VIAVI SmartPocket V2 OLP-39 TruePON tester
VIAVI / OLP-39 / TruePON Testers
OLP-39X

SmartPocket V2 OLP-39X TruePON Tester for G-PON and XGS-PON

Pocket TruePON tester with selective G-PON (1490 nm) and XGS-PON (1577 nm) power measurement and PON-ID analysis

Photo Diode
InGaAs
Resolution
0.01 dB, 0.001 µW
Measurement Range for Power Level
-35…+10 dBm
Measurement Range for PON-ID (GPON)
GPON: -30…0 dBm
Datasheet

Overview

The VIAVI SmartPocket V2 OLP-39X is a TruePON tester in the SmartPocket V2 family of pocket-sized fiber test instruments. It is intended for fiber technicians working in the last mile of FTTH deployments. It is a wavelength-selective Passive Optical Network (PON) power meter with TruePON data analysis of the downstream PON-ID.

TruePON analysis

TruePON lets the instrument read the OLT-ID carried in the downstream PON-ID data. This confirms that the technician is at the right drop terminal and that the drop fiber connects back to the correct OLT port. The instrument also detects the ODN class, which allows in-service insertion loss measurement. The PON-ID data it reads is standardized by ITU-T G.984.3 Amendment 3 for G-PON and by ITU-T G.987.3 Amendment 1 for XGS-PON. TruePON information is attached to stored measurement results. This gives an audit trail, or birth certificate, that records the power levels and OLT connectivity at the time of install.

ONT detection

An optional ONT detection function identifies the serial number, ONT type, ONT-ID and status of the ONT under test. This gives a 1:1 assignment of OLT port and ONT serial number.

Field use and data handling

The tester has one SC test port for measurement and IP44 protection against water and dirt. It runs on AA batteries or USB-C power, and its display uses softkeys. Results can be downloaded over USB-C to a PC. They can also be synced over Bluetooth Low Energy through the Mobile Tech App to StrataSync.

Key Features

  • Wavelength-selective PON power meter with PON-ID capabilities in a pocket-sized form factor
  • TruePON analysis and in-service insertion loss measurement
  • Reads PON-ID data to detect the OLT-ID
  • Detects ODN class for in-service insertion loss measurement
  • Extracts PON-ID data standardized by ITU-T G.984.3 Amendment 3 and ITU-T G.987.3 Amendment 1
  • ONT detection identifies ONT serial number, ONT type, ONT-ID and ONT status
  • Single test port connection for measurement
  • Storage for over 1000 test results
  • PC download via USB-C and Bluetooth Low Energy sync via Mobile Tech App to StrataSync
  • TruePON information attached to stored results as an audit trail of power levels and OLT connectivity
  • IP44 rating with water and dirt protection in a rugged pocket form factor
  • Long battery life and multiple powering options
  • Clear display and simple user interface with softkeys
  • Simultaneous selective power measurement and TruePON PON-ID data analysis of G-PON (1490 nm) and XGS-PON (1577 nm)
  • Detects the OLT-ID for both G-PON and XGS-PON
  • Supports co-existence of G-PON and XGS-PON for migration to 10G services
  • Simultaneous power level measurements for G/E-PON and XGS-PON/10G-EPON services

Specifications

Optical Measurement
Photo Diode InGaAs
Resolution 0.01 dB, 0.001 µW
Measurement Range for Power Level -35…+10 dBm
Measurement Range for PON-ID (GPON) GPON: -30…0 dBm
Max. Power Level (before damage) + 15 dBm
Measurement Uncertainty (1490 nm) 1490 nm: ±0.5 dB / ±12 %
under reference conditions: -2 dBm (CW), nominal wavelength, 23 °C ±3 K, 45 to 75 % relative humidity, SM test fiber (Single Mode, 9µm core, 8° APC), when used with SC/APC connectors
Number of Calibrated Wavelengths 2 (1490, 1577 nm)
Optical Connectors 1x SC/APC
Spectral Range Passband (1480…1500 nm, 1575…1580 nm)
Wavelength Setting 1490 nm, 1577 nm
Measurement Range for PON-ID (XGS-PON) XGS-PON: -25…0 dBm
Measurement Uncertainty (1577 nm) 1577 nm: ±0.5 dB / ±12 %
under reference conditions: -2 dBm (CW), nominal wavelength, 23 °C ±3 K, 45 to 75 % relative humidity, SM test fiber (Single Mode, 9µm core, 8° APC), when used with SC/APC connectors
Storage and Interface
Data Storage 1,000 Results
General (typical at 25°C)
Data Download Capability USB-C for PC/Laptop Transfer or BLE to StrataSync via MTA
Power Supply
Batteries 2x Mignon (AA) Size
AC Operation Via USB-C and Universal Power Adapter (Pmax.: 2.5 W)
Operating Time (PON Mode) 45 hrs.
OLP-39G/-39X in PON Mode; continuous operation with dry batteries
Operating Time (TruePON or ONT Detection Mode) 15 hrs.
OLP-39G/-39X in TruePON or ONT Detection Mode; continuous operation with dry batteries
Safety and Environmental Conditions
EMI/ESD CE Compliant
Electromagnetic Compatibility EN 61326-1:2013
Device Safety EN 61010-1:2010/A1:2019
Recommended Calibration Interval 3 Years
Operating Temperature -10 to +55 °C (14 to 131 °F)
Storage Temperature -20 to +70 °C (-4 to +158 °F)
Max. Altitude 2,000 m (6,500 ft)
Pollution Degree 2
Ingress Protection IP44
Humidity 15 to 85 % (Relative) up to +31 °C; 20 g/m3 (Absolute) > +31 °C
occasional condensation is tolerable as a limit condition
Physical
Dimensions (H x W x D) 30 x 80 x 150 mm (1.2 x 3.1 x 5.9 in)
Weight (w/o Batteries) 200 g (0.45 lb)

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Optical power level measurement for PON services
  • Detecting OLT-ID information
  • Detecting ONT serial number, ONT-ID, type and status
  • Multi-service PON deployment and installs
  • Network build and maintenance for FTTH
  • Confirming drop terminal and drop fiber connectivity to the correct OLT port
  • Verifying end-to-end PON optical loss before installation
  • Measuring optical power levels for G/E-PON and XGS-PON/10G-EPON services
  • Migration to XGS-PON for 10G service deployment

Included

  • Instrument
  • Switchable adapter
  • Belt bag
  • Neck strap
  • Quick start guide
  • Safety instructions
  • Alkaline batteries
  • USB cable

Options & Accessories

Option Description
2336/94.02G ONT detection SW option for OLP-39G/X via SmartReporter
2336/94.02S ONT detection SW option for OLP-39G/X via StrataSync and Mobile Tech App (MTA) — Requires StrataSync account
2302/90.04 Calibration Report TruePON Testers (OLP-39G and OLP-39X)
2302/90.05 Battery Extension (w/o Power Bank) for OLP-39G/-39X
2229/90.21 OCK-10 Cleaning Kit complete
22122619 USB 2.0 Type A to Type C Cable
2229/90.01 2x Alkaline Batteries Mignon AA-Size LR6
2302/90.01 Universal AC Power Adapter
OLP-39X-ONT-KIT OLP-39X ONT Detection Kit — Includes TruePON Tester content, ONT Detection SW option (already installed), Battery Extension (w/o Power Bank), Coupler