Site Master MS2085A/MS2089A Handheld Cable and Antenna Analyzer with Spectrum Analyzer and VNA Option
Handheld cable and antenna analyzer family to 4 or 6 GHz, with an optional spectrum analyzer (MS2089A) and an optional 2-port, 1-path VNA.
- Frequency range
- 5 kHz to 4 GHz (Option 804)
- Frequency range
- 5 kHz to 6 GHz (Option 806)
- Frequency accuracy
- ≤ ± 0.28 ppm (-10ºC to 55ºC) plus aging
- Frequency accuracy
- ≤ ± 2.5 ppm (-10°C to 55°C) plus aging
Overview
The Anritsu Site Master MS2085A and MS2089A are handheld analyzers for installing, maintaining and troubleshooting RF communication systems up to 6 GHz. Both models combine cable and antenna analysis with an optional vector network analyzer, and the MS2089A adds an integrated spectrum analyzer. Typical uses include broadcast and cellular sites, distributed antenna systems (DAS), satellite monitoring, interference analysis, and aerospace and defense work.
MS2085A cable and antenna analyzer
The MS2085A is a cable and antenna analyzer covering 5 kHz to 4 GHz or 6 GHz. It weighs less than 7 lb and has an IK08-rated 10-inch touch screen. It measures return loss, cable loss, VSWR, distance-to-fault, 1-port phase and Smith chart, with time domain reflectometry available as an option. It can generate PDF/HTML reports and manage cable lists directly on the instrument.
MS2089A with spectrum analyzer
The MS2089A comes in two configurations: a 5 kHz to 4 GHz cable and antenna analyzer with a 9 kHz to 4 GHz spectrum analyzer, or a 5 kHz to 6 GHz cable and antenna analyzer with a 9 kHz to 6 GHz spectrum analyzer. It weighs less than 8.5 lb and uses the same IK08 10-inch touch screen. Spectrum analyzer options include real-time spectrum analysis, IQ capture and streaming, interference finding, channel scanning, coverage mapping, and WCDMA, LTE FDD/TDD and 5G NR FR1 signal analysis.
Vector network analyzer and vector voltmeter options
The optional VNA is a 2-port, 1-path analyzer to 4 or 6 GHz with a 380 µs/point sweep speed. It ships with a default ReadyCal calibration and also supports mechanical and InstaCal user calibrations, with 16 display formats including log magnitude, VSWR, phase, Smith chart, group delay and polar. The vector voltmeter option is intended for tasks such as matching cable phase.
Software compatibility
The instruments work with Anritsu Remote and Report Tools (ARRT), the IQ Signal Master MX280005A vector signal analysis software, the Mobile InterferenceHunter MX280007A and the Vision MX280001A remote spectrum monitoring software.
Models in this series
| Model | Description | |
|---|---|---|
| MS2085A |
Site Master MS2085A Handheld Cable and Antenna Analyzer with Vector Network Analyzer Option
Handheld cable and antenna analyzer covering 5 kHz to 4 GHz or 6 GHz, with an optional 2-port, 1-path vector network analyzer. |
Details → |
| MS2089A |
Site Master MS2089A Handheld Cable and Antenna Analyzer with Spectrum Analyzer and VNA Option
Handheld cable and antenna analyzer to 4 or 6 GHz with an integrated 9 kHz to 4/6 GHz spectrum analyzer and optional 2-port, 1-path VNA. |
Details → |
Key Features
- Cable and Antenna Analyzer: 5 kHz to 4, 6 GHz
- Return Loss, Cable Loss, VSWR, Distance-To-Fault, Time Domain Reflectometry, Smith Chart, 1-Port Phase
- 105 dB of dynamic range from 50 kHz to 3 GHz typical
- 350 μs/data point in fast sweep mode
- Built-in PDF/HTML report generation
- 10,049 data points
