SmartClass Fiber OLP-87 PON Power Meter for B/E/G-PON, XG(S)-PON, 10G-EPON and NG-PON2
Wavelength-selective PON power meter that measures all upstream and downstream wavelengths on live B/E/G-PON, XG(S)-PON, 10G-EPON and NG-PON2 networks.
- Photo diode
- InGaAs
- Spectral range
- Passband (1260…1625 nm)
- Spectral range
- Passband (1260…1360 nm, 1480…1500 nm, 1535…1565 nm)
- Spectral range
- Passband (1260…1280 nm, 1290…1330 nm, 1480…1500 nm, 1535…1565 nm, 1573…1583 nm)
Overview
The VIAVI SmartClass Fiber OLP-87 is an FTTx/PON power meter used for activating and troubleshooting B-PON, E-PON and G-PON networks, next-generation 10G PON networks such as XG-PON and 10G-EPON, and higher-capacity NG-PON2 networks. It combines a wavelength-selective power meter with pass/fail fiber inspection analysis in one portable instrument.
In through mode, the OLP-87 is connected between the OLT and ONT sides of the link and measures the individual downstream and upstream wavelengths at the same time, including burst-mode upstream signals. This lets technicians verify the power level of each service separately where several PON technologies share the same fiber, for example G-PON alongside XGS-PON or E-PON alongside 10G-EPON.
Why a wavelength-selective meter
A broadband power meter sums every wavelength present at its input, so on a multi-service PON it reports an inaccurate, typically high, reading. That can lead to unnecessary attenuation and to ONTs that fail to activate or run with marginal power. A selective PON power meter isolates each wavelength and shows which service is present, which also determines the type of CPE (ONT/ONU) to install.
Inspection and reporting
Automated pass/fail fiber end-face inspection is available with the optional P5000i microscope, or with the integrated patch cord microscope on the OLP-87P variants. Measurement results are stored on the instrument and can be downloaded to generate certification reports that document work quality against industry or customer specifications. A hands-free carrier is supplied for use inside homes or on poles.
Key Features
- Through-mode measurement and display of voice, data and RF video signals at 1490/1550/1577 nm downstream and 1270/1310 nm upstream for B/E/G/XG(S)/10G PON
- Individual wavelength-selective through-mode power measurement of multiple NG-PON2 downstream and upstream channels
- Burst mode measurement for 1270 nm, 1310 nm and 1535 nm upstream signals
- High-performance broadband power meter option
- Storage of up to 10,000 measurement results, downloadable via USB or Ethernet
- Automated pass/fail fiber inspection analysis with optional P5000i microscope
- Integrated patch cord microscope version available (OLP-87P)
- Certification report generation
- Hands-free carrier for use inside homes or on telephone poles
- Supports co-existence of PON services, e.g. XG(S)-PON and/or NG-PON2 on existing G-PON networks
Specifications
|
Photo diode
2305/26, 2305/11, 2305/36, 2306/36, 2305/66, 2306/66
|
InGaAs |
|---|---|
|
Spectral range
2305/26
|
Passband (1260…1625 nm) |
|
Spectral range
2305/11, 2305/36, 2306/36
|
Passband (1260…1360 nm, 1480…1500 nm, 1535…1565 nm) |
|
