VIAVI SmartClass Fiber OLP-85 handheld optical power meter, front view
VIAVI / Series · Essential Fiber Optic Testers

SmartClass Fiber OLP-85/-85P Inspection-Ready Handheld Optical Power Meters

Handheld optical power meters that combine fiber inspection and power measurement, with a 100 dB dynamic range from 800 to 1700 nm.

Photo Diode
InGaAs (coated)
Spectral Range
Broadband (800…1700 nm)
Wavelength Setting
800…1700 nm, step size 1 nm
Resolution
0.01 dB, 0.001 µW
View Models Datasheet

Overview

The VIAVI SmartClass Fiber OLP-85 and OLP-85P combine pass/fail fiber inspection and optical power measurement (OPM) in one handheld instrument. Both models offer a 100 dB dynamic range and are intended for fiber-optic network power and loss test applications.

The meters keep their accuracy across the full measurement range, so they can be used where very low or very high optical power has to be measured. The measurement wavelength range is 800 to 1700 nm and can be set in 1 nm steps.

The OLP-85P adds an integrated patch cord microscope (PCM). Both models can also do automated pass/fail fiber inspection analysis with the optional P5000i microscope. The instruments run on batteries and have a compact, rugged, weather-proof housing with a 3.5-in color touch screen.

Connectivity and software

Fiber inspection and test results are stored on the instrument with a time stamp. Data transfer and remote control work over USB or Ethernet. When used with VIAVI light sources, the meters support auto-lambda and multi-lambda testing. SmartClass Fiber Software and SmartReporter Software are available for download.

Models in this series

Model Description
OLP-85
SmartClass Fiber OLP-85 Inspection-Ready Optical Power Meter
Handheld broadband optical power meter with 100 dB dynamic range, 800 to 1700 nm range and pass/fail inspection via the P5000i microscope.
Details →
OLP-85P
SmartClass Fiber OLP-85P Inspection-Ready Optical Power Meter with PCM
Handheld broadband optical power meter with 100 dB dynamic range, 800 to 1700 nm range and an integrated patch cord microscope (PCM).
Details →

Key Features

  • 800 to 1700 nm measurement wavelength range with 1 nm incremental setting
  • High accuracy over a 100 dB dynamic range
  • Battery-operated, field-portable design
  • 2.5 mm and optional 1.25 mm universal push-pull (UPP) adapter system compatible with all optical connector types
  • 3.5-in color touch screen with integrated stylus
  • Individual threshold settings for power and loss pass/fail analysis
  • Onboard storage of fiber inspection and test results with time stamp
  • Data transfer and remote control via USB or Ethernet interface
  • Auto-lambda and multi-lambda test functions in combination with VIAVI light sources
  • Automated pass/fail fiber inspection analysis with the optional P5000i microscope
  • Integrated patch cord microscope (PCM) on the OLP-85P
  • Compact, rugged, weather-proof design

