SmartClass Fiber OLP-85/-85P Inspection-Ready Handheld Optical Power Meters
Handheld optical power meters that combine fiber inspection and power measurement, with a 100 dB dynamic range from 800 to 1700 nm.
- Photo Diode
- InGaAs (coated)
- Spectral Range
- Broadband (800…1700 nm)
- Wavelength Setting
- 800…1700 nm, step size 1 nm
- Resolution
- 0.01 dB, 0.001 µW
Overview
The VIAVI SmartClass Fiber OLP-85 and OLP-85P combine pass/fail fiber inspection and optical power measurement (OPM) in one handheld instrument. Both models offer a 100 dB dynamic range and are intended for fiber-optic network power and loss test applications.
The meters keep their accuracy across the full measurement range, so they can be used where very low or very high optical power has to be measured. The measurement wavelength range is 800 to 1700 nm and can be set in 1 nm steps.
The OLP-85P adds an integrated patch cord microscope (PCM). Both models can also do automated pass/fail fiber inspection analysis with the optional P5000i microscope. The instruments run on batteries and have a compact, rugged, weather-proof housing with a 3.5-in color touch screen.
Connectivity and software
Fiber inspection and test results are stored on the instrument with a time stamp. Data transfer and remote control work over USB or Ethernet. When used with VIAVI light sources, the meters support auto-lambda and multi-lambda testing. SmartClass Fiber Software and SmartReporter Software are available for download.
Models in this series
| Model | Description | |
|---|---|---|
| OLP-85 |
SmartClass Fiber OLP-85 Inspection-Ready Optical Power Meter
Handheld broadband optical power meter with 100 dB dynamic range, 800 to 1700 nm range and pass/fail inspection via the P5000i microscope. |
Details → |
| OLP-85P |
SmartClass Fiber OLP-85P Inspection-Ready Optical Power Meter with PCM
Handheld broadband optical power meter with 100 dB dynamic range, 800 to 1700 nm range and an integrated patch cord microscope (PCM). |
Details → |
Key Features
- 800 to 1700 nm measurement wavelength range with 1 nm incremental setting
- High accuracy over a 100 dB dynamic range
- Battery-operated, field-portable design
- 2.5 mm and optional 1.25 mm universal push-pull (UPP) adapter system compatible with all optical connector types
- 3.5-in color touch screen with integrated stylus
- Individual threshold settings for power and loss pass/fail analysis
- Onboard storage of fiber inspection and test results with time stamp
- Data transfer and remote control via USB or Ethernet interface
- Auto-lambda and multi-lambda test functions in combination with VIAVI light sources
- Automated pass/fail fiber inspection analysis with the optional P5000i microscope
- Integrated patch cord microscope (PCM) on the OLP-85P
- Compact, rugged, weather-proof design
Specifications
| Photo Diode | InGaAs (coated) |
|---|---|
| Spectral Range | Broadband (800…1700 nm) |
| Wavelength Setting | 800…1700 nm, step size 1 nm |
| Resolution | 0.01 dB, 0.001 µW |
| Measurement Range for Power Level | -75…+26 dBm |
| Max. Power Level | +30 dBm |
| Measurement Uncertainty (intrinsic) |
± 0.15 dB
Under reference conditions: -22 dBm (CW), 1310/1490/1550 nm ± 1 nm, 23°C ± 3 K, 45 to 75% RH, SM test fiber (9 µm core, 8° APC); at 850, 980 or 1625 nm: ± 0.25 dB (intrinsic) |
| Measurement Uncertainty |
850, 980 nm: ± 0.35 dB; 1310, 1490, 1550 nm: ± 0.25 dB; 1625 nm: ± 0.35 dB
Per-wavelength values printed in the OLP-85/-85P column of the datasheet table |
| Linearity |
± 0.06 dB
