VIAVI SmartClass Fiber OLP-87P PON power meter with integrated patch cord microscope
VIAVI / Optical Power Meters / PON Power Meters
OLP-87

SmartClass Fiber OLP-87 PON Power Meter for B/E/G-PON, XG(S)-PON, 10G-EPON and NG-PON2

Wavelength-selective PON power meter that measures all upstream and downstream wavelengths on live B/E/G-PON, XG(S)-PON, 10G-EPON and NG-PON2 networks.

Photo diode
InGaAs
Spectral range
Passband (1260…1625 nm)
Spectral range
Passband (1260…1360 nm, 1480…1500 nm, 1535…1565 nm)
Spectral range
Passband (1260…1280 nm, 1290…1330 nm, 1480…1500 nm, 1535…1565 nm, 1573…1583 nm)
Datasheet

Overview

The VIAVI SmartClass Fiber OLP-87 is an FTTx/PON power meter used for activating and troubleshooting B-PON, E-PON and G-PON networks, next-generation 10G PON networks such as XG-PON and 10G-EPON, and higher-capacity NG-PON2 networks. It combines a wavelength-selective power meter with pass/fail fiber inspection analysis in one portable instrument.

In through mode, the OLP-87 is connected between the OLT and ONT sides of the link and measures the individual downstream and upstream wavelengths at the same time, including burst-mode upstream signals. This lets technicians verify the power level of each service separately where several PON technologies share the same fiber, for example G-PON alongside XGS-PON or E-PON alongside 10G-EPON.

Why a wavelength-selective meter

A broadband power meter sums every wavelength present at its input, so on a multi-service PON it reports an inaccurate, typically high, reading. That can lead to unnecessary attenuation and to ONTs that fail to activate or run with marginal power. A selective PON power meter isolates each wavelength and shows which service is present, which also determines the type of CPE (ONT/ONU) to install.

Inspection and reporting

Automated pass/fail fiber end-face inspection is available with the optional P5000i microscope, or with the integrated patch cord microscope on the OLP-87P variants. Measurement results are stored on the instrument and can be downloaded to generate certification reports that document work quality against industry or customer specifications. A hands-free carrier is supplied for use inside homes or on poles.

Key Features

  • Through-mode measurement and display of voice, data and RF video signals at 1490/1550/1577 nm downstream and 1270/1310 nm upstream for B/E/G/XG(S)/10G PON
  • Individual wavelength-selective through-mode power measurement of multiple NG-PON2 downstream and upstream channels
  • Burst mode measurement for 1270 nm, 1310 nm and 1535 nm upstream signals
  • High-performance broadband power meter option
  • Storage of up to 10,000 measurement results, downloadable via USB or Ethernet
  • Automated pass/fail fiber inspection analysis with optional P5000i microscope
  • Integrated patch cord microscope version available (OLP-87P)
  • Certification report generation
  • Hands-free carrier for use inside homes or on telephone poles
  • Supports co-existence of PON services, e.g. XG(S)-PON and/or NG-PON2 on existing G-PON networks

