OneExpert HFC ONXF-720-BB-65-204-IPX DOCSIS 3.1 and Fiber Service Tester with Broadband Power Meter
OneExpert HFC ONX-720 IPX package with broadband optical power meter, VFL and 65/204 MHz DOCSIS 3.1 module for 10 Gbps service testing.
- Package content
- Broadband Optical Power Meter, VFL, OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck, ONX-CATV-D31-S-6520-1212 module (65/204 MHz D3.1), ONX-720 IPX Package, Protective Fitted Case, Cat6A jumper M-F and M-M
- Broadband Optical Power Meter
- Standard
- Optical Loss Mode (Set/clear Ref with Delta)
- Optional
- Visual Fault Locator (1 mW)
- Standard
Overview
The ONXF-720-BB-65-204-IPX is a new-unit package of the VIAVI OneExpert HFC (ONX-720/730) handheld tester. It combines an ONX-720 mainframe with the IPX software package, a broadband optical power meter, a visual fault locator (VFL) and the ONX-CATV-D31-S-6520-1212 DOCSIS 3.1 sweep-ready module with 65/204 MHz upstream and 1.2 GHz downstream.
The OneExpert HFC validates DOCSIS, Ethernet, PON and WiFi 7 connections at throughput up to 10 Gbps. The package includes OneCheck Ethernet, OneCheck WiFi and 10G VIAVI SpeedCheck as standard. VIAVI Test Process Automation (TPA) provides one-button OneCheck workflows with pass/fail results and geo-tagged saved results.
Optical testing
The broadband power meter covers 800 to 1650 nm with eight calibrated wavelengths and a UPP 2.5 mm connection. A 650 nm VFL is built in, and USB fiber inspection scopes such as the P5000i and FiberChek Probe are supported, with automatic analysis. Optical loss mode is available as an option.
DOCSIS and RF
The ONX-720/730 keeps the RF and DOCSIS test capability of the ONX-620/630, including support for existing RF modules. It provides downstream analysis, including OFDM signal metrics and profile analysis, plus upstream ingress spectrum scanning from 0.5 to 204 MHz.
Design
The unit is IP54-rated, drop-tested and modular, with an upgrade path to 25G/50G PON and DOCSIS 4.0. Integrated GPS, StrataSync and the VIAVI Mobile Tech app are supported. A field-replaceable 96 W/hr battery is rated for multi-day use.
Key Features
- Broadband optical power meter, 800…1650 nm, InGaAs
- Built-in visual fault locator (1 mW, 650 nm)
- ONX-CATV-D31-S-6520-1212 DOCSIS 3.1 module, 65/204 MHz upstream, 1.2/1.2 GHz downstream
- ONX-720 IPX software package
- OneCheck Ethernet and OneCheck WiFi included
- VIAVI SpeedCheck to 5 Gbps and 10 Gbps included
- 10GBase-T RJ-45 Ethernet testing from 100M to 10G
- WiFi 7 2x2 testing on 2.4, 5 and 6 GHz bands
- Unified OneCheck workflow with automated pass/fail and geo-tagged saved results
- Fiber scope support with auto analysis and defect detection
- Smart Access Anywhere remote coaching via PC or mobile connection (optional)
- IP54 rated, drop-tested, modular design
- Upgrade path to 25G/50G PON and DOCSIS 4.0
- Integrated GPS, StrataSync and mobile app support
- Field-replaceable 96 W/hr Li-Ion battery for multi-day use
Specifications
| Package content | Broadband Optical Power Meter, VFL, OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck, ONX-CATV-D31-S-6520-1212 module (65/204 MHz D3.1), ONX-720 IPX Package, Protective Fitted Case, Cat6A jumper M-F and M-M |
|---|---|
| Broadband Optical Power Meter | Standard |
| Optical Loss Mode (Set/clear Ref with Delta) | Optional |
| Visual Fault Locator (1 mW) | Standard |
