Anritsu ACCESS Master MT9085 series handheld OTDR front view
MT9085C-057

ACCESS Master MT9085C-057 High Performance 1310/1550/1625 nm Handheld OTDR

High Performance ACCESS Master handheld OTDR with 1310/1550/1625 nm single-mode wavelengths and up to 46 dB dynamic range.

Wavelength
1310/1550/1625 nm ±25 nm
Fiber Type
Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width
3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic Range (HR mode)
46/46/44 dB

Overview

The ACCESS Master MT9085C-057 is the High Performance model of the Anritsu MT9085 series configured with a single-mode OTDR module at 1310, 1550 and 1625 nm. The 1625 nm maintenance wavelength supports macrobend analysis, and the model is aimed at long-haul and ultra-long-haul installation and maintenance (I&M) work.

The MT9085 series is a compact handheld all-in-one tester for optical pulse tests, optical loss and power measurements and optical fiber end-face inspection. It combines an 8-inch color LCD touchscreen with the hard keys and rotary knob used on previous ACCESS Master models, and the pressure-sensitive touchscreen accepts input without removing work gloves.

OTDR measurement

The Fiber Visualizer function displays events such as splices, connectors, PON splitters and the fiber far end as schematic icons with distance, loss and reflectance Pass/Fail results. Two realtime sweep modes (high-speed and high S/N) help locate fiber bends, and multi-pulse measurement supports accurate loss and reflectance measurement between closely spaced events. PON splitter analysis covers up to 1 × 128 branches, and bi-directional analysis averages traces measured from both ends of the fiber.

Loss, power and end-face inspection

A stabilized light source and an optical power meter are built in as standard through the OTDR port; dedicated power meter options add a separate port for optical loss testing (OLTS). A visual fault locator option and the external G0306C Video Inspection Probe extend the unit to fault location and end-face Pass/Fail evaluation per IEC61300-3-35.

Data management

Measurement data can be saved as original files (.sor, .vipi), .csv files, screen captures or PDF reports, and transferred via USB memory, USB cable, WLAN or Ethernet (via USB adapters). The unit can be controlled remotely using a web browser GUI or remote commands, and Scenario Manager Lite runs predefined test procedures without a PC.

Key Features

  • 8-inch LCD touchscreen with visibility in direct sunlight
  • LCD touchscreen, rotary knob and dedicated hard keys for operation
  • Fiber Visualizer function for simple fiber path analysis
  • High-speed and high S/N real-time sweep modes for fast fiber bend location
  • 46-dB dynamic range max. and 0.8 m event dead zone
  • 1625 nm maintenance wavelength for macrobend analysis
  • Identification of each splitter event for up to 1 × 128 branches
  • Built-in stabilized light source and optical power meter as standard
  • Optional visual fault locator and optical power meters
  • Optical fiber end-face inspection with external G0306C Video Inspection Probe
  • Cable Certification Test function with automatic Pass/Fail per IEC/ISO standards
  • Installation Test function for automatic measurement of multiple fibers
  • Bi-directional waveform analysis
  • Optical Communications Check (live fiber detection) and connection check functions
  • Telcordia SR-4731 trace format support
  • 1 GB internal memory for up to 50,000 traces
  • Remote control via web browser GUI and remote commands
  • Password protection function
  • 12-hour battery operation

