ACCESS Master MT9085A-057 1310/1550/1625 nm SMF Handheld OTDR
Standard-class handheld ACCESS Master OTDR with 1310/1550/1625 nm single-mode wavelengths for macrobend analysis and fiber I&M.
- Wavelength
- 1310/1550/1625 nm ±25 nm
- Fiber type
- Single Mode (SMF) 10/125 μm ITU-T G.652
- Pulse width
- 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
- Dynamic range
- 37/35.5/32.5 dB
Overview
The ACCESS Master MT9085A-057 is the Standard-class member of the Anritsu MT9085 series configured with a 1310/1550/1625 nm single-mode OTDR module. The 1625 nm wavelength supports maintenance inspection and macrobend analysis alongside the standard 1310 nm and 1550 nm test wavelengths. The unit is a compact handheld all-in-one tester for optical pulse tests, optical loss and power measurements, and optical fiber end-face inspection.
OTDR measurement
The optical pulse test measures fiber transmission loss and fiber length and detects events such as breaks in fiber continuity. The Fiber Visualizer function displays events such as splices, connectors, PON splitters and the fiber end as schematic icons, with distance, loss and reflectance Pass/Fail evaluation against preset thresholds. Two realtime sweep modes (high-speed and high S/N) help locate fiber bends and the far end before averaging. Manual analysis uses the rotary knob, hard keys and four-marker operation with 2-point and LSA methods, and the touchscreen can be operated with work gloves on.
Power, loss and end-face inspection
A stabilized light source and an optical power meter are built in through the OTDR port. Dedicated power meter options add optical loss test set (OLTS) operation on a separate port, and a visual fault locator option helps locate breaks. With the external G0306C Video Inspection Probe (sold separately), the unit inspects connector end faces and gives Pass/Fail evaluation in accordance with IEC61300-3-35.
Data management
Measurement data can be saved in original formats (.sor, .vipi), as .csv files, as screen captures or as PDF reports. Files can be transferred to a PC by USB memory, USB cable, Ethernet or WLAN through USB adapters. The unit can also be controlled remotely through a web browser GUI or remote commands. Other functions include Cable Certification Test, Scenario Manager Lite, bi-directional analysis, the Installation Test for multiple fibers, and password protection.
Key Features
- 1310/1550/1625 nm single-mode OTDR supporting maintenance inspection wavelengths for microbend analysis
- 8-inch LCD touchscreen with easy visibility even in direct sunlight
- Operation through touchscreen, rotary knob and dedicated hard keys
- Fiber Visualizer function for simple fiber path analysis with Pass/Fail evaluation
- High-speed and high S/N real-time sweep modes for fast fiber bend location
- Identification of each splitter event and up to 1 × 128 branches
- Built-in stabilized light source and optical power meter through the OTDR port
- Optional visual fault locator and optical power meter options
- Optical fiber end-face inspection using external fiberscope option
- Live fiber detection and OTDR connection check
- Bi-directional measurement analysis
- Cable Certification Test function with PDF report output
- Scenario Manager Lite for automated test sequences without a PC
- Telcordia SR-4731 trace format support
- Remote control through web browser GUI and remote commands
- Password protection function
- 12-hour battery operation
Specifications
| Wavelength |
1310/1550/1625 nm ±25 nm
25°C, pulse width: 1 μs
|
|---|---|
| Fiber type | Single Mode (SMF) 10/125 μm ITU-T G.652 |
| Pulse width | 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns |
| Dynamic range |
37/35.5/32.5 dB
Typical; subtract 1 dB for guarantee. Pulse width 20 μs, distance range 100 km, averaging 180 sec., SNR = 1, 25°C
|
| Dead zone (Fresnel) |
≤1 m, 0.8 m (typ.)
IOR = 1.500000; pulse width 3 ns, return loss 40 dB, 25°C
|
| Dead zone (Backscatter) |
≤6/6.5/7.5 m
IOR = 1.500000; pulse width 10 ns, return loss 55 dB, deviation ±0.5 dB, 25°C
|
| Laser safety |
IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
|
| Sampling points |
Up to 150,001
High density value is selected depending on distance range
|
| Sampling resolution | 0.05 m to 60 m |
| Distance range | Single mode: 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km |
| Distance accuracy |
±1 m ±3 × measurement distance × 10-5 ± marker resolution
Excluding IOR uncertainty
|
| Reflectance accuracy |
Single mode: ±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, distance range: 50 km, pulse width: 2 μs
|
| Loss measurement accuracy (linearity) | ±0.05 dB/dB or ±0.1 dB (whichever is greater) |
| Vertical scale | 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div |
| IOR setting | 1.300000 to 1.700000 (0.000001 steps) |
| Units | km, m, kft, ft, mi |
| Real time sweep |
0.15 sec.
