VIAVI MAP mEDFA-C1 Erbium Doped Fiber Amplifier module
MEDFA-C11CD

VIAVI MAP mEDFA-C1 MEDFA-C11CD Max Power C-Band Erbium Doped Fiber Amplifier Module

High-power single-channel C-band MAP EDFA module with ≥ 25 dBm saturated output power and automatic gain and power control.

Amplifiers per module
1
Input type
Single Channel
Band
C
Gain and power control
Yes
Datasheet

Overview

The VIAVI MEDFA-C11CD is the Max Power variant of the Multiple Application Platform (MAP) Erbium Doped Fiber Amplifier (mEDFA-C1) module family. It is a single-channel, extended C-band amplifier with one amplifier per module, gain and power control, and input/output power monitoring. The variant is optimized to deliver the maximum allowable saturated output power for standard lab safety protocols, which suits signal splitting and power saturation recovery testing.

The mEDFA-C1 is a third-generation amplifier design intended for systems labs and optical test and measurement applications. Its simplified control and modular design allow it to be integrated without working around network management protocols, which simplifies test automation for R&D and manufacturing engineers.

Functional description

The module's optics consist of an erbium-doped fiber amplifier gain stage with supporting optical components designed to achieve maximum output power at the bulkhead-mounted optical connector while maximizing input/output isolation. An optical fiber doped with erbium amplifies light signals passing through it when the erbium atoms are excited.

Platform and control

The mEDFA-C1 belongs to the LightDirect module family, a subset of the MAP series characterized by a simple control interface and single-function design. It is compatible with all current MAP-300 and MAP-200 chassis. The MAP platform complies with LAN Extensions for Instrumentation (LXI), provides IVI drivers for environments such as LabVIEW, Visual C++, Visual Basic and LabWindows, and uses commands that generally conform to SCPI. The MAP-300 GUI is accessible through a web browser or remote VNC and allows control of the current mode set point and the pump laser state.

Key Features

  • Max Power variant optimized to deliver the maximum allowable saturated output power for standard lab safety protocols
  • Saturated power ≥ 25 dBm with -4 dBm input
  • Single-channel extended C-band operation, 1528 nm – 1569 nm
  • Automated gain and power control
  • Input and output power monitoring
  • FC/APC optical connectors
  • Part of the MAP LightDirect module family, compatible with all current MAP-300 and MAP-200 chassis
  • LXI-compliant platform with IVI drivers and SCPI-conforming commands

Specifications

Configuration
Amplifiers per module 1
Input type Single Channel
Band C
Gain and power control Yes
Saturated output power class High
High Power Single Channel Input Optical Specifications
Operating wavelength range 1528 nm – 1569 nm
All optical measurements done after minimum 30 minutes warming up, measured at constant temperature of 23±3°C
Saturated power ≥ 25 dBm
-4 dBm input; measured at wavelength of 1550nm
Noise figure (Pin = -4 dBm) ≤ 5.5 dB
Measured at wavelength of 1550nm
Noise figure (Pin = -20 dBm) ≤ 6.2 dB
Measured at wavelength of 1550nm
Gain (Pin = -4 dBm) ≥ 29 dB
Measured at wavelength of 1550nm
Gain (Pin = -20 dBm) ≥ 35 dB
Measured at wavelength of 1550nm
Input output power monitor Yes
PDL/PDG ≤ 0.2 dB
Measured with input power of -4dBm at 1550nm
Laser safety class 3B
Classified as per standard IEC60825-1:2014
Common Specifications
Connector type FC/APC
Operating temperature 0 - 40°C
Operating humidity Maximum 95% RH, 0 to 40°C noncondensing
Storage temperature -30 to 60°C
Dimensions (W x H x D) 4.06 cm x 13.26 cm x 37.03 cm
Weight 2.3 kg
Compliance
Compliance CE, CSA/UL/IEC61010-1, LXI Class C
When installed in a MAP chassis
Laser safety Class 3B in standard IEC 60825-1 (2014); complies with 21 CFR 1040.1 except deviations per Laser Notice No. 50, July 2001
When installed in a MAP chassis
Compatibility
Compatible chassis All current MAP-300 and MAP-200 chassis

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Signal splitting
  • Power saturation recovery testing
  • Amplification of sensitive signals in automated test systems
  • OSNR noise loading

Options & Accessories

Option Description
MEDFA-C11CD-M100-MFA High power, Extended C-band amplifier Single channel with Auto power and monitoring option with FC/APC
CleanBlast CleanBlast fiber end-face cleaning system — Optional inspection and cleaning tool for removing dirt and debris from connectors; available in benchtop and portable versions.
FiberChek FiberChek probe microscope — Optional one-button, fully autonomous handheld fiber inspection probe.
P5000i P5000i fiber microscope — Optional automated fiber inspection and analysis probe with PASS/FAIL capability for PCs, laptops, mobile devices and VIAVI test solutions.
AC500 FC/PC-FC/PC Universal Connector Adapter — Replacement mating sleeve
AC501 FC/PC-SC/PC Universal Connector Adapter — Replacement mating sleeve
AC502 FC/APC-FC/APC Universal Connector Adapter — Replacement mating sleeve
AC503 FC/APC-SC/APC Universal Connector Adapter — Replacement mating sleeve

Documents & Resources