Anritsu ACCESS Master MT9085 Series handheld OTDR, front view
MT9085B-063

ACCESS Master MT9085B-063 Enhanced SMF/MMF Handheld OTDR (1310/1550 nm SM, 850/1300 nm MM)

Handheld all-in-one OTDR for single-mode and multimode fiber at 1310/1550 nm SM and 850/1300 nm MM, with 42/41 dB SM dynamic range

Wavelength
1310/1550 nm ±25 nm, 850/1300 nm ±30 nm
Fiber type
HYBRID (SMF/MMF)
Pulse width (SMF)
3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Pulse width (MMF)
3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000 ns

Overview

The ACCESS Master MT9085B-063 is the all-in-one single-mode and multimode model of the Enhanced (Performance) tier in the Anritsu MT9085 series. It combines optical pulse testing (OTDR) at 1310/1550 nm on single-mode fiber and 850/1300 nm on multimode fiber with optical loss and power measurement and optical fiber end-face inspection in one compact handheld unit. It supports installation and maintenance (I&M) of SMF and MMF links in metro, long-haul and PON-based FTTx networks.

OTDR measurement

The OTDR measures fiber transmission loss and fiber length and detects events such as splices, connectors, splitters and breaks. The Fiber Visualizer function shows events as schematic icons with distance, loss and reflectance Pass/Fail results. Two realtime sweep modes, high-speed and high S/N, help locate fiber bends and check connections while the waveform is monitored. PON splitter analysis covers up to 1 × 128 branches. Manual analysis uses the rotary knob, hard keys and four markers with the two-point or LSA method.

Optical power, loss and end-face inspection

A stabilized light source and an optical power meter are built in as standard and use the OTDR port. Optional dedicated power meter ports add optical loss test set (OLTS) operation, and a visual fault locator is available as an option. With the external G0306C Video Inspection Probe, connector end faces can be inspected on the MT9085 screen and given automatic Pass/Fail evaluation to IEC61300-3-35.

Operation and data handling

The unit has an 8-inch color LCD touchscreen that can be used with work gloves on, together with dedicated hard keys and a rotary knob. Measurement data can be saved as original files (.sor, .vipi), .csv files, screen captures or PDF reports. Data can be transferred over USB, WLAN or Ethernet (through USB adapters), and the unit can be remote-controlled from a web-browser GUI or with remote commands.

Key Features

  • 8-inch LCD touchscreen with easy visibility even in direct sunlight
  • Touchscreen, rotary knob and dedicated hard keys for efficient operation
  • All-in-one SMF/MMF model: 1310/1550 nm SM and 850/1300 nm MM OTDR wavelengths
  • Fiber Visualizer function for simple fiber path analysis with Pass/Fail evaluation
  • High-speed and high S/N realtime sweep modes for fast fiber bend location
  • Identification of each splitter event for up to 1 × 128 branches
  • Built-in stabilized light source and optical power meter as standard
  • Optional visual fault locator and dedicated optical power meter ports
  • Optical fiber end-face inspection with the external G0306C Video Inspection Probe
  • Installation Test function for automatic measurement of multiple fibers
  • Bi-directional waveform analysis
  • Live fiber detection and connection check functions
  • Cable Certification Test function with Pass/Fail evaluation to IEC/ISO standards
  • Scenario Manager Lite for automated test execution without a PC
  • 1 GB internal memory for up to 50,000 traces
  • Telcordia SR-4731 trace format support
  • Password protection function
  • Remote control via web-browser GUI and remote commands