| OneCheck WiFi7 / OneCheck Ethernet | Standard |
| VIAVI SpeedCheck – 5 Gbps / 10 Gbps | Standard |
| Optical Ethernet Testing over SFP+, OneCheck PON w/Emulation, Ookla Speedtest, TrueSpeed, iPerf, Smart Access Anywhere | Optional |
| HomeTDR, Home Leakage Test, Return Signal Generator w/Loopback, Ingress Expert | Optional |
| PON Selective Optical Power Meter, TruePON, Reverse Sweepless Sweep, QAM Video MPEG Verification, Field View w/RSG | N/A |
| Standard | IEEE 802.3 100M, 1G, 2.5G, 5G, and 10G Ethernet |
|---|---|
| Test Results | Ethernet Frames, IP Connectivity, Ping, Trace route, Web Connectivity, Speed Test up to 10 Gbps |
| 10GBase-T RJ-45 Electrical | 100M, 1G, 2.5G, 5G, 10G |
| SFP+ Optical Ethernet |
1G, 10G (SFP dependent)
Optional
|
| SFP+ Electrical Ethernet |
100M, 1G, 2.5G, 5G, 10G
Optional
|
| OneCheck WiFi (Connected Mode) | WiFi - 7 2x2 (802.11 a/b/g/n/ac/ax/be) 2.4, 5, 6 GHz bands |
|---|---|
| Test Results | Signal strength (RSSI), Standard, Width, Max Router PHY Rate, IP/Web connectivity, Throughput Tests (SpeedCheck, Ookla Speedtest, iPerf) |
| VIAVI SpeedCheck | 5 Gbps, 10 Gbps |
|---|---|
| Ookla Speedtest |
5 Gbps, 10 Gbps
Optional
|
| VIAVI TrueSpeed (RFC-6349) |
5 Gbps, 10 Gbps
Optional
|
| iPerf client |
5 Gbps, 10 Gbps
Optional
|
| Test Results | Delay, Upstream and Downstream Bit Rates |
| Communication Interface | Bluetooth v5.0, BLE 2.0 |
|---|---|
| Smart Device Support |
VIAVI Mobile Tech app, Android 8 or newer, iOS 12 or newer
Recommendation
|
| USB Optical Fiber Scope | P5000i, FiberChek Probe |
|---|---|
| Results for Zone Defects / Scratches | Pass/Fail |
| Low Mag Field-of-View (FOV) | Horizontal 740 μm, Vertical 550 μm |
| High Mag Field-of-View (FOV) | Horizontal 370 μm, Vertical 275 μm |
| Particle Size Detection | <1 μm |
| Power Source | USB port |
| Photo Diode | InGaAs |
|---|---|
| Spectral Range | Broadband (800…1650 nm) |
| Wavelength Setting | 850, 980, 1310, 1490, 1550, 1577, 1625, 1650 nm; Custom 800…1650 nm, step size 1 nm |
| Resolution | 0.01 dB, 0.001 μW |
| Measurement Range for Power Level | -65…+10 dBm |
| Max. Power Level | +16 dBm |
| Measurement Uncertainty |
±0.2 dB/±5% (intrinsic)
Under reference conditions: -11 dBm (CW), 1310 nm ±1 nm, 23 °C ±3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9 µm core, 8° APC), when used with SC/PC connectors
|
| Number of Calibrated Wavelengths | 8 (850, 980, 1310, 1490, 1550, 1577, 1625, 1650 nm) |
| Tone Detection |
270 Hz, 330 Hz, 1 kHz, 2 kHz
Future optional capability; received optical power level ≥ -50 dBm; when used with VIAVI Light Source and received optical power level > -50 dBm
|
| Connection | UPP 2.5 mm |
| Fiber Compatibility | Single-mode, Multimode |
|---|---|
| Wavelength | 650 nm (visible) |
| Output Modes | Continuous and flashing |
| Connector Interface | Universal 2.5 mm (fixed) |
| Output Power | 1 mW |
| Laser Safety Rating | Class 2 |
| Range (maximum) |
7 km
VFL range depends on many factors, including fiber quality/loss
|
| Size |
5.0 x 11.1 x 4.25 in (W x L x H)
ONX-720 and ONX-730 with RF Module
|
|---|---|
| Weight |
3.15 kg (6.9 lb)
With RF Module, without protective case
|
| Operating Temperature Range | Non-Charging: -10°C to 50°C; Battery Charging: 0°C to 40°C |
| Storage Temperature Range | -20°C to 60°C |
| Operating Humidity Range | 10% to 90% RH, non-condensing |
| For Indoor/Outdoor Use | IP54 light rain (0.5 in/hr; 1.27 cm/hr) |
