Luna PSGA-101A Polarization Measurement System
Luna / Optical Component Test / Component Characterization
PSGA-101A

Luna PSGA-101A Polarization Measurement System

Polarization measurement system that measures SOP, DOP, DGD, SOPMD, PDL and PER of light and optical components versus wavelength.

Wavelength range
1440-1620nm
Wavelength range
1280-1340nm
Stokes vector accuracy
±0.5%
DOP accuracy
±1%
Datasheet

Overview

The Luna PSGA-101A is a polarization measurement system that measures all polarization-related properties of light, including state of polarization (SOP), degree of polarization (DOP), differential group delay (DGD), second-order PMD (SOPMD), polarization dependent loss (PDL) and polarization extinction ratio (PER). The manufacturer has discontinued it. Luna lists the Optical Vector Analyzer (OVA 5100) as its replacement.

The system has three main parts: a tunable laser, a polarization state generator (PSG) that produces the six basis polarization states commonly used for measurement, and a polarization state analyzer (PSA) that performs the polarization measurements. The PSG and PSA use Luna's patented magneto-optic polarization generation and analysis technology to measure PDL and polarization mode dispersion (PMD) versus wavelength.

The PSGA-101A can also monitor SOP and DOP, measure PER, measure the Mueller matrix of devices or components, and measure birefringence in spun fiber.

The three modules can be used on their own or together, depending on the measurement. With the internal C-band tunable laser, the system measures PMD up to 10 ps. Larger PMD values can be measured by using external lasers.

Key Features

  • Flexible setup for different measurements
  • Simultaneous measurement of DGD, SOPMD, PDL
  • Jones or Mueller Matrix methods
  • Free space PSA input enables absolute SOP measurements
  • GPIB control of external lasers

Specifications

Performance
Wavelength range 1440-1620nm
First wavelength configuration
Wavelength range 1280-1340nm
Second wavelength configuration
Stokes vector accuracy ±0.5%
Both wavelength ranges
DOP accuracy ±1%
Both wavelength ranges
PMD measurement range (1440-1620nm) 1 fs to 10 ps
Internal laser
PMD measurement range (1440-1620nm) 1 fs to 400 ps
External laser
PMD measurement range (1280-1340nm) 1 fs to 400 ps
External laser
PDL measurement range 0 to 40 dB
Both wavelength ranges
DGD accuracy (1440-1620nm) ±(1 fs + DGD * 0.5%)
DGD accuracy (1280-1340nm) ±(5 fs + DGD * 1%)
SOPMD accuracy (1440-1620nm) ±(SOPMD * 1%)
SOPMD accuracy (1280-1340nm) ±(SOPMD * 2%)
PDL accuracy ±(0.05 dB + PDL * 2%)
Both wavelength ranges

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • System and component PMD/PDL characterization
  • PM fiber connector characterization (PER, angle, connector stress)
  • Spun fiber birefringence measurement
  • Circular birefringence measurement
  • PIC and silicon photonics test
  • Manufacturing test of fiber optic assemblies