- Add, edit, import and export a cable list from the instrument
- Spectrum Analyzer: 9 kHz to 4, 6 GHz (MS2089A)
- Real-Time Spectrum Analyzer (RTSA)
- IQ Capture/streaming
- Interference Analyzer
- True Power Meter
- AM/FM Modulation Quality Measurements
- LTE FDD/TDD Analyzer
- 5GNR FR1 Analyzer
- Coverage Mapping
- Vector Network Analyzer: 5 kHz to 4, 6 GHz
- 2-port, 1-path measurements
- 380 µs/point fast sweep speed (VNA)
- Default ReadyCal plus support for Mechanical and InstaCal user calibrations
- 16 display formats including Log Mag, VSWR, Phase, Group Delay, Smith Chart, Polar
- Field-proven design: Explosive Atmosphere MIL-PRF-28800F Section 4.5.6.3 compliant
- Complies with IP52 when installed in soft carrying case
- IK08 rated 10-inch touch screen
Specifications
|
Frequency range
MS2085A-0804, MS2089A-0804 |
5 kHz to 4 GHz (Option 804) |
|---|---|
|
Frequency range
MS2085A-0806, MS2089A-0806 |
5 kHz to 6 GHz (Option 806) |
|
Frequency accuracy
MS2089A |
≤ ± 0.28 ppm (-10ºC to 55ºC) plus aging |
|
Frequency accuracy
MS2085A |
≤ ± 2.5 ppm (-10°C to 55°C) plus aging
typical |
| Aging | ± 1 ppm per year |
| Frequency resolution | 1 Hz |
| Output power, High |
0 dBm
typical |
|---|---|
| Output power, Low |
–40 dBm
typical |
| Interference immunity, On-Channel | +17 dBm @ > 1.0 MHz from carrier frequency |
| Interference immunity, On-Frequency | 0 dBm within ±10 kHz of the carrier frequency |
| Corrected directivity |
> 44 dB
typical, OSL Calibration |
|---|---|
| Corrected directivity |
> 40 dB
typical, InstaCal Calibration |
| Sweep speed, Return Loss |
< 350 µs/data point
RF immunity low, typical; low dynamic range and fast sweep rate. 700 µs/data point normal sweep rate, typical |
| Sweep speed, Distance-to-Fault |
< 350 µs/data point
RF immunity low, typical |
| Return loss measurement range | 0 dB to 60 dB |
| Return loss resolution | 0.01 dB |
| VSWR measurement range | 1:1 to 65:1 |
| VSWR resolution | 0.01 |
| Cable loss measurement range | 0 dB to 30 dB |
| Cable loss resolution | 0.01 dB |
| Distance-to-Fault horizontal range | 0 to (Data Points–1) x Fault Resolution, to a maximum of 5000 meters (16404 ft) |
| 1-Port Phase measurement range | –450º to +450º |
| 1-Port Phase resolution | 0.01º |
| Smith Chart marker resolution | 0.01 Ω, 50/75 Ω selectable |
| Data points | Flex Cal: 2 to 10,049, user defined |
|
Distance
Option 3 |
5000 Meters |
|---|---|
|
TDR Ohm measurement range
Option 3 |
0 Ω to 5000 Ω
Resolution 0.01 Ω |
|
TDR Linear measurement range
Option 3 |
0 U to 500 U
Resolution 0.01 U |
|
Frequency range
Option 21 |
5 kHz to 4 GHz (Option 804), 5 kHz to 6 GHz (Option 806) |
|---|---|
|
Dynamic range, 50 kHz to 3 GHz
Option 21 |
90 dB, 105 dB typical
Dynamic range set to high |
|
Dynamic range, 3 GHz to 4 GHz
Option 21 |
80 dB, 95 dB typical
Dynamic range set to high |
|
Dynamic range, 4 GHz to 6 GHz
Option 21 |
70 dB, 85 dB typical
Dynamic range set to high |
|
Frequency range
MS2085A-0904, MS2089A-0904 |
5 kHz to 4 GHz (Option 904) |
|---|---|
|
Frequency range
MS2085A-0906, MS2089A-0906 |
5 kHz to 6 GHz (Option 906) |
| Frequency resolution | 1 Hz |
| Transmission dynamic range, 5 kHz to < 2 MHz |
110 dB typical
300 Hz IF Bandwidth, 100 point averaging, maximum port power |
| Transmission dynamic range, 2 MHz to 2 GHz |
110 dB, 125 dB typical
300 Hz IF Bandwidth, 100 point averaging, maximum port power |