Specifications

Selective PON Power Meters
Photo diode
2305/26, 2305/11, 2305/36, 2306/36, 2305/66, 2306/66
InGaAs
Spectral range
2305/26
Passband (1260…1625 nm)
Spectral range
2305/11, 2305/36, 2306/36
Passband (1260…1360 nm, 1480…1500 nm, 1535…1565 nm)
Spectral range
2305/66, 2306/66
Passband (1260…1280 nm, 1290…1330 nm, 1480…1500 nm, 1535…1565 nm, 1573…1583 nm)
Wavelength setting
2305/26
1310, 1490 nm
Wavelength setting
2305/11, 2305/36, 2306/36
1310, 1490, 1550 nm; Broadband: 1260…1625 nm, step size 1 nm
Wavelength setting
2305/66, 2306/66
1270, 1310, 1490, 1550, 1577 nm; Broadband: 1260…1625 nm, step size 1 nm
Resolution
2305/26, 2305/11, 2305/36, 2306/36, 2305/66, 2306/66
0.01 dB, 0.001 µW
Measurement range for power level
2305/26
1310 nm: -40…+13 dBm; 1490 nm: -50…+13 dBm
1310 nm Burst Mode: -35…+13 dBm
Measurement range for power level
2305/11, 2305/36, 2306/36
1310 nm: -40…+13 dBm; 1490 nm: -50…+13 dBm; 1550 nm: -50…+26 dBm; Broadband: -50…+13 dBm
1310 nm Burst Mode: -35…+13 dBm. Broadband in Broadband Mode when connected to Broadband Port (activated SW option required)
Measurement range for power level
2305/66, 2306/66
1270 nm: -40…+13 dBm; 1310 nm: -40…+13 dBm; 1490 nm: -50…+13 dBm; 1550 nm: -50…+26 dBm; 1577 nm: -50…+13 dBm; Broadband: -50…+13 dBm
1270/1310 nm Burst Mode: -35…+13 dBm. Broadband in Broadband Mode when connected to Broadband Port (activated SW option required). Only the present US wavelength is displayed and the other one as “LOW”
Maximum power level
2305/26
1310 nm: +17 dBm; 1490 nm: +15 dBm
Maximum power level
2305/11, 2305/36, 2306/36
1310 nm: +17 dBm; 1490 nm: +15 dBm; 1550 nm: +27 dBm; Broadband: +15 dBm
Broadband in Broadband Mode when connected to Broadband Port (activated SW option required)
Maximum power level
2305/66, 2306/66
1270 nm: +17 dBm; 1310 nm: +17 dBm; 1490 nm: +15 dBm; 1550 nm: +27 dBm; 1577 nm: +15 dBm; Broadband: +15 dBm
Broadband in Broadband Mode when connected to Broadband Port (activated SW option required)
Measurement uncertainty
2305/26
1310 nm: ± 0.5 dB; 1490 nm: ± 0.5 dB
Under reference conditions: -7 dBm (CW), nominal wavelength, 23°C ± 3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9 µm core, 8° APC), when used with SC/APC connectors
Measurement uncertainty
2305/11, 2305/36, 2306/36
1310 nm: ± 0.5 dB; 1490 nm: ± 0.5 dB; 1550 nm: ± 0.5 dB; Broadband: ± 0.2 dB
Under reference conditions: -7 dBm (CW), nominal wavelength, 23°C ± 3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9 µm core, 8° APC), when used with SC/APC connectors
Measurement uncertainty
2305/66, 2306/66
1270 nm: ± 0.5 dB; 1310 nm: ± 0.5 dB; 1490 nm: ± 0.5 dB; 1550 nm: ± 0.5 dB; 1577 nm: ± 0.5 dB; Broadband: ± 0.2 dB
Under reference conditions: -7 dBm (CW), nominal wavelength, 23°C ± 3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9 µm core, 8° APC), when used with SC/APC connectors
ORL
2305/26, 2305/36, 2306/36, 2305/66, 2306/66
> 60 dB
ORL
2305/11
> 40 dB
Pass-through insertion loss
2305/26, 2305/11, 2305/36, 2306/36, 2305/66, 2306/66
< 1.5 dB
Number of calibrated wavelengths
2305/26, 2305/11, 2305/36, 2306/36, 2305/66, 2306/66
4 (1310, 1490, 1550, 1625 nm)
Tone detection
2305/26, 2305/11, 2305/36, 2306/36, 2305/66, 2306/66
CW, 270 Hz, 1 kHz, 2 kHz
In Broadband Mode when connected to Broadband Port; when used with VIAVI Light Source and received optical power level > -50 dBm
Auto functions
2305/26, 2305/11, 2305/36, 2306/36, 2305/66, 2306/66
Auto-λ / Multi-λ
In Broadband Mode when connected to Broadband Port; when used with VIAVI Light Source and received optical power level > -50 dBm
Optical connectors
2305/26
2x SC/APC (1x OLT, 1x ONT)
Optical connectors
2305/11
2x SC/PC (1x OLT, 1x ONT), 1x UPP 2.5 mm
Optical connectors
