Anritsu ML2438A dual input CW power meter, front view
ML2438A

ML2430A Series ML2438A Dual Input CW Power Meter

Dual-input CW power meter from the ML2430A series covering 100 kHz to 50 GHz (sensor dependent) with up to 90 dB dynamic range per sensor.

Number of Input Signals
2
Frequency Range
100 kHz to 50 GHz
Dynamic Range (Continuous or Peak)
–70 to +20 dBm
Nominal Video BW
100 kHz
Datasheet

Overview

The Anritsu ML2438A is the dual-input model of the ML2430A series of CW power meters. It combines thermal-meter accuracy, diode-meter speed and the display graphics of a peak power meter in one instrument, achieving 90 dB dynamic range with a single sensor. A graphics display is included as a standard feature.

The two independent signal channels allow gain and output power of an amplifier to be measured simultaneously without multiplexing, and the dual inputs can also be used for return loss measurements under operating conditions. Each display channel can use any combination of the sensor inputs, and results can be shown as a numerical readout or as a graph profile.

Field use

The ruggedized polycarbonate chassis has no vent holes, making the meter splash resistant, and an optional front panel cover and soft case add further protection. An optional NiMH battery supports field service work.

Measurement aids and connectivity

MA24xx series sensors store calibration factor data in internal EEPROMs so the meter corrects readings automatically. An offset table of attenuation versus frequency compensates for attenuators, couplers, cables and limiters in the test path. A rear-panel BNC input measures voltage or accepts a V/GHz signal for automated calibration factor correction. The meter is controlled via GPIB, with emulation of other power meter command sets, and RS232, and the free PowerSuite software displays and archives measurement traces on a PC.

Key Features

  • Two independent input channels
  • 90 dB dynamic range with a single sensor
  • Fast thermal sensors
  • GPIB speed
  • GPIB emulation
  • Triggering controls
  • Burst profile graphics display
  • Power vs. time graphics display
  • Parallel printer connector
  • Sensor EEPROM calibration factor storage with automatic correction
  • Offset table for path loss correction
  • Softkey menu control with numerical keypad
  • Optional NiMH smart battery
  • High speed voltage measurement via rear panel BNC
  • Remote monitoring with modem dial-out when a limit threshold is exceeded
  • Secure mode wipes non-volatile memory on power up
  • Rugged, splash-resistant polycarbonate chassis
  • Free PowerSuite PC software via GPIB or RS232

