Anritsu VectorStar ME7838 Series broadband VNA system
Anritsu / ME7838 Series / Broadband
ME7838D

VectorStar ME7838D Broadband Vector Network Analyzer System, 70 kHz to 145 GHz

Broadband 2-port VNA system with single-sweep coverage from 70 kHz to 145 GHz through a 0.8 mm coaxial test port, extendable to 1.1 THz in waveguide bands.

VNA
MS4647B VectorStar VNA, 70 kHz to 70 GHz with Option 7, Option 70, and Option 80/81
Test Set
3739C Broadband Test Set and interface cables
mmWave Modules
MA25300A Millimeter-Wave Module, 2 each
Test port connector
0.8 mm
Datasheet

Overview

The VectorStar ME7838D is a broadband vector network analyzer system that provides single-sweep coverage from 70 kHz to 145 GHz and is operational from 40 kHz to 145 GHz. It uses the Anritsu-developed 0.8 mm coaxial connector, so frequencies up to 145 GHz propagate in a coaxial line without waveguide flange connections. Devices can be characterized from near-DC through the W band and F band in one sweep, without concatenating multiple systems.

The broadband system consists of an MS4647B VectorStar VNA (70 kHz to 70 GHz, with Option 7, Option 70 and Option 80/81), a 3739C Broadband Millimeter-Wave Test Set with interface cables, and two MA25300A millimeter-wave modules. The modules use Anritsu nonlinear transmission line (NLTL) technology. They are small and light enough to position precisely on a wafer probe station, and they level power in real time without calibration software correction tables.

Waveguide bands

A millimeter-wave configuration provides waveguide output from 50 GHz to 1.1 THz. It can extend the broadband system or run as a waveguide-only system. Supported waveguide setups include adapting the MA25300A module with waveguide adapters, the 3744A-EE and 3744A-EW extended E- and W-band modules, and VDI frequency extension modules.

Measurement capabilities

The ME7838D supports the 3744A-Rx 30 GHz to 125 GHz receiver for noise figure measurements up to 125 GHz. Option 48 adds differential noise figure. Other options include time domain, Universal Fixture Extraction, DifferentialView, IMDView, PulseView, eye diagram and spectrum analysis. SC8215 and SC7287 Kelvin bias tees support tri-axial bias connections for on-wafer device biasing up to 145 GHz.

Key Features

  • Single-sweep broadband coverage from 70 kHz to 145 GHz, operational from 40 kHz
  • 0.8 mm coaxial test ports, no waveguide flange connections needed up to 145 GHz
  • Millimeter-wave waveguide coverage from 50 GHz to 1.1 THz
  • Calibration and measurement stability of 0.1 dB over 24 hrs
  • Measurement speed of 55 ms for 201 points at 10 kHz IFBW
  • Compact MA25300A NLTL millimeter-wave modules for wafer probe station positioning
  • Real-time power leveling at millimeter-wave frequencies without calibration software correction tables
  • Supports the 3744A-Rx receiver for noise figure measurements up to 125 GHz
  • Differential noise figure measurements with Option 48
  • Supports tri-axial Kelvin bias tee connections for on-wafer device biasing up to 145 GHz
  • Spectrum analyzer option (Option 49) available across the broadband range
  • ME7838AX 125 GHz broadband system can be upgraded to 145 GHz by adding the MA25300A mmWave module

