CellAdvisor JD724C Cable and Antenna Analyzer, 5 MHz to 4 GHz
Handheld 5 MHz to 4 GHz cable and antenna analyzer for 1-port line sweep, RF and optical power measurement and fiber inspection.
- Range
- 5 MHz – 4 GHz
- Resolution
- 10 kHz
- Accuracy
- ±5 ppm at 25°C
- Aging per year
- ± 1.5 ppm
Overview
The VIAVI CellAdvisor JD724C is a handheld cable and antenna analyzer in the JD720C series, covering 5 MHz to 4 GHz. It is intended for cell-site installation and maintenance, combining line sweep measurement, RF and optical power measurement, and fiber inspection in one instrument.
Most problems in wireless networks occur in the base station infrastructure: the antenna system, cables and connectors, typically in the coax or fiber feed-line. Contamination of fiber connectors is the most common fiber-related problem. Networks with fiber feed-lines require verification of both RF and fiber, which the JD720C series handles in a single unit.
The JD724C performs 1-port measurements to characterize cell-site cable and antenna systems, including VSWR and return loss reflection, distance to fault (DTF), 1-port cable loss, 1-port phase and Smith chart. With external sensors it measures RF power, and with VIAVI optical power meters and the P5000i fiber microscope it measures optical power and inspects fiber connectors with pass/fail indication.
A 7-inch color touch-screen display presents results, and connectivity to VIAVI application software (JDViewer, JDRemote) supports post-analysis, report generation and remote control. Optional Bluetooth, WiFi and USB GPS connectivity and the TestWizard self-guided test option are available.
Key Features
- RF and fiber testing in a single solution
- Trace Overlay to detect signal degradation over time
- Two measurements displayed simultaneously on one screen
- PASS/FAIL indications
- EZ-Cal electronic calibration support
- Fiber inspection with PASS/FAIL indications using the P5000i fiber microscope
- RF and optical power measurement using power sensors
- Three zoom zones for detailed analysis on multi-frequency bands
- Up to 40 dBm (10 W) RF port protection
- PDF/HTML report generation
- Automatic saving of events that exceed pre-defined limits
- Application software for post-analysis (JDViewer) and remote control (JDRemote)
- Web-based remote control via Bluetooth and Wi-Fi
- Self-guided systematic test procedures with TestWizard (option)
- Database of over 80 wireless frequency bands and over 95 cable types, user-expandable
- Up to six markers for trace analysis
- Multilanguage user interface
Specifications
| Range | 5 MHz – 4 GHz |
|---|---|
| Resolution | 10 kHz |
| Accuracy |
±5 ppm at 25°C
For JD723C/JD724C, applies to serial number IDE33869 and later
|
| Aging per year |
± 1.5 ppm
For JD723C/JD724C, applies to serial number IDE33869 and later
|
| Data points | 126, 251, 501, 1001, 2001 |
| Reflection | < 0.7 ms/point |
|---|---|
| DTF | < 0.8 ms/point |
| Corrected directivity (OSL calibration) |
>42 dB (typical)
After OSL calibration; using recommended calibration kits
|
|---|---|
| Corrected directivity (EZ-Cal calibration) |
≤ 4 GHz: >38 dB (typical)
After EZ-Cal calibration; available only for serial number KR31659001 and later
|
| Reflection uncertainty |
±(0.3 + |20log (1 + 10^(-EP/20))|) (typical)
EP = directivity – measured return loss
|
| Output power, high | 0 dBm (nominal) |
|---|---|
| Output power, low | –30 dBm (nominal) |
| Maximum input level, average continuous power | +25 dBm (nominal) |
| Maximum input level, DC voltage | ±50 V DC |
| VSWR range | 1 to 65 |
|---|---|