2305/36, 2306/36, 2305/66, 2306/66
2x SC/APC (1x OLT, 1x ONT), 1x UPP 2.5 mm
NG-PON2 Power Meters
Type
2305/40
Composite DS/US
Type
2305/41
Selective DS / Composite US
Photo diode
2305/40, 2305/41
InGaAs
Spectral range
2305/40
Passband (1260…1360 nm, 1450…1500 nm, 1500…1620 nm, 1535…1565 nm, 1585…1625 nm)
Spectral range
2305/41
Passband (1260…1620 nm), TWDM (1598.89, 1598.04, 1597.18, 1596.34 nm)
Wavelength setting
2305/40
1310, 1490, 1535, 1550, 1600 nm
Wavelength setting
2305/41
1535, 1596.34, 1597.18, 1598.04, 1598.89 nm
Resolution
2305/40, 2305/41
0.01 dB, 0.001 µW
Measurement range for power level
2305/40
1310 nm: -40…+13 dBm; 1490 nm: -40…+13 dBm; 1535 nm: -40…+13 dBm; 1550 nm: -40…+26 dBm; 1600 nm: -40…+26 dBm
1310 nm Burst Mode: -35…+13 dBm
Measurement range for power level
2305/41
-40…+13 dBm
Burst Mode: -35…+13 dBm
Maximum power level
2305/40
1310 nm: +17 dBm; 1490 nm: +15 dBm; 1535 nm: +17 dBm; 1550 nm: +27 dBm; 1600 nm: +27 dBm
Maximum power level
2305/41
+17 dBm
Measurement uncertainty
2305/40, 2305/41
± 0.5 dB
Under reference conditions: 0 dBm (CW), nominal wavelength, 23°C ± 3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9µm core, 8° APC), when used with SC/APC connectors
ORL
2305/40, 2305/41
> 60 dB
Pass-through insertion loss
2305/40, 2305/41
< 1.5 dB
Number of calibrated wavelengths
2305/40
4 (1310, 1490, 1550, 1625 nm)
Number of calibrated wavelengths
2305/41
5 (1535, 1596.34, 1597.18, 1598.04, 1598.89 nm)
Optical connectors
2305/40, 2305/41
2x SC/APC (1x OLT, 1x ONT)
Display and Inspection
Display High contrast 3.5” color LCD touch screen (4:3 ration)
Typical at 25 °C
Fiber inspection Via external P-5000i or via patch cord microscope (P-variants)
Storage and Interface
Data storage 10,000 results
Data download capability Via USB interface
The product page states results are downloadable through USB or Ethernet interfaces
Remote control capability Via USB or Ethernet
Electrical interfaces 2x USB-A, 1x micro-USB, 1x Ethernet
Wireless interfaces WiFi or Bluetooth
Power
Dry batteries 8x Mignon (AA) Alkaline 1.5 V
Battery pack 1x Li-ion pack 3.7 V
AC operation Via Universal Power Adapter
Operating time 12 hrs. (OLP) with the dry batteries
Environmental
EMI/ESD CE compliant
Recommended calibration interval 3 years
Operating temperature -10 to +55°C (14 to 122°F)
Storage temperature -20 to +70°C (-4 to 158°F)
Physical
Dimensions (H x W x D)
OLP-87
208 x 112 x 64 mm (8.2 x 4.4 x 2.5 in)
Stand alone
Dimensions (H x W x D)
OLP-87P
208 x 153 x 64 mm (8.2 x 6.0 x 2.5 in)
P-variants
Weight
OLP-87
750 g (1.6 lbs.)
Stand alone
Weight
OLP-87P
850 g (1.85 lbs.)
P-variants
Patch Cord Microscope (PCM) – P-variants
Live image
OLP-87P
320 x 240 x 8 Bit Gray, 10 fps
Typical at 25 °C
Light source
OLP-87P
Blue LED, 100,000+ hour life
Lighting technique
OLP-87P
Coaxial
Low-magnification field-of-view (FOV)
OLP-87P
Horizontal: 740 µm; Vertical: 550 µm
High-magnification field-of-view (FOV)
OLP-87P
Horizontal: 370 µm; Vertical: 275 µm
Ordering Versions
2305/11
2305/11
OLP-87 - Selective PON Power Meter 1310/1490/1550 nm SC mounted FC enclosed
2305/26
2305/26
OLP-87 - Selective PON Power Meter 1310/1490 nm SC mounted FC enclosed
2305/36
2305/36
OLP-87 - Selective PON Power Meter 1310/1490/1550 nm SC/APC mounted FC enclosed
2306/36
2306/36
OLP-87P - Selective PON Power Meter 1310/1490/1550 nm SC/APC mounted FC enclosed and PCM
2305/66
2305/66
OLP-87 - Selective PON Power Meter 1270/1310/1490/1550/1577 nm SC mounted FC enclosed
2306/66
2306/66
OLP-87P - Selective PON Power Meter 1270/1310/1490/1550/1577 nm SC mounted FC enclosed and PCM
2305/40
2305/40
OLP-87 - NG-PON2 Power Meter 1310/1490/1535/1550/1600 nm SC mounted
2305/41
2305/41
OLP-87 - Selective NG-PON2 Power Meter SC mounted

