ACCESS Master MT9085B-063 Enhanced SMF/MMF Handheld OTDR (1310/1550 nm SM, 850/1300 nm MM)
Handheld all-in-one OTDR for single-mode and multimode fiber at 1310/1550 nm SM and 850/1300 nm MM, with 42/41 dB SM dynamic range
- Wavelength
- 1310/1550 nm ±25 nm, 850/1300 nm ±30 nm
- Fiber type
- HYBRID (SMF/MMF)
- Pulse width (SMF)
- 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
- Pulse width (MMF)
- 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000 ns
Overview
The ACCESS Master MT9085B-063 is the all-in-one single-mode and multimode model of the Enhanced (Performance) tier in the Anritsu MT9085 series. It combines optical pulse testing (OTDR) at 1310/1550 nm on single-mode fiber and 850/1300 nm on multimode fiber with optical loss and power measurement and optical fiber end-face inspection in one compact handheld unit. It supports installation and maintenance (I&M) of SMF and MMF links in metro, long-haul and PON-based FTTx networks.
OTDR measurement
The OTDR measures fiber transmission loss and fiber length and detects events such as splices, connectors, splitters and breaks. The Fiber Visualizer function shows events as schematic icons with distance, loss and reflectance Pass/Fail results. Two realtime sweep modes, high-speed and high S/N, help locate fiber bends and check connections while the waveform is monitored. PON splitter analysis covers up to 1 × 128 branches. Manual analysis uses the rotary knob, hard keys and four markers with the two-point or LSA method.
Optical power, loss and end-face inspection
A stabilized light source and an optical power meter are built in as standard and use the OTDR port. Optional dedicated power meter ports add optical loss test set (OLTS) operation, and a visual fault locator is available as an option. With the external G0306C Video Inspection Probe, connector end faces can be inspected on the MT9085 screen and given automatic Pass/Fail evaluation to IEC61300-3-35.
Operation and data handling
The unit has an 8-inch color LCD touchscreen that can be used with work gloves on, together with dedicated hard keys and a rotary knob. Measurement data can be saved as original files (.sor, .vipi), .csv files, screen captures or PDF reports. Data can be transferred over USB, WLAN or Ethernet (through USB adapters), and the unit can be remote-controlled from a web-browser GUI or with remote commands.
Key Features
- 8-inch LCD touchscreen with easy visibility even in direct sunlight
- Touchscreen, rotary knob and dedicated hard keys for efficient operation
- All-in-one SMF/MMF model: 1310/1550 nm SM and 850/1300 nm MM OTDR wavelengths
- Fiber Visualizer function for simple fiber path analysis with Pass/Fail evaluation
- High-speed and high S/N realtime sweep modes for fast fiber bend location
- Identification of each splitter event for up to 1 × 128 branches
- Built-in stabilized light source and optical power meter as standard
- Optional visual fault locator and dedicated optical power meter ports
- Optical fiber end-face inspection with the external G0306C Video Inspection Probe
- Installation Test function for automatic measurement of multiple fibers
- Bi-directional waveform analysis
- Live fiber detection and connection check functions
- Cable Certification Test function with Pass/Fail evaluation to IEC/ISO standards
- Scenario Manager Lite for automated test execution without a PC
- 1 GB internal memory for up to 50,000 traces
- Telcordia SR-4731 trace format support
- Password protection function
- Remote control via web-browser GUI and remote commands
Specifications
| Wavelength |
1310/1550 nm ±25 nm, 850/1300 nm ±30 nm
25°C, Pulse width: 1 μs (all except 850 nm, 1300 nm), 850 nm/1300 nm: 100 ns
|
|---|---|
| Fiber type |
HYBRID (SMF/MMF)
Single mode: 10/125 μm, ITU-T G.652
|
| Pulse width (SMF) | 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns |
| Pulse width (MMF) |
3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000 ns
850 nm: Does not support 1000, 2000, 4000 ns
|
| Dynamic range (1310/1550 nm SM) |
42/41 dB
Typical; subtract 1 dB for guarantee. Pulse width 20 μs, distance range 100 km, averaging 180 sec., SNR = 1, 25°C
|
| Dynamic range (850/1300 nm MM) |
29/28 dB
Typical; subtract 1 dB for guarantee. Pulse width 500 ns (850 nm), 4 μs (1300 nm), distance range 25 km. With 50 μm/125 μm MM fiber the dynamic range drops by about 3.0 dB
|
| Dead zone (Fresnel) |
≤1 m, 0.8 m (typ.)
