Simple Conformance Test System ME7800L for LTE, Cat-M1 and NB-IoT RF and Protocol Testing
RF/RRM and protocol conformance test system for 3GPP LTE mobile terminals, including Cat-M1 and NB-IoT, approved by GCF/PTCRB.
- Supported frequency bands
- 450 MHz to 3.8 GHz
Overview
The Anritsu ME7800L Simple Conformance Test System runs RF and protocol conformance tests on 3GPP-compliant LTE mobile terminals. It covers the basic LTE test items, including Cat-M1 and NB-IoT, and follows evolving 3GPP standards. RF/Performance/RRM tests and protocol tests can be added separately as needed. The system's built-in functions support work from network quality assurance through mobile terminal development.
Simple Equipment Configuration
The ME7800L focuses on the basic LTE test items, which keeps the amount of hardware required to a minimum. It is based on the ME7873LA and ME7834LA conformance test systems. A single Signalling Tester MD8430A acts as the base station simulator and runs both the RF/RRM and the protocol test software. Annual contract packages provide software updates for 3GPP standard changes as well as technical support.
Frequency Band Support
The system supports current and future 3GPP-defined frequency bands from 450 MHz to 3.8 GHz. This includes the GCF/PTCRB-certified bands used mainly in Europe and North America.
Certification and Reliability
The ME7800L received GCF/PTCRB approval as a new test platform in April 2017 and is registered as GCF Test Platform (TP) 160. Its calibration and correction functions are built in: basic correction at factory shipment, auto-calibration at start-up, and correction at each measurement. Because correction runs immediately before each measurement, temperature-related changes in the measurement system are removed, and customers do not need to calibrate the system every day.
Peripheral Control and Software
The DC power supply and constant temperature chamber needed for RF/RRM tests can be controlled by the system as standard; the customer supplies this equipment. Measurement results can be saved as HTML, XML or CSV, and the HTML reports link to the signalling log of each measurement. Protocol test logs can be analyzed with Protocol Analyzer 3. The system also outputs usage data by EUT, frequency band and measurement time.
Key Features
- Designed for organizations starting conformance testing
- All-in-one RF/RRM and protocol conformance testing with one Signalling Tester MD8430A
- Compliant with 3GPP standards and approved by GCF/PTCRB
- Registered as GCF Test Platform (TP) 160
- Supports LTE Cat-M1 and NB-IoT
- Supports spurious tests in the base model
- Basic correction at factory shipment, auto-calibration at start-up and correction at each measurement
- Built-in control of a DC power supply and a constant temperature chamber
- Sequence creation and editing from a task pane
- Histogram display of RRM measurement results
- Real-time SS log display during measurement
- Measurement results saved as HTML, XML or CSV
- Protocol log analysis with Protocol Analyzer 3
- Test case validation status from the GCF/PTCRB databases updated with one click
- Support packages with 3GPP software updates and technical support
Specifications
| Supported frequency bands |
450 MHz to 3.8 GHz
Current and future 3GPP-defined frequency bands
|
|---|
| TRx port | N-J, 50Ω, Maximum input +35 dBm |
|---|---|
| Rx port | N-J, 50Ω, Maximum input +30 dBm |
| Reference output | 10 MHz Buffered Output of MD8430A as standard |
|---|---|
| External oscillator signal input | Available (Frequency: 10 MHz, Connector: BNC) |
| Operating temperature | 15 °C to 35 °C |
|---|---|
| Storage temperature | 0 °C to 50 °C |
| Power voltage | 100 V (ac) to 120 V (ac)/200 V (ac) to 240 V (ac) |
|---|---|
| Frequency | 50 Hz/60 Hz |
| Power consumption | ≤ 2500 VA |
| EMC | 2014/30/EU, EN61326-1, EN61000-3-2 |
|---|---|