Spectral range
2305/66, 2306/66
|
Passband (1260…1280 nm, 1290…1330 nm, 1480…1500 nm, 1535…1565 nm, 1573…1583 nm) |
|
Wavelength setting
2305/26
|
1310, 1490 nm |
|
Wavelength setting
2305/11, 2305/36, 2306/36
|
1310, 1490, 1550 nm; Broadband: 1260…1625 nm, step size 1 nm |
|
Wavelength setting
2305/66, 2306/66
|
1270, 1310, 1490, 1550, 1577 nm; Broadband: 1260…1625 nm, step size 1 nm |
|
Resolution
2305/26, 2305/11, 2305/36, 2306/36, 2305/66, 2306/66
|
0.01 dB, 0.001 µW |
|
Measurement range for power level
2305/26
|
1310 nm: -40…+13 dBm; 1490 nm: -50…+13 dBm
1310 nm Burst Mode: -35…+13 dBm
|
|
Measurement range for power level
2305/11, 2305/36, 2306/36
|
1310 nm: -40…+13 dBm; 1490 nm: -50…+13 dBm; 1550 nm: -50…+26 dBm; Broadband: -50…+13 dBm
1310 nm Burst Mode: -35…+13 dBm. Broadband in Broadband Mode when connected to Broadband Port (activated SW option required)
|
|
Measurement range for power level
2305/66, 2306/66
|
1270 nm: -40…+13 dBm; 1310 nm: -40…+13 dBm; 1490 nm: -50…+13 dBm; 1550 nm: -50…+26 dBm; 1577 nm: -50…+13 dBm; Broadband: -50…+13 dBm
1270/1310 nm Burst Mode: -35…+13 dBm. Broadband in Broadband Mode when connected to Broadband Port (activated SW option required). Only the present US wavelength is displayed and the other one as “LOW”
|
|
Maximum power level
2305/26
|
1310 nm: +17 dBm; 1490 nm: +15 dBm |
|
Maximum power level
2305/11, 2305/36, 2306/36
|
1310 nm: +17 dBm; 1490 nm: +15 dBm; 1550 nm: +27 dBm; Broadband: +15 dBm
Broadband in Broadband Mode when connected to Broadband Port (activated SW option required)
|
|
Maximum power level
2305/66, 2306/66
|
1270 nm: +17 dBm; 1310 nm: +17 dBm; 1490 nm: +15 dBm; 1550 nm: +27 dBm; 1577 nm: +15 dBm; Broadband: +15 dBm
Broadband in Broadband Mode when connected to Broadband Port (activated SW option required)
|
|
Measurement uncertainty
2305/26
|
1310 nm: ± 0.5 dB; 1490 nm: ± 0.5 dB
Under reference conditions: -7 dBm (CW), nominal wavelength, 23°C ± 3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9 µm core, 8° APC), when used with SC/APC connectors
|
|
Measurement uncertainty
2305/11, 2305/36, 2306/36
|
1310 nm: ± 0.5 dB; 1490 nm: ± 0.5 dB; 1550 nm: ± 0.5 dB; Broadband: ± 0.2 dB
Under reference conditions: -7 dBm (CW), nominal wavelength, 23°C ± 3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9 µm core, 8° APC), when used with SC/APC connectors
|
|
Measurement uncertainty
2305/66, 2306/66
|
1270 nm: ± 0.5 dB; 1310 nm: ± 0.5 dB; 1490 nm: ± 0.5 dB; 1550 nm: ± 0.5 dB; 1577 nm: ± 0.5 dB; Broadband: ± 0.2 dB
Under reference conditions: -7 dBm (CW), nominal wavelength, 23°C ± 3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9 µm core, 8° APC), when used with SC/APC connectors
|
|
ORL
2305/26, 2305/36, 2306/36, 2305/66, 2306/66
|
> 60 dB |
|
ORL
2305/11
|
> 40 dB |
|
Pass-through insertion loss
2305/26, 2305/11, 2305/36, 2306/36, 2305/66, 2306/66
|
< 1.5 dB |
|
Number of calibrated wavelengths
2305/26, 2305/11, 2305/36, 2306/36, 2305/66, 2306/66
|
4 (1310, 1490, 1550, 1625 nm) |
|
Tone detection
2305/26, 2305/11, 2305/36, 2306/36, 2305/66, 2306/66
|
CW, 270 Hz, 1 kHz, 2 kHz
In Broadband Mode when connected to Broadband Port; when used with VIAVI Light Source and received optical power level > -50 dBm
