Luna os4200 series FBG stainless steel temperature probes, including the os4280
Luna / os4200 / Temperature
os4280

Luna os4280 Ruggedized FBG Temperature Probe with Thermocouple Head

Ruggedized stainless steel fiber Bragg grating temperature probe with aluminum thermocouple head and armored cable, member of the os4200 series.

Operating temperature range
-40 to 120°C, -70 to 275°C available
Temperature sensitivity
~10pm/ºC (±1.7pm/ ºC)
Cable temperature range
-40 to 250° C (FC/APC Connectors: -40 to 80°C)
Response time
8.5 Seconds
Datasheet

Overview

The os4280 is the ruggedized version of the Luna os4200 series of temperature probes, which are based on fiber Bragg grating (FBG) technology. The probe is a sealed 316 stainless steel tube fitted with an aluminum thermocouple head and armored cable, so it can be installed and handled in the same way as a conventional thermocouple. No epoxies hold the fiber to the tube, which supports long-term stability by design.

Compared with conventional thermocouples, os4200 series probes offer similar sensitivity and accuracy, a wider operating range, no calibration and freedom from EMI noise. The probes are qualified for use in harsh environments.

The sensor can be used alone or in series at the end of an FBG sensor array, which keeps installation and cabling simpler than for comparable electronic gage networks. Each sensor ships with a Sensor Information Sheet listing the calibration coefficients needed to convert wavelength to temperature, and the ENLIGHT Sensing Software includes a utility to calculate, record, display and transmit data for large sensor networks.

Key Features

  • Ruggedized probe with aluminum thermocouple head
  • Armored fiber cable
  • Calibrated for high absolute accuracy
  • Capable of measuring from -70 to +275 degrees C
  • Qualified to the same rigorous standards used for comparable electronic gages
  • Fast, simple, repeatable installation
  • Connector protection fittings available for harsh environments
  • Double-ended design supports multiplexing of many sensors on one fiber
  • No epoxies holding the fiber to the tube
  • Included in ENLIGHT's sensor templates for optical to mechanical conversions

Specifications

Thermal Properties
Operating temperature range -40 to 120°C, -70 to 275°C available
Page: Standard: -40 to 120 °C; Extended range: -70 to 275 °C
Temperature sensitivity ~10pm/ºC (±1.7pm/ ºC)
Cable temperature range -40 to 250° C (FC/APC Connectors: -40 to 80°C)
Response time
os4280
8.5 Seconds
Time to reach 63% of total temperature drop in water (100°C)
Standard calibration (included), long term accuracy 1.0°C
Based on 275°C soak for 1,100 hours
Standard calibration (included), short-term accuracy 0.6°C
Typical
Premium calibration (optional), long term accuracy 0.5°C
Absolute accuracy of sensor is dependent on capability of interrogation instrument
Premium calibration (optional), short-term accuracy 0.2°C
Typical
Physical Properties
Probe (diameter x length)
os4280
6.35 x 137.9 mm
Weight (including cable)
os4280
411 g
Housing material
os4280
316 Probe w/Aluminum Thermocouple Head
Fastening method
os4280
1/4" Compression Fitting
Cable type 0.9 mm Fiberglass Braid / 3mm Armored Cable
Series datasheet lists both cable types; per-model assignment not explicit in extracted table
Cable length 1 m (± 10 cm), each end
Fiber type SMF28-Compatible
Cable bend radius ≥ 17 mm
Optical Properties
Peak reflectivity (Rmax) > 70%
FWHM (-3 dB point) 0.25 nm (± .05 nm)
Isolation > 15 dB (@ ± 0.4 nm around center wavelength)
Wavelengths Standard - 1460 to 1620 nm in 4 nm intervals
(+/- 1nm)
Ordering Information
Part number format os42aa-wwww-1xx-y-zz
aa = 80 for Ruggetized Probe Thermocouple Head; example: os4230-1560-1FC-S-SR

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Process temperature monitoring
  • SHM for civil and geotechnical structures
  • SHM for energy systems
  • Structures (bridges, dams, tunnels, mines, buildings, oil platforms)
  • Energy (wind turbines, oil wells, pipelines, nuclear reactors, generators)
  • Transportation (railways, trains, roadways, specialty vehicles, cranes)
  • Marine vessels (hull, deck, cargo containers)
  • Aerospace (airframes, composite structures, wind tunnels, static and dynamic tests)

Included

  • Sensor Information Sheet with calibration coefficients
  • Standard calibration

Options & Accessories

Option Description
UT Unterminated — Termination type
FC FC/APC Connector — Termination type
PF FC/APC Connector with Protection Fitting — Termination type
S Standard calibration — Calibration method (included)
P Premium calibration — Calibration method (optional)
SR Standard Range, -40 to 120°C — Calibration range
HR High Range, 20 to 275°C — Calibration range
ER Extended Range, -70 to 275°C — Calibration range

Documents & Resources