Luna os4200 series FBG stainless steel temperature probes
Luna / os4200 / Temperature
os4230

Luna os4230 Ruggedized Metallic FBG Temperature Probe

Ruggedized stainless steel fiber Bragg grating temperature probe with armored cable and a 1.5 s response time.

Operating temperature range
-40 to 120°C, -70 to 275°C available
Temperature sensitivity
~10pm/ºC (±1.7pm/ ºC)
Cable temperature range
-40 to 250° C (FC/APC Connectors: -40 to 80°C)
Response time
1.5 Seconds
Datasheet

Overview

The Luna os4230 is the ruggedized metallic probe version of the os4200 Temperature Probe series. It is a sealed stainless steel tube based on fiber Bragg grating (FBG) technology, designed so that handling is easy and sensor installation is fast and repeatable. No epoxies hold the fiber to the tube, so long-term stability is ensured by design.

In side-by-side comparisons with conventional thermocouples, the os4200 probes are equally sensitive and accurate while providing a wider operating range, no EMI noise and qualification for use in harsh environments. The os4230 uses a 316 stainless steel probe with 3 mm armored cable, operating much like a conventional thermocouple package, and offers optional connectors with protection fittings.

The sensor can be used alone or in series at the end of an FBG sensor array. Installation and cabling for such arrays is less expensive and cumbersome than for comparable electronic gage networks.

Each sensor is supplied with a Sensor Information Sheet listing the calibration coefficients needed to convert wavelength information into temperature. The ENLIGHT Sensing Software provides a utility to calculate and then record, display and transmit data for large networks of sensors.

Key Features

  • Calibrated for high absolute accuracy
  • Fast response time
  • Capable of measuring from -70 to +275 degrees C
  • Rugged sensor packages, qualified to same rigorous standards applied to electronic gages
  • Double-ended design supports multiplexing of many sensors on one fiber
  • Armored fiber cable weldable package and rugged sensor package
  • Connector protection fittings available for harsh environments
  • Fast, simple, repeatable installation
  • Included in ENLIGHT’s sensor templates for quick and easy optical to mechanical conversions

Specifications

Thermal Properties
Operating temperature range -40 to 120°C, -70 to 275°C available
Standard: -40 to 120 °C; Extended range: -70 to 275 °C
Temperature sensitivity ~10pm/ºC (±1.7pm/ ºC)
Cable temperature range -40 to 250° C (FC/APC Connectors: -40 to 80°C)
Response time
os4230
1.5 Seconds
Time to reach 63% of total temperature drop in water (100°C)
Standard calibration (included) long term accuracy 1.0°C
Based on 275°C soak for 1,100 hours
Standard calibration (included) short-term accuracy 0.6°C
Typical
Premium calibration (optional) long term accuracy 0.5°C
Absolute accuracy of sensor is dependent on capability of interrogation instrument
Premium calibration (optional) short-term accuracy 0.2°C
Typical
Physical Properties
Probe (diameter x length)
os4230
4.76 x 142.9 mm
Weight (including cable)
os4230
30g
Housing material
os4230
316 Probe w/ Armored Cable
Cable length 1 m (± 10 cm), each end
Fiber type SMF28-Compatible
Cable bend radius ≥ 17 mm
Cable type
os4230
3mm Armored Cable
FC/APC connector
os4230
Both Connector and Protection Fittings Optional
Fastening method
os4230
3/16" Compression Fitting
Optical Properties
Peak reflectivity (Rmax) > 70%
FWHM (-3 dB point) 0.25 nm (± .05 nm)
Isolation > 15 dB
@ ± 0.4 nm around center wavelength
Wavelengths Standard - 1460 to 1620 nm in 4 nm intervals
+/- 1nm
Ordering Information
Part number format os42aa-wwww-1xx-y-zz
aa = mode (30 = Ruggetized Metallic Probe), wwww = wavelength, 1xx = cable length and connector, y = calibration method, zz = calibration range
Ordering example
os4230
os4230-1560-1FC-S-SR

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Process temperature monitoring
  • SHM for civil and geotechnical structures
  • SHM for energy systems
  • Structures (bridges, dams, tunnels, mines, buildings, oil platforms)
  • Energy (wind turbines, oil wells, pipelines, nuclear reactors, generators)
  • Transportation (railways, trains, roadways, specialty vehicles, cranes)
  • Marine vessels (hull, deck, cargo containers)
  • Aerospace (airframes, composite structures, wind tunnels, static and dynamic tests)

Included

  • Sensor Information Sheet with calibration coefficients
  • Standard calibration

Options & Accessories

Option Description
UT Unterminated — Termination type
FC FC/APC Connector — Termination type
PF FC/APC Connector with Protection Fitting — Termination type
S Standard calibration — 1.0°C long term accuracy; 0.6°C short-term accuracy, typical (included)
P Premium calibration — 0.5°C long term accuracy; 0.2°C short-term accuracy, typical (optional)
SR Standard Range calibration — -40 to 120°C
HR High Range calibration — 20 to 275°C
ER Extended Range calibration — -70 to 275°C

Documents & Resources