Anritsu ACCESS Master MT9085 Series handheld OTDR front view
MT9085B-056

ACCESS Master MT9085B-056 1310/1490/1550 nm SMF OTDR for FTTx/PON Installation and Maintenance

Handheld enhanced-range OTDR at 1310/1490/1550 nm for FTTx/PON installation and maintenance, with 42/41/41 dB dynamic range.

Wavelength
1310/1490/1550 nm ±25 nm
Fiber type
Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width
3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic range
42/41/41 dB

Overview

The ACCESS Master MT9085B-056 is the 1310/1490/1550 nm single-mode configuration of the Enhanced (B) model in Anritsu's MT9085 series. The series is a compact handheld all-in-one tester for optical pulse tests (OTDR), optical loss and power measurements, and optical fiber end-face inspection. Anritsu positions the -056 as the model for installation and maintenance of FTTx/PON networks.

The instrument has an 8-inch color LCD touchscreen. It also keeps the hard keys and rotary knob of earlier ACCESS Master models for manual trace analysis. The Fiber Visualizer function shows events such as splices, connectors, PON splitters and the fiber end as schematic icons, with Pass/Fail evaluation of loss and reflectance. PON network measurements are supported for up to 1 × 128 branches, with preset splitter information and thresholds.

Measurement functions

Two realtime sweep modes are provided: high-speed for locating fiber bends and high S/N for easier loss measurement. Other functions include multi-fiber Installation Test, bi-directional analysis, live-fiber detection (Optical Communications Check), connection check, Cable Certification Test to IEC/ISO standards, and Scenario Manager Lite for automated test sequences. A stabilized light source and an optical power meter are built in through the OTDR port. A dedicated-port power meter, a visual fault locator and the external G0306C Video Inspection Probe are options.

Data handling

Measurements are saved in their original formats (.sor for OTDR, .vipi for VIP), as .csv, as screen captures or as PDF reports. Files can be transferred over USB memory, USB cable, Ethernet (USB-Ethernet adapter) or WLAN (USB dongle). The instrument can be controlled remotely through a web browser GUI or remote commands. On a PC, OTDR traces are analyzed with NETWORKS software and VIP data with Connector Master MX900030A.

Key Features

  • 8-inch LCD touchscreen with easy visibility even in direct sunlight
  • Operation by touchscreen, rotary knob and dedicated hard keys
  • Pressure-sensitive touchscreen supports input without removing work gloves
  • Fiber Visualizer function for simple fiber path analysis with Pass/Fail evaluation
  • High-speed and high S/N real-time sweep modes for fast fiber bend location
  • Identification of each splitter event and up to 1 × 128 branches
  • Built-in stabilized light source and optical power meter through the OTDR port
  • Optional dedicated-port optical power meters for OLTS loss measurement
  • Optional visual fault locator
  • Optical fiber end-face inspection using the external G0306C Video Inspection Probe
  • Automatic end-face Pass/Fail evaluation to IEC61300-3-35
  • Cable Certification Test function with automatic Pass/Fail to IEC/ISO standards
  • Installation Test function for uninterrupted automatic measurement of multiple fibers
  • Bi-directional waveform analysis
  • Optical Communications Check stops OTDR measurement when live traffic is detected
  • Connection check of the OTDR output connection condition
  • Telcordia SR-4731 trace format support
  • Scenario Manager Lite for automated test execution without a PC
  • Internal memory of 1 GB for up to 50,000 traces
  • Remote control via web browser GUI or remote commands over WLAN or Ethernet
  • Password protection function
  • 12-hour battery operation