| Drop Rating | 1 m (3.3 ft) onto concrete |
| Operating Altitude | 4000 m max |
| Pollution | 2° |
| RF immunity |
8.5 V/m
For CATV measurements
|
| USB Host Port(s) | USB-C, USB-A (USB 3.0) |
| DC Input Power | 12 V@5 A |
|---|---|
| DC Charge Port | 2.5 mm barrel |
| Battery | 96 W/hr Li-Ion rechargeable battery, Field replaceable |
| Battery Charge Time | 4 Hrs (90%) 6-8 Hrs 100% (AC charger) |
| Battery Life |
3-5 day typical usage for installation technicians
10 installs a day
|
| RF Module | ONX-CATV-D31-S-6520-1212 OneExpert CATV-D3.1 Sweep Ready Module 65/204 MHz 1.2/1.2 GHz |
|---|---|
| Frequency Range | 0.5 to 1,218 MHz |
| Frequency Accuracy |
±10 ppm
Typical @25°C
|
| Diplexer 65 MHz |
upstream 4-65 MHz; downstream 85-1,218 MHz
Diplexer return path options may not be available on all units
|
| Diplexer 204 MHz |
upstream 4-204 MHz; downstream 258-1,218 MHz
Diplexer return path options may not be available on all units
|
| MoCA filter | All models have MoCA triplexer to filter out MoCA signals below the highest downstream frequency |
| RF connectors | RF(2) F connectors replaceable |
| Port 2 | Upstream 0.5–204 MHz and TDR |
| Max Input Power | 60 dBmV total integrated power |
|---|---|
| Operation on Powered TAP | Operate with up to 90 VAC/DC on input port |
| Return Loss | >9 dB |
| Auto Channel Plan Builder | Auto detection of channels (analog, digital, QAM, OFDM) |
| Calibrated Power Levels |
-20 dBmV to +50 dBmV
Downstream digital channel analysis
|
| Level Accuracy | ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C |
| Modulation(s) | 64, 128, and 256 QAM, OFDM |
| OFDM Channels | 24-192 MHz wide − up to 3 active OFDM channels |
| Profile Analysis | Profiles A, B, C, D, NCP, and PLC (more profiles as implemented) |
| MER Specified range |
21 to 40 dB, 64 QAM; 28 to 40 dB, 256 QAM; 16 to 44 dB, OFDM
At −5 to +20 dBmV; MER range declines as input levels decrease
|
| Minimum Lock Level | −15 dBmV |
| BER — Channel Check and DOCSIS Check mode | Down to 1E-9 (pre and post FEC) |
| Ingress Spectrum Scan | 0.5–204 MHz, calibrated range 4-204 MHz |
|---|---|
| Sensitivity | −45 dBmV |
| RBW | 300 kHz |
| Min Detectable Level Upstream | −55 dBmV |
| Dynamic Range | 50 dB |
| Max Total Integrated Power | 55 dBmV, 4–10 MHz, 60 dBmV, 10 to 204 MHz |
| Accuracy |
±2 dB
Typical at 25°C
|
| Sampling Rate | Hyper Spectrum FFT Gapless technology - no missed samples, spans 0.5 to 110 MHz, 110 to 160 MHz, and 160 to 204 MHz |
| Return Loss | >9.5 dB |
| Forward Sweep Telemetry Frequency |
Diplexer dependent 50-1,218 MHz
Input port: Port 1; compatibility SCU-1800
|
|---|---|
| Reverse Sweep Output Transmit Port | Port 1 or Port 2 (user selectable) |
| Port 1 Sweep Frequency Range | Diplexer dependent 5-42/5-65/5-85/5-204 MHz |
| Port 2 Sweep Frequency Range | 5-204 MHz |
| Reverse Sweep Compatibility | SCU-1800 or DAA/RPHY via XperTRAK |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- DOCSIS service activation
- Multi-gig residential service turn-up
- Small business service testing
- Ethernet throughput validation
- WiFi 7 service delivery testing
- Optical power level verification
- Fiber fault location
- Upstream ingress troubleshooting
- Cable network installation testing
Included
- ONX-CATV-D31-S-6520-1212 module (65/204 MHz D3.1)
- Broadband Optical Power Meter
- VFL
- ONX-720 IPX Package
- OneCheck Ethernet
- OneCheck WiFi
