8100-Series OTDR EVO E8136D 1310/1550/1625 nm OTDR Module for OneAdvisor 800 Fiber
Tri-wavelength 1310/1550/1625 nm OTDR EVO module for the OneAdvisor 800 with up to 50 dB dynamic range and integrated source and power meter.
- Weight
- approx. 500 g (1.1 lb)
- Dimensions (W x H x D)
- 213 x 124 x 32 mm (8.38 x 4.88 x 1.26 in)
- Laser safety class (21 CFR)
- Class 1
- Distance units
- Kilometer, meter, feet, and miles
Overview
The VIAVI E8136D is the 1310/1550/1625 nm member of the 8100-Series OTDR EVO module family for the OneAdvisor 800 Fiber platform. The 8100D OTDR EVO modules are intended for the installation, turn-up and maintenance of single-mode standard and hollow core fiber in metro, long-haul and ultra-long-haul networks, as well as for fiber monitoring in and out of service and for submarine cable network certification and troubleshooting.
The module combines an OTDR, a broadband power meter and a continuous-wave light source on a single OTDR port. It offers up to 50 dB dynamic range with up to 256,000 acquisition points, a 0.5 m event dead zone and a 2.5 m attenuation dead zone, allowing closely spaced elements on a fiber link to be characterized. The module is PON-optimized to test through a 1x128 splitter.
Automatic traffic detection checks for live signals before an acquisition to avoid interference with, or damage to, an active optical transmitter. Smart Link Mapper (SLM) presents the measured link as an icon-based map to reduce OTDR interpretation errors without adding test time. Standard testing features include automatic macrobend detection, a summary results table with pass/fail analysis and FastReport onboard report generation.
Hollow core fiber
The 8100D modules also characterize hollow core fiber, with a dedicated dynamic range specification and a defined attenuation dead zone at the transition from solid core to hollow core fiber. VIAVI publishes a separate application note on testing hollow core fibers.
Key Features
- Up to 50 dB dynamic range and 256,000 acquisition points
- 0.5 m event dead zone and 2.5 m attenuation dead zone
- Integrated CW light source and broadband power meter on the OTDR port (single-mode wavelengths)
- PON-optimized to test through a 1x128 splitter
- Tri-wavelength 1310/1550/1625 nm version of the 8100D OTDR EVO module
- Single connector port for OTDR, light source and power meter
- Instantaneous automatic traffic detection avoids live signal interference or transmitter damage
- Smart Link Mapper (SLM) eliminates OTDR interpretation errors without compromising test time
- Automatic macrobend detection
- Summary results table with pass/fail analysis
- FastReport onboard report generation
- Reduced event loss measurement uncertainty and improved measurement repeatability
- Characterizes both single-mode standard and hollow core fibers
- Module for the OneAdvisor 800 Fiber platform
Specifications
| Weight | approx. 500 g (1.1 lb) |
|---|---|
| Dimensions (W x H x D) | 213 x 124 x 32 mm (8.38 x 4.88 x 1.26 in) |
| Laser safety class (21 CFR) | Class 1 |
| Distance units | Kilometer, meter, feet, and miles |
| Group index range | 1.00000 to 1.70000 in 0.00001 steps |
| Number of data points | Up to 256,000 data points |
| Platform | OneAdvisor 800 Fiber platform |
| Mode | Automatic or dual cursor |
|---|---|
| Display range | Single-mode: 0.1 – 400 km |
| Display resolution | 1 cm |
| Cursor resolution | From 1 cm |
| Sampling resolution | From 4 cm |
| Accuracy |
Single-mode: ± (0.75 m + sampling resolution + 0.001% x distance)
Excluding group index uncertainties
|
| Mode | Automatic, manual, 2-point, 5-point, and LSA |
|---|---|