| VSWR resolution | 0.01 |
| Return loss range | 0 to 60 dB |
| Return loss resolution | 0.01 dB |
| Vertical VSWR range | 1 to 65 |
|---|---|
| Vertical VSWR resolution | 0.01 |
| Vertical return loss range | 0 to 60 dB |
| Vertical return loss resolution | 0.01 dB |
| Horizontal range | 0 to (# of data points – 1) x horizontal resolution; Maximum = 1500 m (4921 ft) |
| Horizontal resolution |
(1.5 x 10^8) x (VP)/delta
VP = propagation velocity; delta = stop frequency – start frequency (Hz)
|
| 1-port cable loss range | 0 to –30 dB |
|---|---|
| 1-port cable loss resolution | 0.01 dB |
| 1-port phase |
–180 to +180°
Listed as 'Resolution' in the datasheet
|
| Smith chart resolution | 0.01° |
| RF power meter display range |
–80 to +120 dBm
Standard
|
|---|---|
| RF power meter offset range | 0 to 60 dB |
| RF power meter resolution | 0.01 dB or 0.1 x W (x = m, u, p) |
| Optical power meter display range |
–100 to +100 dBm
Standard
|
| Optical power meter offset range | 0 to 60 dB |
| Optical power meter resolution | 0.01 dB or 0.1 mW |
| Bluetooth |
Personal area network (PAN), File transfer profile (FTP) interface
Option 003
|
|---|---|
| WiFi interface type |
USB LAN Card
Option 006
|
| WiFi interface standard |
IEEE 802.11 b/g/n
Option 006
|
| Web-based remote control | Internet Explorer, Chrome, Safari |
| USB GPS location |
Latitude and longitude on display
Option 004
|
| USB GPS interface |
USB 2.0
Option 004
|
| Reflection/RF Out connector | Type-N, female |
|---|---|
| Reflection/RF Out impedance | 50 Ω (nominal) |
| Reflection/RF Out damage level | > +40 dBm, > ±50 V DC (nominal) |
| RF In |
N/A
RF In port not fitted on JD724C
|
| USB host |
Type A, 2 ports
Connects flash drive, power sensor, P5000i, Bluetooth adapter, WiFi LAN card, or GPS receiver
|
| USB client |
Mini B, 1 port
Connects to PC/laptop for data transfer
|
| LAN | RJ45, 10/100Base-T |
| Serial |
9-pin D-SUB male
For JD72450551/JD72450552
|
| Type | Resistive touch screen |
|---|---|
| Size | 7-inch, LED backlight, transflective LCD |
| Resolution | 800 x 480 |
| Speaker | Built-in speaker |
| External DC input | 12 to 15 VDC |
|---|---|
| Power consumption | 12 W; 34.5 W maximum (when charging battery) |
| External AC power adapter input | 100 to 250 V (50 to 60 Hz, 1.2 A) |
| External AC power adapter output | 15 V DC, 4 A |
| Battery type | 10.8 V, 7800 mA/hr (LiON) |
| Battery operation time | >7.5 hr (typical) |
| Charge time | 3 hr (80%), 5 hr (100%) |
| Charging temperature | 0 to 45°C (32 to 104°F) ≤85% RH |
| Discharging temperature | –20 to 55°C (4 to 131°F) ≤85% RH |
| Battery storage temperature |
0 to 25°C (32 to 77°F) ≤95% RH (noncondensing)
20 to 85% RH; extended exposure to temperatures above 45°C could significantly degrade battery performance and life
|
| Internal |
Maximum 900 MB
Up to 26,000 traces (JD723C/JD724C)
|
|---|---|
| External |
Limited by size of USB flash drive
Supports USB 2.0-compatible memory devices
|
| Operating temperature, AC power | 0 to 40°C (32 to 104°F) with no derating |
|---|---|
| Operating temperature, battery | 0 to 40°C (32 to 104°F) at charging; –10 to 55°C (14 to 131°F) at discharging |
| Maximum humidity | 95% RH (noncondensing) |
| Storage temperature |
–40 to 70°C (–40 to +158°F)
With the battery pack removed
|
| Shock and vibration | MIL-PRF-28800F Class 2 |
| ESD | IEC/EN 61000-4-2 |
|---|---|
| RoHS | EN 50581:2012 |
| Size (W x H x D) |
260 x 190 x 60 mm (10.2 x 7.5 x 2.4 in)
With battery
|
|---|---|
| Weight |
2.35 kg (5.18 lb)
With battery
|
| Calibration cycle | 2 years |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Cell-site cable and antenna system verification
