ACCESS Master MT9085C-053 High Performance 1310/1550 nm SMF Handheld OTDR
High-performance handheld OTDR with 1310/1550 nm single-mode wavelengths, 46/46 dB dynamic range, built-in light source and power meter.
- Wavelength
- 1310/1550 nm ±25 nm
- Fiber type
- Single Mode (SMF) 10/125 μm ITU-T G.652
- Pulse width
- 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
- Dynamic range (HR mode)
- 46/46 dB
Overview
The ACCESS Master MT9085C-053 is the High Performance 1310/1550 nm single-mode module option of the Anritsu MT9085 series, a compact handheld all-in-one tester for optical pulse (OTDR) tests, optical loss and power measurements, and optical fiber end-face inspection. Anritsu positions the MT9085C models for long-haul and ultra-long-haul applications, and the -053 option as the standard model for installation and maintenance (I&M).
OTDR measurement
The OTDR measures fiber transmission loss and length and detects events such as splices, connectors, splitters and breaks. The Fiber Visualizer function displays events as schematic icons with distance, loss and reflectance Pass/Fail results. Two realtime sweep modes (high-speed and high S/N) help locate fiber bends, and multi-pulse measurement supports event detection with up to 46 dB dynamic range and a 0.8 m event dead zone. PON splitter analysis covers up to 1 × 128 branches.
Operation
The unit combines an 8-inch color LCD touchscreen with a rotary knob and dedicated hard keys from earlier ACCESS Master models. The pressure-sensitive touchscreen accepts input while wearing work gloves. Manual analysis uses two-point or LSA methods with four markers.
Loss, power and end-face inspection
A stabilized light source and a power meter are built in through the OTDR port; optional dedicated power meter ports enable optical loss test set (OLTS) measurements with one tester. An optional visual fault locator and the external G0306C Video Inspection Probe support break location and IEC61300-3-35 end-face Pass/Fail evaluation. Data can be saved as .sor, .csv or PDF reports and transferred via USB, WLAN or Ethernet adapters.
Key Features
- 8-inch LCD touchscreen with visibility in direct sunlight
- LCD touchscreen combined with rotary knob and dedicated hard keys
- Fiber Visualizer function for simple fiber path analysis
- High-speed and high S/N real-time sweep modes for locating fiber bends
- 46 dB dynamic range (typ.) at 1310 and 1550 nm
- 0.8 m event dead zone (typ.)
- Identification of each splitter event and up to 1 × 128 branches
- Built-in stabilized light source and optical power meter as standard
- Optional visual fault locator and dedicated optical power meter ports
- Optical fiber end-face inspection with external G0306C Video Inspection Probe
- Live fiber detection and OTDR connection check
- Bi-directional measurement analysis
- Cable Certification Test function with automatic Pass/Fail to IEC/ISO standards
- Scenario Manager Lite for automated test procedures without a PC
- Telcordia SR-4731 .sor trace format support
- 1 GB internal memory for up to 50,000 traces
- Remote control via web browser GUI or remote commands
- Password protection function
Specifications
| Wavelength |
1310/1550 nm ±25 nm
25°C, Pulse width: 1 μs
|
|---|---|
| Fiber type | Single Mode (SMF) 10/125 μm ITU-T G.652 |
| Pulse width | 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns |
| Dynamic range (HR mode) |
46/46 dB
Typical; subtract 1 dB for guarantee. Pulse width 20 μs, distance range 100 km, averaging 180 sec., SNR = 1, 25°C
|
| Dynamic range (ER mode) |
25/25 dB (Pulse width: 100 ns)
ER Mode, distance range 100 km, averaging 180 sec., SNR = 1, 25°C
|
| Dead zone (Fresnel) |
≤1 m, 0.8 m (typ.)
