Anritsu ACCESS Master MT9085 series handheld OTDR front view
Anritsu / MT9085 Series / Handheld
MT9085A-057

ACCESS Master MT9085A-057 1310/1550/1625 nm SMF Handheld OTDR

Standard-class handheld ACCESS Master OTDR with 1310/1550/1625 nm single-mode wavelengths for macrobend analysis and fiber I&M.

Wavelength
1310/1550/1625 nm ±25 nm
Fiber type
Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width
3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic range
37/35.5/32.5 dB

Overview

The ACCESS Master MT9085A-057 is the Standard-class member of the Anritsu MT9085 series configured with a 1310/1550/1625 nm single-mode OTDR module. The 1625 nm wavelength supports maintenance inspection and macrobend analysis alongside the standard 1310 nm and 1550 nm test wavelengths. The unit is a compact handheld all-in-one tester for optical pulse tests, optical loss and power measurements, and optical fiber end-face inspection.

OTDR measurement

The optical pulse test measures fiber transmission loss and fiber length and detects events such as breaks in fiber continuity. The Fiber Visualizer function displays events such as splices, connectors, PON splitters and the fiber end as schematic icons, with distance, loss and reflectance Pass/Fail evaluation against preset thresholds. Two realtime sweep modes (high-speed and high S/N) help locate fiber bends and the far end before averaging. Manual analysis uses the rotary knob, hard keys and four-marker operation with 2-point and LSA methods, and the touchscreen can be operated with work gloves on.

Power, loss and end-face inspection

A stabilized light source and an optical power meter are built in through the OTDR port. Dedicated power meter options add optical loss test set (OLTS) operation on a separate port, and a visual fault locator option helps locate breaks. With the external G0306C Video Inspection Probe (sold separately), the unit inspects connector end faces and gives Pass/Fail evaluation in accordance with IEC61300-3-35.

Data management

Measurement data can be saved in original formats (.sor, .vipi), as .csv files, as screen captures or as PDF reports. Files can be transferred to a PC by USB memory, USB cable, Ethernet or WLAN through USB adapters. The unit can also be controlled remotely through a web browser GUI or remote commands. Other functions include Cable Certification Test, Scenario Manager Lite, bi-directional analysis, the Installation Test for multiple fibers, and password protection.

Key Features

  • 1310/1550/1625 nm single-mode OTDR supporting maintenance inspection wavelengths for microbend analysis
  • 8-inch LCD touchscreen with easy visibility even in direct sunlight
  • Operation through touchscreen, rotary knob and dedicated hard keys
  • Fiber Visualizer function for simple fiber path analysis with Pass/Fail evaluation
  • High-speed and high S/N real-time sweep modes for fast fiber bend location
  • Identification of each splitter event and up to 1 × 128 branches
  • Built-in stabilized light source and optical power meter through the OTDR port
  • Optional visual fault locator and optical power meter options
  • Optical fiber end-face inspection using external fiberscope option
  • Live fiber detection and OTDR connection check
  • Bi-directional measurement analysis
  • Cable Certification Test function with PDF report output
  • Scenario Manager Lite for automated test sequences without a PC
  • Telcordia SR-4731 trace format support
  • Remote control through web browser GUI and remote commands
  • Password protection function
  • 12-hour battery operation

