VIAVI SmartPocket V2 OMK-36V2 kit with OLP-35V2 power meter and OLS-36V2 quad light source
VIAVI / Series · Essential Fiber Optic Testers

SmartPocket V2 OMK-35V2/-36V2/-38V2 Optical Test Kits (Power Meter and Light Source)

Pocket-sized kits that pair an optical power meter with a dual or quad-wavelength light source for SM and MM fiber loss testing.

Light Source Wavelengths
1310, 1550 nm
Light Source Wavelengths
850, 1300, 1310, 1550 nm
Light Source Wavelengths
1310, 1550 nm
Light Source Output Power (CW)
Typ. -3 dBm
View Models Datasheet

Overview

The VIAVI SmartPocket V2 OMK-3xV2 optical test kits are pocket-sized, rugged instruments for installing and maintaining single mode (SM) and multimode (MM) fiber optic networks. Each kit combines an optical power meter with a dual or quad-wavelength optical light source for power level measurements, insertion loss measurements and continuity checks.

Kit configurations

The OMK-35V2 is a single mode kit with an OLS-35V2 light source and an OLP-35V2 power meter, intended for telecom applications. The OMK-38V2 is a high-power single mode kit with an OLS-35V2 light source and an OLP-38V2 power meter for CATV and amplified DWDM applications up to +26 dBm. The OMK-36V2 is a quad SM/MM kit with an OLS-36V2 light source and an OLP-35V2 power meter for enterprise LAN/WAN applications.

Operation

The instruments start instantly with no boot time and use a backlit graphical display with context-sensitive softkeys. A no-setup OptiChek measurement mode, automatic and multi-wavelength detection, and pass/fail indication simplify testing. The power meter detects light source tones for fiber tracing.

Data and power

The meters store over 1000 test results, which can be downloaded to a PC or uploaded via Bluetooth Low Energy to the VIAVI Mobile Tech application. The units can be powered by alkaline AA cells, NiMH AA rechargeable cells, an AC power adapter or USB, and have a 3-year recalibration period.

Models in this series

Model Description
OMK-35V2
VIAVI SmartPocket V2 OMK-35V2 Single Mode Optical Test Kit
SmartPocket V2 single mode loss test kit with OLS-35V2 1310/1550 nm source and OLP-35V2 broadband power meter for telecom networks.
Details →
OMK-36V2
VIAVI SmartPocket V2 OMK-36V2 SM/MM Quad Optical Test Kit
SmartPocket V2 SM+MM loss test kit with OLS-36V2 quad-wavelength source and OLP-35V2 power meter for enterprise LAN/WAN fiber.
Details →
OMK-38V2
VIAVI SmartPocket V2 OMK-38V2 High Power SM Optical Test Kit
SmartPocket V2 high power SM test kit with OLS-35V2 source and OLP-38V2 power meter measuring up to +26 dBm for CATV and DWDM.
Details →

Key Features

  • Broadband power meter with dual SM or quad SM/MM light sources
  • Fiber tracing by detecting optical light source tones
  • Storage for over 1000 test results with PC download capability
  • Bluetooth Low Energy connectivity to the VIAVI Mobile Tech App
  • 4-way powering: alkaline AA, NiMH AA rechargeable, AC power adapter and power over USB
  • 3-year recalibration period
  • Instant on with no boot time
  • Low power consumption for extended continuous use
  • Designed for outdoor environments
  • High-visibility backlit graphical display with context-sensitive softkeys
  • No-setup OptiChek measurement mode
  • Fast Auto-λ and Multi-λ mode (~1 sec)
  • Clear pass/fail information
  • Automatic upload of results via VIAVI Mobile Tech application

