VIAVI MAP-Series platform family with mORL IL/RL test modules, fiber probe and microscope
VIAVI / mORL-A1 / Passive Component Test
MORL-A11308-BID-M112-MFA

mORL-A1 MORL-A11308-BID-M112-MFA Multimode Bidirectional IL/RL Meter Module (850/1300 nm, Dual Output OM3/OM1)

Multimode mORL-A1 IL/RL meter module for MAP-Series with 850/1300 nm sources, dual OM3/OM1 output and bidirectional FC/APC testing.

Description
IL/RL meter 850/1300 nm Dual Output OM3/OM1 MMF Bidirectional FC/APC
Bidirectional option
Internal 2x2 switch
Datasheet

Overview

The VIAVI MORL-A11308-BID-M112-MFA is a multimode insertion loss (IL) and return loss (RL) meter module in the mORL-A1 family. It is part of the VIAVI Passive Component/Connector Test solution (PCT) for the MAP-Series platform and is used to test IL, RL, physical length and polarity of optical connectors, cable assemblies, structured-cabling products and splitters.

This configuration provides 850 nm and 1300 nm sources with a dual-fiber output that tests both 50 µm (OM3) and 62.5 µm (OM1) fiber from the same module, with the fiber type selected in software. The module has an FC/APC interface and an integrated power meter. IL can be measured with either the laser sources or the low-power LED sources, which have lower coherence and reduce speckle effects on the power meter surface. Multimode IL performance meets the IEC 61280-4-1 Encircled Flux requirements.

Bidirectional testing

The bidirectional (BID) option adds an internal 2x2 switch. Together with the time-domain RL measurement, it measures RL on both connectors of a jumper from a single connection by using multiple programmable windows. This removes the need to measure the jumper in the reverse direction and can also be used to test hybrid assemblies. RL from 15 to 60 dB can be measured concurrently with IL in less than 2 s per wavelength.

Software and integration

The module runs the PCT application on the MAP chassis, available as PCT Max and PCT Lite. It offers instrument mode, script (DUT-aware) mode with a local database, and port mapping. A full SCPI command set is available over LAN or GPIB. The PCT Control Center PC application manages DUT definitions, report templates and serial number batches. The mORL is often used together with the MAP optical switch (mOSW) and remote optical power meter (mOPM) modules.

Key Features

  • 850 nm and 1300 nm multimode sources
  • Dual output tests 50 µm (OM3) and 62.5 µm (OM1) fiber from one module, software selectable
  • Internal 2x2 switch for bidirectional IL/RL testing from a single connection
  • Selectable LED or laser source for insertion loss
  • Mandrel-free, time-domain return loss measurement with length measurement
  • Multimode IL meets IEC 61280-4-1 Encircled Flux requirements
  • 0.001 dB IL display resolution
  • Small footprint, 25% of competing solutions
  • Integrated automation via SCPI and no-code scripting
  • Database interface and report generation
  • MPO and MTP capable with simultaneous polarity measurement
  • Scales from 1 to 1,000+ DUT channels
  • FastIL prescreening at 0.2 s per channel
  • Port mapping verifies multifiber MPO cassette continuity and polarity in less than 15 seconds

Specifications

Configuration
Description IL/RL meter 850/1300 nm Dual Output OM3/OM1 MMF Bidirectional FC/APC
Bidirectional option Internal 2x2 switch
mBID code option
Source
Wavelengths (2-Wavelength Version) 850, 1300 nm
Fiber Types
Dual Fiber 50 µm core (OM3) and 62.5 µm core (OM1). Software selectable
Measurement Time
Initializing Time < 4s
Averaging Options Per Wavelength 0.5, 1, 2, 5, 10s
Older MAP-based datasheet lists 2, 5, 10s
Total Time (IL, RL, Polarity) for 2 wavelengths 23s (12 channels); 44s (24 channels)
Insertion Loss
Modes LED or laser (software selectable)
Display Resolution 0.001 dB
Total IL Uncertainty ± 0.05 dB
After valid zero loss, total expanded uncertainty (2σ), reconnecting the same connector and OPM adaptor, temperature ±1°C, using internal source (incl. LED mode); IL uncertainty from launching condition not included
Additional Uncertainties Due to 1xN Switching (if mOSW-C1 added) ± 0.01 dB
Additional Uncertainties Due to Fiber Position in the Integrating Sphere ± 0.03 dB
24-channel ribbon fiber
Return Loss
Display Resolution 0.01 dB
Return Loss Repeatability 15 to 60 dB ± 0.2 dB
At 5 s averaging time and 200 m range; 10 measurements with a stable connection of a 3 m patch cord
Return Loss Accuracy 15 to 20 dB ± 1.8 dB; 20 to 60 dB ± 1.3 dB
At 5 s averaging time and 200 m range
RL Measurement Range 15 to 60 dB
Concurrent with IL measurements in less than 2s per wavelength
Recalibration Period 1 year
Environmental
Warm-up Time 20 min
Operating Temperature, Humidity 25 ± 5°C non-condensing humidity
Storage Temperature - 30 to + 60°C
Physical
Size (W x H x D) 4.06 x 13.26 x 37.03 cm (1.6 x 5.22 x 14.58 in)
Weight 1.2 kg (2.65 lb)
Approximately
Compliance
Safety and Standards CE, CSA/UL/IEC61010-1, and LXI Class C requirements
When installed in a MAP Series chassis
Multimode IL Meets IEC 61280-4-1 Encircled Flux requirements