Specifications

OTDR
Wavelength 1310/1490/1550 nm ±25 nm
25°C, pulse width: 1 μs
Fiber type Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic range 42/41/41 dB
Typical, subtract 1 dB for guarantee; pulse width 20 μs, distance range 100 km, averaging 180 sec., SNR = 1, 25°C; one-way back-scattered light
Dead zone (Fresnel) ≤1 m, 0.8 m (typ.)
IOR = 1.500000; pulse width 3 ns, return loss 40 dB, 25°C
Dead zone (Backscatter) ≤6/6.5/6.5 m
IOR = 1.500000; pulse width 10 ns, return loss 55 dB, deviation ±0.5 dB, 25°C
Measurement mode HR/ER
HR: High Resolution mode for short dead zone; ER: Enhanced Range mode for PON measurement
Laser safety IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
Sampling points Up to 150,001
Either high density value is selected depending on distance range
Sampling resolution 0.05 m to 60 m
Distance range (single mode) 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km
Distance accuracy ±1 m ±3 × measurement distance × 10-5 ± marker resolution
Excluding IOR uncertainty
Reflectance accuracy (single mode) ±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, distance range: 50 km, pulse width: 2 μs
Loss measurement accuracy (linearity) ±0.05 dB/dB or ±0.1 dB (whichever is greater)
Vertical scale 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div
IOR setting 1.300000 to 1.700000 (0.000001 steps)
Units km, m, kft, ft, mi
Real time sweep 0.15 sec.
Resolution: Low Density
OTDR trace format Telcordia universal. SOR, issue 2 (SR-4731)
Fiber Event Analysis
Operation Auto or manual operation, displayed in table format
Pass/Fail threshold: reflective and non-reflective events 0.01 to 9.99 dB (0.01-dB steps)
User defined
Pass/Fail threshold: reflectance 70.0 to 20.0 dB (0.1-dB steps)
User defined
Pass/Fail threshold: fiber end/break 1 to 99 dB (1-dB steps)
User defined
Number of detected events up to 99
Macrobend detection Macrobend detection
Loss modes 2-point loss, dB/km, 2-point LSA, splice loss, ORL
Averaging modes Timed (1 to 3600 s)
Other functions Live Fiber detect, Connection check, Trace overlay and comparison, Template function, USB keyboard support, Remote control, Remote GUI, Password protection feature
Testing Modes
Fiber Visualizer Provides end/break location, end to end loss, fiber length, easy graphical summary, PDF report
Standard OTDR User selectable automatic or manual set-up
Construction OTDR Automated, multi-wavelength testing
Light source Stabilized Light source (CW, 270 Hz, 1 kHz, 2 kHz output)
Loss test set Power meter and Light source
Optional
Connector Video Inspection Probe
Optional
Visual fault locator Visible red light for fiber identification and troubleshooting
Optional
Stabilized Light Source (through OTDR port)
Wavelength Same as OTDR
CW, 25°C
Spectral width (1310 nm) ≤5 nm
CW, 25°C
Spectral width (1490/1550 nm) ≤10 nm
CW, 25°C
Wavelength accuracy ±30 nm
CW, 25°C; 850/1300/1310/1490/1550/1625 nm
Output power –5 ±1.5 dBm
CW, 25°C
Output stability ≤0.1 dB
CW, –10°C to 50°C (±1°C) difference between max/min. values over 1 minute, SM fiber 2 m
Modes of operation CW, 270 Hz, 1 kHz, 2 kHz
Modulation +1.5% with 10 minute warm up
Standard Integrated Power Meter (through OTDR port)
Maximum input +10 dBm
Measurement range –50 to –5 dBm
Accuracy ±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, using Anritsu's reference single mode fiber with FC/UPC connector
Setting wavelengths 1310, 1490, 1550, 1625 nm
Options 056, 058
Features Store reference, loss table
Not available if Option 004, 005 or 007 is ordered
Loss Test Set Power Meters (Optional)
Measurement range
MT9085A/B/C-004
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Measurement range
MT9085A/B/C-005
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Measurement range
MT9085A/B/C-007
–67 to +6 dBm (CW, 1310 nm)
Peak power, subtract 3 dB for modulated tones; –60 to +3 dBm at 850 nm
Modulation CW, 270 Hz, 1 kHz, 2 kHz
Environmental Operating temperature and humidity: 0°C to +50°C, <80% (non-condensing)
Visual Light Source (Option 002)
Central wavelength
MT9085A/B/C-002
650 nm±15 nm (at 25˚C)
Optical output
MT9085A/B/C-002
0 ±3 dBm (CW)
Output optical fiber
MT9085A/B/C-002
10 μm/125 μm, SMF (ITU-T G.652)
Optical connector
MT9085A/B/C-002
2.5 mm universal
Laser safety
MT9085A/B/C-002
IEC 60825-1: 2014 CLASS 3R
General
Display 8-inch touch screen TFT-Color LCD
Interface USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
Wireless interface WLAN via USB adapter connected to USB port
Data storage Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB
Languages English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
Power
Power supply 12 V(dc), 100 V(ac) to 240 V(ac), Allowable input voltage range: 90 V to 264 V, 50 Hz/60 Hz
Battery type Lithium ion
Battery Pack Z0921A: 11.1 V, 4200 mAh
Battery operating time 12 hours
Telcordia GR-196-CORE Issue 2, September 2010; typical, backlight Low, sweeping halted at 25˚C
Recharge time <5 hours (power off)
Power consumption 20 W max (recharging), 4 W standard (low backlight, sweep stopped)
Power saving functions Backlight off: Disable/1 to 99 minutes, Auto shutdown: Disable/1 to 99 minutes
Physical
Dimensions (without protector) 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches
Mass (without protector) 1.6 kg without battery, 1.9 kg including battery
Dimensions (with protector, option 010) 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches
Mass (with protector, option 010) 2.6 kg including battery
Environmental
Operating temperature and humidity –10°C to +50°C, <80% (non-condensing)
Storage temperature and humidity –20°C to +60°C, <80% (non-condensing)
Vibration Conforming to MIL-T-28800E Class 3
Ingress protection rating IEC60529 IP51
Shock MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off), Bump: IEC 60068-2-27, JIS C60068-2-27
Shock-on-desk MIL-T-28800E (45° angle or 100 mm lifted edge, 4 drops in total, power on)
Compliance
CE EMC 2014/30/EU, EN61326-1, EN61000-3-2
CE LVD 2014/35/EU, EN61010-1
CE RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018
UKCA EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2
UKCA LVD S.I. 2016 No.1101, EN 61010-1
UKCA RoHS S.I. 2012 No.3032, EN IEC 63000:2018

