VIAVI Micro iOTDR Card Medium and Long Range Integrated OTDR for Network Elements
Integrated OTDR card for network elements, available in medium and long range versions with up to 40 dB dynamic range and Ethernet control.
- Dimensions
- 91 x 170 x 16.5 mm
- Operating temperature
- -5 to 65°C or 70°C according to the variant
- Storage temperature
- -20 to 85°C
- Humidity
- 85% without condensing
Overview
The VIAVI Micro iOTDR Card is a compact integrated OTDR (iOTDR) designed for network element manufacturers (NEMs) to build remote fiber testing into equipment such as amplifiers and switches. It allows operators to locate fiber faults that degrade network traffic and cause latency, jitter, service quality issues and outages.
The card is offered in medium range and long range versions and supports in-service testing and monitoring routines to characterize fiber, identify faults, detect tapping intrusion attempts and track fiber degradation for preventative maintenance. It is intended for xWDM, FTTx, PON and 4G/5G fiber networks, as well as dark fiber testing.
The card is controlled over an Ethernet interface and is supported by a software library covering many remote fiber test use cases. VIAVI professional services can assist with integrating and testing the card within a larger system.
Key Features
- Medium or long distance high accuracy OTDR
- Short dead zone
- In-service fiber testing
- Controlled via Ethernet interface
- Large software library
- High distance accuracy
- Low power consumption
- Pluggable hardware package for integration into optical network elements
- Support from VIAVI OTDR experts for development teams
- For use in PON, XGS-PON, 5G, DWDM, CWDM and dark fiber testing
Specifications
| Dimensions | 91 x 170 x 16.5 mm |
|---|---|
| Operating temperature | -5 to 65°C or 70°C according to the variant |
| Storage temperature | -20 to 85°C |
| Humidity | 85% without condensing |
| EMC | EN61326-1, EN6100-3-2 |
| Interfaces | Ethernet 10/100/1000 |
| Power consumption | 5.1 W (Typical at 25°C) 10mW in standby mode |
| Laser safety | Class 1 |
|---|---|
| Number of data points | Up to 512,000 |
| Sampling resolution | From 4 cm |
| Distance range | Up to 260 Km |
| Distance accuracy | ±1m ±Sampling resolution ±distance * 10-5 |
|
Wavelength
Medium Range
|
1625 nm
Laser at 25°C and measured at 10 µs; typical at 25°C
|
|---|---|
|
Wavelength accuracy
Medium Range
|
±3 nm
Laser at 25°C and measured at 10 µs
|
|
Dynamic range
Medium Range
|
37 dB
One way difference between the extrapolated backscattering level at the start of the fiber and the RMS noise level, after 3 minutes averaging and using the largest pulse width
|
|
Pulse width
Medium Range
|
5 ns to 20 µs |
|
Event dead zone
Medium Range
|
1 m
Measured at ±1.5 dB down from the peak of an unsaturated reflective event using the shortest pulse width
|
|
Attenuation dead zone
Medium Range
|
3.5 m
Measured at ±0.5 dB from the linear regression using a -55dB type reflectance and using the shortest pulse width
|
|
Wavelength
Long Range
|
1610 or 1626 nm
Web page value; the datasheet lists long range variants at 1610 nm, 1625 nm, 1625 nm and 1550/1625 nm
|
|---|---|
|
Wavelength accuracy
Long Range
|
±3 / ±3 / ±20 / ±20 nm
Per datasheet variant column order 1610 nm / 1625 nm / 1625 nm / 1550/1625 nm; web page lists +/-3
|
|
Dynamic range
Long Range
|
40 / 40 / 45 / 45/45 dB
Per datasheet variant column order; after 3 minutes averaging using the largest pulse width; web page lists 40
|
|
Pulse width
Long Range
|
5 ns to 20 µs |
|
Event dead zone
Long Range
|
0.8 m
Measured at ±1.5 dB down from the peak of an unsaturated reflective event using the shortest pulse width
|
|
Attenuation dead zone
Long Range
|
3 m
Measured at ±0.5 dB from the linear regression using a -55dB type reflectance and using the shortest pulse width
|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Fiber characterization
- Fiber monitoring
- Tapping security intrusion detection
- Fault demarcation
- Raman amplified link test
- Fiber degradation tracking for preventative maintenance