| Transmission dynamic range, >2 GHz to 3 GHz |
105 dB, 120 dB typical
300 Hz IF Bandwidth, 100 point averaging, maximum port power |
| Transmission dynamic range, > 3 GHz to 4 GHz |
100 dB, 113 dB typical
300 Hz IF Bandwidth, 100 point averaging, maximum port power |
| Transmission dynamic range, >4 GHz to 5 GHz |
95 dB, 110 dB typical
300 Hz IF Bandwidth, 100 point averaging, maximum port power |
| Transmission dynamic range, >5 GHz to 6 GHz |
90 dB, 105 dB typical
300 Hz IF Bandwidth, 100 point averaging, maximum port power |
| Sweep speed, 5 kHz to 6 GHz |
380 μs/point
Typical; IF Bandwidth of 100 kHz and 1001 data points |
| Noise floor, 5 kHz to < 2 MHz |
–105 dBm
300 Hz, typical |
| Noise floor, 2 MHz to 2 GHz |
–116 dBm
300 Hz, typical |
| Noise floor, >2 GHz to 3 GHz |
–111 dBm
300 Hz, typical |
| Noise floor, >3 GHz to 4 GHz |
–104 dBm
300 Hz, typical |
| Noise floor, >4 GHz to 5 GHz |
–101 dBm
300 Hz, typical |
| Noise floor, >5 GHz to 6 GHz |
–97 dBm
300 Hz, typical |
| Maximum port power, 2.5 MHz to 5 GHz |
+9 dBm
Default 0 dBm, minimum –45 dBm; settable in 0.1 dB steps |
| Maximum port power, > 5 MHz to 6 GHz |
+8 dBm
Default 0 dBm, minimum –45 dBm; band printed as '> 5 MHz to 6 GHz' in datasheet |
| Corrected directivity, 2 MHz to 6 GHz |
> 44 dB
Typical; OSLN50A-8, OSLNF50A-8, TOSLN50A-8 or TOSLNF50A-8 calibration kit |
| Corrected source match, 2 MHz to 6 GHz |
≥ 30 dB
Typical |
| Data points | 2-16001 |
| IF bandwidth |
10 Hz to 1 MHz
Datasheet highlights on page 2 state IF Bandwidth selections of 10 Hz to 100 kHz |
| Battery life | Greater than 3 hour battery life |
|
Frequency range
MS2089A-0704 |
9 kHz to 4 GHz (Option 704)
usable to 0 Hz |
|---|---|
|
Frequency range
MS2089A-0706 |
9 kHz to 6 GHz (Option 706)
usable to 0 Hz |
|
Tuning resolution
MS2089A |
1 Hz |
|
Span
MS2089A |
10 Hz to max frequency, Zero Span |
|
Frequency reference
MS2089A |
Internal, GNSS, External |
|
External frequency reference
MS2089A |
10 MHz, -10 dBm to +10 dBm |
|
Analysis bandwidth
MS2089A |
20 MHz (standard), 40 MHz (Option 102) |
|
Resolution bandwidth (RBW)
MS2089A |
1 Hz to 5 MHz, 1 Hz to 10 MHz in zero span (standard), 1 Hz to 20 MHz in zero span (Option 102) |
|
Video bandwidth (VBW)
MS2089A |
0.1 Hz to 5 MHz, 1 Hz to 10 MHz in zero span (standard), 1 Hz to 20 MHz in zero span (Option 102) |
|
Sweep points
MS2089A |
10 to 10,001 (1001 in zero span) |
|
Sweep rate (non-zero span)
MS2089A |
32 GHz/s (standard), 45 GHz/s (Option 102) |
|
Zero span sweep time
MS2089A |
60 ns to 3600 s in zero span |
|
Dynamic range
MS2089A |
105 dB typical at 1 GHz
2/3 (TOI-DANL) in 1 Hz RBW |
|---|---|
|
DANL
MS2089A |
–167 dBm
typical with preamp On |
|
Measurement range
MS2089A |
DANL to +30 dBm |
|
Reference level range
MS2089A |
–150 dBm to +30 dBm |
|
Attenuator range
MS2089A |
0 to 50 dB, 5 dB steps |
|
Maximum continuous input
MS2089A |
+30 dBm CW, ±50 VDC
≥ 10 dB attenuation; +23 dBm CW (< 10 dB attenuation); +10 dBm CW (preamp ON) |
|
Damage level
MS2089A |
5 W (+37 dBm) to 6 GHz |
|
Amplitude accuracy, 9 kHz to 6 GHz
MS2089A |
±1.0 dB
Maximum, 20°C to 30°C after 30 minute warm-up; ±0.5 dB typical |
|
Residual spurious
MS2089A |
< –120 dBm
RF input terminated, 0 dB input attenuation, > 20 MHz, preamp On |
|
Input-related spurious
MS2089A |
< –70 dBc
0 dB attenuation, –30 dBm input |
|
SSB phase noise, 10 kHz offset from 1 GHz
MS2089A |
–93 dBc/Hz
Maximum; –94 dBc/Hz typical |