Resolution: Low Density
|
| OTDR trace format | Telcordia universal. SOR, issue 2 (SR-4731) |
| Operation | Auto or manual operation, displayed in table format |
|---|---|
| Pass/Fail threshold: reflective and non-reflective events |
0.01 to 9.99 dB (0.01-dB steps)
User defined
|
| Pass/Fail threshold: reflectance |
70.0 to 20.0 dB (0.1-dB steps)
User defined
|
| Pass/Fail threshold: fiber end/break |
1 to 99 dB (1-dB steps)
User defined
|
| Number of detected events | up to 99 |
| Loss modes | 2-point loss, dB/km, 2-point LSA, splice loss, ORL |
| Averaging modes | Timed (1 to 3600 s) |
| Type | Stabilized Light Source (through OTDR port) |
|---|---|
| Wavelength |
Same as OTDR
CW, 25°C
|
| Spectral width |
≤5 nm (1310 nm), ≤10 nm (1550/1625 nm)
CW, 25°C
|
| Wavelength accuracy |
±30 nm
1310/1550/1625 nm; CW, 25°C
|
| Output power |
–5 ±1.5 dBm
CW, 25°C
|
| Output stability |
≤0.1 dB
CW, –10°C to 50°C (±1°C), difference between max/min values over 1 minute, SM fiber 2 m
|
| Modes of operation |
CW, 270 Hz, 1 kHz, 2 kHz
Modulation +1.5% with 10 minute warm up
|
| Port |
through OTDR port
Not available if Option 004, 005 or 007 is ordered
|
|---|---|
| Maximum input | +10 dBm |
| Measurement range | –50 to –5 dBm |
| Accuracy |
±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, using Anritsu's reference single mode fiber with FC/UPC connector
|
| Setting wavelengths |
1310, 1550, 1625, 1650 nm
Options 053, 055, 057, 063
|
| Features | Store reference, loss table |
|
Measurement range
MT9085A-007
|
–67 to +6 dBm (CW, 1310 nm)
Peak power, subtract 3 dB for modulated tones; –60 to +3 dBm @850 nm
|
|---|---|
|
Measurement range
MT9085A-004
|
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
|
|
Measurement range
MT9085A-005
|
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
|
|
Wavelength range
MT9085A-007
|
800 nm to 1700 nm |
|
Wavelength range
MT9085A-004, MT9085A-005
|
1200 nm to 1700 nm |
| Modulation | CW, 270 Hz, 1 kHz, 2 kHz |
| Environmental | Operating temperature and humidity: 0°C to +50°C, <80% (non-condensing) |
|
Central wavelength
MT9085A-002
|
650 nm±15 nm (at 25˚C) |
|---|---|
|
Optical output
MT9085A-002
|
0 ±3 dBm (CW) |
|
Output optical fiber
MT9085A-002
|
10 μm/125 μm, SMF (ITU-T G.652) |
|
Optical connector
MT9085A-002
|
2.5 mm universal |
|
Laser safety
MT9085A-002
|
IEC 60825-1: 2014 CLASS 3R |
| Display | 8-inch touch screen TFT-Color LCD |
|---|---|
| Interface |
USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
|
| Wireless interface | WLAN via USB adapter connected to USB port |
| Data storage | Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB |
| Languages |
English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
|
| Power supply | 12 V(dc), 100 V(ac) to 240 V(ac), Allowable input voltage range: 90 V to 264 V, 50 Hz/60 Hz |
|---|---|
| Battery type | Lithium ion |
| Battery operating time |
12 hours
Telcordia GR-196-CORE Issue 2, September 2010; typical, backlight Low, sweeping halted at 25˚C
|
| Recharge time | <5 hours (power off) |
| Power consumption | 20 W max (recharging), 4 W standard (low backlight, sweep stopped) |
| Power saving functions | Backlight off: Disable/1 to 99 minutes; Auto shutdown: Disable/1 to 99 minutes |
| Battery pack Z0921A |
11.1 V, 4200 mAh
53 (W) × 19 (H) × 215 (D) mm, 330 g (typ.)