IOR = 1.500000; pulse width 3 ns, return loss 40 dB, 25°C
|
| Dead zone (Backscatter), SMF |
≤5/5.5 m
IOR = 1.500000; pulse width 10 ns, return loss 55 dB, deviation ±0.5 dB, 25°C
|
| Dead zone (Backscatter), MMF |
≤4/5 m (3/4 m typ.)
IOR = 1.500000; pulse width 3 ns, return loss 40 dB, deviation ±0.5 dB, 25°C
|
| Laser safety |
IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
|
| Sampling points |
Up to 150,001
Either high density value is selected depending on distance range
|
| Sampling resolution | 0.05 m to 60 m |
| Reflectance accuracy (single mode) |
±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, Distance range: 50 km, Pulse width: 2 μs
|
| Reflectance accuracy (multimode) |
±4 dB
When measuring the non-connected end of an approximately 4.5 km length fiber, Distance range: 10 km, Pulse width: 100 ns
|
| Distance accuracy |
±1 m ±3 × measurement distance × 10-5 ± marker resolution
Excluding IOR uncertainty
|
| Loss measurement accuracy (linearity) | ±0.05 dB/dB or ±0.1 dB (whichever is greater) |
| Distance range (single mode) | 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km |
| Distance range (multimode) | 0.5, 1, 2.5, 5, 10, 25, 50, 100 km |
| Vertical scale | 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div |
| IOR setting | 1.300000 to 1.700000 (0.000001 steps) |
| Units | km, m, kft, ft, mi |
| Real time sweep |
0.15 sec.
Resolution: Low Density
|
| OTDR trace format | Telcordia universal. SOR, issue 2 (SR-4731) |
| Operation | Auto or manual operation, displayed in table format |
|---|---|
| Pass/Fail threshold, reflective and non-reflective events |
0.01 to 9.99 dB (0.01-dB steps)
User defined
|
| Pass/Fail threshold, reflectance |
70.0 to 20.0 dB (0.1-dB steps)
User defined
|
| Pass/Fail threshold, fiber end/break |
1 to 99 dB (1-dB steps)
User defined
|
| Number of detected events | up to 99 |
| Loss modes | 2-point loss, dB/km, 2-point LSA, splice loss, ORL |
| Averaging modes | Timed (1 to 3600 s) |
| PON splitter analysis | Up to 1 × 128 branches |
| Wavelength |
Same as OTDR
CW, 25°C
|
|---|---|
| Spectral width |
≤5 nm (1310 nm), ≤10 nm (850/1300/1490/1550/1625 nm)
CW, 25°C
|
| Wavelength accuracy |
850/1300/1310/1490/1550/1625 nm: ±30 nm
CW, 25°C
|
| Output power |
–5 ±1.5 dBm
CW, 25°C
|
| Output stability |
≤0.1 dB
CW, –10°C to 50°C (±1°C) difference between max/min. values over 1 minute, SM fiber 2 m
|
| Modes of operation |
CW, 270 Hz, 1 kHz, 2 kHz
Modulation +1.5% with 10 minute warm up
|
| Maximum input | +10 dBm |