Specifications

Kit Overview
Light Source Wavelengths
OMK-35V2
1310, 1550 nm
Light Source Wavelengths
OMK-36V2
850, 1300, 1310, 1550 nm
Light Source Wavelengths
OMK-38V2
1310, 1550 nm
Light Source Output Power (CW)
OMK-35V2
Typ. -3 dBm
Light Source Output Power (CW)
OMK-36V2
Typ. -20 dBm / -3 dBm
Light Source Output Power (CW)
OMK-38V2
Typ. -3 dBm
Optical Power Meter Power Range
OMK-35V2
-65 to +10 dBm
Optical Power Meter Power Range
OMK-36V2
-65 to +10 dBm
Optical Power Meter Power Range
OMK-38V2
-50 to +26 dBm
Light Sources
Type Class 1 Laser Product (IEC 60825-1:2007)
FWHM Spectral Width
OLS-35V2
< 5 nm
FWHM Spectral Width
OLS-36V2
< 170 nm (850, 1300 nm) / < 5 nm (1310, 1550 nm)
Output Level (CW)
OLS-35V2
Typ. -3 dBm
Output Level (CW)
OLS-36V2
Typ. -20 dBm (850, 1300 nm) / Typ. -3 dBm (1310, 1550 nm)
Short Term Stability ±0.02 dB
within 15 min
Long Term Stability ±0.05 dB
within 8 hrs.; requires a warm-up time of 20 minutes and applies to a constant temperature
Optical Connectors
OLS-35V2
1x SC/PC
Optical Connectors
OLS-36V2
2x SC/PC
Power Meters
Photo Diode
OLP-35V2
InGaAs
Photo Diode
OLP-38V2
InGaAs (coated)
Spectral Range
OLP-35V2, OLP-38V2
Broadband (800...1650 nm)
Wavelength Setting
OLP-35V2, OLP-38V2
800…1650 nm, step size 1 nm
Resolution 0.01 dB, 0.001 µW
Measurement Range for Power Level
OLP-35V2
-65…+10 dBm
Measurement Range for Power Level
OLP-38V2
-50…+26 dBm
Max. Power Level (before damage)
OLP-35V2
+16 dBm
Max. Power Level (before damage)
OLP-38V2
+27 dBm
Measurement Uncertainty
OLP-35V2, OLP-38V2
Expert Mode: ±0.2 dB / ±5 % (intrinsic); OptiChek Mode: ±0.8 dB / ±5 % (intrinsic)
under reference conditions: -11 dBm (CW), 1310 nm ±1 nm, 23 °C ±3 K, 45 to 75 % relative humidity, SM test fiber, SC/PC connectors; for OLP-38V2: Expert Mode: ±0.5 dB
Linearity
OLP-35V2, OLP-38V2
±0.06 dB
-50…+5 dBm, 0…+45 °C; for OLP-35V2 at 850 nm: ±0.15 dB
Number of Calibrated Wavelengths
OLP-35V2, OLP-38V2
8 (850, 980, 1310, 1490, 1550, 1577, 1625, 1650 nm)
Tone Detection
OLP-35V2, OLP-38V2
CW, 270 Hz, 330 Hz, 1 kHz, 2 kHz
received optical power level ≥ -50 dBm
Auto functions Auto-λ / Multi-λ
when used with VIAVI Light Source and received optical power level > -50 dBm
Optical Connectors
OLP-35V2, OLP-38V2
1x UPP 2.5 mm
Storage and Interface
Data Storage 1,000 Results
Data Download Capability USB-C for PC/Laptop Transfer or BLE to StrataSync via MTA
Power Supply
Batteries 2x Mignon (AA) Size
AC Operation Via USB-C and Universal Power Adapter (Pmax.: 2.5 W)
Operating Time
OLP-35V2, OLP-38V2
45 hrs.
continuous operation with dry batteries
Operating Time
OLS-35V2, OLS-36V2
25 hrs.
continuous operation with dry batteries
Safety and Environmental
EMI/ESD CE Compliant
Electromagnetic Compatibility EN 61326-1:2013
Device Safety EN 61010-1:2010/A1:2019
Recommended Calibration Interval 3 Years
Operating Temperature -10 to +55 °C (14 to 131 °F)
Storage Temperature -20 to +70 °C (-4 to +158 °F)
Max. Altitude 2,000 m (6,500 ft)
Pollution Degree 2
Ingress Protection IP44
Humidity 15 to 85 % (Relative) up to +31 °C; 20 g/m3 (Absolute) > +31 °C
occasional condensation is tolerable as a limit condition
Physical
Dimensions (H x W x D) 30 x 80 x 150 mm (1.2 x 3.1 x 5.9 in)
per instrument
Weight (w/o Batteries) 200 g (0.45 lb)
per instrument

Applications

  • Optical power level and link insertion loss measurement for SM and MM networks
  • Enterprise/LAN network build and maintenance
  • Access and metro (LAN/WAN) networks
  • FTTx (e.g. home/antenna)
  • Telecom testing
  • CATV testing
  • Amplified DWDM applications
  • Military applications
  • Standard and high-power level tests

Options & Accessories

Option Description
2302/90.02 Calibration Report Power Meters (OLP-35V2/-35SC/-38V) and OLP-37XV2
2303/90.01 Calibration Report Light Sources (OLS-34V2/-35V2/-36V2/-38V2)
VPP-UPP12 UPP 1.25 mm for Power Meters (not for OLP-35SC)
VPP-UPP25 UPP 2.5 mm for Power Meters (not for OLP-35SC)
2155/00.05 Switchable Adapter FC/PC FC/APC for Light Sources and OLP-37XV2
2155/00.06 Switchable Adapter SC/PC for Spare Light Sources
2155/00.07 Switchable Adapter LC/PC LC/APC for Light Sources and OLP-37XV2
2155/00.32 Switchable Adapter ST/PC for Light Sources
2229/90.21 OCK-10 Cleaning Kit complete
22122619 USB 2.0 Type A to Type C Cable
2229/90.01 2x Alkaline Batteries Mignon AA-Size LR6
2237/90.02 2x Rechargeable batteries AA; NiMH; 1.2V; 2.6 / 2.7Ah
2302/90.01 Universal AC Power Adapter

Documents & Resources