ACCESS Master MT9085B-058 Handheld OTDR, 1310/1490/1550/1625 nm SM
Enhanced-range ACCESS Master handheld OTDR with 1310/1490/1550/1625 nm single-mode wavelengths for FTTx/PON and CWDM band evaluation.
- Wavelength
- 1310/1490/1550/1625 nm ±25 nm
- Fiber type
- Single Mode (SMF) 10/125 μm ITU-T G.652
- Mode
- HR/ER
- Pulse width
- 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Overview
The ACCESS Master MT9085B-058 is the four-wavelength Enhanced (Performance class) model of the Anritsu MT9085 series, a compact handheld all-in-one tester for optical pulse (OTDR) tests, optical loss and power measurements, and optical fiber end-face inspection. Its 1310/1490/1550/1625 nm single-mode OTDR module is intended for installation and maintenance of FTTx/PON networks and for sectioned evaluation of the CWDM wavelength band.
OTDR measurement
The OTDR measures fiber transmission loss and length and detects events such as splices, connectors, splitters and breaks. The Fiber Visualizer function displays events as schematic icons with distance, loss and reflectance Pass/Fail results, while the standard OTDR mode supports manual analysis with four markers using the two-point and LSA methods. Two realtime sweep modes (high-speed and high S/N) help locate fiber bends, and PON splitter analysis covers up to 1 × 128 branches.
Power, loss and end-face inspection
A stabilized light source and optical power meter are built in as standard through the OTDR port. Optional dedicated power meter ports support optical loss test set (OLTS) measurements, an optional visual fault locator shows light leaking at fiber breaks, and the external G0306C Video Inspection Probe enables connector end-face inspection with automatic Pass/Fail evaluation to IEC61300-3-35.
Operation and data handling
The unit combines an 8-inch color LCD touchscreen with a rotary knob and dedicated hard keys, and the touchscreen accepts input with work gloves on. Results can be saved as .sor, .csv, screen captures or PDF reports in 1 GB of internal memory and transferred via USB memory, USB cable, WLAN or Ethernet (via USB adapters), with remote control by web browser GUI or remote commands.
Key Features
- 8-inch LCD touchscreen with easy visibility even in direct sunlight
- Operation via touchscreen, rotary knob and dedicated hard keys
- Fiber Visualizer function for simple fiber path analysis with Pass/Fail evaluation
- High-speed and high S/N real-time sweep modes for fast fiber bend location
- High-accuracy event detection and loss measurement
- Identification of each splitter event for up to 1 × 128 branches
- Built-in stabilized light source and optical power meter as standard
- Optional optical power meter, visual fault locator and external fiberscope
- Optical fiber end-face inspection with automatic Pass/Fail evaluation to IEC61300-3-35
- Installation Test function for automatic measurement of multiple fibers
- Bi-directional waveform analysis
- Optical Communications Check function detects live traffic before OTDR measurement
- Connection check of OTDR to fiber-under-test quality
- Cable Certification Test function with PDF report output
- Scenario Manager Lite for automated test execution without a PC
- Telcordia SR-4731 trace format support
- 1 GB internal memory for up to 50,000 traces
- Remote GUI control by web browser and remote commands
- Password protection function
- 12-hour battery operation
Specifications
| Wavelength |
1310/1490/1550/1625 nm ±25 nm
25°C, pulse width: 1 μs
|
|---|---|
| Fiber type | Single Mode (SMF) 10/125 μm ITU-T G.652 |
| Mode |
HR/ER
HR: High Resolution mode for short dead zone; ER: Enhanced Range mode for PON measurement
|
| Pulse width | 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns |
| Dynamic range |
42/41/41/40 dB
Typical, subtract 1 dB for guarantee. Pulse width 20 μs, distance range 100 km, averaging 180 sec., SNR = 1, 25°C
|
| Dead zone (Fresnel) |
≤1 m, 0.8 m (typ.)
IOR = 1.500000; pulse width 3 ns, return loss 40 dB, 25°C
|
| Dead zone (Backscatter) |
≤7/7.5/7.5/8.5 m
IOR = 1.500000; pulse width 10 ns, return loss 55 dB, deviation ±0.5 dB, 25°C
|
| Laser safety |
IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
|
| Distance range |
0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km
Single mode
|
|---|---|
| Sampling points |
Up to 150,001
Either high density value is selected depending on distance range
|
| Sampling resolution | 0.05 m to 60 m |
| Reflectance accuracy |
±2 dB
Single mode; when measuring the non-connected end of an approximately 25 km fiber, distance range 50 km, pulse width 2 μs
|
| Distance accuracy |
±1 m ±3 × measurement distance × 10-5 ± marker resolution
Excluding IOR uncertainty
|
| Loss measurement accuracy (linearity) | ±0.05 dB/dB or ±0.1 dB (whichever is greater) |
| Vertical scale | 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div |
| IOR setting | 1.300000 to 1.700000 (0.000001 steps) |
| Units | km, m, kft, ft, mi |
| Fiber event analysis thresholds |
Reflective and non-reflective events: 0.01 to 9.99 dB (0.01-dB steps); Reflectance: 70.0 to 20.0 dB (0.1-dB steps); Fiber end/break: 1 to 99 dB (1-dB steps)
User defined Pass/Fail thresholds
|
| Number of detected events | up to 99 |
| OTDR trace format | Telcordia universal. SOR, issue 2 (SR-4731) |
| Real time sweep |
0.15 sec.
