MAP mEDFA-C1 MEDFA-C12CA Dual Preamp Erbium Doped Fiber Amplifier Module
Dual independent low-noise C-band erbium-doped fiber preamplifier module for the VIAVI MAP-300 and MAP-200 platforms.
- Version
- Dual Preamp
- Amplifiers per Module
- 2
- Input Type
- Single Channel
- Band
- C
Overview
The VIAVI MEDFA-C12CA is the dual preamplifier variant of the Multiple Application Platform (MAP) Erbium Doped Fiber Amplifier (mEDFA-C1) module family. It contains two independent, standard-power, extended C-band single-channel amplifiers of the low-noise-figure CA type in one module, which improves test system density in applications that require more than one preamplifier.
The mEDFA-C1 is a third-generation amplifier design intended for systems-lab use and optical test and measurement applications. Low-noise preamplifiers of this type are used in test automation where system path loss requires the test signal power to be boosted before it reaches the device under test, while keeping OSNR impairments to a minimum. The CA variant has no gain and power control, minimising noise figure while providing enough gain to bring the test signal to the required power.
Measurement principle
The module optics consist of an erbium-doped fiber amplifier gain stage with supporting optical components designed to achieve maximum output power at the bulkhead-mounted optical connector while maximising input/output isolation. Light passing through the erbium-doped fiber is amplified by exciting the erbium atoms.
Platform and control
The mEDFA-C1 belongs to the LightDirect module family within the MAP series, characterised by a simple control interface and single-function design. It is compatible with all current MAP-300 and MAP-200 chassis. The MAP platform complies with LAN Extensions for Instrumentation (LXI), provides IVI drivers for environments such as LabVIEW, Visual C++, Visual Basic and LabWindows, and its commands generally conform to SCPI. The MAP-300 GUI is accessed through a web browser or remote VNC and allows setting the current mode set point and pump laser state.
Key Features
- Two independent low-noise C-band preamplifiers in one module
- Noise figure ≤ 3.7 dB at -30 dBm input
- Gain ≥ 37 dB at -30 dBm input
- Extended C-band operation from 1528 nm to 1569 nm
- FC/APC connectors
- Compatible with all current MAP-300 and MAP-200 chassis
- LXI-compliant platform with IVI drivers and SCPI commands
- Browser-based MAP-300 GUI and remote VNC access
Specifications
| Version | Dual Preamp |
|---|---|
| Amplifiers per Module | 2 |
| Input Type | Single Channel |
| Band | C |
| Gain and Power Control | No |
| Saturated Output Power | Standard |
| Part Number |
MEDFA-C12CA-M100-MFA
Dual independent, Standard power, Extended C-band amplifier, Low NF Single channel with FC/APC connectors
|
| Operating Wavelength Range |
1528 nm – 1569 nm
All optical measurements done after minimum 30 minutes warming up at constant temperature of 23±3°C
|
|---|---|
| Saturated Power |
≥ 20 dBm
-4 dBm input; measured with input signal at 1550nm
|
| Noise Figure, Pin = -4 dBm |
≤ 4.4 dB
Measured at wavelength of 1550nm
|
| Noise Figure, Pin = -20 dBm |
≤ 4.1 dB
Measured at wavelength of 1550nm
|
| Noise Figure, Pin = -30 dBm |
≤ 3.7 dB
Measured at wavelength of 1550nm
|
| Gain, Pin = -4 dBm |
≥ 24 dB
Measured at wavelength of 1550nm
|
| Gain, Pin = -20 dBm |
≥ 35 dB
Measured at wavelength of 1550nm
|
| Gain, Pin = -30 dBm |
≥ 37 dB
Measured at wavelength of 1550nm
|
| Input Output Power Monitor | No |
| PDL/PDG |
≤ 0.2dB
Measured with input power of -4dBm at 1550nm
|
| Laser Safety Class |
1M
Classified as per standard IEC60825-1:2014 with the maximum input power +4dBm
|
| Connector Type | FC/APC |
|---|---|
| Operating Temperature | 0 - 40°C |
| Operating Humidity | Maximum 95% RH, 0 to 40°C noncondensing |
| Storage Temperature | -30 to 60°C |
| Dimensions (W x H x D) | 4.06 cm x 13.26 cm x 37.03 cm |
| Weight | 2.3 kg |
| Standards |
CE, CSA/UL/IEC61010-1, LXI Class C; Class 3B in standard IEC 60825-1 (2014); complies with 21 CFR 1040.1 except deviations per Laser Notice No. 50, July 2001
When installed in a MAP chassis; stated for the mEDFA-C1 module family
|
|---|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Amplification of sensitive signals in automated test systems
- Power saturation recovery testing
- OSNR noise loading
- Amplifier emulation
- Network compliance tests
Options & Accessories
| Option | Description |
|---|---|
| AC500 | FC/PC-FC/PC Universal Connector Adapter — Replacement mating sleeve |
| AC501 | FC/PC-SC/PC Universal Connector Adapter — Replacement mating sleeve |
| AC502 | FC/APC-FC/APC Universal Connector Adapter — Replacement mating sleeve |
| AC503 | FC/APC-SC/APC Universal Connector Adapter — Replacement mating sleeve |
| CleanBlast | CleanBlast fiber end-face cleaning system — Optional inspection and cleaning accessory, available in benchtop and portable versions |
| FiberChek | FiberChek probe microscope — Optional handheld, autonomous fiber inspection probe |
| P5000i | P5000i fiber microscope — Optional automated fiber inspection and analysis probe with PASS/FAIL capability |