| Display resolution | 0.001 dB |
| Linearity | Single-mode: ±0.03 dB/dB |
| Threshold | 0.01 to 4.99 dB in 0.01 dB steps |
| Mode | Automatic or manual |
|---|---|
| Reflectance accuracy | ±2 dB |
| Display resolution | 0.01 dB |
| Threshold | –11 to –99 dB in 1 dB steps |
|
Wavelengths
E8136D
|
1310/1550/1625 nm
E8136D is the 1310/1550/1625 nm OTDR module
|
|---|---|
|
Central wavelength (1310 nm)
E8136D
|
1310 ±20 nm
Laser at 25°C and measured at 10 µs
|
|
Central wavelength (1550 nm)
E8136D
|
1550 ±20 nm
Laser at 25°C and measured at 10 µs
|
|
Central wavelength (1625 nm)
E8136D
|
1625 +15/–5 nm
Laser at 25°C and measured at 10 µs
|
| Dynamic range |
50/50/50/48 dB
Values listed for the 8100D family at 1310/1550/1625/1650 nm respectively; one-way difference between extrapolated backscattering level at the start of the fiber and the RMS (SNR=1) noise level, after 3 minutes averaging using the largest pulse width
|
| Pulse width | 2 ns to 20 µs |
| Event dead zone |
0.5 m
Measured at ±1.5 dB below the peak of an unsaturated reflective event using the shortest pulse width. Web page states ≤ 65 cm; datasheet value used
|
| Attenuation dead zone |
2.5 m
Measured ±0.5 dB from the linear regression using an FC/UPC reflectance and the shortest pulse width
|
| Splitter attenuation dead zone | 15 m after a 15 dB splitter loss |
| PON splitter test capability | PON-optimized to test through a 1x128 splitter |
| Dynamic range |
35/35/35/33 dB
Values listed for the 8100D family at 1310/1550/1625/1650 nm respectively; one-way difference between extrapolated backscattering level at the start of the fiber and the RMS (SNR=1) noise level, after 3 minutes averaging using the largest pulse width
|
|---|---|
| Solid core to hollow core transition attenuation dead zone |
15 m after a 15 dB Rayleigh backscattering difference
Measured on a non-reflective transition at 100 ns, after a 15 dB Rayleigh backscattering difference between solid core fiber and hollow core fiber
|
| Calibrated wavelengths | 1310/1490/1550/1625 nm |
|---|---|
| Power range | –5 to –55 dBm |
| Accuracy |
±0.5 dB at –30 dBm
At calibrated wavelengths
|
| Wavelengths |
1310/1550/1625 nm
At calibrated wavelengths
|
|---|---|
| Output power | 0 dBm |
| Stability | ±0.1 dB at 25°C over 1 hour |
| Operating modes |
270 Hz, 330 Hz, 1 kHz, 2 kHz, TWINtest
Subtract 3 dB when in modulation mode (270 Hz/330 Hz/1 kHz/2 kHz)
|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Metro, long-haul and ultra-long-haul fiber network characterization
- Access fiber network characterization
- Advanced FTTH PON network qualification and troubleshooting
- Hollow core fiber test and certification for high-speed networks and data center interconnects
- Upgrading core fiber networks up to 800G
- Remote fiber monitoring in and out of service
- Fiber installation and deployment certification and troubleshooting for submarine cable networks
Options & Accessories
| Option | Description |
|---|---|
| EUNIPCFC | Universal optical connector, straight, FC |
| EUNIPCSC | Universal optical connector, straight, SC |
| EUNIPCST | Universal optical connector, straight, ST |
| EUNIPCDIN | Universal optical connector, straight, DIN |
| EUNIAPCFC | Universal optical connector, 8° angled, FC |
| EUNIAPCSC | Universal optical connector, 8° angled, SC |
| EUNIAPCDIN | Universal optical connector, 8° angled, DIN |
| ELCSMXX-YY-ZZ | Single-mode OTDR launch/receive cable — XX: fiber length in meters (20, 25, 100, 150, 500, 1000, 2000, 2200); YY: connector A type (SCA, LC, MPO); ZZ: connector B type (SC, SCA, LC, MPO). MPO versions available in 20 m or 25 m only. |