|
| AC adapter Z1625A rated DC output |
12 V(dc), 5 A
Rated AC input 100 V(ac) to 240 V(ac), 50 Hz/60 Hz
|
| Dimensions (without protector) | 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches |
|---|---|
| Mass (without protector) | 1.6 kg without battery, 1.9 kg including battery |
| Dimensions (with protector option 010) | 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches |
| Mass (with protector option 010) | 2.6 kg including battery |
| Operating temperature and humidity | –10°C to +50°C, <80% (non-condensing) |
|---|---|
| Storage temperature and humidity | –20°C to +60°C, <80% (non-condensing) |
| Vibration | Conforming to MIL-T-28800E Class 3 |
| Ingress protection rating | IEC60529 IP51 |
| Shock | MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off), Bump: IEC 60068-2-27, JIS C60068-2-27 |
| Shock-on-desk | MIL-T-28800E (45° angle or 100 mm lifted edge, 4 drops in total, power on) |
| CE EMC | 2014/30/EU, EN61326-1, EN61000-3-2 |
|---|---|
| CE LVD | 2014/35/EU, EN61010-1 |
| CE RoHS | 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018 |
| UKCA EMC | S.I. 2016 No.1091, EN 61326-1, EN61000-3-2 |
| UKCA LVD | S.I. 2016 No.1101, EN 61010-1 |
| UKCA RoHS | S.I. 2012 No.3032, EN IEC 63000:2018 |
Applications
- Installation and maintenance of trunk fibers
- Core and metro networks
- Mobile fronthaul and backhaul
- Access network troubleshooting
- Drop cable break location
- Macrobend analysis
- PON network measurement
- Premise fiber testing
- Optical connector end-face inspection
Included
- Z1991A MT9085 Operation Manual (CD)
- W3974AE MT9085 Series Quick Guide
- Z1625A AC adapter
- Line cord
- Z0921A Battery Pack
Options & Accessories
| Option | Description |
|---|---|
| MT9085A-025 | FC-APC Connector — Key width 2.0 mm; can only connect APC-type optical fiber |
| MT9085A-026 | SC-APC Connector — Can only connect APC-type optical fiber |
| MT9085A-037 | FC Connector |
| MT9085A-038 | ST Connector |
| MT9085A-039 | DIN47256 Connector |
| MT9085A-040 | SC Connector |
| MT9085A-002 | Visual Fault Locator — Visual light source for locating fiber breaks |
| MT9085A-004 | SMF Optical Power Meter — –50 to +23 dBm |
| MT9085A-005 | SMF High Power Optical Power Meter — –43 to +30 dBm |
| MT9085A-007 | SMF/MMF Optical Power Meter — –67 to +6 dBm |
| MT9085A-010 | Protector — Front Protector B0584A cover supplied with belt as standard |
| G0306C | Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation |
| W3971AE | MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| W3972AE | MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| B0745A | Softcase |
| B0582A | Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector |
| B0583A | Hard transit case — Dimensions 420 (W) × 330 (H) × 148(D) mm |
| B0549 | Hard carrying case |
| B0584A | Front cover — Option 010 Protector cover only |
| Z0921A | Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh |
| Z1632A | Battery Charger — Li-ion battery charger |
| J1295 | Car plug cord |
| J0617B | Replaceable optical connector (FC-PC) — For OTDR port, for option power meter port |
| J0618D | Replaceable optical connector (ST) — For OTDR port, for option power meter port |
| J0618F | Replaceable optical connector (HMS-10/A) — For OTDR port, for option power meter port |
| J0619B | Replaceable optical connector (SC-PC) — For OTDR port, for option power meter port |
| J0739A | Replaceable optical connector (FC-APC) — For OTDR port |
| J1697A | Replaceable optical connector (SC-APC) — For OTDR port |
| J0057 | Optical adapter FC type — FC-FC connector (JJ adapter) |
| J1335A | MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only) |
| MA9005B-37 | For FC connector — For option power meter port (MT9085A/B/C-005) |
| MA9005B-38 | For ST connector — For option power meter port (MT9085A/B/C-005) |
| MA9005B-40 | For SC connector — For option power meter port (MT9085A/B/C-005) |
| LP-FC | FC-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| LP-ST | ST-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| LP-SC | SC-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| J1530A | SC plug in converter (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC |
| J1531A | SC plug in converter (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC |
| J1532A | FC plug in converter (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC |
| J1533A | FC plug in converter (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC |
| J1534A | LC-SC Plug-in Converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only) |
| J1535A | LC-SC Plug-in Converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only) |
| Z0914A | Ferrule cleaner — 1 pc |
| Z0915A | Replacement reel for ferrule cleaner — 6 pcs for Z0914A |
| Z0284 | Adapter Cleaner — Stick type (200 pcs/set) |
| J1950A | USB-Ethernet converter — For remote GUI connection |
| NETWORKS | NETWORKS PC analysis software — OTDR waveform analysis and report creation on a Windows PC |