IOR = 1.500000; pulse width 3 ns, return loss 40 dB, 25°C
|
| Dead zone (Backscatter) |
≤3.8/4.3 m
IOR = 1.500000; pulse width 10 ns, return loss 55 dB, deviation ±0.5 dB, 25°C
|
| Laser safety |
IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
|
| Sampling points |
Up to 150,001
Either high density value is selected depending on distance range
|
| Sampling resolution | 0.05 m to 60 m |
| Distance range (single mode) | 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km |
| Distance accuracy |
±1 m ±3 × measurement distance × 10-5 ± marker resolution
Excluding IOR uncertainty
|
| Loss measurement accuracy (linearity) | ±0.05 dB/dB or ±0.1 dB (whichever is greater) |
| Reflectance accuracy (single mode) |
±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, distance range 50 km, pulse width 2 μs
|
| IOR setting | 1.300000 to 1.700000 (0.000001 steps) |
| Vertical scale | 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div |
| Units | km, m, kft, ft, mi |
| Real time sweep |
0.15 sec.
Resolution: Low Density
|
| OTDR trace format | Telcordia universal. SOR, issue 2 (SR-4731) |
| Loss modes | 2-point loss, dB/km, 2-point LSA, splice loss, ORL |
| Averaging modes | Timed (1 to 3600 s) |
| Operation | Auto or manual operation, displayed in table format |
|---|---|
| Reflective and non-reflective events threshold |
0.01 to 9.99 dB (0.01-dB steps)
User defined Pass/Fail threshold
|
| Reflectance threshold |
70.0 to 20.0 dB (0.1-dB steps)
User defined Pass/Fail threshold
|
| Fiber end/break threshold |
1 to 99 dB (1-dB steps)
User defined Pass/Fail threshold
|
| Number of detected events | up to 99 |
| Wavelength |
Same as OTDR
Stabilized light source through OTDR port; CW, 25°C
|
|---|---|
| Spectral width |
≤5 nm (1310 nm), ≤10 nm (1550 nm)
CW, 25°C
|
| Wavelength accuracy |
±30 nm
CW, 25°C
|
| Output power |
–5 ±1.5 dBm
CW, 25°C
|
| Output stability |
≤0.1 dB
CW, –10°C to 50°C (±1°C) difference between max/min. values over 1 minute, SM fiber 2 m
|
| Modes of operation | CW, 270 Hz, 1 kHz, 2 kHz |
| Maximum input |
+10 dBm
Through OTDR port; not available if Option 004, 005 or 007 is ordered
|
|---|---|
| Measurement range | –50 to –5 dBm |
| Accuracy |
±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, using Anritsu's reference single mode fiber with FC/UPC connector
|
| Setting wavelengths |
1310, 1550, 1625, 1650 nm
Options 053, 055, 057, 063
|
| Features | Store reference, loss table |
|
Measurement range
MT9085C-004
|
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
|
|---|---|
|
Measurement range
MT9085C-005
|
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
|
|
Measurement range
MT9085C-007
|
–67 to +6 dBm (CW, 1310 nm)
–60 to +3 dBm at 850 nm
|
|
Central wavelength
MT9085C-002
|
650 nm±15 nm (at 25˚C) |
|---|---|
|
Optical output
MT9085C-002
|
0 ±3 dBm (CW) |
|
Optical connector
MT9085C-002
|
2.5 mm universal |
|
Laser safety
MT9085C-002
|
IEC 60825-1: 2014 CLASS 3R |
| Display | 8-inch touch screen TFT-Color LCD |
|---|---|
| Interface |
USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
|
| Wireless interface | WLAN via USB adapter connected to USB port |
| Data storage | Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB |
| Languages |
English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
|
| Power supply | 12 V(dc), 100 V(ac) to 240 V(ac), Allowable input voltage range: 90 V to 264 V, 50 Hz/60 Hz |
|---|---|
| Battery type | Lithium ion |
| Battery operating time |
12 hours
Typical, backlight Low, sweeping halted at 25˚C; Telcordia GR-196-CORE Issue 2, September 2010
|
| Recharge time | <5 hours (power off) |
| Power consumption | 20 W max (recharging), 4 W standard (low backlight, sweep stopped) |
| Dimensions (without protector) | 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches |
|---|---|
| Mass (without protector) | 1.6 kg without battery, 1.9 kg including battery |
| Dimensions (with protector, option 010) | 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches |
| Mass (with protector, option 010) | 2.6 kg including battery |
| Operating temperature and humidity | –10°C to +50°C, <80% (non-condensing) |
