VectorStar ME7838D Broadband Vector Network Analyzer System, 70 kHz to 145 GHz
Broadband 2-port VNA system with single-sweep coverage from 70 kHz to 145 GHz through a 0.8 mm coaxial test port, extendable to 1.1 THz in waveguide bands.
- VNA
- MS4647B VectorStar VNA, 70 kHz to 70 GHz with Option 7, Option 70, and Option 80/81
- Test Set
- 3739C Broadband Test Set and interface cables
- mmWave Modules
- MA25300A Millimeter-Wave Module, 2 each
- Test port connector
- 0.8 mm
Overview
The VectorStar ME7838D is a broadband vector network analyzer system that provides single-sweep coverage from 70 kHz to 145 GHz and is operational from 40 kHz to 145 GHz. It uses the Anritsu-developed 0.8 mm coaxial connector, so frequencies up to 145 GHz propagate in a coaxial line without waveguide flange connections. Devices can be characterized from near-DC through the W band and F band in one sweep, without concatenating multiple systems.
The broadband system consists of an MS4647B VectorStar VNA (70 kHz to 70 GHz, with Option 7, Option 70 and Option 80/81), a 3739C Broadband Millimeter-Wave Test Set with interface cables, and two MA25300A millimeter-wave modules. The modules use Anritsu nonlinear transmission line (NLTL) technology. They are small and light enough to position precisely on a wafer probe station, and they level power in real time without calibration software correction tables.
Waveguide bands
A millimeter-wave configuration provides waveguide output from 50 GHz to 1.1 THz. It can extend the broadband system or run as a waveguide-only system. Supported waveguide setups include adapting the MA25300A module with waveguide adapters, the 3744A-EE and 3744A-EW extended E- and W-band modules, and VDI frequency extension modules.
Measurement capabilities
The ME7838D supports the 3744A-Rx 30 GHz to 125 GHz receiver for noise figure measurements up to 125 GHz. Option 48 adds differential noise figure. Other options include time domain, Universal Fixture Extraction, DifferentialView, IMDView, PulseView, eye diagram and spectrum analysis. SC8215 and SC7287 Kelvin bias tees support tri-axial bias connections for on-wafer device biasing up to 145 GHz.
Key Features
- Single-sweep broadband coverage from 70 kHz to 145 GHz, operational from 40 kHz
- 0.8 mm coaxial test ports, no waveguide flange connections needed up to 145 GHz
- Millimeter-wave waveguide coverage from 50 GHz to 1.1 THz
- Calibration and measurement stability of 0.1 dB over 24 hrs
- Measurement speed of 55 ms for 201 points at 10 kHz IFBW
- Compact MA25300A NLTL millimeter-wave modules for wafer probe station positioning
- Real-time power leveling at millimeter-wave frequencies without calibration software correction tables
- Supports the 3744A-Rx receiver for noise figure measurements up to 125 GHz
- Differential noise figure measurements with Option 48
- Supports tri-axial Kelvin bias tee connections for on-wafer device biasing up to 145 GHz
- Spectrum analyzer option (Option 49) available across the broadband range
- ME7838AX 125 GHz broadband system can be upgraded to 145 GHz by adding the MA25300A mmWave module
Specifications
| VNA |
MS4647B VectorStar VNA, 70 kHz to 70 GHz with Option 7, Option 70, and Option 80/81
Support for the MS464xA VectorStar is available.
|
|---|---|
| Test Set | 3739C Broadband Test Set and interface cables |
| mmWave Modules | MA25300A Millimeter-Wave Module, 2 each |
| Test port connector | 0.8 mm |
| Broadband frequency range |
70 kHz to 145 GHz
Single sweep coverage
|
|---|---|
| Operational frequency range |
40 kHz to 145 GHz
Page 2 of the datasheet states operational from 40 kHz to 150 GHz
|
| Millimeter waveguide frequency range |
50 GHz to 1.1 THz
In waveguide bands
|
| Frequency resolution | 1 Hz |
| Frequency accuracy |
± 5 x 10–7 Hz/Hz
At time of calibration
|
| Frequency stability | < 5 x 10–9/°C over 0 °C to 50 °C temperature; < 1 x 10–9/day aging, instrument on |
| 70 kHz to 300 kHz |
93 dB
Typical; Option 62: 90 dB. Excludes localized spurious responses and crosstalk.