|
SSB phase noise, 100 kHz offset from 1 GHz
MS2089A |
–95 dBc/Hz
Maximum; –97 dBc/Hz typical |
|
SSB phase noise, 1 MHz offset from 1 GHz
MS2089A |
–120 dBc/Hz
Maximum; –123 dBc/Hz typical |
|
Third-order intercept, 1 GHz
MS2089A |
+7 dBm
Typical; –20 dBm tones 100 kHz apart, 0 dB input attenuation, preamp Off |
|
Third-order intercept, 3 GHz
MS2089A |
+14 dBm
Typical |
|
Third-order intercept, 6 GHz
MS2089A |
+17 dBm
Typical |
|
Input VSWR, 9 kHz to 2.0 GHz
MS2089A |
1.5:1 typical
≥ 10 dB input attenuation |
|
Input VSWR, 2 GHz to 6.0 GHz
MS2089A |
1.8:1 typical
≥ 10 dB input attenuation |
|
Battery life
MS2089A |
Up to 6 hours |
|
FFT rate
MS2089A-0199 |
527,000 FFT/s (normal resolution), 263,000 FFT/s (high resolution) |
|---|---|
|
Minimum detectable signal
MS2089A-0199 |
9 ns |
|
Maximum span
MS2089A-0199 |
20 MHz standard, 40 MHz with Option 102 |
|
Acquisition time
MS2089A-0199 |
50 ms to 5 s |
|
Maximum sample rate
MS2089A-0126 |
50 MHz
Option dependent |
|---|---|
|
Maximum signal bandwidth
MS2089A-0126 |
40 MHz
Standard analysis bandwidth up to 20 MHz, Option 102 up to 40 MHz |
|
Bit resolution
MS2089A-0126, MS2089A-0127 |
8, 10, 16, or 32-bit |
|
Total capture memory
MS2089A-0126 |
2 GB |
|
Frequency range
MS2089A-0704-0020, MS2089A-0706-0020 |
9 kHz to 6 GHz |
|---|---|
|
Settable power range
MS2089A-0704-0020, MS2089A-0706-0020 |
–45 dBm to +9 dBm
Minimum leveled power -40 dBm < 2.5 MHz |
|
Output connector
MS2089A-0704-0020, MS2089A-0706-0020 |
N female, 50 Ω |
|
Channel scanner number of channels
MS2089A-0027 |
1 to 60 |
|---|---|
|
Channel scanner measurement range
MS2089A-0027 |
–160 dBm to +30 dBm |
|
GNSS supported satellite systems
Option 31 |
GNSS (includes combinations of GPS, GLONASS, Galileo, BeiDou)
Requires GNSS antenna, sold separately |
|
GNSS connector
Option 31 |
SMA, female |
| Display | IK08 10-inch touch screen |
|---|---|
|
Weight
MS2085A |
less than 7 lb |
|
Weight
MS2089A |
less than 8.5 lb |
| Battery life (cable and antenna analyzer) | Up to 9 hours |
| Ingress protection |
IP52
When installed in soft carrying case |
| Explosive atmosphere | MIL-PRF-28800F Section 4.5.6.3 compliant |
| EMC Directive | 2014/30/EU |
|---|---|
| Low Voltage Directive | 2014/35/EU |
| RoHS Directive | 2011/65/EU + 2015/863 |
| Electromagnetic compatibility | EN 61326-1:2013 |
| Emissions | EN 55011:2009 +A1:2010 Group 1 Class A |
| Electrical safety | IEC 61010-1:2010+AMD1:2016 |
Applications
- Broadcast transmitter systems
- Cellular networks
- Distributed antenna systems (DAS)
- Military airframes
- Ship communications
- Satellite monitoring
- Interference analysis
- Installation and maintenance of RF systems
Options & Accessories
| Option | Description |
|---|---|
| MS2085A-0804 | Frequency Option 4 GHz Cable and Antenna Analyzer |
| MS2085A-0806 | Frequency Option 6 GHz Cable and Antenna Analyzer |
| MS2085A-0904 | Frequency Option 4 GHz Vector Network Analyzer |
| MS2085A-0906 | Frequency Option 6 GHz Vector Network Analyzer |
| MS2085A-0002 | Time Domain with Gating |
| MS2085A-0003 | Time Domain Reflection — Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2085A-0006 | Remove Wi-Fi and Bluetooth |
| MS2085A-0007 | Secure Data |
| MS2085A-0015 | Vector Voltmeter |
| MS2085A-0017 | Secure Communication |
| MS2085A-0019 | High Accuracy Power Meter — Requires USB sensor, sold separately. Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2085A-0021 | 2-Port Transmission Measurement |