Resolution: Low Density
|
| Loss modes | 2-point loss, dB/km, 2-point LSA, splice loss, ORL |
| Averaging modes | Timed (1 to 3600 s) |
| Wavelength |
Same as OTDR
Stabilized light source through OTDR port; CW, 25°C
|
|---|---|
| Spectral width |
≤5 nm (1310 nm), ≤10 nm (850/1300/1490/1550/1625 nm)
CW, 25°C
|
| Wavelength accuracy |
850/1300/1310/1490/1550/1625 nm: ±30 nm
CW, 25°C
|
| Output power |
–5 ±1.5 dBm
CW, 25°C
|
| Output stability |
≤0.1 dB
CW, –10°C to 50°C (±1°C), difference between max/min values over 1 minute, SM fiber 2 m
|
| Modes of operation |
CW, 270 Hz, 1 kHz, 2 kHz
Modulation +1.5% with 10 minute warm up
|
| Maximum input |
+10 dBm
Through OTDR port; not available if Option 004, 005 or 007 is ordered
|
|---|---|
| Measurement range | –50 to –5 dBm |
| Accuracy |
±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, Anritsu reference SM fiber with FC/UPC connector
|
| Setting wavelengths |
1310, 1490, 1550, 1625 nm
Options 056, 058
|
| Features | Store reference, loss table |
|
Measurement range
MT9085B-004
|
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
|
|---|---|
|
Measurement range
MT9085B-005
|
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
|
|
Measurement range
MT9085B-007
|
–67 to +6 dBm (CW, 1310 nm)
–60 to +3 dBm at 850 nm; peak power, subtract 3 dB for modulated tones
|
| Modulation | CW, 270 Hz, 1 kHz, 2 kHz |
| Operating temperature and humidity | 0°C to +50°C, <80% (non-condensing) |
|
Central wavelength
MT9085B-002
|
650 nm±15 nm (at 25˚C) |
|---|---|
|
Optical output
MT9085B-002
|
0 ±3 dBm (CW) |
|
Optical connector
MT9085B-002
|
2.5 mm universal |
|
Laser safety
MT9085B-002
|
IEC 60825-1: 2014 CLASS 3R |
| Display | 8-inch touch screen TFT-Color LCD |
|---|---|
| Interface |
USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
|
| Wireless interface | WLAN via USB adapter connected to USB port |
| Data storage | Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB |
| Languages |
English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
|
| Power supply | 12 V(dc), 100 V(ac) to 240 V(ac), Allowable input voltage range: 90 V to 264 V, 50 Hz/60 Hz |
|---|---|
| Battery type | Lithium ion |
| Battery operating time |
12 hours
Typical, Telcordia GR-196-CORE Issue 2, September 2010; backlight Low, sweeping halted at 25˚C
|
| Recharge time | <5 hours (power off) |
| Power consumption | 20 W max (recharging), 4 W standard (low backlight, sweep stopped) |
| Dimensions (without protector) | 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches |
|---|---|
| Mass (without protector) | 1.6 kg without battery, 1.9 kg including battery |
|
Dimensions (with protector, option 010)
MT9085B-010
|
284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches |
|
Mass (with protector, option 010)
MT9085B-010
|
2.6 kg including battery |
| Operating temperature and humidity | –10°C to +50°C, <80% (non-condensing) |
|---|---|
| Storage temperature and humidity | –20°C to +60°C, <80% (non-condensing) |
| Vibration | Conforming to MIL-T-28800E Class 3 |
| Ingress protection rating | IEC60529 IP51 |
| Shock | MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off) |
Applications
- FTTx/PON installation and maintenance
- Partial evaluation of CWDM wavelength band
- Metro networks
- Long haul networks
- Mobile fronthaul and backhaul
- Access network troubleshooting
- Base station installation and maintenance
- Optical fiber end-face inspection
Included
- Z1991A MT9085 Operation Manual (CD)
- W3974AE MT9085 Series Quick Guide
- Z1625A AC adapter
- Line cord
- Z0921A Battery Pack
Options & Accessories
| Option | Description |
|---|---|
| MT9085B-002 | Visual Fault Locator — Visual light source for locating fiber breaks |
| MT9085B-004 | SMF Optical Power Meter — –50 to +23 dBm |
| MT9085B-005 | SMF High Power Optical Power Meter — –43 to +30 dBm |
| MT9085B-007 | SMF/MMF Optical Power Meter — –67 to +6 dBm |
| MT9085B-010 | Protector — Front Protector B0584A cover supplied with belt as standard |
| MT9085B-025 | FC-APC Connector Key width 2.0 mm |
| MT9085B-026 | SC-APC Connector |
| MT9085B-037 | FC Connector |
| MT9085B-038 | ST Connector |
| MT9085B-040 | SC Connector |
| G0306C | Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation |
| W3971AE | MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| W3972AE | MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| B0745A | Softcase |
| B0582A | Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector |
| B0583A | Hard transit case — Dimensions 420 (W) × 330 (H) × 148(D) mm |
| B0549 | HARD CARRYING CASE |
| B0584A | Front cover — Option 010 Protector cover only |
| Z0921A | Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh |
| Z1632A | Battery Charger — Li-ion battery charger |
| J1295 | CAR PLUG CORD |
| J0617B | Replaceable optical connector (FC-PC) — For OTDR port, for option power meter port |
| J0618D | Replaceable optical connector (ST) — For OTDR port, for option power meter port |
| J0619B | Replaceable optical connector (SC-PC) — For OTDR port, for option power meter port |
| J0739A | Replaceable optical connector (FC-APC) — For OTDR port |
| J1697A | Replaceable optical connector (SC-APC) — For OTDR port |
| J1335A | MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only) |
| J1950A | USB-Ethernet converter — For remote GUI connection |
| Z0914A | Ferrule cleaner |
| NETWORKS | NETWORKS PC analysis software — OTDR waveform analysis of .sor files and report creation on a Windows PC |