|
|---|---|
| > 0.01 to < 2.5 GHz |
120 dB
Typical; Option 62: 116 dB
|
| > 24 to 54 GHz |
110 dB
Typical; Option 62: 107 dB
|
| > 67 to 80 GHz |
108 dB
Typical; Option 62: 108 dB
|
| > 105 to 110 GHz |
109 dB
Typical; Option 62: 109 dB
|
| > 120 to 125 GHz |
104 dB
Typical; Option 62: 104 dB
|
| > 140 to 145 GHz |
94 dB
Typical; Option 62: 94 dB
|
| > 0.01 to < 2.5 GHz |
–110 dBm
Typical; Option 62: –109 dBm
|
|---|---|
| > 24 to 54 GHz |
–115 dBm
Typical; Option 62: –115 dBm
|
| > 105 to 110 GHz |
–115 dBm
Typical; Option 62: –115 dBm
|
| > 140 to 145 GHz |
–100 dBm
Typical; Option 62: –100 dBm
|
| Max power, 70 kHz to 300 kHz |
10 dBm
Typical; Option 62: 8 dBm
|
|---|---|
| Max power, > 24 to 54 GHz |
–5 dBm
Typical; Option 62: –8 dBm
|
| Max power, > 105 to 110 GHz |
–6 dBm
Typical
|
| Max power, > 140 to 145 GHz |
–6 dBm
Typical
|
| Power range, > 54 to 60 GHz |
–55 to –4
Typical; accuracy ±2.0 dB, linearity ±1.5 dB
|
| Power range, > 140 to 145 GHz |
–50 to –6
Typical; accuracy ±5.0 dB, linearity ±4.0 dB
|
| Power resolution | 0.01 |
| Directivity, 70 kHz to 10 MHz |
36 dB
Typical; source match 36 dB, load match 36 dB
|
|---|---|
| Directivity, 2.5 to 20 GHz |
40 dB
Typical; source match 41 dB, load match 40 dB
|
| Directivity, > 95 to 110 GHz |
34 dB
Typical; source match 37 dB, load match 34 dB
|
| Directivity, > 140 to 145 GHz |
26 dB
Typical; source match 28 dB, load match 26 dB
|
| Measurement speed | 55 ms for 201 points at 10 kHz IFBW |
|---|---|
| Measurement time, 2-port calibration, 401 points, 10 kHz IFBW |
220 ms
Typical; full band 70 kHz to 145 GHz, display on, ALC on
|
| Calibration and measurement stability | 0.1 dB over 24 hrs |
| Recommended calibration cycle | 12 months |
| MS4640B VNA weight |
< 28 kg (< 62 lbs)
Typical weight for a fully-loaded MS4647B VNA
|
|---|---|
| MS4640B VNA height |
267 mm body (6u)
Without rack mount option
|
| 3739C Test Set weight | 5.75 kg (12.7 lbs) |
| MA25300A module dimensions (H x W x D) | 26.6 mm x 54 mm x 72.4 mm |
| MA25300A module weight | 0.22 kg |
| Operating standard | Conforms to MIL-PRF-28800F (Class 3) |
|---|---|
| Operating temperature |
0 ºC to +50 ºC
Without error codes, except for 'unleveled' error messages that may occur at the extreme edges of the range
|
| Operating relative humidity | 5 % to 95 % at +30 ºC, Non-condensing |
| Non-operating temperature | –40 ºC to +71 ºC |
| Altitude | 4,600 m (15,000 ft) |
| Warranty | 1-year warranty from the date of shipment (excluding VDI modules) |
|---|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- On-wafer device characterization
- Device modeling
- W band and F band device characterization
- Millimeter-wave noise figure measurements
- Differential noise figure measurements
- Millimeter-wave antenna measurements
- Signal integrity measurements
- Optoelectronic measurements
- Material measurements
- Spectrum analysis of harmonics, spurs and distortion products
Included
- MS4647B VectorStar VNA, 70 kHz to 70 GHz, with Option 7, Option 70, and Option 80/81
- 3739C Broadband Millimeter-Wave Test Set and Interface Cables
- MA25300A Millimeter-Wave Module, 2 each
Options & Accessories
| Option | Description |
|---|---|
| MS4640B-002 | Time Domain |
| MS4640B-021 | Universal Fixture Extraction |
| MS464xB-031 | Dual Source Architecture |
| MS464xB-032 | Internal RF Combiner |
| MS4640B-041 | Noise Figure |
| MS4640B-042 | PulseView™ |
| MS4640B-043 | DifferentialView™ |
| MS4640B-044 | IMDView™ |
| MS4640B-046 | Fast CW |
| MS4640B-047 | Eye Diagram |
| MS4640B-048 | Differential Noise Figure |
| MS4640B-049 | Spectrum Analysis |
| MS464xB-051 | External VNA Direct Access Loops |
| MS464xB-061 | Active Measurement Suite, with 2 Attenuators |
| MS464xB-062 | Active Measurement Suite, with 4 Attenuators |
| MS4647B-080 | MS4647B with ME7838D system option — MS4647B-084 is ordered when Option 31 is included. |
| MS4647B-081 | MS4647B with ME7838D system option and Option 51 or 61 or 62 — MS4647B-085 is ordered when Option 31 is included. |
| ME7838D-SS020 | On-site system assembly and verification |
| 806-206-R | 1.85 mm coaxial VNA RF cables, 24", M-F, 2 each |
| 806-209-R | 1.85 mm coaxial VNA RF cables, 36", M-F, 2 each |
| 3744A-Rx | 30 to 110 GHz mmWave Receiver for Noise Figure and mmWave Antenna Measurements — Used with Option 41 for mmWave noise figure measurements from 30 GHz to 125 GHz. |
| 3744A-EE | 56 to 95 GHz WR-12 Waveguide Module |
| 3744A-EW | 65 to 110 GHz WR-10 Waveguide Module |
| SC8215 | Kelvin Bias Tee — V-connectorized bias tee usable with the ME7838D mmWave modules for system frequencies of 70 kHz to 145 (150) GHz. Max Voltage: 16 VDC, Max Current: 100 mA. |
| SC7287 | Kelvin Bias Tee — V-connectorized bias tee usable with the ME7838D mmWave modules for system frequencies of 100 MHz to 145 (150) GHz. Max Voltage: 50 VDC, Max Current: 500 mA. |
| 3659 | 0.8 mm Calibration/Verification Kit — Provides 12-term SOLT or Triple Offset Short calibrations for 0.8 mm devices, and two verification standards. |
| 3670.850-1 | 0.8 mm Test Port Cable, 10 cm — DC to 145 GHz |
| 3670.850-2 | 0.8 mm Test Port Cable, 16 cm — DC to 145 GHz |