- Distributed radios with RF and fiber feed-lines
- DAS deployment validation
- NFC antenna testing (RFID and security equipment)
Included
- AC/DC power adapter
- Cross LAN cable
- USB A to Mini B cable
- USB memory
- Automotive cigarette lighter/12 V DC adapter
- Rechargeable LiON battery
- Stylus pen
- Soft carrying case
- JD720C series user's manual and application software
Options & Accessories
| Option | Description |
|---|---|
| JD720C003 | Bluetooth connectivity — Includes a USB Bluetooth dongle and dipole antenna (JD70050006) |
| JD720C004 | USB GPS connectivity — Includes a USB GPS receiver |
| JD720C006 | WiFi connectivity — Includes a WiFi dongle (JD70050008) |
| JD720C007 | TestWizard — Self-guided systematic test procedures using Test Wizard files created in Test Wizard Creator |
| JD78050509 | Y-calibration kit Type-N(m), DC to 6 GHz, 50 Ω |
| JD78050510 | Y-calibration kit DIN(m), DC to 6 GHz, 50 Ω |
| JD70050509 | Electronic calibration kit (EZ-Cal) |
| G700050530 | RF cable DC to 8 GHz Type-N(m) to Type-N(m), 1.0 m |
| G700050531 | RF cable DC to 8 GHz Type-N(m) to Type-N(f), 1.5 m |
| G700050532 | RF cable DC to 8 GHz Type-N(m) to Type-N(f), 3.0 m |
| G710050536 | RF cable DC to 6 GHz Type-N(m) to DIN(f), 1.5 m |
| G700050540 | Phase-stable RF cable with grip DC to 6 GHz Type-N(m) to Type-N(f), 1.5 m |
| G700050541 | Phase-stable RF cable with grip DC to 6 GHz Type-N(m) to DIN(f), 1.5 m |
| JD731B | Directional power sensor (peak and average), 300 MHz to 3.8 GHz, average 0.15 to 150 W, peak 4 to 400 W |
| JD733A | Directional power sensor (peak and average), 150 MHz to 3.5 GHz, average/peak 0.1 to 50 W |
| JD732B | Terminating power sensor (average), 20 MHz to 3.8 GHz, –30 to +20 dBm |
| JD734B | Terminating power sensor (peak), 20 MHz to 3.8 GHz, –30 to +20 dBm |
| JD736B | Terminating power sensor (peak and average), 20 MHz to 3.8 GHz, –30 to +20 dBm |
| MP-60A | USB optical power meter with software, 2.5 and 1.25 mm interfaces, 30-inch USB extender, and carrying pouch |
| MP-80A | USB optical power meter — high power, with software, 2.5 and 1.25 mm interfaces, 30-inch USB extender, and carrying pouch |
| FBP-SD101 | KIT: FBP-P5000i digital probe, FiberChekPRO software, case, and four tips |
| FBP-MTS-101 | KIT: FBP-P5000i digital probe, FiberChekPRO software, case, and seven tips |
| FIT-SD103 | KIT: FBP-P5000i digital probe, MP-60A USB power meter, FiberChekPRO software, case, tips, and adapters |
| FIT-SD103-C | KIT: FBP-P5000i digital probe, MP-60A USB power meter, FiberChekPRO software, case, tips, adapters, and cleaning materials |
| FIT-SD113 | KIT: FBP-P5000i digital probe, MP-80A USB power meter, FiberChekPRO software, case, tips, and adapters |
| G710050581 | Attenuator 40 dB, 100 W, DC to 4 GHz (unidirectional) |
| GC72450522 | AC/DC power adapter for JD723C and JD724C only |
| G710550325 | Rechargeable LiON battery |
| G710550324 | External battery charger |
| JD72050541 | JD720C soft carrying case |
| JD70050542 | JD720 hard carrying case with wheels |
| JD70050343 | CellAdvisor backpack carrying case |
| JD70050006 | USB Bluetooth dongle and dipole antenna 5 dBi |
| JD70050008 | USB WiFi dongle |
| JD72050005 | USB GPS receiver |
| JD720C362 | JD720C series user's manual, printed version |
| JD723C/24C-EW | JD723C/724C warranty extension |
| JD723/24-CP2 | 1 Calibration over 2 year period for JD723C or JD724C |
| JD723/4-CAL | Certified Calibration for JD723/724 |
| JD720C100 | Certificate of calibration with test data for new instrument |