Anritsu ACCESS Master MT9085 series handheld OTDR, front view
Anritsu / MT9085 Series / Handheld
MT9085A-053

ACCESS Master MT9085A-053 Handheld OTDR, 1310/1550 nm Single Mode, Standard Dynamic Range

Handheld all-in-one OTDR with 1310/1550 nm single-mode testing, 39/37.5 dB dynamic range, built-in light source and power meter

Wavelength
1310/1550 nm ±25 nm
Fiber type
Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width
3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic range
39/37.5 dB

Overview

The ACCESS Master MT9085A-053 is the standard-dynamic-range, general-purpose model of the Anritsu MT9085 series. It is a compact handheld all-in-one tester that combines an optical time domain reflectometer (OTDR) at 1310/1550 nm on single-mode fiber with optical loss and power measurement. With the external fiberscope option, it also inspects optical fiber end faces. Anritsu positions it as the standard model for installation and maintenance (I&M) in general-purpose, premise, access and metro applications.

Optical pulse test (OTDR)

The OTDR measures fiber transmission loss and length and detects events such as breaks in fiber continuity. The Fiber Visualizer function shows splices, connectors, splitters and the fiber end as schematic icons, with distance, loss and reflectance Pass/Fail results. Two real-time sweep modes, high-speed and high S/N, help locate fiber bends while the waveform is monitored. For manual analysis, the instrument offers the rotary knob, dedicated hard keys and four-marker loss and reflectance analysis from earlier ACCESS Master models, together with an 8-inch touchscreen.

Optical power, loss and end-face inspection

A stabilized light source and an optical power meter are built in as standard and use the OTDR port. Optional dedicated power meter ports, a visual fault locator and the G0306C Video Inspection Probe add optical loss testing (OLTS), visual fiber break location and IEC 61300-3-35 end-face Pass/Fail evaluation.

Data management

Measurements can be saved in original formats (Telcordia .sor for OTDR, .vipi for VIP), as .csv files, as screen captures or as PDF reports. Data can be transferred by USB memory, USB cable, or by WLAN or Ethernet through USB adapters. The instrument can be controlled remotely through a web-browser GUI or remote commands.

Key Features

  • 8-inch touchscreen TFT color LCD readable in direct sunlight
  • Touchscreen operation combined with rotary knob and dedicated hard keys
  • Pressure-sensitive touchscreen usable without removing work gloves
  • Fiber Visualizer displays fiber events as schematic icons with Pass/Fail evaluation
  • High-speed and high S/N real-time sweep modes for fiber bend location
  • PON splitter event identification for up to 1 × 128 branches
  • Built-in stabilized light source and optical power meter through the OTDR port
  • Optional visual fault locator and dedicated optical power meter ports
  • Optical fiber end-face inspection with the external G0306C Video Inspection Probe
  • Installation Test function for automatic measurement of multiple fibers
  • Bi-directional trace analysis for accurate splice loss
  • Cable Certification Test with automatic Pass/Fail to IEC/ISO standards
  • Scenario Manager Lite for automated test execution without a PC
  • Live fiber detection and OTDR connection check
  • Telcordia SR-4731 .sor trace format support
  • 1 GB internal memory for up to 50,000 traces
  • 12-hour battery operation
  • Password protection function
  • Remote control via web-browser GUI and remote commands