Specifications

OTDR
Wavelength 1310/1550/1625 nm ±25 nm
25°C, pulse width: 1 μs
Fiber type Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic range 37/35.5/32.5 dB
Typical; subtract 1 dB for guarantee. Pulse width 20 μs, distance range 100 km, averaging 180 sec., SNR = 1, 25°C
Dead zone (Fresnel) ≤1 m, 0.8 m (typ.)
IOR = 1.500000; pulse width 3 ns, return loss 40 dB, 25°C
Dead zone (Backscatter) ≤6/6.5/7.5 m
IOR = 1.500000; pulse width 10 ns, return loss 55 dB, deviation ±0.5 dB, 25°C
Laser safety IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
Sampling points Up to 150,001
High density value is selected depending on distance range
Sampling resolution 0.05 m to 60 m
Distance range Single mode: 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km
Distance accuracy ±1 m ±3 × measurement distance × 10-5 ± marker resolution
Excluding IOR uncertainty
Reflectance accuracy Single mode: ±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, distance range: 50 km, pulse width: 2 μs
Loss measurement accuracy (linearity) ±0.05 dB/dB or ±0.1 dB (whichever is greater)
Vertical scale 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div
IOR setting 1.300000 to 1.700000 (0.000001 steps)
Units km, m, kft, ft, mi
Real time sweep 0.15 sec.
Resolution: Low Density
OTDR trace format Telcordia universal. SOR, issue 2 (SR-4731)
Fiber Event Analysis
Operation Auto or manual operation, displayed in table format
Pass/Fail threshold: reflective and non-reflective events 0.01 to 9.99 dB (0.01-dB steps)
User defined
Pass/Fail threshold: reflectance 70.0 to 20.0 dB (0.1-dB steps)
User defined
Pass/Fail threshold: fiber end/break 1 to 99 dB (1-dB steps)
User defined
Number of detected events up to 99
Loss modes 2-point loss, dB/km, 2-point LSA, splice loss, ORL
Averaging modes Timed (1 to 3600 s)
Light Source (Standard)
Type Stabilized Light Source (through OTDR port)
Wavelength Same as OTDR
CW, 25°C
Spectral width ≤5 nm (1310 nm), ≤10 nm (1550/1625 nm)
CW, 25°C
Wavelength accuracy ±30 nm
1310/1550/1625 nm; CW, 25°C
Output power –5 ±1.5 dBm
CW, 25°C
Output stability ≤0.1 dB
CW, –10°C to 50°C (±1°C), difference between max/min values over 1 minute, SM fiber 2 m
Modes of operation CW, 270 Hz, 1 kHz, 2 kHz
Modulation +1.5% with 10 minute warm up
Power Meter (Standard Integrated)
Port through OTDR port
Not available if Option 004, 005 or 007 is ordered
Maximum input +10 dBm
Measurement range –50 to –5 dBm
Accuracy ±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, using Anritsu's reference single mode fiber with FC/UPC connector
Setting wavelengths 1310, 1550, 1625, 1650 nm
Options 053, 055, 057, 063
Features Store reference, loss table
Loss Test Set (Optional Power Meters)
Measurement range
MT9085A-007
–67 to +6 dBm (CW, 1310 nm)
Peak power, subtract 3 dB for modulated tones; –60 to +3 dBm @850 nm
Measurement range
MT9085A-004
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Measurement range
MT9085A-005
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Wavelength range
MT9085A-007
800 nm to 1700 nm
Wavelength range
MT9085A-004, MT9085A-005
1200 nm to 1700 nm
Modulation CW, 270 Hz, 1 kHz, 2 kHz
Environmental Operating temperature and humidity: 0°C to +50°C, <80% (non-condensing)
Visual Light Source (Option 002)
Central wavelength
MT9085A-002
650 nm±15 nm (at 25˚C)
Optical output
MT9085A-002
0 ±3 dBm (CW)
Output optical fiber
MT9085A-002
10 μm/125 μm, SMF (ITU-T G.652)
Optical connector
MT9085A-002
2.5 mm universal
Laser safety
MT9085A-002
IEC 60825-1: 2014 CLASS 3R
General
Display 8-inch touch screen TFT-Color LCD
Interface USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
Wireless interface WLAN via USB adapter connected to USB port
Data storage Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB
Languages English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
Power
Power supply 12 V(dc), 100 V(ac) to 240 V(ac), Allowable input voltage range: 90 V to 264 V, 50 Hz/60 Hz
Battery type Lithium ion
Battery operating time 12 hours
Telcordia GR-196-CORE Issue 2, September 2010; typical, backlight Low, sweeping halted at 25˚C
Recharge time <5 hours (power off)
Power consumption 20 W max (recharging), 4 W standard (low backlight, sweep stopped)
Power saving functions Backlight off: Disable/1 to 99 minutes; Auto shutdown: Disable/1 to 99 minutes
Battery pack Z0921A 11.1 V, 4200 mAh
53 (W) × 19 (H) × 215 (D) mm, 330 g (typ.)
AC adapter Z1625A rated DC output 12 V(dc), 5 A
Rated AC input 100 V(ac) to 240 V(ac), 50 Hz/60 Hz
Physical
Dimensions (without protector) 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches
Mass (without protector) 1.6 kg without battery, 1.9 kg including battery
Dimensions (with protector option 010) 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches
Mass (with protector option 010) 2.6 kg including battery
Environmental
Operating temperature and humidity –10°C to +50°C, <80% (non-condensing)
Storage temperature and humidity –20°C to +60°C, <80% (non-condensing)
Vibration Conforming to MIL-T-28800E Class 3
Ingress protection rating IEC60529 IP51
Shock MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off), Bump: IEC 60068-2-27, JIS C60068-2-27
Shock-on-desk MIL-T-28800E (45° angle or 100 mm lifted edge, 4 drops in total, power on)
Compliance
CE EMC 2014/30/EU, EN61326-1, EN61000-3-2
CE LVD 2014/35/EU, EN61010-1
CE RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018
UKCA EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2
UKCA LVD S.I. 2016 No.1101, EN 61010-1
UKCA RoHS S.I. 2012 No.3032, EN IEC 63000:2018