Specifications

OTDR
Wavelength 1310/1550 nm ±25 nm, 850/1300 nm ±30 nm
25°C, Pulse width: 1 μs (all except 850 nm, 1300 nm), 850 nm/1300 nm: 100 ns
Fiber type HYBRID (SMF/MMF)
Single mode: 10/125 μm, ITU-T G.652
Pulse width (SMF) 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Pulse width (MMF) 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000 ns
850 nm: Does not support 1000, 2000, 4000 ns
Dynamic range (1310/1550 nm SM) 42/41 dB
Typical; subtract 1 dB for guarantee. Pulse width 20 μs, distance range 100 km, averaging 180 sec., SNR = 1, 25°C
Dynamic range (850/1300 nm MM) 29/28 dB
Typical; subtract 1 dB for guarantee. Pulse width 500 ns (850 nm), 4 μs (1300 nm), distance range 25 km. With 50 μm/125 μm MM fiber the dynamic range drops by about 3.0 dB
Dead zone (Fresnel) ≤1 m, 0.8 m (typ.)
IOR = 1.500000; pulse width 3 ns, return loss 40 dB, 25°C
Dead zone (Backscatter), SMF ≤5/5.5 m
IOR = 1.500000; pulse width 10 ns, return loss 55 dB, deviation ±0.5 dB, 25°C
Dead zone (Backscatter), MMF ≤4/5 m (3/4 m typ.)
IOR = 1.500000; pulse width 3 ns, return loss 40 dB, deviation ±0.5 dB, 25°C
Laser safety IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
Sampling points Up to 150,001
Either high density value is selected depending on distance range
Sampling resolution 0.05 m to 60 m
Reflectance accuracy (single mode) ±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, Distance range: 50 km, Pulse width: 2 μs
Reflectance accuracy (multimode) ±4 dB
When measuring the non-connected end of an approximately 4.5 km length fiber, Distance range: 10 km, Pulse width: 100 ns
Distance accuracy ±1 m ±3 × measurement distance × 10-5 ± marker resolution
Excluding IOR uncertainty
Loss measurement accuracy (linearity) ±0.05 dB/dB or ±0.1 dB (whichever is greater)
Distance range (single mode) 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km
Distance range (multimode) 0.5, 1, 2.5, 5, 10, 25, 50, 100 km
Vertical scale 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div
IOR setting 1.300000 to 1.700000 (0.000001 steps)
Units km, m, kft, ft, mi
Real time sweep 0.15 sec.
Resolution: Low Density
OTDR trace format Telcordia universal. SOR, issue 2 (SR-4731)
Fiber Event Analysis
Operation Auto or manual operation, displayed in table format
Pass/Fail threshold, reflective and non-reflective events 0.01 to 9.99 dB (0.01-dB steps)
User defined
Pass/Fail threshold, reflectance 70.0 to 20.0 dB (0.1-dB steps)
User defined
Pass/Fail threshold, fiber end/break 1 to 99 dB (1-dB steps)
User defined
Number of detected events up to 99
Loss modes 2-point loss, dB/km, 2-point LSA, splice loss, ORL
Averaging modes Timed (1 to 3600 s)
PON splitter analysis Up to 1 × 128 branches
Stabilized Light Source (through OTDR port, standard)
Wavelength Same as OTDR
CW, 25°C
Spectral width ≤5 nm (1310 nm), ≤10 nm (850/1300/1490/1550/1625 nm)
CW, 25°C
Wavelength accuracy 850/1300/1310/1490/1550/1625 nm: ±30 nm
CW, 25°C
Output power –5 ±1.5 dBm
CW, 25°C
Output stability ≤0.1 dB
CW, –10°C to 50°C (±1°C) difference between max/min. values over 1 minute, SM fiber 2 m
Modes of operation CW, 270 Hz, 1 kHz, 2 kHz
Modulation +1.5% with 10 minute warm up
Standard Integrated Power Meter (through OTDR port)
Maximum input +10 dBm
Measurement range –50 to –5 dBm
Accuracy ±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, Using Anritsu's reference single mode fiber with FC/UPC connector
Setting wavelengths 1310, 1550, 1625, 1650 nm
Options 053, 055, 057, 063
Availability 1310/1550 nm SM port only; not available on 850/1300 nm MM port
Not available if Option 004, 005 or 007 is ordered
Features Store reference, loss table
Loss Test Set Power Meters (optional)
Measurement range
MT9085B-007
–67 to +6 dBm (CW, 1310 nm)
Peak power, subtract 3 dB for modulated tones; –60 to +3 dBm @850 nm
Measurement range
MT9085B-004
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Measurement range
MT9085B-005
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Fiber type
MT9085B-007
Single Mode: 10 μm/125 μm (G.652), Multimode: 62.5 μm/125 μm
Wavelength range
MT9085B-007
800 nm to 1700 nm
Setting wavelengths
MT9085B-007
850, 1300, 1310, 1383, 1490, 1550, 1625, 1650 nm
Accuracy
MT9085B-007
±5% (1310 nm/1550 nm), ±0.5 dB (850 nm)
CW, at –10 dBm (1310/1550 nm), at –10 dBm (850 nm), 25°C, after zero offset
Modulation CW, 270 Hz, 1 kHz, 2 kHz
Operating temperature and humidity 0°C to +50°C, <80% (non-condensing)
Visual Light Source (Option 002)
Central wavelength
MT9085B-002
650 nm±15 nm (at 25˚C)
Optical output
MT9085B-002
0 ±3 dBm (CW)
Output optical fiber
MT9085B-002
10 μm/125 μm, SMF (ITU-T G.652)
Optical connector
MT9085B-002
2.5 mm universal
Laser safety
MT9085B-002
IEC 60825-1: 2014 CLASS 3R
Display and Interfaces
Display 8-inch touch screen TFT-Color LCD
Interface USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
Wireless interface WLAN via USB adapter connected to USB port
Data storage Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB
Languages English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
Power
Power supply 12 V(dc), 100 V(ac) to 240 V(ac), Allowable input voltage range: 90 V to 264 V, 50 Hz/60 Hz
Battery type Lithium ion
Battery operating time 12 hours
Telcordia GR-196-CORE Issue 2, September 2010; typical, backlight Low, sweeping halted at 25˚C
Recharge time <5 hours (power off)
Power consumption 20 W max (recharging), 4 W standard (low backlight, sweep stopped)
Power saving functions Backlight off: Disable/1 to 99 minutes; Auto shutdown: Disable/1 to 99 minutes
Battery pack Z0921A 11.1 V, 4200 mAh
53 (W) × 19 (H) × 215 (D) mm, 330 g (typ.)
AC adapter Z1625A rated DC output 12 V(dc), 5 A
Rated AC input 100 V(ac) to 240 V(ac), 50 Hz/60 Hz
Physical
Dimensions (without protector) 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches
Mass (without protector) 1.6 kg without battery, 1.9 kg including battery
Dimensions (with protector, option 010) 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches
Mass (with protector, option 010) 2.6 kg including battery
Environmental and Compliance
Operating temperature and humidity –10°C to +50°C, <80% (non-condensing)
Storage temperature and humidity –20°C to +60°C, <80% (non-condensing)
Vibration Conforming to MIL-T-28800E Class 3
Ingress protection rating IEC60529 IP51
Shock MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off)
Bump: IEC 60068-2-27, JIS C60068-2-27; Shock-on-desk: MIL-T-28800E (45° angle or 100 mm lifted edge, 4 drops in total, power on)
CE EMC 2014/30/EU, EN61326-1, EN61000-3-2; LVD 2014/35/EU, EN61010-1; RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018
UKCA EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2; LVD S.I. 2016 No.1101, EN 61010-1; RoHS S.I. 2012 No.3032, EN IEC 63000:2018