|
|
Auto functions
2305/26, 2305/11, 2305/36, 2306/36, 2305/66, 2306/66
|
Auto-λ / Multi-λ
In Broadband Mode when connected to Broadband Port; when used with VIAVI Light Source and received optical power level > -50 dBm
|
|
Optical connectors
2305/26
|
2x SC/APC (1x OLT, 1x ONT) |
|
Optical connectors
2305/11
|
2x SC/PC (1x OLT, 1x ONT), 1x UPP 2.5 mm |
|
Optical connectors
2305/36, 2306/36, 2305/66, 2306/66
|
2x SC/APC (1x OLT, 1x ONT), 1x UPP 2.5 mm |
|
Type
2305/40
|
Composite DS/US |
|---|---|
|
Type
2305/41
|
Selective DS / Composite US |
|
Photo diode
2305/40, 2305/41
|
InGaAs |
|
Spectral range
2305/40
|
Passband (1260…1360 nm, 1450…1500 nm, 1500…1620 nm, 1535…1565 nm, 1585…1625 nm) |
|
Spectral range
2305/41
|
Passband (1260…1620 nm), TWDM (1598.89, 1598.04, 1597.18, 1596.34 nm) |
|
Wavelength setting
2305/40
|
1310, 1490, 1535, 1550, 1600 nm |
|
Wavelength setting
2305/41
|
1535, 1596.34, 1597.18, 1598.04, 1598.89 nm |
|
Resolution
2305/40, 2305/41
|
0.01 dB, 0.001 µW |
|
Measurement range for power level
2305/40
|
1310 nm: -40…+13 dBm; 1490 nm: -40…+13 dBm; 1535 nm: -40…+13 dBm; 1550 nm: -40…+26 dBm; 1600 nm: -40…+26 dBm
1310 nm Burst Mode: -35…+13 dBm
|
|
Measurement range for power level
2305/41
|
-40…+13 dBm
Burst Mode: -35…+13 dBm
|
|
Maximum power level
2305/40
|
1310 nm: +17 dBm; 1490 nm: +15 dBm; 1535 nm: +17 dBm; 1550 nm: +27 dBm; 1600 nm: +27 dBm |
|
Maximum power level
2305/41
|
+17 dBm |
|
Measurement uncertainty
2305/40, 2305/41
|
± 0.5 dB
Under reference conditions: 0 dBm (CW), nominal wavelength, 23°C ± 3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9µm core, 8° APC), when used with SC/APC connectors
|
|
ORL
2305/40, 2305/41
|
> 60 dB |
|
Pass-through insertion loss
2305/40, 2305/41
|
< 1.5 dB |
|
Number of calibrated wavelengths
2305/40
|
4 (1310, 1490, 1550, 1625 nm) |
|
Number of calibrated wavelengths
2305/41
|
5 (1535, 1596.34, 1597.18, 1598.04, 1598.89 nm) |
|
Optical connectors
2305/40, 2305/41
|
2x SC/APC (1x OLT, 1x ONT) |
| Display |
High contrast 3.5” color LCD touch screen (4:3 ration)
Typical at 25 °C
|
|---|---|
| Fiber inspection | Via external P-5000i or via patch cord microscope (P-variants) |
| Data storage | 10,000 results |
|---|---|
| Data download capability |
Via USB interface
The product page states results are downloadable through USB or Ethernet interfaces
|
| Remote control capability | Via USB or Ethernet |
| Electrical interfaces | 2x USB-A, 1x micro-USB, 1x Ethernet |
| Wireless interfaces | WiFi or Bluetooth |
| Dry batteries | 8x Mignon (AA) Alkaline 1.5 V |
|---|---|
| Battery pack | 1x Li-ion pack 3.7 V |
| AC operation | Via Universal Power Adapter |
| Operating time | 12 hrs. (OLP) with the dry batteries |
| EMI/ESD | CE compliant |
|---|---|
| Recommended calibration interval | 3 years |
| Operating temperature | -10 to +55°C (14 to 122°F) |
| Storage temperature | -20 to +70°C (-4 to 158°F) |
|
Dimensions (H x W x D)
OLP-87
|
208 x 112 x 64 mm (8.2 x 4.4 x 2.5 in)
Stand alone
|
|---|---|
|
Dimensions (H x W x D)
OLP-87P
|
208 x 153 x 64 mm (8.2 x 6.0 x 2.5 in)
P-variants
|
|
Weight
OLP-87
|
750 g (1.6 lbs.)