Specifications

System Configuration
VNA MS4647B VectorStar VNA, 70 kHz to 70 GHz with Option 7, Option 70, and Option 80/81
Support for the MS464xA VectorStar is available.
Test Set 3739C Broadband Test Set and interface cables
mmWave Modules MA25300A Millimeter-Wave Module, 2 each
Test port connector 0.8 mm
Frequency
Broadband frequency range 70 kHz to 145 GHz
Single sweep coverage
Operational frequency range 40 kHz to 145 GHz
Page 2 of the datasheet states operational from 40 kHz to 150 GHz
Millimeter waveguide frequency range 50 GHz to 1.1 THz
In waveguide bands
Frequency resolution 1 Hz
Frequency accuracy ± 5 x 10–7 Hz/Hz
At time of calibration
Frequency stability < 5 x 10–9/°C over 0 °C to 50 °C temperature; < 1 x 10–9/day aging, instrument on
System Dynamic Range
70 kHz to 300 kHz 93 dB
Typical; Option 62: 90 dB. Excludes localized spurious responses and crosstalk.
> 0.01 to < 2.5 GHz 120 dB
Typical; Option 62: 116 dB
> 24 to 54 GHz 110 dB
Typical; Option 62: 107 dB
> 67 to 80 GHz 108 dB
Typical; Option 62: 108 dB
> 105 to 110 GHz 109 dB
Typical; Option 62: 109 dB
> 120 to 125 GHz 104 dB
Typical; Option 62: 104 dB
> 140 to 145 GHz 94 dB
Typical; Option 62: 94 dB
Noise Floor
> 0.01 to < 2.5 GHz –110 dBm
Typical; Option 62: –109 dBm
> 24 to 54 GHz –115 dBm
Typical; Option 62: –115 dBm
> 105 to 110 GHz –115 dBm
Typical; Option 62: –115 dBm
> 140 to 145 GHz –100 dBm
Typical; Option 62: –100 dBm
Test Port Power
Max power, 70 kHz to 300 kHz 10 dBm
Typical; Option 62: 8 dBm
Max power, > 24 to 54 GHz –5 dBm
Typical; Option 62: –8 dBm
Max power, > 105 to 110 GHz –6 dBm
Typical
Max power, > 140 to 145 GHz –6 dBm
Typical
Power range, > 54 to 60 GHz –55 to –4
Typical; accuracy ±2.0 dB, linearity ±1.5 dB
Power range, > 140 to 145 GHz –50 to –6
Typical; accuracy ±5.0 dB, linearity ±4.0 dB
Power resolution 0.01
Corrected System Performance (SOLT/SSST, 3659 0.8 mm Calibration Kit)
Directivity, 70 kHz to 10 MHz 36 dB
Typical; source match 36 dB, load match 36 dB
Directivity, 2.5 to 20 GHz 40 dB
Typical; source match 41 dB, load match 40 dB
Directivity, > 95 to 110 GHz 34 dB
Typical; source match 37 dB, load match 34 dB
Directivity, > 140 to 145 GHz 26 dB
Typical; source match 28 dB, load match 26 dB
Measurement Speed and Stability
Measurement speed 55 ms for 201 points at 10 kHz IFBW
Measurement time, 2-port calibration, 401 points, 10 kHz IFBW 220 ms
Typical; full band 70 kHz to 145 GHz, display on, ALC on
Calibration and measurement stability 0.1 dB over 24 hrs
Recommended calibration cycle 12 months
Physical
MS4640B VNA weight < 28 kg (< 62 lbs)
Typical weight for a fully-loaded MS4647B VNA
MS4640B VNA height 267 mm body (6u)
Without rack mount option
3739C Test Set weight 5.75 kg (12.7 lbs)
MA25300A module dimensions (H x W x D) 26.6 mm x 54 mm x 72.4 mm
MA25300A module weight 0.22 kg
Environmental
Operating standard Conforms to MIL-PRF-28800F (Class 3)
Operating temperature 0 ºC to +50 ºC
Without error codes, except for 'unleveled' error messages that may occur at the extreme edges of the range
Operating relative humidity 5 % to 95 % at +30 ºC, Non-condensing
Non-operating temperature –40 ºC to +71 ºC
Altitude 4,600 m (15,000 ft)
Warranty
Warranty 1-year warranty from the date of shipment (excluding VDI modules)

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • On-wafer device characterization
  • Device modeling
  • W band and F band device characterization
  • Millimeter-wave noise figure measurements
  • Differential noise figure measurements
  • Millimeter-wave antenna measurements
  • Signal integrity measurements
  • Optoelectronic measurements
  • Material measurements
  • Spectrum analysis of harmonics, spurs and distortion products

Included

  • MS4647B VectorStar VNA, 70 kHz to 70 GHz, with Option 7, Option 70, and Option 80/81
  • 3739C Broadband Millimeter-Wave Test Set and Interface Cables
  • MA25300A Millimeter-Wave Module, 2 each