Applications

  • Installation and maintenance of trunk fibers
  • Core and metro networks
  • Mobile fronthaul and backhaul
  • Access network troubleshooting
  • Drop cable break location
  • Macrobend analysis
  • PON network measurement
  • Premise fiber testing
  • Optical connector end-face inspection

Included

  • Z1991A MT9085 Operation Manual (CD)
  • W3974AE MT9085 Series Quick Guide
  • Z1625A AC adapter
  • Line cord
  • Z0921A Battery Pack

Options & Accessories

Option Description
MT9085A-025 FC-APC Connector — Key width 2.0 mm; can only connect APC-type optical fiber
MT9085A-026 SC-APC Connector — Can only connect APC-type optical fiber
MT9085A-037 FC Connector
MT9085A-038 ST Connector
MT9085A-039 DIN47256 Connector
MT9085A-040 SC Connector
MT9085A-002 Visual Fault Locator — Visual light source for locating fiber breaks
MT9085A-004 SMF Optical Power Meter — –50 to +23 dBm
MT9085A-005 SMF High Power Optical Power Meter — –43 to +30 dBm
MT9085A-007 SMF/MMF Optical Power Meter — –67 to +6 dBm
MT9085A-010 Protector — Front Protector B0584A cover supplied with belt as standard
G0306C Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation
W3971AE MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
W3972AE MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
B0745A Softcase
B0582A Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector
B0583A Hard transit case — Dimensions 420 (W) × 330 (H) × 148(D) mm
B0549 Hard carrying case
B0584A Front cover — Option 010 Protector cover only
Z0921A Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh
Z1632A Battery Charger — Li-ion battery charger
J1295 Car plug cord
J0617B Replaceable optical connector (FC-PC) — For OTDR port, for option power meter port
J0618D Replaceable optical connector (ST) — For OTDR port, for option power meter port
J0618F Replaceable optical connector (HMS-10/A) — For OTDR port, for option power meter port
J0619B Replaceable optical connector (SC-PC) — For OTDR port, for option power meter port
J0739A Replaceable optical connector (FC-APC) — For OTDR port
J1697A Replaceable optical connector (SC-APC) — For OTDR port
J0057 Optical adapter FC type — FC-FC connector (JJ adapter)
J1335A MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only)
MA9005B-37 For FC connector — For option power meter port (MT9085A/B/C-005)
MA9005B-38 For ST connector — For option power meter port (MT9085A/B/C-005)
MA9005B-40 For SC connector — For option power meter port (MT9085A/B/C-005)
LP-FC FC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-ST ST-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-SC SC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
J1530A SC plug in converter (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC
J1531A SC plug in converter (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC
J1532A FC plug in converter (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC
J1533A FC plug in converter (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC
J1534A LC-SC Plug-in Converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only)
J1535A LC-SC Plug-in Converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only)
Z0914A Ferrule cleaner — 1 pc
Z0915A Replacement reel for ferrule cleaner — 6 pcs for Z0914A
Z0284 Adapter Cleaner — Stick type (200 pcs/set)
J1950A USB-Ethernet converter — For remote GUI connection
NETWORKS NETWORKS PC analysis software — OTDR waveform analysis and report creation on a Windows PC

Documents & Resources