Specifications

Power Meter
Photo Diode InGaAs (coated)
Spectral Range Broadband (800…1700 nm)
Wavelength Setting 800…1700 nm, step size 1 nm
Resolution 0.01 dB, 0.001 µW
Measurement Range for Power Level -75…+26 dBm
Max. Power Level +30 dBm
Measurement Uncertainty (intrinsic) ± 0.15 dB
Under reference conditions: -22 dBm (CW), 1310/1490/1550 nm ± 1 nm, 23°C ± 3 K, 45 to 75% RH, SM test fiber (9 µm core, 8° APC); at 850, 980 or 1625 nm: ± 0.25 dB (intrinsic)
Measurement Uncertainty 850, 980 nm: ± 0.35 dB; 1310, 1490, 1550 nm: ± 0.25 dB; 1625 nm: ± 0.35 dB
Per-wavelength values printed in the OLP-85/-85P column of the datasheet table
Linearity ± 0.06 dB
Under the following conditions: -50…+ 5 dBm, 0…+45°C
Number of Calibrated Wavelengths 6 (850, 980, 1310, 1490, 1550, 1625 nm)
Tone Detection CW, 270 Hz, 1 kHz, 2 kHz
Received optical power level ≥ -50 dBm; when used with VIAVI Light Source and received optical power level > -50 dBm
Auto Functions Auto-λ / Multi-λ
When used with VIAVI Light Source and received optical power level > -50 dBm
Optical Connectors configurable
General
Display High contrast 3.5” color LCD touch screen (4:3 ration)
Typical at 25 °C
Fiber inspection Via external P-5000i or via patch cord microscope (P-variants)
Storage and Interface
Data Storage 10,000 results
Data download capability Via USB interface
Remote control capability Via USB or Ethernet
Electrical interfaces 2x USB-A, 1x micro-USB, 1x Ethernet
Wireless interfaces WiFi or Bluetooth
Power
Dry batteries 8x Mignon (AA) Alkaline 1.5 V
Battery pack 1x Li-ion pack 3.7 V
AC operation Via Universal Power Adapter
Operating time 12 hrs. (OLP) with the dry batteries
Environmental
EMI/ESD CE compliant
Recommended calibration interval 3 years
Operating temperature -10 to +55°C (14 to 122°F)
Storage temperature -20 to +70°C (-4 to 158°F)
Physical
Dimensions (H x W x D)
OLP-85
208 x 112 x 64 mm (8.2 x 4.4 x 2.5 in)
Stand alone
Dimensions (H x W x D)
OLP-85P
208 x 153 x 64 mm (8.2 x 6.0 x 2.5 in)
P-variants
Weight
OLP-85
750 g (1.6 lbs.)
Stand alone
Weight
OLP-85P
850 g (1.85 lbs.)
P-variants
Patch Cord Microscope (PCM)
Live Image
OLP-85P
320 x 240 x 8 Bit Gray, 10 fps
Typical at 25 °C
Light Source
OLP-85P
Blue LED, 100,000+ hour life
Lighting Technique
OLP-85P
Coaxial
Low-Magnification Field-of-View (FOV)
OLP-85P
Horizontal: 740 µm; Vertical: 550 µm
High-Magnification Field-of-View (FOV)
OLP-85P
Horizontal: 370 µm; Vertical: 275 µm
Ordering Information
OLP-85 - Broadband Power Meter 100 dB dynamic range
OLP-85
2307/03
OLP-85P - Broadband Power Meter 100 dB dynamic range and PCM
OLP-85P
2308/03

Applications

  • Measurement of optical power (absolute and relative)
  • Measurement of optical insertion loss with a VIAVI OLS-3x or OLS-8x light source
  • Inspection of optical connectors (IBYC)
  • In-service loss testing

Options & Accessories

Option Description
2307/90.01 Calibration Report for OLP-85
2308/90.01 Calibration Report OLP-85P
2327/90.01 WiFi adapter spare
2327/90.02 Bluetooth adapter spare
VPP-UPP25 UPP 2.5 mm for Power Meters
VPP-UPP12 UPP 1.25 mm for Power Meters
2014/00.09 FC Type NTT.D3 (for OLP-85)
2014/00.17 DIN 47256 LSA -PC -APC (for OLP-85)
2014/00.21 ST Type (for OLP-85)
2014/00.24 SC/PC SC/APC (for OLP-85)
2014/00.26 E-2000 -PC -APC (for OLP-85)
2014/00.28 UPP for LC MU D 1.25 mm (for OLP-85)
2014/00.29 LC F-3000 -PC -APC (for OLP-85)
2014/00.31 UPP for DIN FC SC ST and MST D 2.5 mm (for OLP-85)
2229/90.01 2x Alkaline batteries Mignon AA-Size LR6 — Four of this item are required for one SmartClass Fiber instrument, i.e. a total of 8 batteries
2305/90.02 Rechargeable Battery Pack
2305/90.04 Rechargeable Battery Pack with Power Supply
2305/90.01 Power Supply
FITP-UC4 Carrier For Displays Without PCM
FITP-UC4P Carrier For Displays With PCM (for P-variant)
2128/03 Soft Shoulder Case for 1 instrument
2128/04 Soft Shoulder Case for up to 4 instruments
FBP-SD101 P5000i digital analysis microscope with 4 tips

Documents & Resources