|---|---|
| Storage temperature and humidity | –20°C to +60°C, <80% (non-condensing) |
| Vibration | Conforming to MIL-T-28800E Class 3 |
| Ingress protection rating | IEC60529 IP51 |
| Shock |
MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off)
Bump: IEC 60068-2-27, JIS C60068-2-27
|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Long-haul fiber installation and maintenance
- Ultra-long-haul fiber testing
- Core and metro network I&M
- Mobile fronthaul and backhaul fiber testing
- PON and FTTx access network troubleshooting
- Drop cable break location
- Optical loss and power measurement
- Fiber connector end-face inspection
Included
- Z1991A MT9085 Operation Manual (CD)
- W3974AE MT9085 Series Quick Guide
- Z1625A AC adapter
- Line cord
- Z0921A Battery Pack
Options & Accessories
| Option | Description |
|---|---|
| MT9085C-025 | FC-APC Connector — Key width 2.0 mm; can only connect APC-type optical fiber |
| MT9085C-026 | SC-APC Connector — Can only connect APC-type optical fiber |
| MT9085C-037 | FC Connector |
| MT9085C-038 | ST Connector |
| MT9085C-040 | SC Connector |
| MT9085C-002 | Visual Fault Locator — Built-in visual light source option |
| MT9085C-004 | SMF Optical Power Meter — –50 to +23 dBm |
| MT9085C-005 | SMF High Power Optical Power Meter — –43 to +30 dBm |
| MT9085C-007 | SMF/MMF Optical Power Meter — –67 to +6 dBm |
| MT9085C-010 | Protector — Front Protector B0584A cover supplied with belt as standard |
| G0306C | Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation |
| W3971AE | MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| W3972AE | MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| B0745A | Softcase |
| B0582A | Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector |
| B0583A | Hard transit case — Dimensions 420 (W) × 330 (H) × 148(D) mm |
| B0549 | Hard carrying case |
| B0584A | Front cover — Option 010 Protector cover only |
| Z0921A | Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh |
| Z1632A | Battery Charger — Li-ion battery charger |
| J1295 | Car plug cord |
| J0617B | Replaceable optical connector (FC-PC) — For OTDR port, For option power meter port (MT9085A/B/C) |
| J0618D | Replaceable optical connector (ST) — For OTDR port, For option power meter port (MT9085A/B/C) |
| J0618F | Replaceable optical connector (HMS-10/A) — For OTDR port, For option power meter port (MT9085A/B/C) |
| J0619B | Replaceable optical connector (SC-PC) — For OTDR port, For option power meter port (MT9085A/B/C) |
| J0739A | Replaceable optical connector (FC-APC) — For OTDR port (MT9085A/B/C) |
| J1697A | Replaceable optical connector (SC-APC) — For OTDR port (MT9085A/B/C) |
| J0057 | Optical adapter FC type — FC-FC connector (JJ adapter) |
| J1335A | MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only) |
| MA9005B-37 | For FC connector — For option power meter port (MT9085A/B/C-005) |
| MA9005B-38 | For ST connector — For option power meter port (MT9085A/B/C-005) |
| MA9005B-40 | For SC connector — For option power meter port (MT9085A/B/C-005) |
| LP-FC | FC-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| LP-ST | ST-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| LP-SC | SC-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| J1530A | SC plug in converter (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC |
| J1531A | SC plug in converter (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC |
| J1532A | FC plug in converter (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC |
| J1533A | FC plug in converter (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC |
| J1534A | LC-SC Plug-in Converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only) |
| J1535A | LC-SC Plug-in Converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only) |
| Z0914A | Ferrule cleaner — 1 pc |
| Z0915A | Replacement reel for ferrule cleaner — 6 pcs for Z0914A |
| Z0284 | Adapter Cleaner — Stick type (200 pcs/set) |
| J1950A | USB-Ethernet converter — For remote GUI connection |
| NETWORKS | NETWORKS PC analysis software — OTDR waveform analysis of .sor files and report creation on Windows PC |