- 10G SpeedCheck
- Protective Fitted Case
- Cat6A jumper M-F and M-M
Options & Accessories
| Option | Description |
|---|---|
| ONXF-SW-SFP-ETH | Enable SFP+ port for Optical Ethernet testing over VIAVI supported SFP's |
| ONXF-SW-OPTICAL-LOSS | Optical Loss test mode option to save reference and calculate loss |
| ONXF-SW-OC-PON | OneCheck PON – PON testing via GPON/XGSPON SFP+ |
| ONXF-SW-OC-GPON-EMUL | GPON Emulation for live service testing on GPON network |
| ONXF-SW-OC-XGSPON-EMUL | GPON Emulation for live service testing on GPON network |
| ONX-SMART-ACCESS | Smart Access Anywhere |
| ONXF-SW-OOKLA-SPD-5G-1Y | ONX Ookla Speedtest to 5 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G-3Y | ONX Ookla Speedtest to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G-5Y | ONX Ookla Speedtest to 5 Gbps 5 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G | ONX Ookla Speedtest to 5 Gbps |
| ONXF-SW-OOKLA-SPD-10G-1Y | ONX Ookla Speedtest to 10 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G-3Y | ONX Ookla Speedtest to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G-5Y | ONX Ookla Speedtest to 10 Gbps 5 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G | ONX Ookla Speedtest to 10 Gbps |
| ONXF-SW-TRUESPEED-5G-1Y | ONX TrueSpeed to 5 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-5G-3Y | ONX TrueSpeed to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-5G | ONX TrueSpeed to 5 Gbps permanent License |
| ONXF-SW-TRUESPEED-10G-1Y | ONX TrueSpeed to 10 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-10G-3Y | ONX TrueSpeed to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-10G | ONX TrueSpeed to 10 Gbps Permanent License |
| ONXF-SW-IPERF-5G-1Y | ONX iPerf test to 5 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-5G-3Y | ONX iPerf test to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-5G | ONX iPerf test to 5 Gbps Permanent License |
| ONXF-SW-IPERF-10G-1Y | ONX iPerf test to 10 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-10G-3Y | ONX iPerf test to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-10G | ONX iPerf test to 10 Gbps permanent License |
| ONX-CATV-SW-HL-LKG | Home Leakage Software Option |
| ONX-CATV-SW-HOMETDR | Home TDR Software Option |
| ONX-CATV-SW-RSG-LOOP | Return Signal Generator with Loopback Option |
| ONX-CATV-SW-INGRESS-EXP | Ingress Expert Option for ONX 720's |
| ONX-CATV-SW-RP-SNR-OCE | Return Path SNR in OneCheck Expert - OneExpert CATV |
| ONX-CATV-FWD-SWEEP | Active Forward Sweep |
| ONX-CATV-REV-SWEEP | Active Reverse Sweep |
| NSC-SFP-GPON | GPON SFP for GPON emulation |
| NSC-SFP-XGSPON | XGSPON SFP+ for XGSPON emulation |
| NSC-SFP-850-1G-10G | Optical Ethernet SFP + 850 nm SR 1G and 10G |
| NSC-SFP-1310-1G-10G | Optical Ethernet SFP + 1310 nm LR 1G and 10G |
| NSC-SFP-1550-1G-10G | Optical Ethernet SFP + 1550 nm ER 1G and 10G |
| AC-CHARGER | Replacement AC charger (no power cord) |
| AC-CAR-CHARGER | Car Charger |
| CC-034601 | Large Carrying Case |
| 1019-00-1366 | Strand Hook |
| ONXF-HANDSTRAP | Handstrap for use on unit without a case |
| ONXF-HFC-BATT-96WHR | Replacement 96 W/Hr Battery |
| ONXF-DISPLAY-PROTECTOR-5P | Replacement screen protector (5 pack) |
| ONXF-ETH-ADAPT-M-F | Ethernet Cat6a M-F adapter 0.5 m |
| NSC-ETHERNET-CABLE | Ethernet Cat6a M-M Patch Cable |
| ONXF-HFC-CASE | Fitted protective case for ONX-720/730 with DOCSIS 3.1 |