Specifications

OTDR
Wavelength 1310/1550/1625 nm ±25 nm
25°C, Pulse width: 1 μs
Fiber Type Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic Range (HR mode) 46/46/44 dB
Typical, subtract 1 dB for guarantee. Pulse width 20 μs (1310/1550 nm) at distance range 100 km, averaging 180 sec., SNR = 1, 25°C
Dynamic Range (ER mode) 25/25/23 dB
Pulse width: 100 ns (ER Mode), Distance range: 100 km, Averaging: 180 sec., SNR = 1, 25°C
Dead Zone (Fresnel) ≤1 m, 0.8 m (typ.)
IOR = 1.500000; Pulse width: 3 ns, Return loss: 40 dB, 25°C
Dead Zone (Backscatter) ≤3.8/4.3/4.8 m
IOR = 1.500000; Pulse width 10 ns, return loss 55 dB, Deviation ±0.5 dB, 25°C
Laser Safety IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
OTDR Measurement
Distance Range 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km
Single mode
Sampling Points Up to 150,001
Either high density value is selected depending on distance range
Sampling Resolution 0.05 m to 60 m
Reflectance Accuracy ±2 dB
Single mode; when measuring the non-connected end of an approximately 25 km length fiber, Distance range: 50 km, Pulse width: 2 μs
Distance Accuracy ±1 m ±3 × measurement distance × 10-5 ± marker resolution
Excluding IOR uncertainty
Loss Measurement Accuracy (Linearity) ±0.05 dB/dB or ±0.1 dB (whichever is greater)
Vertical Scale 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div
IOR Setting 1.300000 to 1.700000 (0.000001 steps)
Units km, m, kft, ft, mi
Fiber Event Analysis Auto or manual operation, displayed in table format; up to 99 detected events; macrobend detection
User defined Pass/Fail thresholds: events 0.01 to 9.99 dB, reflectance 70.0 to 20.0 dB, fiber end/break 1 to 99 dB
OTDR Trace Format Telcordia universal. SOR, issue 2 (SR-4731)
Real time sweep 0.15 sec.
Resolution: Low Density
Loss modes 2-point loss, dB/km, 2-point LSA, splice loss, ORL
Averaging modes Timed (1 to 3600 s)
Light Source (standard, through OTDR port)
Wavelength Same as OTDR
CW, 25°C
Spectral Width ≤5 nm (1310 nm), ≤10 nm (1550/1625 nm)
CW, 25°C
Wavelength Accuracy ±30 nm
CW, 25°C
Output Power –5 ±1.5 dBm
CW, 25°C
Output Stability ≤0.1 dB
CW, –10°C to 50°C (±1°C) difference between max/min. values over 1 minute, SM fiber 2 m
Modes of Operation CW, 270 Hz, 1 kHz, 2 kHz
Power Meter (standard, through OTDR port)
Maximum Input +10 dBm
Measurement Range –50 to –5 dBm
Accuracy ±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, using Anritsu's reference single mode fiber with FC/UPC connector
Setting Wavelengths 1310, 1550, 1625, 1650 nm
Not available if Option 004, 005 or 007 is ordered
Optional Power Meters
Measurement Range
MT9085C-007
–67 to +6 dBm (CW, 1310 nm)
Peak power, subtract 3 dB for modulated tones
Measurement Range
MT9085C-004
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Measurement Range
MT9085C-005
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Visual Light Source (Option 002)
Central Wavelength
MT9085C-002
650 nm±15 nm (at 25˚C)
Optical Output
MT9085C-002
0 ±3 dBm (CW)
Optical Connector
MT9085C-002
2.5 mm universal
General
Display 8-inch touch screen TFT-Color LCD
Interface USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
Wireless Interface WLAN via USB adapter connected to USB port
Data Storage Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB
Languages English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
Power
Power Supply 12 V(dc), 100 V(ac) to 240 V(ac), Allowable input voltage range: 90 V to 264 V, 50 Hz/60 Hz
Battery Type Lithium ion
Battery Operating Time 12 hours
Telcordia GR-196-CORE Issue 2, September 2010; typical, backlight Low, sweeping halted at 25˚C
Recharge Time <5 hours (power off)
Power Consumption 20 W max (recharging), 4 W standard (low backlight, sweep stopped)
Physical
Dimensions (without Protector) 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches
Mass (without Protector) 1.6 kg without battery, 1.9 kg including battery
Dimensions (with Protector option 010) 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches
Mass (with Protector option 010) 2.6 kg including battery
Environmental
Operating temperature and humidity –10°C to +50°C, <80% (non-condensing)
Storage temperature and humidity –20°C to +60°C, <80% (non-condensing)
Vibration Conforming to MIL-T-28800E Class 3
Ingress Protection Rating IEC60529 IP51
Shock MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off)

Applications

  • Long haul fiber installation and maintenance
  • Ultra-long haul fiber testing
  • Macrobend analysis
  • Core and metro network maintenance
  • Mobile fronthaul and backhaul fiber testing
  • Access network troubleshooting
  • PON-based FTTx measurement
  • Optical loss and power measurement
  • Fiber end-face inspection

Included

  • Z1991A MT9085 Operation Manual (CD)
  • W3974AE MT9085 Series Quick Guide
  • Z1625A AC adapter
  • Line cord
  • Z0921A Battery Pack

Options & Accessories

Option Description
MT9085C-025 FC-APC Connector — Key width 2.0 mm; can only connect APC-type optical fiber
MT9085C-026 SC-APC Connector — Can only connect APC-type optical fiber
MT9085C-037 FC Connector
MT9085C-038 ST Connector
MT9085C-039 DIN47256 Connector
MT9085C-040 SC Connector
MT9085C-002 Visual Fault Locator — Visual light source for locating fiber breaks
MT9085C-004 SMF Optical Power Meter — –50 to +23 dBm
MT9085C-005 SMF High Power Optical Power Meter — –43 to +30 dBm
MT9085C-007 SMF/MMF Optical Power Meter — –67 to +6 dBm
MT9085C-010 Protector — Front Protector B0584A cover supplied with belt as standard
G0306C Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation
Z1632A Battery Charger — Li-ion battery charger
B0582A Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector
B0583A Hard transit case — Dimensions 420 (W) × 330 (H) × 148(D) mm
J1950A USB-Ethernet converter — For remote GUI connection
NETWORKS NETWORKS OTDR analysis software — PC software for waveform analysis and report creation of .sor files

Documents & Resources