VIAVI MAP mBBS-C1 C+L Band Broadband Light Source Module
MAP plug-in broadband ASE light source module delivering 100 mW depolarized output across the extended C-band and L-band.
- Operating Wavelength Range (C-Band)
- 1525 nm – 1568 nm
- Operating Wavelength Range (L-Band)
- 1565 – 1610 nm
- Saturated Power
- ≥ 20 dBm
- Spectral Gain Flatness
- ≤ 1.8 dB
Overview
The VIAVI Multiple Application Platform (MAP) Broadband Source (mBBS-C1) is a third-generation design based on erbium-doped fiber. It delivers 100 mW of amplified spontaneous emission (ASE) across the extended C-band and the L-band. The output is depolarized and spectrally flat to within 1.8 dB, and its power stability is better than 0.02 dB.
The module is used to measure optical components and to test telecommunications transmission. Typical uses include spectral measurements of couplers, WDMs, isolators and other passive components, noise loading during OSNR compliance tests, power loading of optical amplifiers during gain and noise figure measurements, and polarization mode dispersion (PMD) measurements. Because its output power is very stable, the source is often used to calibrate optical power meters and variable attenuators.
Optical design
The optics consist of an erbium-based gain block and supporting optical components. They are designed to deliver maximum output power at the bulkhead-mounted optical connector. In addition to the single-band C-band and L-band versions, the datasheet lists dual-output C-band versions with a 50/50 or 30/70 power split.
Platform and control
The mBBS belongs to the MAP LightDirect module family, alongside attenuators, polarization scramblers, power meters and spectrum analyzers. It works with all current MAP-300 and MAP-200 chassis, which hold 2, 3 or 8 application modules in rack-mount or benchtop form. The platform has an LXI-compliant web interface for multiple users, SCPI-based automation drivers and IVI drivers. Its graphical interface switches between a summary view and a detailed view of each module.
Key Features
- >100 mW depolarized output power over the extended C-band and the L-band
- Power flatness < 1.8 dB
- Ultra-high power stability, better than 0.02 dB
- Third-generation erbium-doped fiber-based design
- LXI-compliant interfaces and IVI drivers
- SCPI-based automation drivers
- Compatible with all current MAP-300 and MAP-200 chassis
- Single-band C-band and L-band versions, plus 50/50 and 30/70 dual-output C-band versions
Specifications
|
Operating Wavelength Range (C-Band)
MBBS-C11CA-M100-MFA
|
1525 nm – 1568 nm
All optical measurements after minimum 30 minutes warm-up at constant 23±3°C
|
|---|---|
|
Operating Wavelength Range (L-Band)
MBBS-C11LA-M100-MFA
|
1565 – 1610 nm
All optical measurements after minimum 30 minutes warm-up at constant 23±3°C
|
|
Saturated Power
MBBS-C11CA-M100-MFA, MBBS-C11LA-M100-MFA
|
≥ 20 dBm
Measured with OPM set at wavelength of 1550nm for C-band; 1590nm for L-band
|
|
Spectral Gain Flatness
MBBS-C11CA-M100-MFA, MBBS-C11LA-M100-MFA
|
≤ 1.8 dB
C-band spectral range: 1529-1565 nm; L-band spectral range: 1570-1603 nm
|
|
Total Power Stability
MBBS-C11CA-M100-MFA, MBBS-C11LA-M100-MFA
|
≤ 0.02 dB
Measured as peak to peak variation within 30 minutes
|
|
Operating Wavelength Range (C-band)
MBBS-C11C5-M100-MFA, MBBS-C11C7-M100-MFA
|
1525 nm to 1568 nm
All optical measurements after minimum 30 minute warm-up at constant 23 ±3°C
|
|---|---|
|
Saturated Power, Port 1
MBBS-C11C5-M100-MFA
|
≥ 18.5 dBm
High Power Dual Broadband Source (50/50); measured with OPM wavelength set 1550 nm
|
|
Saturated Power, Port 1
MBBS-C11C7-M100-MFA
|
≥ 17.5 dBm
Asymmetric Dual Power Broadband Source (30/70); measured with OPM wavelength set 1550 nm
|
| Saturated Power, Port 2 |
≥ 13.2 dBm
Single value printed in the datasheet table; column assignment not stated. Measured with OPM wavelength set 1550 nm
|
|
Spectral Gain Flatness
MBBS-C11C5-M100-MFA
|
≤ 3.5 dB
High Power Dual Broadband Source (50/50); C-band spectral range: 1529 to 1565 nm
|
|
Spectral Gain Flatness
MBBS-C11C7-M100-MFA
|
≤ 2.0 dB
Asymmetric Dual Power Broadband Source (30/70); C-band spectral range: 1529 to 1565 nm
|
|
Total Power Stability
MBBS-C11C5-M100-MFA, MBBS-C11C7-M100-MFA
|
≤ 0.02 dB
Measured as peak-to-peak variation within 30 minutes
|
| Laser Safety Class |
1M
Classified as per standard IEC60825-1:2014
|
|---|---|
| Fiber Type |
Single Mode Fiber
For IEC60793-2-50 Type B1.3/ ISO 11801 OS2 compliant fiber, i.e. Corning SMF-28e
|
| Connector Type | FC/APC |
| Compliance |
CE, CSA/UL/IEC61010-1, LXI Class C; Class 1M per IEC 60825-1 (2014); complies with 21 CFR 1040.1 except deviations per Laser Notice No. 50, June 24, 2007
When installed in a MAP chassis
|
| Chassis Compatibility | All current MAP-300 and MAP-200 chassis |
| Operation Temperature | 0 – 40°C |
|---|---|
| Operation Humidity | Maximum 95% RH, 0 to 40°C non condensing |
| Storage Temperature | -30 to 60°C |
| Dimensions (W x H x D) | 4.06 cm x 13.26 cm x 37.03 cm |
|---|---|
| Weight | 2.3 kg |
| MBBS-C11CA-M100-MFA | Broadband source, Extended C-band, Flattened with FC/APC connectors |
|---|---|
| MBBS-C11LA-M100-MFA | Broadband source, L-band, Flattened with FC/APC connectors |
| MBBS-C11C5-M100-MFA | 50/50 High power dual broadband source, Extended C-band, Flattened with FC/APC |
| MBBS-C11C7-M100-MFA | 30/70 Asymmetric dual power broadband source, Extended C-band with FC/APC |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Source for optical component spectral tests
- OSNR noise loading for receiver and systems compliance tests
- Power loading for optical amplifier testing
- Ultra-stable source for optical calibration systems
- Spectral measurements of couplers, WDMs and isolators
- Polarization mode dispersion (PMD) measurements
- Noise figure measurements
- Calibration of optical power meters and variable attenuators
Options & Accessories
| Option | Description |
|---|---|
| AC500 | FC/PC-FC/PC Universal Connector Adapter — Replacement part (mating sleeve) |
| AC501 | FC/PC-SC/PC Universal Connector Adapter — Replacement part (mating sleeve) |
| AC502 | FC/APC-FC/APC Universal Connector Adapter — Replacement part (mating sleeve) |
| AC503 | FC/APC-SC/APC Universal Connector Adapter — Replacement part (mating sleeve) |
| CleanBlast | CleanBlast fiber end-face cleaning system — Optional inspection and cleaning tool; available in benchtop and portable versions |
| FiberChek | FiberChek probe microscope — Optional one-button, fully autonomous handheld fiber inspection probe |
| P5000i | P5000i fiber microscope — Optional automated fiber inspection and analysis probe with PASS/FAIL capability for PCs, laptops, mobile devices and VIAVI test solutions |