| MS2085A-0031 | GNSS Receiver — Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2085A-0804-0097 | Accredited Calibration |
| MS2085A-0804-0098 | Standard Calibration |
| MS2085A-0804-0099 | Premium Calibration |
| MS2085A-0806-0097 | Accredited Calibration |
| MS2085A-0806-0098 | Standard Calibration |
| MS2085A-0806-0099 | Premium Calibration |
| MS2089A-0804 | Frequency Option 4 GHz Cable and Antenna Analyzer |
| MS2089A-0806 | Frequency Option 6 GHz Cable and Antenna Analyzer |
| MS2089A-0704 | Frequency Option 4 GHz Spectrum Analyzer |
| MS2089A-0706 | Frequency Option 6 GHz Spectrum Analyzer |
| MS2089A-0904 | Frequency Option 4 GHz Vector Network Analyzer |
| MS2089A-0906 | Frequency Option 6 GHz Vector Network Analyzer |
| MS2089A-0002 | Time Domain with Gating |
| MS2089A-0003 | Time Domain Reflection — Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0006 | Remove Wi-Fi and Bluetooth |
| MS2089A-0007 | Secure Data |
| MS2089A-0015 | Vector Voltmeter |
| MS2089A-0017 | Secure Communication |
| MS2089A-0019 | High Accuracy Power Meter — Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0021 | 2-Port Transmission Measurement — Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0024 | Interference Finder — Option 31 and directional antenna recommended. Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0027 | Channel Scanner — Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0031 | GNSS Receiver — Requires GNSS antenna, sold separately. Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0090 | Gated Sweep — Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0102 | 40 MHz Analysis Bandwidth — Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0126 | IQ Waveform Capture — Includes MX280005A IQ Signal Master base feature set. Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0127 | I/Q Waveform Stream — Includes MX280005A IQ Signal Master base feature set; requires Option 126. Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0128 | Vector Signal Analysis enabled — Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0199 | Real Time Spectrum Analysis — Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0400 | Enable Vision Monitor Software — Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0407 | Enable Vision High-Speed Port Scanner — Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0431 | Coverage Mapping — Requires Option 31. Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0444 | EMF Measurement Option — Requires Anritsu isotropic antenna, sold separately. Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0509 | AM/FM Modulation Measurement — Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0871 | WCDMA FDD Measurements — Requires Option 31. Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0883 | LTE FDD/TDD DEMOD — Requires Option 31. Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0888 | 5G NR Downlink Measurements — Requires Option 31. Also offered as a 90-day time-limited option by ordering as -9xxx |
| MS2089A-0704-0020 | Tracking Generator |
| MS2089A-0706-0020 | Tracking Generator |
| MS2089A-0704-0097 | Accredited Calibration |
| MS2089A-0704-0098 | Standard Calibration |
| MS2089A-0704-0099 | Premium Calibration |
| MS2089A-0706-0097 | Accredited Calibration |
| MS2089A-0706-0098 | Standard Calibration |
| MS2089A-0706-0099 | Premium Calibration |