|---|---|
| Measurement range | –50 to –5 dBm |
| Accuracy |
±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, Using Anritsu's reference single mode fiber with FC/UPC connector
|
| Setting wavelengths |
1310, 1550, 1625, 1650 nm
Options 053, 055, 057, 063
|
| Availability |
1310/1550 nm SM port only; not available on 850/1300 nm MM port
Not available if Option 004, 005 or 007 is ordered
|
| Features | Store reference, loss table |
|
Measurement range
MT9085B-007
|
–67 to +6 dBm (CW, 1310 nm)
Peak power, subtract 3 dB for modulated tones; –60 to +3 dBm @850 nm
|
|---|---|
|
Measurement range
MT9085B-004
|
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
|
|
Measurement range
MT9085B-005
|
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
|
|
Fiber type
MT9085B-007
|
Single Mode: 10 μm/125 μm (G.652), Multimode: 62.5 μm/125 μm |
|
Wavelength range
MT9085B-007
|
800 nm to 1700 nm |
|
Setting wavelengths
MT9085B-007
|
850, 1300, 1310, 1383, 1490, 1550, 1625, 1650 nm |
|
Accuracy
MT9085B-007
|
±5% (1310 nm/1550 nm), ±0.5 dB (850 nm)
CW, at –10 dBm (1310/1550 nm), at –10 dBm (850 nm), 25°C, after zero offset
|
| Modulation | CW, 270 Hz, 1 kHz, 2 kHz |
| Operating temperature and humidity | 0°C to +50°C, <80% (non-condensing) |
|
Central wavelength
MT9085B-002
|
650 nm±15 nm (at 25˚C) |
|---|---|
|
Optical output
MT9085B-002
|
0 ±3 dBm (CW) |
|
Output optical fiber
MT9085B-002
|
10 μm/125 μm, SMF (ITU-T G.652) |
|
Optical connector
MT9085B-002
|
2.5 mm universal |
|
Laser safety
MT9085B-002
|
IEC 60825-1: 2014 CLASS 3R |
| Display | 8-inch touch screen TFT-Color LCD |
|---|---|
| Interface |
USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
|
| Wireless interface | WLAN via USB adapter connected to USB port |
| Data storage | Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB |
| Languages |
English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
|
| Power supply | 12 V(dc), 100 V(ac) to 240 V(ac), Allowable input voltage range: 90 V to 264 V, 50 Hz/60 Hz |
|---|---|
| Battery type | Lithium ion |
| Battery operating time |
12 hours
Telcordia GR-196-CORE Issue 2, September 2010; typical, backlight Low, sweeping halted at 25˚C
|
| Recharge time | <5 hours (power off) |
| Power consumption | 20 W max (recharging), 4 W standard (low backlight, sweep stopped) |
| Power saving functions | Backlight off: Disable/1 to 99 minutes; Auto shutdown: Disable/1 to 99 minutes |
| Battery pack Z0921A |
11.1 V, 4200 mAh
53 (W) × 19 (H) × 215 (D) mm, 330 g (typ.)