Specifications

OTDR
Wavelength 1310/1550 nm ±25 nm
25°C, pulse width: 1 μs
Fiber type Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic range 39/37.5 dB
Typical. Subtract 1 dB for guarantee. Pulse width 20 μs, distance range 100 km, averaging 180 sec., SNR = 1, 25°C
Dead zone (Fresnel) ≤1 m, 0.8 m (typ.)
IOR = 1.500000; pulse width 3 ns, return loss 40 dB, 25°C
Dead zone (backscatter) ≤5/5.5 m
IOR = 1.500000; pulse width 10 ns, return loss 55 dB, deviation ±0.5 dB, 25°C
Distance range (single mode) 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km
Sampling points Up to 150,001
Either high density value is selected depending on distance range
Sampling resolution 0.05 m to 60 m
Reflectance accuracy (single mode) ±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, distance range: 50 km, pulse width: 2 μs
Distance accuracy ±1 m ±3 × measurement distance × 10^-5 ± marker resolution
Excluding IOR uncertainty
Loss measurement accuracy (linearity) ±0.05 dB/dB or ±0.1 dB (whichever is greater)
Vertical scale 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div
IOR setting 1.300000 to 1.700000 (0.000001 steps)
Units km, m, kft, ft, mi
Real time sweep 0.15 sec.
Resolution: Low Density
OTDR trace format Telcordia universal. SOR, issue 2 (SR-4731)
Laser safety IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
Fiber Event Analysis
Operation Auto or manual operation, displayed in table format
Pass/Fail threshold: reflective and non-reflective events 0.01 to 9.99 dB (0.01-dB steps)
User defined
Pass/Fail threshold: reflectance 70.0 to 20.0 dB (0.1-dB steps)
User defined
Pass/Fail threshold: fiber end/break 1 to 99 dB (1-dB steps)
User defined
Number of detected events up to 99
Loss modes 2-point loss, dB/km, 2-point LSA, splice loss, ORL
Averaging modes Timed (1 to 3600 s)
Stabilized Light Source (through OTDR port, standard)
Wavelength Same as OTDR
CW, 25°C
Spectral width ≤5 nm (1310 nm), ≤10 nm (1550 nm)
CW, 25°C
Wavelength accuracy ±30 nm
1310/1550 nm; CW, 25°C
Output power –5 ±1.5 dBm
CW, 25°C
Output stability ≤0.1 dB
CW, –10°C to 50°C (±1°C), difference between max/min values over 1 minute, SM fiber 2 m
Modes of operation CW, 270 Hz, 1 kHz, 2 kHz
Modulation +1.5% with 10 minute warm up
Integrated Power Meter (through OTDR port, standard)
Maximum input +10 dBm
Not available if Option 004, 005 or 007 is ordered
Measurement range –50 to –5 dBm
Accuracy ±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, Anritsu reference single mode fiber with FC/UPC connector
Setting wavelengths 1310, 1550, 1625, 1650 nm
Options 053, 055, 057, 063
Features Store reference, loss table
Optional Power Meters (Loss Test Set)
Measurement range
MT9085A-004
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Measurement range
MT9085A-005
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Measurement range
MT9085A-007
–67 to +6 dBm (CW, 1310 nm)
–60 to +3 dBm at 850 nm; peak power, subtract 3 dB for modulated tones
Modulation CW, 270 Hz, 1 kHz, 2 kHz
Operating temperature and humidity 0°C to +50°C, <80% (non-condensing)
Visual Light Source (Option 002)
Central wavelength
MT9085A-002
650 nm±15 nm (at 25˚C)
Optical output
MT9085A-002
0 ±3 dBm (CW)
Optical connector
MT9085A-002
2.5 mm universal
Laser safety
MT9085A-002
IEC 60825-1: 2014 CLASS 3R
Display, Interfaces and Storage
Display 8-inch touch screen TFT-Color LCD
Interface USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
Wireless interface WLAN via USB adapter connected to USB port
Data storage Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB
Languages English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
Power
Power supply 12 V(dc), 100 V(ac) to 240 V(ac), 50 Hz/60 Hz
Allowable input voltage range: 90 V to 264 V
Battery type Lithium ion
Battery Pack Z0921A, 11.1 V, 4200 mAh
Battery operating time 12 hours
Typical, backlight Low, sweeping halted at 25˚C; Telcordia GR-196-CORE Issue 2, September 2010
Recharge time <5 hours (power off)
Power consumption 20 W max (recharging), 4 W standard (low backlight, sweep stopped)
Power saving functions Backlight off: Disable/1 to 99 minutes; Auto shutdown: Disable/1 to 99 minutes
Physical
Dimensions (without protector) 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches
Mass (without protector) 1.6 kg without battery, 1.9 kg including battery
Dimensions (with protector) 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches
Option 010
Mass (with protector) 2.6 kg including battery
Option 010
Environmental and Compliance
Operating temperature and humidity –10°C to +50°C, <80% (non-condensing)
Storage temperature and humidity –20°C to +60°C, <80% (non-condensing)
Vibration Conforming to MIL-T-28800E Class 3
Ingress protection rating IEC60529 IP51
Shock MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off)
Bump: IEC 60068-2-27, JIS C60068-2-27
CE EMC 2014/30/EU, EN61326-1, EN61000-3-2; LVD 2014/35/EU, EN61010-1; RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018
UKCA EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2; LVD S.I. 2016 No.1101, EN 61010-1; RoHS S.I. 2012 No.3032, EN IEC 63000:2018