Specifications

Measurement
Number of Input Signals 2
Frequency Range 100 kHz to 50 GHz
Sensor dependent. The product page summary lists 100 kHz — 65 GHz; datasheet value used.
Dynamic Range (Continuous or Peak) –70 to +20 dBm
Dependent on sensor, external coupler, or attenuator
Nominal Video BW 100 kHz
Profile mode
Sampling Rate 31.25 kS/s
Product page states the meter samples at more than 35K per second; datasheet value used.
Instrumentation Accuracy, CW Mode < 0.5% (± 0.02 dB absolute Accuracy, ± 0.04 dB Relative Accuracy)
Instrumentation Accuracy, Pulse/Modulated Mode < 0.8%
Nominal range 7, 8
Averaging Type Auto (Moving), Manual (Moving, Repeat)
Averaging Range 1 to 512
Low-level Averaging Low, Medium, and High settings
Apply post average low-pass filter to improve visibility at high display resolution
Amplifier Range Dynamic range covered by five overlapping amplifier ranges: R1, R2, R3, R4, and R5
Universal Sensor MA2481/82D ranges 1 to 6
Range Hold Auto or Manual (current range or selectable 1 through 5)
Voltage Measurement Range 0.00 to 20.00 V nominal
Source Sweep Single channel power sweep or frequency sweep
Peaking Meter ± 5 dB range
CW (Readout mode) only
Display
Display Monochrome LCD, with backlight and adjustable contrast
Display Resolution in Readout Mode 0.1 dB to 0.001 dB
Linear power units, 3 to 6 digits, 1 to 3 digits selectable to right of decimal, nW to W; Voltage, 1 to 2 digits selectable to right of decimal
Display Resolution in Profile Mode 0.01 dB
Time Measurement Resolution 200 pixels display resolution
Profile and P vs. T modes; for a 1 ms Profile window, cursor resolution on the display is 5 µs
Measurement Display Readout (Numerical) 2
Measurement Display Profile (Graph) Power vs. Time graphic of readout data or Profile of Peak power for analysis of repetitive pulse or transient waveforms
Measurement Hold Hold, Max, Min
Display Units Watt, %, Volts, dBm, dB, dBµV, dBmV, dBr
Display Range –199.99 dB to +199.99 dB
Offset Range –199.99 dB to +199.99 dB
Fixed value or frequency dependent table
Measurement Gates 1
Markers 2
Limit Lines Fixed value high and low limits with audible, rear panel TTL output, and/or visible Pass/Fail alarm indication
Failure indication can latch for transient failure detection
Triggering
Source Internal, External (TTL or RF Blanking), GPIB, Manual, or Continuous
Internal Trigger Dynamic Range –15 dBm to +20 dBm
All diode sensors, selectable to –25 dBm
Internal Trigger Level Accuracy 1 dB
Typical
Internal Trigger Settable Resolution 0.1 dB
Trigger Delay Range 0 ms to 999 ms
Trigger Delay Settable Resolution 0.5% of display period or 100 ns
External Trigger Range TTL rising or falling edge (BNC input)
Trigger/Display Capture Range Profile mode: 10 ms to 7 s; P v T mode: 1 m to 24 hrs
Reference Calibrator
Reference Calibrator Power 1 mW
Power Accuracy ± 1.2% per year
Traceable to National Standards
Frequency 50 MHz (nominal)
Frequency Accuracy < 1%
VSWR < 1.12
Connector Type N female
Nominal input impedance is 50 ohms
Interfaces
GPIB (IEEE–488.2, IEC–625) > 600 readings/second (per input channel)
Emulation of Anritsu ML4803, Agilent 436, 437, and 438
RS232 Supports software download, instrument control, and modem dial-out
1200, 2400, 4800, 9600, 19200, 38400, 57600 Baud rates are supported
Parallel Printer Port Compatible with Deskjet 540 and 340 Models (other 500 Series and 300 Series and later are typically compatible). Canon BJC 80.
Cal Factor Voltage Input (BNC) Input Range: 0 V to 20 V; Resolution: 0.5 mV
Display voltage reading on selected channel, or voltage proportional to frequency for sensor calibration factor compensation
External Trigger (BNC) TTL, maximum frequency of 800 kHz
Analog Output (BNC) Two outputs configurable to Log or Lin; Output Range: –5.0 V to +5.0 V; Resolution: 0.1 mV
AC Modulation Output: Output 1 only; Dwell Output: Output 2 only
Save/Recall 10 storage registers plus RESET default settings
Secure Mode Wipes non-volatile memory on power up when active
Remote Monitoring Yes
Modem compatible
Power
DC Power Requirements 12 to 24 VDC, Reverse protected to –40 V Maximum input 30 V
AC Power Requirements 85 VAC to 240 VAC, 47 Hz to 400 Hz, 40 VA Maximum
Quick Fact Sheet lists 90 to 250 VAC, 47 to 440 Hz; datasheet value used
Battery Option > 6 hr usable with 3000 mAhr (NiMH) battery
Non-Volatile RAM Battery Lithium (10 year life)
Environmental
Operating Temperature 0 °C to 40 °C
Quick Fact Sheet lists 0° to 50 °C; datasheet value used
Storage Temperature –40 °C to 70 °C
Moisture Splash and rain resistant, 95% humidity non-condensing
Operating Elevation 4,600 m
Per W31P4Q-18-007
Environment For indoor use only, Pollution Degree 2
Military Compliance MIL-T-28800F, class 3
Physical
Dimensions 223 mm x 150 mm x 390 mm
Quick Fact Sheet lists 213 mm W x 88 mm H x 390 mm D; datasheet value used
Weight 3 kg
Excluding battery option
Warranty Power meters have a standard 1 year warranty
Quick Fact Sheet states 3-year standard for power meters; datasheet and compliance guide state 1 year

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • CW power measurement
  • Amplifier gain and output power measurement
  • Return loss measurement
  • TDMA and pulsed signal profile display
  • Field service
  • Automated test equipment (ATE) systems
  • Remote power monitoring

Included

  • Power cord for destination country
  • One 1.5 m sensor cord per meter input
  • PowerSuite software
  • Operation Manual (soft copy)
  • Programming Manual (soft copy)
  • Certificate of Calibration

Options & Accessories

Option Description
ML2400A-05 Front Bail Handle
ML2400A-08 Rear Mount Inputs A, B and Reference on ML2438A — Options 6, 7, 8 and 9 are mutually exclusive for any given ML2430A unit
ML2400A-09 Rear Mount Inputs A and B on ML2438A — Options 6, 7, 8 and 9 are mutually exclusive for any given ML2430A unit
2000-1603 NiMH Battery
2000-996-R Desktop Battery Charger with Power Supply
2000-1534-R Desktop Battery Charger (for use in Japan only)
2000-1545 Bulkhead Adapter
10585-00001 Hard Copy Operation and Programming Manuals
10585-00003 Hard Copy Maintenance Manual
ML2400A-98 Calibration to ISO 17025 and/or ANSI/NCSL Z540
ML2400A-99 Premium Calibration
760-209 Hardside Transit Case
D41310 Soft Carry Case with Shoulder Strap
2000-1535 Front Panel Cover
2400-82 Rack Mount, Single Unit — Options 5, 2400-82, and 2400-83 are mutually exclusive
2400-83 Rack Mount, Side-by-Side — Options 5, 2400-82, and 2400-83 are mutually exclusive
2000-1536-R 0.3 m Sensor Cable
2000-1537-R 1.5 m Sensor Cable — Standard sensor cable; peak and pulse sensor performance is specified with this cable
2000-1538-R 3 m Sensor Cable
2000-1539-R 5 m Sensor Cable
2000-1540-R 10 m Sensor Cable
2000-1541-R 30 m Sensor Cable
2000-1542-R 50 m Sensor Cable
2000-1543-R 100 m Sensor Cable
2000-1544 RS-232 Bootload Cable