|
| AC adapter Z1625A rated DC output |
12 V(dc), 5 A
Rated AC input 100 V(ac) to 240 V(ac), 50 Hz/60 Hz
|
| Dimensions (without protector) | 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches |
|---|---|
| Mass (without protector) | 1.6 kg without battery, 1.9 kg including battery |
| Dimensions (with protector, option 010) | 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches |
| Mass (with protector, option 010) | 2.6 kg including battery |
| Operating temperature and humidity | –10°C to +50°C, <80% (non-condensing) |
|---|---|
| Storage temperature and humidity | –20°C to +60°C, <80% (non-condensing) |
| Vibration | Conforming to MIL-T-28800E Class 3 |
| Ingress protection rating | IEC60529 IP51 |
| Shock |
MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off)
Bump: IEC 60068-2-27, JIS C60068-2-27; Shock-on-desk: MIL-T-28800E (45° angle or 100 mm lifted edge, 4 drops in total, power on)
|
| CE | EMC 2014/30/EU, EN61326-1, EN61000-3-2; LVD 2014/35/EU, EN61010-1; RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018 |
| UKCA | EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2; LVD S.I. 2016 No.1101, EN 61010-1; RoHS S.I. 2012 No.3032, EN IEC 63000:2018 |
Applications
- Installation and maintenance of single-mode and multimode fiber
- Metro and long-haul fiber networks
- PON-based FTTx networks
- Mobile fronthaul and backhaul
- Access network troubleshooting
- Fiber break location in drop cables
- Optical connector end-face inspection
- Cable certification testing
Included
- Z1991A MT9085 Operation Manual (CD): 1 pc
- W3974AE MT9085 Series Quick Guide: 1 pc
- Z1625A AC adapter: 1 pc
- Line cord: 1 pc
- Z0921A Battery Pack: 1 pc
Options & Accessories
| Option | Description |
|---|---|
| MT9085B-025 | FC-APC Connector — Key width 2.0 mm; can only connect APC-type optical fiber |
| MT9085B-026 | SC-APC Connector — Can only connect APC-type optical fiber |
| MT9085B-037 | FC Connector |
| MT9085B-038 | ST Connector |
| MT9085B-039 | DIN47256 Connector |
| MT9085B-040 | SC Connector |
| MT9085B-002 | Visual Fault Locator — Visible red light for fiber identification and troubleshooting |
| MT9085B-004 | SMF Optical Power Meter — –50 to +23 dBm |
| MT9085B-005 | SMF High Power Optical Power Meter — –43 to +30 dBm |
| MT9085B-007 | SMF/MMF Optical Power Meter — –67 to +6 dBm |
| MT9085B-010 | Protector — Front Protector B0584A cover supplied with belt as standard |
| G0306C | Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation |
| W3971AE | MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| W3972AE | MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| B0745A | Softcase |
| B0582A | Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector |
| B0583A | Hard transit case — Dimensions 420 (W) × 330 (H) × 148(D) mm |
| B0549 | Hard carrying case |
| B0584A | Front cover — Option 010 Protector cover only |
| Z0921A | Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh |
| Z1632A | Battery Charger — Li-ion battery charger |
| J1295 | Car plug cord |
| J0617B | Replaceable optical connector (FC-PC) — For OTDR port, for option power meter port |
| J0618D | Replaceable optical connector (ST) — For OTDR port, for option power meter port |
| J0618F | Replaceable optical connector (HMS-10/A) — For OTDR port, for option power meter port |
| J0619B | Replaceable optical connector (SC-PC) — For OTDR port, for option power meter port |
| J0739A | Replaceable optical connector (FC-APC) — For OTDR port |
| J1697A | Replaceable optical connector (SC-APC) — For OTDR port |
| J0057 | Optical adapter FC type — FC-FC connector (JJ adapter) |
| J1335A | MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only) |
| MA9005B-37 | For FC connector — For option power meter port (MT9085A/B/C-005) |
| MA9005B-38 | For ST connector — For option power meter port (MT9085A/B/C-005) |
| MA9005B-40 | For SC connector — For option power meter port (MT9085A/B/C-005) |
| LP-FC | FC-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| LP-ST | ST-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| LP-SC | SC-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| J1530A | SC plug in converter (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC |
| J1531A | SC plug in converter (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC |
| J1532A | FC plug in converter (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC |
| J1533A | FC plug in converter (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC |
| J1534A | LC-SC Plug-in Converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only) |
| J1535A | LC-SC Plug-in Converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only) |
| Z0914A | Ferrule cleaner — 1 pc |
| Z0915A | Replacement reel for ferrule cleaner — 6 pcs for Z0914A |
| Z0284 | Adapter Cleaner — Stick type (200 pcs/set) |
| J1950A | USB-Ethernet converter — For remote GUI connection |
| NETWORKS | NETWORKS PC analysis software — OTDR waveform analysis of .sor files and report creation on a Windows PC |