VIAVI SmartPocket V2 OMK-38V2 High Power SM Optical Test Kit
SmartPocket V2 high power SM test kit with OLS-35V2 source and OLP-38V2 power meter measuring up to +26 dBm for CATV and DWDM.
- Type
- Class 1 Laser Product (IEC 60825-1:2007)
- Short Term Stability
- ±0.02 dB within 15 min
- Long Term Stability
- ±0.05 dB within 8 hrs.
- Light Source Model
- OLS-35V2
Overview
The VIAVI SmartPocket V2 OMK-3xV2 optical test kits are pocket-sized, rugged instrument sets for installing and maintaining single mode (SM) and multimode (MM) fiber optic networks. Each kit combines an optical power meter with a dual- or quad-wavelength optical light source for power level measurements, insertion loss measurements and continuity checks.
The OMK-38V2 kit uses SmartPocket V2 instruments, which are designed for outdoor use and low power consumption. The instruments switch on instantly without boot time. A backlit graphical display with context-sensitive softkeys, a no-setup OptiChek measurement mode, Auto-λ and Multi-λ modes and pass/fail indication simplify routine testing.
Data handling and power
The power meter stores more than 1,000 test results, which can be transferred to a PC over USB-C or uploaded via Bluetooth Low Energy to the VIAVI Mobile Tech application and StrataSync. The instruments can be powered by alkaline AA batteries, NiMH AA rechargeable batteries, an AC power adapter or power over USB. The recommended calibration interval is three years.
Key Features
- Broadband power meter with Dual SM or Quad SM/MM sources
- Fiber tracing by detecting optical light source tones
- Storage for over 1000 test results and PC download capability
- Bluetooth Low Energy connectivity to the VIAVI Mobile Tech App
- Automatic upload of results via the VIAVI Mobile Tech application
- 4-way powering: alkaline AA, NiMH AA rechargeable, AC power adapter and power over USB
- 3-year recalibration period
- Instant on with no boot time
- Low power consumption for extended continuous use
- Designed for outdoor environments
- High-visibility backlit graphical display with context-sensitive softkeys
- No-setup OptiChek measurement mode
- Fast Auto-λ and Multi-λ mode (~1 sec)
- Clear pass/fail information
Specifications
| Type | Class 1 Laser Product (IEC 60825-1:2007) |
|---|---|
| Short Term Stability | ±0.02 dB within 15 min |
| Long Term Stability |
±0.05 dB within 8 hrs.
requires a warm-up time of 20 minutes and applies to a constant temperature
|
| Light Source Model | OLS-35V2 |
| Wavelengths | 1310, 1550 nm |
| Output Power (CW) | Typ. -3 dBm |
| FWHM Spectral Width | < 5 nm |
| Optical Connectors | 1x SC/PC |
| Spectral Range | Broadband (800...1650 nm) |
|---|---|
| Wavelength Setting | 800…1650 nm, step size 1 nm |
| Resolution | 0.01 dB, 0.001 µW |
| Measurement Uncertainty (OptiChek Mode) |
±0.8 dB / ±5 % (intrinsic)
under reference conditions: -11 dBm (CW), 1310 nm ±1 nm, 23 °C ±3 K, 45 to 75 % relative humidity, SM test fiber, SC/PC connectors
|
| Linearity |
±0.06 dB
under the following conditions: -50…+ 5 dBm, 0…+45 °C
|
| Number of Calibrated Wavelengths | 8 (850, 980, 1310, 1490, 1550, 1577, 1625, 1650 nm) |
| Tone Detection |
CW, 270 Hz, 330 Hz, 1 kHz, 2 kHz
received optical power level ≥ -50 dBm; when used with VIAVI Light Source
|
| Auto functions |
Auto-λ / Multi-λ
when used with VIAVI Light Source and received optical power level > -50 dBm
|
| Optical Connectors | 1x UPP 2.5 mm |
| Power Meter Model | OLP-38V2 |
| Photo Diode | InGaAs (coated) |
| Power Range | -50 to +26 dBm |
| Max. Power Level (before damage) | +27 dBm |
| Measurement Uncertainty (Expert Mode) |
±0.5 dB
for OLP-38V2, under reference conditions: -11 dBm (CW), 1310 nm ±1 nm, 23 °C ±3 K, SM test fiber, SC/PC connectors
|
| Data Storage | 1,000 Results |
|---|---|
| Data Download Capability | USB-C for PC/Laptop Transfer or BLE to StrataSync via MTA |
| Batteries | 2x Mignon (AA) Size |
|---|---|
| AC Operation | Via USB-C and Universal Power Adapter (Pmax.: 2.5 W) |
| Operating Time (Light Source) |
25 hrs.
continuous operation with dry batteries
|
| Operating Time (Power Meter) |
45 hrs.
continuous operation with dry batteries
|
| EMI/ESD | CE Compliant |
|---|---|
| Electromagnetic Compatibility | EN 61326-1:2013 |
| Device Safety | EN 61010-1:2010/A1:2019 |
| Recommended Calibration Interval | 3 Years |
| Operating Temperature | -10 to +55 °C (14 to 131 °F) |
| Storage Temperature | -20 to +70 °C (-4 to +158 °F) |
| Max. Altitude | 2,000 m (6,500 ft) |
| Pollution Degree | 2 |
| Ingress Protection | IP44 |
| Humidity |
15 to 85 % (Relative) up to +31 °C; 20 g/m3 (Absolute) > +31 °C
occasional condensation is tolerable as a limit condition
|
| Dimensions (H x W x D) |
30 x 80 x 150 mm (1.2 x 3.1 x 5.9 in)
per instrument
|
|---|---|
| Weight (w/o Batteries) |
200 g (0.45 lb)
per instrument
|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Optical power level measurement on SM and MM networks
- Link insertion loss measurement
- Continuity checks
- Enterprise/LAN network build and maintenance
- Access and Metro (LAN/WAN) network build and maintenance
- FTTx (Home/Antenna) network build and maintenance
- Telecom, CATV and military power level tests
- CATV high power level testing
- Amplified DWDM testing up to +26 dBm
Included
- Instruments (OLS light source and OLP power meter)
- Switchable adapter
- Soft bag for 2 units
- Neck straps
- Quick start guide
- Safety instructions
- Alkaline batteries
- USB cable
Options & Accessories
| Option | Description |
|---|---|
| 2302/90.02 | Calibration Report Power Meters (OLP-35V2/-35SC/-38V) and OLP-37XV2 |
| 2303/90.01 | Calibration Report Light Sources (OLS-34V2/-35V2/-36V2/-38V2) |
| VPP-UPP12 | UPP 1.25 mm for Power Meters (not for OLP-35SC) |
| VPP-UPP25 | UPP 2.5 mm for Power Meters (not for OLP-35SC) |
| 2155/00.05 | Switchable Adapter FC/PC FC/APC for Light Sources and OLP-37XV2 |
| 2155/00.06 | Switchable Adapter SC/PC for Spare Light Sources |
| 2155/00.07 | Switchable Adapter LC/PC LC/APC for Light Sources and OLP-37XV2 |
| 2155/00.32 | Switchable Adapter ST/PC for Light Sources |
| 2229/90.21 | OCK-10 Cleaning Kit complete |
| 22122619 | USB 2.0 Type A to Type C Cable |
| 2229/90.01 | 2x Alkaline Batteries Mignon AA-Size LR6 |
| 2237/90.02 | 2x Rechargeable batteries AA; NiMH; 1.2V; 2.6 / 2.7Ah |
| 2302/90.01 | Universal AC Power Adapter |