Stand alone
|
|
Weight
OLP-87P
|
850 g (1.85 lbs.)
P-variants
|
|
Live image
OLP-87P
|
320 x 240 x 8 Bit Gray, 10 fps
Typical at 25 °C
|
|---|---|
|
Light source
OLP-87P
|
Blue LED, 100,000+ hour life |
|
Lighting technique
OLP-87P
|
Coaxial |
|
Low-magnification field-of-view (FOV)
OLP-87P
|
Horizontal: 740 µm; Vertical: 550 µm |
|
High-magnification field-of-view (FOV)
OLP-87P
|
Horizontal: 370 µm; Vertical: 275 µm |
|
2305/11
2305/11
|
OLP-87 - Selective PON Power Meter 1310/1490/1550 nm SC mounted FC enclosed |
|---|---|
|
2305/26
2305/26
|
OLP-87 - Selective PON Power Meter 1310/1490 nm SC mounted FC enclosed |
|
2305/36
2305/36
|
OLP-87 - Selective PON Power Meter 1310/1490/1550 nm SC/APC mounted FC enclosed |
|
2306/36
2306/36
|
OLP-87P - Selective PON Power Meter 1310/1490/1550 nm SC/APC mounted FC enclosed and PCM |
|
2305/66
2305/66
|
OLP-87 - Selective PON Power Meter 1270/1310/1490/1550/1577 nm SC mounted FC enclosed |
|
2306/66
2306/66
|
OLP-87P - Selective PON Power Meter 1270/1310/1490/1550/1577 nm SC mounted FC enclosed and PCM |
|
2305/40
2305/40
|
OLP-87 - NG-PON2 Power Meter 1310/1490/1535/1550/1600 nm SC mounted |
|
2305/41
2305/41
|
OLP-87 - Selective NG-PON2 Power Meter SC mounted |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Service activation and troubleshooting
- Simultaneous power measurement of upstream and downstream wavelengths on live PON networks
- B-PON, E-PON, G-PON and XG-PON/10G-EPON network testing
- NG-PON2 network testing
- Network activation and testing in 5G deployments
- FTTx/FTTH installation
Included
- Instrument
- Soft shoulder case
- Hands-free carrier
- Quick start guide and safety instructions
- Alkaline batteries
- One-click cleaner (version 2305/41 only)
- Battery pack and power supply instead of alkaline batteries (version 2305/41 only)
Options & Accessories
| Option | Description |
|---|---|
| 2305/94.01 | Broadband SW option for OLP-87 — For versions 2305/11, 2305/36, 2306/36, 2305/66, 2306/66 |
| 2327/90.01 | WiFi adapter spare |
| 2327/90.02 | Bluetooth adapter spare |
| 2305/90.03 | Calibration Report OLP-87/-88 |
| 2306/90.01 | Calibration Report OLP-87P |
| 2155/00.06 | Switchable Optical Adapter SC/PC |
| 2155/00.26 | Switchable Optical Adapter SC/APC |
| 2155/00.05 | Switchable Optical Adapter FC/PC FC/APC |
| 2155/00.07 | Switchable optical adapter LC/PC LC/APC |
| 2155/00.27 | Switchable optical adapter LC/APC |
| 2155/00.32 | Switchable Optical Adapter ST/PC |
| VPP-UPP25 | UPP 2.5 mm for Power Meters |
| VPP-UPP12 | UPP 1.25 mm for Power Meters |
| 2229/90.01 | 2x Alkaline batteries Mignon AA-Size LR6 — Four of this item are required for one SmartClass Fiber instrument, i.e. a total of 8 batteries |
| 2305/90.02 | Rechargeable Battery Pack |
| 2305/90.04 | Rechargeable Battery Pack with Power Supply |
| 2305/90.01 | Power Supply |
| FITP-UC4 | Carrier For Displays Without PCM |
| FITP-UC4P | Carrier For Displays With PCM (for P-variant) |
| 2128/03 | Soft Shoulder Case for 1 instrument |
| 2128/04 | Soft Shoulder Case for up to 4 instruments |
| FBP-SD101 | P5000i digital analysis microscope with 4 tips |