Options & Accessories

Option Description
MS4640B-002 Time Domain
MS4640B-021 Universal Fixture Extraction
MS464xB-031 Dual Source Architecture
MS464xB-032 Internal RF Combiner
MS4640B-041 Noise Figure
MS4640B-042 PulseView™
MS4640B-043 DifferentialView™
MS4640B-044 IMDView™
MS4640B-046 Fast CW
MS4640B-047 Eye Diagram
MS4640B-048 Differential Noise Figure
MS4640B-049 Spectrum Analysis
MS464xB-051 External VNA Direct Access Loops
MS464xB-061 Active Measurement Suite, with 2 Attenuators
MS464xB-062 Active Measurement Suite, with 4 Attenuators
MS4647B-080 MS4647B with ME7838D system option — MS4647B-084 is ordered when Option 31 is included.
MS4647B-081 MS4647B with ME7838D system option and Option 51 or 61 or 62 — MS4647B-085 is ordered when Option 31 is included.
ME7838D-SS020 On-site system assembly and verification
806-206-R 1.85 mm coaxial VNA RF cables, 24", M-F, 2 each
806-209-R 1.85 mm coaxial VNA RF cables, 36", M-F, 2 each
3744A-Rx 30 to 110 GHz mmWave Receiver for Noise Figure and mmWave Antenna Measurements — Used with Option 41 for mmWave noise figure measurements from 30 GHz to 125 GHz.
3744A-EE 56 to 95 GHz WR-12 Waveguide Module
3744A-EW 65 to 110 GHz WR-10 Waveguide Module
SC8215 Kelvin Bias Tee — V-connectorized bias tee usable with the ME7838D mmWave modules for system frequencies of 70 kHz to 145 (150) GHz. Max Voltage: 16 VDC, Max Current: 100 mA.
SC7287 Kelvin Bias Tee — V-connectorized bias tee usable with the ME7838D mmWave modules for system frequencies of 100 MHz to 145 (150) GHz. Max Voltage: 50 VDC, Max Current: 500 mA.
3659 0.8 mm Calibration/Verification Kit — Provides 12-term SOLT or Triple Offset Short calibrations for 0.8 mm devices, and two verification standards.
3670.850-1 0.8 mm Test Port Cable, 10 cm — DC to 145 GHz
3670.850-2 0.8 mm Test Port Cable, 16 cm — DC to 145 GHz

Documents & Resources

VectorStar ME7838D Series Technical Data Sheet
datasheet · PDF
VectorStar MS464xB Series Microwave Vector Network Analyzer Technical Data Sheet
datasheet · PDF
0.8 mm Connectors, 0.8 Adapters, and Terminations Technical Data Sheet
datasheet · PDF
VectorStar MS464xB Product Information, Compliance, and Safety
other · PDF
EU Declaration of Conformity for VectorStar Broadband VNA
other · PDF
VectorStar ME7838D/G 2-Port Broadband/Banded Millimeter-Wave System Quick Start Guide
manual
VectorStar Broadband/Banded Millimeter-Wave Module Reference Manual
manual
VectorStar ME7838 Series 2-Port Broadband and Banded Millimeter-Wave System Installation Guide
manual
VectorStar ME7838 Series 2-Port Broadband/Banded Millimeter-Wave VNA Maintenance Manual
manual
VectorStar ME7838x mm-Wave Noise Figure Measurements Measurement Guide
manual
3659 0.8 mm Calibration/Verification Kit and 2300-580-R System Performance Verification Software User Guide
manual
VectorStar MS464xB Programming Manual
manual
0.8 mm Connectors Enable D-Band Coaxial Measurements Article
app note
145 GHz Optical-to-Electrical Measurement Solution Application Flyer
app note
Probe-Tip Power Calibrations with the Broadband ME7838 VNA Systems Application Note
app note
On-Wafer Biasing Using Anritsu Kelvin Bias Tees on VectorStar ME7838x Broadband Systems Application Note
app note
Procedure for a Higher Accuracy Receiver Calibration for Use in mm-Wave Noise Figure Measurements Application Note
app note
Millimeter-Wave Measurement Challenges Application Brief
app note
On-wafer Device Characterization Measurement Challenges Application Brief
app note
VectorStar VNA Spectrum Analyzer Option 49 Application Flyer
brochure
Vector Network Analysis Product Portfolio
brochure
Millimeter Wave Measurement Solutions
brochure