (2-Wavelength Version) | 1310, 1550 nm |
|---|---|
| Connector |
FC/APC
From ordering description: IL/RL Meter 1310 /1550nm SMF FC/APC
|
| Single Fiber | Single-Mode 9 µm core |
|---|
| Initializing Time | < 4s |
|---|---|
| Averaging Options Per Wavelength |
0.5, 1, 2, 5, 10s
The MAP-Based IL/RL Testing Solution data sheet lists 2, 5, 10s
|
| Total Time (IL, RL, Polarity) for 2 wavelengths |
23s (12 channels), 44s (24 channels)
With mOPM-C1RHPM Remote Head Polarity Mapper
|
| Prescreening with FastIL |
0.2s per channel
With mOPM-C1RHPM; requires MAP-300 FW 13.0+ with PCT
|
| Display Resolution | 0.001 dB |
|---|---|
| Total IL Uncertainty |
± 0.02 dB
After valid zero loss, total expanded uncertainty (2σ), reconnecting the same connector and OPM adaptor, temperature ±1°C, using internal source; IL uncertainty from launching condition not included
|
| Additional Uncertainties Due to 1xN Switching |
± 0.01 dB
If mOSW-C1 added
|
| Additional Uncertainties Due to Fiber Position in the Integrating Sphere |
± 0.03 dB
24-channel ribbon fiber
|
| Display Resolution | 0.01 dB |
|---|---|
| RL Dynamic Range | 80 dB |
| DUT Length, DUT reflections (both ends) < 40 dB | > 170 cm |
| DUT Length, DUT reflections (both ends) > 40 dB | > 70 cm |
| Return Loss Repeatability, 30 to 65 dB |
± 0.1 dB
At 5 s averaging time and 200 m range; 10 measurements with a stable connection of a 3 m patch cord
|
| Return Loss Repeatability, 65 to 70 dB |
± 0.2 dB
At 5 s averaging time and 200 m range; 10 measurements with a stable connection of a 3 m patch cord
|
| Return Loss Repeatability, 70 to 75 dB |
± 0.4 dB
At 5 s averaging time and 200 m range; 10 measurements with a stable connection of a 3 m patch cord
|
| Return Loss Repeatability, 75 to 80 dB |
± 1.5 dB
At 5 s averaging time and 200 m range; 10 measurements with a stable connection of a 3 m patch cord
|
| Return Loss Accuracy, 30 to 70 dB |
± 1.0 dB
At 5 s averaging time and 200 m range
|
| Return Loss Accuracy, 70 to 75 dB |
± 1.7 dB
At 5 s averaging time and 200 m range
|
| Return Loss Accuracy, 75 to 80 dB |
± 3.0 dB
At 5 s averaging time and 200 m range
|
| Time Penalty Measuring IL/RL |
0s
Requires MAP-300 FW 13.0+ with PCT
|
|---|---|
| Multi Fiber | All connector formats – MPO, MXC, SN-MT, FAU types, Proprietary Lensed Connectors, Multicore |
| Minimum Resolvable Fiber Pitch | 30 μm |
| Maximum Tolerance for IL in Polarity | > 20 dB |
| Accuracy Impact (RL) | 0 dB |
| Accuracy Impact (IL, compared to RHIP) | 0 dB |
| Recalibration Period | 1 year |
|---|---|
| Compliance |
CE, CSA/UL/IEC61010-1, and LXI Class C requirements
MAP mORL-A1 modules installed in a MAP Series chassis
|
| Warm-up Time | 20 min |
|---|---|
| Operating Temperature, Humidity | 25 ± 5°C non-condensing humidity |
| Storage Temperature | - 30 to + 60°C |
| Size (W x H x D) | 4.06 x 13.26 x 37.03 cm (1.6 x 5.22 x 14.58 in) |
|---|---|
| Weight |
1.2 kg (2.65 lb)
Approximately
|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- IL, RL and length testing of optical connectors and cable assemblies
- Testing structured-cabling solutions and optical splitters
- Automated testing of multifiber assemblies such as MPO
- Verifying continuity and polarity of large multifiber assemblies
- Measuring RL of line cards and receptacle-based transponders
- R&D, production and qualification test environments
Options & Accessories
| Option | Description |
|---|---|
| MSUP-BIDIUPG | MAP-300 mORL Bi-di upgrade license — Requires high directivity mOSW 2x2 |
| MSUP-300A-FIT | MAP-300 fiber connector inspection app — Requires probe |
| MSUP-300A-PCTMAPPING | MAP-300 PCT polarity and port mapping application add-on |
| MSUP-300A-PCTREMDB | MAP-300 PCT remote centralized database connection key |
| MSUP-300A-SBSC | MAP-300 PCT driver for legacy SB/SC series switches |
| MSUP-300A-PCT-TDR | MAP-300 Enhanced PCT TDR License |
| MSUP-300A-PCTCASCADE | MAP-300 PCT Switch Cascade |
| MSUP-300A-PCTLOGGING | MAP-300 PCT Continuous Mode Logging License |
| MSUP-300A-SEIL | MAP-300 Single Ended Insertion Loss license |
| MSUP-FIT | MAP-200 Super Application Fiber Inspection (FIT) |
| MSUP-PCTMAPPING | MAP-200 Super Application PCT Mapping |
| MSUP-PCTREMDB | MAP-200 CT Remote Database Connection Key |
| MSUP-SBSC | MAP-200 driver for legacy SB/SC series switches |
| MOSW-C111C004B0-MXXX-MYY | Single 1 x 4 switch, bulkheads — XXX = fiber type code, YY = connector type code |
| MOSW-C111C008B0-MXXX-MYY | Single 1 x 8 switch, bulkheads — XXX = fiber type code, YY = connector type code |
| MOSW-C111C012B0-MXXX-MYY | Single 1 x 12 switch, bulkheads (Dual width module) — XXX = fiber type code, YY = connector type code |
| MOSW-C111C024B0-MXXX-MYY | Single 1 x 24 switch, bulkheads (Dual width module) — XXX = fiber type code, YY = connector type code |
| MOPM-C1RH1 | Single channel remote interface cassette |
| MOPM-C1RH2 | Dual channel remote interface cassette |
| MOPM-C1RH4 | Quad channel remote interface cassette |
| MOPM-C1RHPCT | 2mm InGaAs PCT system remote head |
| MOPM-C1RHIP | Integrated PCT system remote head |
| MOPM-C1RHPM | Remote Head Polarity Mapper — Simultaneous IL/RL/Polarity remote head; requires MOPM-C1RH1 base cassette |
| AC500 | FC/PC-FC/PC Universal Connector Adapter — Replacement mating sleeve |
| AC501 | FC/PC-SC/PC Universal Connector Adapter — Replacement mating sleeve |
| AC502 | FC/APC-FC/APC Universal Connector Adapter — Replacement mating sleeve |
| AC503 | FC/APC-SC/APC Universal Connector Adapter — Replacement mating sleeve |