Applications

  • FTTx/PON installation and maintenance
  • PON splitter analysis
  • Access network troubleshooting
  • Drop cable break location
  • Metro network installation and maintenance
  • Mobile fronthaul and backhaul fiber testing
  • Fiber bend location
  • Optical loss and power measurement
  • Fiber connector end-face inspection
  • Cable certification testing

Included

  • Z1991A MT9085 Operation Manual (CD): 1 pc
  • W3974AE MT9085 Series Quick Guide: 1 pc
  • Z1625A AC adapter: 1 pc
  • Line cord: 1 pc
  • Z0921A Battery Pack: 1 pc

Options & Accessories

Option Description
MT9085x-025 FC-APC Connector Key width 2.0 mm — Specify A, B, or C at x; can only connect APC-type optical fiber
MT9085x-026 SC-APC Connector — Specify A, B, or C at x; can only connect APC-type optical fiber
MT9085x-037 FC Connector — Specify A, B, or C at x
MT9085x-038 ST Connector — Specify A, B, or C at x
MT9085A/B/C-039 DIN47256 Connector
MT9085x-040 SC Connector — Specify A, B, or C at x
MT9085x-002 Visual Fault Locator — Visual light source option
MT9085x-004 SMF Optical Power Meter — –50 to +23 dBm
MT9085x-005 SMF High Power Optical Power Meter — –43 to +30 dBm
MT9085x-007 SMF/MMF Optical Power Meter — –67 to +6 dBm
MT9085x-010 Protector — Front Protector B0584A cover supplied with belt as standard
W3971AE MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
W3972AE MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
B0745A Softcase
B0582A Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector
B0583A Hard transit case — Dimensions 420 (W) × 330 (H) × 148(D) mm
B0549 HARD CARRYING CASE
B0584A Front cover — Option 010 Protector cover only
Z0921A Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh
Z1632A Battery Charger — Li-ion battery charger
J1295 CAR PLUG CORD
J0617B Replaceable optical connector (FC-PC) — For OTDR port, For option power meter port (MT9085A/B/C)
J0618D Replaceable optical connector (ST) — For OTDR port, For option power meter port (MT9085A/B/C)
J0618F Replaceable optical connector (HMS-10/A) — For OTDR port, For option power meter port (MT9085A/B/C)
J0619B Replaceable optical connector (SC-PC) — For OTDR port, For option power meter port (MT9085A/B/C)
J0739A Replaceable optical connector (FC-APC) — For OTDR port (MT9085A/B/C)
J1697A Replaceable optical connector (SC-APC) — For OTDR port (MT9085A/B/C)
J0057 OPTICAL ADAPTER FC TYPE — FC-FC connector (JJ adapter)
J1335A MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only)
MA9005B-37 FOR FC CONNECTOR — For option power meter port (MT9085A/B/C-005)
MA9005B-38 FOR ST CONNECTOR — For option power meter port (MT9085A/B/C-005)
MA9005B-40 FOR SC CONNECTOR — For option power meter port (MT9085A/B/C-005)
LP-FC FC-PC POWER METER ADAPTER — For option power meter port (MT9085A/B/C-007)
LP-ST ST-PC POWER METER ADAPTER — For option power meter port (MT9085A/B/C-007)
LP-SC SC-PC POWER METER ADAPTER — For option power meter port (MT9085A/B/C-007)
J1530A SC PLUG IN CONVERTER (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC
J1531A SC PLUG IN CONVERTER (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC
J1532A FC PLUG IN CONVERTER (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC
J1533A FC PLUG IN CONVERTER (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC
J1534A LC-SC Plug-in Converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only)
J1535A LC-SC Plug-in Converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only)
Z0914A Ferrule cleaner — 1 pc
Z0915A Replacement reel for ferrule cleaner — 6 pcs for Z0914A
Z0284 Adapter Cleaner — Stick type (200 pcs/set)
G0306C Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation
J1950A USB-Ethernet converter — For remote GUI connection
NETWORKS NETWORKS PC software — OTDR waveform analysis and report creation software for Microsoft Windows (sold separately)

Documents & Resources