Under the following conditions: -50…+ 5 dBm, 0…+45°C |
| Number of Calibrated Wavelengths | 6 (850, 980, 1310, 1490, 1550, 1625 nm) |
| Tone Detection |
CW, 270 Hz, 1 kHz, 2 kHz
Received optical power level ≥ -50 dBm; when used with VIAVI Light Source and received optical power level > -50 dBm |
| Auto Functions |
Auto-λ / Multi-λ
When used with VIAVI Light Source and received optical power level > -50 dBm |
| Optical Connectors | configurable |
| Display |
High contrast 3.5” color LCD touch screen (4:3 ration)
Typical at 25 °C |
|---|---|
| Fiber inspection | Via external P-5000i or via patch cord microscope (P-variants) |
| Data Storage | 10,000 results |
|---|---|
| Data download capability | Via USB interface |
| Remote control capability | Via USB or Ethernet |
| Electrical interfaces | 2x USB-A, 1x micro-USB, 1x Ethernet |
| Wireless interfaces | WiFi or Bluetooth |
| Dry batteries | 8x Mignon (AA) Alkaline 1.5 V |
|---|---|
| Battery pack | 1x Li-ion pack 3.7 V |
| AC operation | Via Universal Power Adapter |
| Operating time | 12 hrs. (OLP) with the dry batteries |
| EMI/ESD | CE compliant |
|---|---|
| Recommended calibration interval | 3 years |
| Operating temperature | -10 to +55°C (14 to 122°F) |
| Storage temperature | -20 to +70°C (-4 to 158°F) |
|
Dimensions (H x W x D)
OLP-85 |
208 x 112 x 64 mm (8.2 x 4.4 x 2.5 in)
Stand alone |
|---|---|
|
Dimensions (H x W x D)
OLP-85P |
208 x 153 x 64 mm (8.2 x 6.0 x 2.5 in)
P-variants |
|
Weight
OLP-85 |
750 g (1.6 lbs.)
Stand alone |
|
Weight
OLP-85P |
850 g (1.85 lbs.)
P-variants |
|
Live Image
OLP-85P |
320 x 240 x 8 Bit Gray, 10 fps
Typical at 25 °C |
|---|---|
|
Light Source
OLP-85P |
Blue LED, 100,000+ hour life |
|
Lighting Technique
OLP-85P |
Coaxial |
|
Low-Magnification Field-of-View (FOV)
OLP-85P |
Horizontal: 740 µm; Vertical: 550 µm |
|
High-Magnification Field-of-View (FOV)
OLP-85P |
Horizontal: 370 µm; Vertical: 275 µm |
|
OLP-85 - Broadband Power Meter 100 dB dynamic range
OLP-85 |
2307/03 |
|---|---|
|
OLP-85P - Broadband Power Meter 100 dB dynamic range and PCM
OLP-85P |
2308/03 |
Applications
- Measurement of optical power (absolute and relative)
- Measurement of optical insertion loss with a VIAVI OLS-3x or OLS-8x light source
- Inspection of optical connectors (IBYC)
- In-service loss testing
Options & Accessories
| Option | Description |
|---|---|
| 2307/90.01 | Calibration Report for OLP-85 |
| 2308/90.01 | Calibration Report OLP-85P |
| 2327/90.01 | WiFi adapter spare |
| 2327/90.02 | Bluetooth adapter spare |
| VPP-UPP25 | UPP 2.5 mm for Power Meters |
| VPP-UPP12 | UPP 1.25 mm for Power Meters |
| 2014/00.09 | FC Type NTT.D3 (for OLP-85) |
| 2014/00.17 | DIN 47256 LSA -PC -APC (for OLP-85) |
| 2014/00.21 | ST Type (for OLP-85) |
| 2014/00.24 | SC/PC SC/APC (for OLP-85) |
| 2014/00.26 | E-2000 -PC -APC (for OLP-85) |
| 2014/00.28 | UPP for LC MU D 1.25 mm (for OLP-85) |
| 2014/00.29 | LC F-3000 -PC -APC (for OLP-85) |
| 2014/00.31 | UPP for DIN FC SC ST and MST D 2.5 mm (for OLP-85) |
| 2229/90.01 | 2x Alkaline batteries Mignon AA-Size LR6 — Four of this item are required for one SmartClass Fiber instrument, i.e. a total of 8 batteries |
| 2305/90.02 | Rechargeable Battery Pack |
| 2305/90.04 | Rechargeable Battery Pack with Power Supply |
| 2305/90.01 | Power Supply |
| FITP-UC4 | Carrier For Displays Without PCM |
| FITP-UC4P | Carrier For Displays With PCM (for P-variant) |
| 2128/03 | Soft Shoulder Case for 1 instrument |
| 2128/04 | Soft Shoulder Case for up to 4 instruments |
| FBP-SD101 | P5000i digital analysis microscope with 4 tips |