VIAVI MAP mEDFA-C1 erbium doped fiber amplifier module
MEDFA-C11CA

MAP mEDFA-C1 MEDFA-C11CA Low-Noise C-Band Erbium Doped Fiber Preamplifier Module

Single-channel extended C-band EDFA preamplifier module for the MAP platform with noise figure down to ≤ 3.7 dB.

Amplifiers per module
1
Input type
Single Channel
Band
C
Gain and power control
No
Datasheet

Overview

The MEDFA-C11CA is the preamplifier variant of the VIAVI MAP Erbium Doped Fiber Amplifier (mEDFA-C1) module family. The mEDFA-C1 is a third-generation amplifier design for the systems lab and for optical test and measurement. It is part of the LightDirect module family within the Multiple Application Platform (MAP) series, and it works with all current MAP-300 and MAP-200 chassis.

The MEDFA-C11CA has one amplifier per module for single-channel input in the extended C-band. It has no gain and power control and delivers standard saturated output power. The design keeps noise figure low while giving enough gain to bring the test signal to the required power. Low-noise amplifiers like this one are used in test automation when system path loss means the test signal has to be boosted before it reaches the device under test, while keeping OSNR impairments to a minimum.

Functional description

The module has an erbium-doped fiber amplifier gain stage with supporting optical components. These are designed to give maximum output power at the bulkhead-mounted optical connector while maximizing input/output isolation. When the erbium atoms in the doped fiber are excited, the fiber amplifies light signals passing through it.

Control and remote interfaces

The module can be controlled from the front panel or over the remote interface. The MAP series complies with LXI and supports Ethernet connectivity and IVI drivers for environments such as LabVIEW, Visual C++, Visual Basic and LabWindows. Commands generally conform to SCPI. The MAP-300 chassis GUI can be opened in a web browser or over remote VNC, and it lets the user set the current mode set point and control the pump laser state.

Key Features

  • Low noise figure variant of the mEDFA-C1 family (≤ 3.7 dB at -30 dBm input)
  • Single amplifier per module for single-channel input
  • Extended C-band operation, 1528 nm – 1569 nm
  • Saturated output power ≥ 20 dBm at -4 dBm input
  • FC/APC connectors
  • Compatible with all current MAP-300 and MAP-200 chassis
  • LXI-compliant platform with SCPI commands and IVI drivers
  • Control from the front panel or over the remote interface

Specifications

Configuration
Amplifiers per module 1
Input type Single Channel
Band C
Gain and power control No
Saturated output power class Standard
Single Channel Input Optical Specifications
Operating wavelength range 1528 nm – 1569 nm
All optical measurements done after minimum 30 minutes warm-up at constant temperature of 23±3°C
Saturated power ≥ 20 dBm (-4 dBm input)
Measured with input signal at 1550nm for C-band
Noise figure, Pin = -4 dBm ≤ 4.4 dB
Measured at wavelength of 1550nm
Noise figure, Pin = -20 dBm ≤ 4.1 dB
Measured at wavelength of 1550nm
Noise figure, Pin = -30 dBm ≤ 3.7 dB
Measured at wavelength of 1550nm
Gain, Pin = -4 dBm ≥ 24 dB
Measured at wavelength of 1550nm
Gain, Pin = -20 dBm ≥ 35 dB
Measured at wavelength of 1550nm
Gain, Pin = -30 dBm ≥ 37 dB
Measured at wavelength of 1550nm
Input output power monitor No
PDL/PDG ≤ 0.2dB
Measured with input power of -4dBm at 1550nm
Laser safety class 1M
Classified as per standard IEC60825-1:2014 with the maximum input power +4dBm
Common Specifications
Connector type FC/APC
Operating temperature 0 - 40°C
Operating humidity Maximum 95% RH, 0 to 40°C noncondensing
Storage temperature -30 to 60°C
Dimensions (W x H x D) 4.06 cm x 13.26 cm x 37.03 cm
Weight 2.3 kg
Compliance
Compliance CE, CSA/UL/IEC61010-1, LXI Class C; meets the requirements of Class 3B in standard IEC 60825-1 (2014); complies with 21 CFR 1040.1 except deviations per Laser Notice No. 50, July 2001
When installed in a MAP chassis

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Amplification of sensitive signals in automated test systems
  • Power saturation recovery testing
  • OSNR noise loading
  • Amplifier emulation
  • Network compliance tests

Options & Accessories

Option Description
MEDFA-C11CA-M100-MFA Standard power, Extended C-band amplifier, Low NF Single channel with FC/APC connectors
AC500 FC/PC-FC/PC Universal Connector Adapter — Replacement part (mating sleeve)
AC501 FC/PC-SC/PC Universal Connector Adapter — Replacement part (mating sleeve)
AC502 FC/APC-FC/APC Universal Connector Adapter — Replacement part (mating sleeve)
AC503 FC/APC-SC/APC Universal Connector Adapter — Replacement part (mating sleeve)
CleanBlast CleanBlast fiber end-face cleaning system — Optional inspection and cleaning tool for removing dirt and debris from connectors; available in benchtop and portable versions
FiberChek FiberChek probe microscope — Optional one-button, fully autonomous handheld fiber inspection probe
P5000i P5000i fiber microscope — Optional automated fiber inspection and analysis probe with PASS/FAIL capability

Documents & Resources