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • IL, RL and length testing of optical connectors and cable assemblies
  • Structured-cabling solution testing
  • Optical splitter testing
  • Automated testing of multifiber assemblies such as MPO
  • Multimode fiber-based device testing
  • Verifying continuity and polarity of large multifiber assemblies
  • Measuring RL of line cards and receptacle-based transponders
  • Hybrid assembly testing

Options & Accessories

Option Description
MOSW-C111C004B0-MXXX-MYY Single 1 x 4 switch, bulkheads — XXX = fiber type code, YY = connector type code
MOSW-C111C008B0-MXXX-MYY Single 1 x 8 switch, bulkheads — XXX = fiber type code, YY = connector type code
MOSW-C111C012B0-MXXX-MYY Single 1 x 12 switch, bulkheads (Dual width module) — XXX = fiber type code, YY = connector type code
MOSW-C111C024B0-MXXX-MYY Single 1 x 24 switch, bulkheads (Dual width module) — XXX = fiber type code, YY = connector type code
MOPM-C1RH1 Single channel remote interface cassette
MOPM-C1RH2 Dual channel remote interface cassette
MOPM-C1RH4 Quad channel remote interface cassette
MOPM-C1RHPCT 2mm InGaAs PCT system remote head
MOPM-C1RHIP Integrated PCT system remote head
MOPM-C1RHPM Remote Head Polarity Mapper — Requires MAP-300 FW 13.0+ with PCT
MSUP-300A-FIT MAP-300 fiber connector inspection app — Requires probe
MSUP-300A-PCTMAPPING MAP-300 PCT polarity and port mapping application add-on
MSUP-300A-PCTREMDB MAP-300 PCT remote centralized database connection key
MSUP-300A-SBSC MAP-300 PCT driver for legacy SB/SC series switches
MSUP-300A-PCT-TDR MAP-300 Enhanced PCT TDR License
MSUP-300A-PCTCASCADE MAP-300 PCT Switch Cascade
MSUP-300A-PCTLOGGING MAP-300 PCT Continuous Mode Logging License
MSUP-300A-SEIL MAP-300 Single Ended Insertion Loss license
MSUP-FIT MAP-200 Super Application Fiber Inspection (FIT)
MSUP-PCTMAPPING MAP-200 Super Application PCT Mapping
MSUP-PCTREMDB MAP-200 CT Remote Database Connection Key
MSUP-SBSC MAP-200 driver for legacy SB/SC series switches
AC500 FC/PC-FC/PC Universal Connector Adapter — Replacement mating sleeve
AC501 FC/PC-SC/PC Universal Connector Adapter — Replacement mating sleeve
AC502 FC/APC-FC/APC Universal Connector Adapter — Replacement mating sleeve
AC503 FC/APC-SC/APC Universal Connector Adapter — Replacement mating sleeve

Documents & Resources

Insertion Loss/Return Loss Testing (mORL)
datasheet · PDF
MAP-Based Insertion Loss/ Return Loss Testing Solution
datasheet · PDF
MAP Series PCT Enhanced TDR
datasheet · PDF
mOPM-C1RHPM Remote Head Polarity Mapper
datasheet · PDF
Multiple Application Platform
datasheet · PDF
Novel Insertion Loss Measurements VIAVI PCT Enhanced TDR
app note · PDF
Comparing Optical Return Loss (ORL) Measurement Methods
app note · PDF
New Passive Component/Connector Test (PCT) for the MAP-300
other
Introduction to Insertion Loss Measurements
app note · PDF
The Skeleton in Your Closet: EF Compliance Impact on Insertion Loss Testing
app note · PDF
Future Proofing Your IL/RL Testing
brochure · PDF
PCT System now available on MAP-300
other
How-To Videos: MAP-220 | PCT-rm
other
Low-Loss Requirements Drive Changes in Measurement Designs
app note · PDF
Measurement Integrity in IL/RL Testing
app note · PDF
MAP-202, MAP-204, MAP-220 Software
software
MAP-230, MAP-280 Software
software
Passive Component/Connector Test Solution
brochure · PDF
Inspection, Cleaning and Test Solutions for CS, SN, and MDC Fiber Connectors
brochure · PDF
Inspection, Cleaning and Test Solutions for MMC Connectors and TMT Ferrule Technology
brochure · PDF
MAP Series: Power Meter AC Detector Adaptors
brochure · PDF
Optical Manufacturing and Test Platform Catalog
brochure · PDF
VIAVI PCT Calibration
other · PDF
MAP-300 DUT Setup with PCTlite
other
High-Speed Fiber Array Unit (FAU) Testing with MAP-300
app note · PDF
Easy Environmental and Shock Testing of Optical Passive Components
brochure · PDF
FastIL: Revolutionizing Connectivity Testing
brochure · PDF
Testing, Inspection and Cleaning Solutions for Optical Connector Manufacturers
brochure · PDF
Universal Connector/Adapter System
brochure · PDF
FVAi-2030 Benchtop Microscope: Overview
other
Solutions Overview for Optical Connector Manufacturers
other