| LVD | 2014/35/EU, EN61010-1 |
| RoHS | 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018 |
| EMC | S.I. 2016 No.1091, EN 61326-1, EN61000-3-2 |
|---|---|
| LVD | S.I. 2016 No.1101, EN 61010-1 |
| RoHS | S.I. 2012 No.3032, EN IEC 63000:2018 |
| Supported releases |
Release 8, 9, 10 (only 2 Downlink Carrier Aggregation) and Release 13 (IoT only)
Applies to both RF/RRM and protocol testing
|
|---|---|
| RF/RRM testing | 3GPP TS 36.521-1 E-UTRA UE Conformance Specification Radio Transmission and Reception Part1: Conformance Testing |
| RF/RRM testing | 3GPP TS 36.521-3 E-UTRA UE Conformance Specification Radio Transmission and Reception Part3: RRM Conformance Testing |
| Protocol testing | 3GPP TS 36.523-1 Evolved Universal Terrestrial Radio Access (E-UTRA) and Evolved Packet Core (EPC); User Equipment (UE) conformance specification; Part 1: Protocol conformance specification |
| Protocol testing | 3GPP TS 34.229-1 Internet Protocol (IP) multimedia call control protocol based on Session Initiation Protocol (SIP) and Session Description Protocol (SDP); User Equipment (UE) conformance specification; Part 1: Protocol conformance specification |
| System | LTE/LTE-Advanced Cat-M/NB-IoT |
| Band 1 | UL 1920 to 1980, DL 2110 to 2170 |
|---|---|
| Band 2 | UL 1850 to 1910, DL 1930 to 1990 |
| Band 3 | UL 1710 to 1785, DL 1805 to 1880 |
| Band 4 | UL 1710 to 1755, DL 2110 to 2155 |
| Band 5 | UL 824 to 849, DL 869 to 894 |
| Band 7 | UL 2500 to 2570, DL 2620 to 2690 |
| Band 8 | UL 880 to 915, DL 925 to 960 |
| Band 9 | UL 1749.9 to 1784.9, DL 1844.9 to 1879.9 |
| Band 10 | UL 1710 to 1770, DL 2110 to 2170 |
| Band 11 | UL 1427.9 to 1447.9, DL 1475.9 to 1495.9 |
| Band 12 | UL 698 to 716, DL 728 to 746 |
| Band 13 | UL 777 to 787, DL 746 to 756 |
| Band 14 | UL 788 to 798, DL 758 to 768 |
| Band 17 | UL 704 to 716, DL 734 to 746 |
| Band 18 | UL 815 to 830, DL 860 to 875 |
| Band 19 | UL 830 to 845, DL 875 to 890 |
| Band 20 | UL 832 to 862, DL 791 to 821 |
| Band 21 | UL 1447.9 to 1462.9, DL 1495.9 to 1510.9 |
| Band 24 | UL 1626.5 to 1660.5, DL 1525 to 1559 |
| Band 25 | UL 1850 to 1915, DL 1930 to 1995 |
| Band 26 | UL 814 to 849, DL 859 to 894 |
| Band 27 | UL 807 to 824, DL 852 to 869 |
| Band 28 | UL 703 to 748, DL 758 to 803 |
| Band 29 | UL N/A, DL 717 to 728 |
| Band 30 | UL 2305 to 2315, DL 2350 to 2360 |
| Band 31 | UL 452.5 to 457.5, DL 462.4 to 467.5 |
| Band 32 | UL N/A, DL 1452 to 1496 |
| Band 33 | UL 1900 to 1920, DL 1900 to 1920 |
| Band 34 | UL 2010 to 2025, DL 2010 to 2025 |
| Band 35 | UL 1850 to 1910, DL 1850 to 1910 |
| Band 36 | UL 1930 to 1990, DL 1930 to 1990 |
| Band 37 | UL 1910 to 1930, DL 1910 to 1930 |
| Band 38 | UL 2570 to 2620, DL 2570 to 2620 |
| Band 39 | UL 1880 to 1920, DL 1880 to 1920 |
| Band 40 | UL 2300 to 2400, DL 2300 to 2400 |
| Band 41 | UL 2496 to 2690, DL 2496 to 2690 |
| Band 42 | UL 3400 to 3600, DL 3400 to 3600 |
| Band 48 | UL 3550 to 3700, DL 3550 to 3700 |
| Band 66 | UL 1710 to 1780, DL 2110 to 2200 |
| Band 71 | UL 663 to 698, DL 617 to 652 |
Applications
- LTE mobile terminal conformance testing
- Cat-M1 and NB-IoT device conformance testing
- Mobile terminal, module and chipset R&D
- Design verification
- Pre-certification testing
- Final-stage certification testing
- Network quality assurance
Included
- MN8160A Combiner Unit
- Z1938B Standard PC for SimpleCT (with monitor)
- ME7800L-AK000 Accessory Kit for ME7800L
- MD8430A Signalling Tester
- MS2692A Signal Analyzer
- MA24218A Microwave Universal USB Power Sensor (10 MHz-18 GHz)
- G0378B APSIN20 G-HC-AZ1 Signal Generator
- ME7800L Operation Manual (CD-ROM), 1 set
- Ethernet hub
- Cables
- Test SIM cards
Options & Accessories
| Option | Description |
|---|---|
| ME7800L-001 | LTE Protocol Test Package |
| ME7800L-011 | IoT Protocol Test Package |
| ME7800L-051 | LTE RF/RRM Test Package |
| ME7800L-061 | IoT RF/RRM Test Package |