Applications

  • Installation and maintenance of optical fiber networks
  • Premise fiber networks
  • Access network troubleshooting
  • Metro networks
  • Mobile fronthaul and backhaul
  • Drop cable break location
  • PON splitter analysis
  • Optical loss and power measurement
  • Fiber end-face inspection

Included

  • Z1991A MT9085 Operation Manual (CD): 1 pc
  • W3974AE MT9085 Series Quick Guide: 1 pc
  • Z1625A AC adapter: 1 pc
  • Line cord: 1 pc
  • Z0921A Battery Pack: 1 pc

Options & Accessories

Option Description
MT9085A-025 FC-APC Connector — Key width 2.0 mm. Can only connect APC-type optical fiber
MT9085A-026 SC-APC Connector — Can only connect APC-type optical fiber
MT9085A-037 FC Connector
MT9085A-038 ST Connector
MT9085A-040 SC Connector
MT9085A-002 Visual Fault Locator — Visible red light for fiber identification and troubleshooting
MT9085A-004 SMF Optical Power Meter — –50 to +23 dBm
MT9085A-005 SMF High Power Optical Power Meter — –43 to +30 dBm
MT9085A-007 SMF/MMF Optical Power Meter — –67 to +6 dBm
MT9085A-010 Protector — Front Protector B0584A cover supplied with belt as standard
G0306C Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation
W3971AE MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
W3972AE MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
B0745A Softcase
B0582A Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector
B0583A Hard transit case — Dimensions 420 (W) × 330 (H) × 148(D) mm
B0549 Hard carrying case
B0584A Front cover — Option 010 Protector cover only
Z0921A Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh
Z1632A Battery Charger — Li-ion battery charger
J1295 Car plug cord
J0617B Replaceable optical connector (FC-PC) — For OTDR port, for option power meter port
J0618D Replaceable optical connector (ST) — For OTDR port, for option power meter port
J0618F Replaceable optical connector (HMS-10/A) — For OTDR port, for option power meter port
J0619B Replaceable optical connector (SC-PC) — For OTDR port, for option power meter port
J0739A Replaceable optical connector (FC-APC) — For OTDR port
J1697A Replaceable optical connector (SC-APC) — For OTDR port
J0057 Optical adapter FC type — FC-FC connector (JJ adapter)
J1335A MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only)
MA9005B-37 For FC connector — For option power meter port (MT9085A/B/C-005)
MA9005B-38 For ST connector — For option power meter port (MT9085A/B/C-005)
MA9005B-40 For SC connector — For option power meter port (MT9085A/B/C-005)
LP-FC FC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-ST ST-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-SC SC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
J1530A SC plug in converter (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC
J1531A SC plug in converter (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC
J1532A FC plug in converter (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC
J1533A FC plug in converter (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC
J1534A LC-SC Plug-in Converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only)
J1535A LC-SC Plug-in Converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only)
Z0914A Ferrule cleaner — 1 pc
Z0915A Replacement reel for ferrule cleaner — 6 pcs for Z0914A
Z0284 Adapter Cleaner — Stick type (200 pcs/set)
J1950A USB-Ethernet converter — For remote GUI connection
NETWORKS NETWORKS PC analysis software — OTDR waveform analysis of .sor files and report creation on a Windows PC

Documents & Resources