Applications

  • Installation and maintenance of single-mode and multimode fiber
  • Metro and long-haul fiber networks
  • PON-based FTTx networks
  • Mobile fronthaul and backhaul
  • Access network troubleshooting
  • Fiber break location in drop cables
  • Optical connector end-face inspection
  • Cable certification testing

Included

  • Z1991A MT9085 Operation Manual (CD): 1 pc
  • W3974AE MT9085 Series Quick Guide: 1 pc
  • Z1625A AC adapter: 1 pc
  • Line cord: 1 pc
  • Z0921A Battery Pack: 1 pc

Options & Accessories

Option Description
MT9085B-025 FC-APC Connector — Key width 2.0 mm; can only connect APC-type optical fiber
MT9085B-026 SC-APC Connector — Can only connect APC-type optical fiber
MT9085B-037 FC Connector
MT9085B-038 ST Connector
MT9085B-039 DIN47256 Connector
MT9085B-040 SC Connector
MT9085B-002 Visual Fault Locator — Visible red light for fiber identification and troubleshooting
MT9085B-004 SMF Optical Power Meter — –50 to +23 dBm
MT9085B-005 SMF High Power Optical Power Meter — –43 to +30 dBm
MT9085B-007 SMF/MMF Optical Power Meter — –67 to +6 dBm
MT9085B-010 Protector — Front Protector B0584A cover supplied with belt as standard
G0306C Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation
W3971AE MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
W3972AE MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
B0745A Softcase
B0582A Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector
B0583A Hard transit case — Dimensions 420 (W) × 330 (H) × 148(D) mm
B0549 Hard carrying case
B0584A Front cover — Option 010 Protector cover only
Z0921A Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh
Z1632A Battery Charger — Li-ion battery charger
J1295 Car plug cord
J0617B Replaceable optical connector (FC-PC) — For OTDR port, for option power meter port
J0618D Replaceable optical connector (ST) — For OTDR port, for option power meter port
J0618F Replaceable optical connector (HMS-10/A) — For OTDR port, for option power meter port
J0619B Replaceable optical connector (SC-PC) — For OTDR port, for option power meter port
J0739A Replaceable optical connector (FC-APC) — For OTDR port
J1697A Replaceable optical connector (SC-APC) — For OTDR port
J0057 Optical adapter FC type — FC-FC connector (JJ adapter)
J1335A MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only)
MA9005B-37 For FC connector — For option power meter port (MT9085A/B/C-005)
MA9005B-38 For ST connector — For option power meter port (MT9085A/B/C-005)
MA9005B-40 For SC connector — For option power meter port (MT9085A/B/C-005)
LP-FC FC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-ST ST-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-SC SC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
J1530A SC plug in converter (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC
J1531A SC plug in converter (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC
J1532A FC plug in converter (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC
J1533A FC plug in converter (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC
J1534A LC-SC Plug-in Converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only)
J1535A LC-SC Plug-in Converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only)
Z0914A Ferrule cleaner — 1 pc
Z0915A Replacement reel for ferrule cleaner — 6 pcs for Z0914A
Z0284 Adapter Cleaner — Stick type (200 pcs/set)
J1950A USB-Ethernet converter — For remote GUI connection
NETWORKS NETWORKS PC analysis software — OTDR waveform analysis of .sor files and report creation on a Windows PC

Documents & Resources