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Service activation and troubleshooting
  • Simultaneous power measurement of upstream and downstream wavelengths on live PON networks
  • B-PON, E-PON, G-PON and XG-PON/10G-EPON network testing
  • NG-PON2 network testing
  • Network activation and testing in 5G deployments
  • FTTx/FTTH installation

Included

  • Instrument
  • Soft shoulder case
  • Hands-free carrier
  • Quick start guide and safety instructions
  • Alkaline batteries
  • One-click cleaner (version 2305/41 only)
  • Battery pack and power supply instead of alkaline batteries (version 2305/41 only)

Options & Accessories

Option Description
2305/94.01 Broadband SW option for OLP-87 — For versions 2305/11, 2305/36, 2306/36, 2305/66, 2306/66
2327/90.01 WiFi adapter spare
2327/90.02 Bluetooth adapter spare
2305/90.03 Calibration Report OLP-87/-88
2306/90.01 Calibration Report OLP-87P
2155/00.06 Switchable Optical Adapter SC/PC
2155/00.26 Switchable Optical Adapter SC/APC
2155/00.05 Switchable Optical Adapter FC/PC FC/APC
2155/00.07 Switchable optical adapter LC/PC LC/APC
2155/00.27 Switchable optical adapter LC/APC
2155/00.32 Switchable Optical Adapter ST/PC
VPP-UPP25 UPP 2.5 mm for Power Meters
VPP-UPP12 UPP 1.25 mm for Power Meters
2229/90.01 2x Alkaline batteries Mignon AA-Size LR6 — Four of this item are required for one SmartClass Fiber instrument, i.e. a total of 8 batteries
2305/90.02 Rechargeable Battery Pack
2305/90.04 Rechargeable Battery Pack with Power Supply
2305/90.01 Power Supply
FITP-UC4 Carrier For Displays Without PCM
FITP-UC4P Carrier For Displays With PCM (for P-variant)
2128/03 Soft Shoulder Case for 1 instrument
2128/04 Soft Shoulder Case for up to 4 instruments
FBP-SD101 P5000i digital analysis microscope with 4 tips

Documents & Resources

SmartClass Fiber Family
datasheet · PDF
SmartClass Fiber OLP-87 PON Power Meter - B/G/NG-PON2 Composite Power Version
brochure · PDF
SmartClass Fiber OLP-87 PON Power Meter - NG-PON2 Wavelength Selective Version
brochure · PDF
SmartClass Fiber OLP-87/87P PON Power Meter and Microscope
brochure · PDF
Quick Card: SmartClass Fiber OLP-87 PON Meter - Measuring FTTx/PON Power Levels
manual · PDF
SmartClass Fiber OLP-87 - Measuring NG-PON2 Power Levels
manual · PDF
P5000i Fiber Microscope - PON Fiber Inspection on the OLP-87
manual · PDF
The Perils of Using a Broadband Power Meter in a Multi-Service PON World
app note
SmartClass Fiber Software
software
Quick Tech Tip: Testing PON in Deep Fiber Applications
manual · PDF
OLP-87 for NG-PON2 - Lightwave Innovation Award interview with Wolfgang Moench
other
FTTH/PON - Efficient Deployment of FTTH/PON Networks
other
Understanding Passive Optical Network (PON) Testing
brochure
Fiber Inspection Tips and Adapters
brochure · PDF
Test and Monitoring Solutions for Fiber to the Home (FTTH)
brochure · PDF
PON Basics
other
Serving the Mobile Transport with NG-PON Technologies
other
Challenges in Next-Gen PON Deployment
app note · PDF
Fiber in 5G Networks
app note
Reference Guide to Fiber Optic Testing: Volume 1
app note
Reference Guide to Fiber Optic Testing: Volume 2
app note
SmartReporter Software
software
VIAVI Care Support Plans
other · PDF
Inspect Before You Connect Video Series
other
Test Guide to DAA Planning Deployment & Maintenance
app note · PDF
Testing 5G: Tools and Techniques for Successful Implementation, Maintenance and Monetization
app note